Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance B 8A NEAR AGGARWAL SWEET CORNER BADARPUR EXTN NEW DELHI SOUTH DELHI DELHI 110044 | SOUTH EAST DELHI | DELHI | 110044 | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 4 | Not Admitted-Fee/PreQual/Technical SHOP NO 55 GROUND FLOOR ROHINI SECTOR 7 NAHARPUR FLOOR HARLAL MARKET NAHARPUR SECTOR 7 DELHI OPP GOYAL GARMENTS VILLAGE TOWN DELHI CITY DELHI | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 5 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
EMD Value
₹41,300
Closing Date
15 Mar 2022, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER (SDW)-II
S.T.P. OKHLA MATHURA ROAD NEW DELHI-110025
Renovation of Electrical feeding system with allied works in the office of EE (SDW) II Okhla.
2022_DJB_218576_11
NIT No-21 EE (SDW) II/ (21-22)
Open Tender
Electrical Works
Works
30 days
S.T.P. OKHLA MATHURA ROAD NEW DELHI-110025
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
A/c.50448339804
₹41,300
24 Mar 2022
9 Mar 2022
15 Mar 2022
9 Mar 2022
15 Mar 2022
9 Mar 2022
120 days
Renovation of electrical feeding system with allied works in the office of EE (SDW) II Okhla by carrying out following works including all the required works, materials, arrangements tools & tackles workmanship, safety arrangements & equipments as per NHRC guidelines etc. and as per site requirement, re-modelling all the damages up to standard if occurred any complete in all respect satisfactorily. The job is also including that job/item also which are necessary to make the equipments/site operational but not taken into the estimate. Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. ( DSR-2018) Make: Any DJB Approved make. Note-switch and modular plate as per approval by engineer-in-charge (1.10.0 & 1.10.3) Group C
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (DSR-2018) Make: Any DJB Approved make. Note-Make and model as per approval by engineer-in-charge (1.14 & 1.14.2) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 10 sq. mm + 1 X 6 sq. mm earth wire
S/F Two module Stepped type Electronic fan regulator on the existing modular plate switch box i/c connection but excluding modular plate etc as reqd. (DSR 2018) Make: Any DJB Approved make. Note-Make and model as per approval by engineer-in-charge
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. (DSR - 2018)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.(DSR-2018) Make: Any DJB Approved make. Note-Make and model as per approval by engineer-in-charge
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). Make: Any DJB Approved make. Note-Make and model as per approval by engineer-in-charge
S/F 3 pin 5 amps ceiling rose on existing switch box/wooden box i/c connection etc as reqd
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (as required) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc as reqd
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc as reqd. (1.5 & 1.50.1) up to 450mm sweep
Supply of 1200mm sweep super white ceiling fan (Copper winding) complete with capacitor, double ball bearing standard size of down rod,canopies, three nos. Blade made of aluminium alloy suitable for operation on single phase 230 Volt AC 50 HZ (Without regulator) Make: Any DJB Approved make. Note-Make and model as per approval by engineer-in-charge
Supply of 250/300 mm sweep, exhaust fan/ fresh air fan in plastic body with louvers, Robust motor for continuous running of fan, gravity shutter to prevent entry of foreign objects like dust, bird, pets etc. operation on 230V, 50 Hz AC single phase supply etc. as reqd. Make: Any DJB Approved make. Note-Make and model as per approval by engineer-in-charge
Individual Spot Light accent luminaire with extruded aluminium heat sink, Integral driver, 90° Angle adjustment. As per sample
Supplying and Fixing of Cabin / Wall fan of 400mm sweep on wall, making the hole on wall to fixing the fan, making good the damage, connection, testing and commissioning etc as reqd. Make: Any DJB Approved make. Note-Make and model as per approval by engineer-in-charge
Supplying, Installation, testing and commissioning of energy efficient surface/recess mounted type 32W to 38W full window glare free PMMA diffuser LED panel luminaries of size 2ft x 2 ft (nominal size) fabricated with MS powder coated white CRCA housing and connections with 3 x 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required The Total system Lumen of 34W to 38W LED should be minimum 3600 with minimum system efficacy of 100 lumen/watt colour temperature 5500K to 6500K, power factor>0.90, CRI (Ra)>75, THD <10%, with APFC driver having driver efficiency >85%, operating voltage 150-270 volts with minimum 2.5KV surge protection. . The LED chip should be of Cree, Bridge Lux, Nichia, Lumiled, Osram, Seoul. Make: Any DJB Approved make. Note-Make and model as per approval by engineer-in-charge
Supply of PVC insulated and PVC sheathed Aluminium Armoured Cable of size 2 core 10 sqmm tested on 1.1 kv, Make: Universal/Grandlay/ICC/Gloster/any DJB approved make. Note-Make and model as per approval by engineer-in-charge
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc as reqd
Supplying of 4 feet nominal size LED having extruded aluminium housing, colour temperature 6500K having wattage 18-24 Watt and Lumen output not less than 2000 Lumens directly on ceiling/wall i/c connection with 1.5 sqmm FRLS PVC insulated copper conductor , Single Core Cable and earthing etc as reqd. Make: Crompton/Havells/any DJB approved make. Note-Make and model as per approval by engineer-in-charge
Installation, testing and commissioning of pre-wired fluorescent fitting / compact fluorescent fitting of all types, fluorescent fitting / compact fluorescent fitting of all types,ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC etc as reqd.
S/I/T/C of Square surface mounted LED panel. PDC aluminum housing and high translucent frosted plastic diffuser makes it a robust Luminaire. Efficacy 100lm/w Make - Philips/Havells/Crompton/Any DJB approved make. Note-Make and model as per approval by engineer-in-charge
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade Upto 35 sq. mm (clamped with 1mm thick saddle)on wall surface as required.
Supplying and fixing of 32 mm dia X 2.00 meters long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV /HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required
S/I/T/C of LED streetlight 120 watt made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection. 10KV SPD included. Efficacy : 110LM/W Make - Philips/Havells/Crompton/ any DJB approved make. Note-Make and model as per approval by engineer-in-charge
Providing/ Fixing of junction/pole box suitable mounted on wall with clamp & suitable size nuts, bolts, hinged cover including 2no. Connector, connection with gland and termination and 1 no. SPMCB etc. as required. Make: Sintex/any DJB approved make.
S/I/T/C of Solar Inverter 7.5 KVA (BIS Certified) with complete wiring of inverter in each room as per direction of engineer-in-charge with following specifications. Rated AC power - 230V (Single Phase) Max Supported Panel Power - 6kW Input Voltage Range: Voc - 160V-240V (extracts upto 30% more power from Panels), Vmp - 120V-210V Charge Controller - MPPT Nominal Battery Bank Voltage - 96V (Supports 8 Batteries) Pure Sine Wave Output Solar Battery - LPTT12150H 150 Ah Rated Capacity @ C10, 12V Warranty - 72 Months Tubular plate Technology - Next generation tall tubular battery with better charge acceptance and longer backup No of Batteries in Combo - 8 Solar Panel - 445W/24V Capacity - 445W, 24V, Mono PERC half-cut Solar Panel Voltage: Voltage at Max Power (Vmax) - 39.40V, Open Circuit Voltage (Voc) - 47.28V Current: Current at Max Power (Imp) - 10.03A, Short Circuit Current (Isc) - 10.57A No of Panels in the Combo – 12 Make: luminous/Havells/ any DJB approved make and as per approval of engineer-in-charge
Dismantling old wiring, fan, tube fitting etc.
GOGIA BROTHERS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .