Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.7 LAccepted-AOC C O GENERAL DAIRY VILLAGE BARAGAON SRI GANGANAGAR 335 001 | GANGANAGAR | RAJASTHAN | 335001 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹31.6 L+₹1.9 L (6.34%)Rejected-Finance NEW ABADI KISHANPURA SURATGARH 335804 DISTT SRIGANGANGAR RAJ | GANGANAGAR | RAJASTHAN | 335804 | L2 | Rejected-Finance Rejected in AOC | |
| 3 | L3₹33.6 L+₹3.9 L (13.0%)Rejected-Finance | L3 | Rejected-Finance Rejected in AOC | |
| 4 | L4₹33.9 L+₹4.2 L (14.1%)Rejected-Finance | L4 | Rejected-Finance Rejected in AOC | |
| 5 | L5₹36.1 L+₹6.4 L (21.6%)Rejected-Finance | L5 | Rejected-Finance Rejected in AOC |
Tender Value
₹37.8 L
EMD Value
₹75,600
Closing Date
16 May 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE ARMY SURATGARH
GE ARMY SURATGARH
Provn of perimeter security wall of HS Pura Ascon Nodes under AGE BR II at Suratgarh Mil Stn
2022_MES_519927_1
GE (A) SOG - 05/22-23
Open Tender
Civil Works
Item Rate
270 days
SURATGARH
AS PER NIT
8 documents required · 8 mandatory
₹500
GE ARMY SURATGARH
₹75,600
Yes
9 Jun 2022
25 Apr 2022
18 May 2022
25 Apr 2022
16 May 2022
9 May 2022
60 days
Amount
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc, laid, bedded, jointed and pointed in any mortar complete all as specified and directed by Engineer-in-charge.
Dismantling cast iron work of any description complete all as specified and directed by Engineer-in-charge.
Excavation over areas not exc 1.5m deep and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth, or n exc 10 Sqm on plan and n exc 1.5 m in depth for foundations of poles, struts, stays etc. or laying underground cable and water supply / sewage pipe line etc. in soft / loose soil & getting out including taking out old brick or precast cable cover complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and directed by Engineer-in-charge.
Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and directed by Engineer-in-charge.
Surface excavation not exceeding 30 cm deep and averaging 15cm deep in soft/ loose soil and getting out complete all as specified and directed by Engineer-in-Charge.
M&L for hardcore of broken stone / boulders gauge not exc. 63mm, deposited, spread and leveled in layers not exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer-in-charge.
M&L for hard core of stone / boulders of gauge exceeding 63mm but n. exc 100mm, deposited, spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer-in-Charge.
M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation, filling & mass concrete complete all as specified and directed by Engineer-in-charge .
M&L for cement concrete 1:2:4, type B-1 (using 20mm graded stone aggregate) as in lintels upto 1.5 metre clear span, cills, steps, siesmic and other similar bands, plinth courses, string courses, lacing courses, coping, parapets and railing upto 60cm height, copings bed block,roof kerbs or mud stops, kerb stone, kneelers, apex stones, bed plates, surface channels and drains, benching, water troughs and the like including weathering, slightly rounded or chamfered angles and throatings etc.including necessary form work complete all as specified and directed by Engineer-in-Charge.
M&L for reinforced cement concrete M-25 design mix using 20 mm graded crushed stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc ; basement slabs, under- reamed piles and mass concrete complete all as specified and directed by Engineer-in -charge.
M&L for reinforced cement concrete M-25 design mix (using 20 mm graded crushed stone aggregate) as in beams , cantilever, bressummer, lintel over 1.5m span and similar work complete all as specified and directed by Engineer-in-Charge
M&L for providing reinforced cement concrete M-25 design mix, using 20mm graded stone aggregate as in column, pillars, piers, posts and sturts complete all as specified and directed by Engineer-in-Charge.
M&L for providing Reinforced cement concrete M-25 (design mix), using 20mm graded stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by Engineer-in-Charge.
M&L for Brick work with fly ash bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:4) complete all as specified and directed by Engineer-in-charge.
M&L for broken glass coping on top of wall built in cement mortar (1:3) complete all as specified & directed by Engineer-in-Charge.
M&L for use and waste of form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter for rough finished surfaces of concrete flat complete all as specified and directed.
M&L for use and waste of form work to soffits of suspended slab such as roof slab, floor slab, landing and similar work exceeding 200mm thick (horizontal or sloping), rough finished surface of concrete complete all as specified and directed by Engineer-in-Charge.
M&L for use and waste of form work to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finished flat surfaces of concrete complete all as specified and as directed by Engineer-in-charge.
M&L for Square, Circular rectangular on plan or polygonal use and waste of form work to sides pillars, posts, struts, pier, columns and stanchions for rough finished surfaces of concrete complete all as specified and directed.
S&F concertina coil fencing with required dia 610mm (having 15 Nos round per 6 metre length over 'Y' shaped security fencing with 9 horizontal RBT std tied with GI staples and GI clips to retain horizontal including necessary bolts or GI barbed wire tied to angle iron, with reinforced barbed tape (RBT) / spring core (2.5mm thick) wire of high tensile strength of wire of 165 Kg/sqmm with tape (0.52mm thick) and weight 43.478 gm/metre complete all as specified and directed by Engineer-in-charge.
M&L for cast iron work grade FG 150, machined, in pulleys and similar articles articles n exc 5 kg articles exc 5 kg each complete all as specified and directed by Engineer-in-Charge
S&F mild steel work as in hand made sliding bolts, hold fast, wind tie for roof covering including securing bolts necessary drilling bolts or reiveting conforrming to Fe-290 (Gde E-165) complete all as specified and directed by Engineer-in-Charge
S&F MS screw bolt 16 to 20mm dia, length of bolt exc 22.5cm and not exceeding 50cm long machine made with hexagonal or square head at one end and screwed the other or serewed both ends, each screwed end fitted with washer and one hexagonal or square nut complete all as specified and directed by Engineer-in-Charge.
S&F galvanized 2 strand, steel barbed wire 2.24mm dia, barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails, straining bolts, including securing or tying at crossing with and provision of galvanized mild steel wire, staples or steel pins etc complete all as specified and directed by Engineer-in-charge. Note :- Each line of horizontal / vertical / diagonal wire to be measured for the purpose of payment.
S&F mild steel TMT bars 6 to 8 mm dia cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed by Engineer-in-charge.
S&F mild steel TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed by Engineer-in-charge.
All as per serial item No 28 here-in-before but 5mm dia and over up to and including 10mm dia as in stirrups, spacers & binder etc.
S&F rolled sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails , fixed with angle cleats or other connecting plates, gusset plates, etc conforming to Fe-290 (Gde E- 165), complete all as specified & directed by Engineer-in-charge.
S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment etc conforming to Fe-290 (Gde E- 165, complete all as specified & directed by Engineer-in-charge.
S&F mild steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, cooler stand, framework of water tanks and similar works of quality Fe 290 (Gde E-165) etc complete all as specified and directed by Engineer-in-charge.
S&F mild steel framed work as in doors / gates / steel frames etc. of angle or other section with gusset plates, rails, braces, etc, complete, drilled for fixing of steel sheeting or other covering including necessary welding etc and fixing in position of quality Fe 290 (Gde E-165) complete all as specified and directed by Engineer-in-charge. Note : Cost of welding of butt hinges to the door frame deemed to included in quoted rate and butt hinges shall be measured & paid for “Supply only” separately under relevant item of this BOQ
M&L for 16 to 18mm thick Granite (of any type) slab of approved shade machine cut as on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of Granite tile including grinding & polishing (mirror polish i.e. full granite polish as per local trade practice) over and including 10mm thick rendering in cement & sand mortar (1:4) complete all as specified and directed by Engineer-in-charge.
M&L for 50 mm thick PCC (1:3:6) type C1 using 20 mm graded crushed stone aggregate as in plinth protection, finished fair and even complete all as specified and directed by Engineer-in-charge. Note :- Plinth protection shall be laid to slope (1 in 30) in bays not exceeding 3 metre in length and joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with sealing compound grade B. Cost of ceiling compund is included in the unit rate of this item
M&L for 75 mm thick PCC (1:4:8) type D-2 using 40 mm graded crushed stone aggregate as in sub base, finished fair and even complete all as specified and directed by Engineer-in-charge.
M&L for 100 mm thick PCC (1:4:8) type D-2 using 40 mm graded crushed stone aggregate as in sub base, finished fair and even complete all as specified and directed by Engineer-in-charge.
M&L for 40mm thick PCC (1:2:4) type B1 using 20mm graded crushed stone aggregate as in flooring finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-charge.
M&L for 25mm thick PCC (1:2:4) type B1 using 20mm graded stone aggregate as in flooring, finished even and smooth without using extra cement cement complete all as specified and as directed by Engineer-in-charge.
S&F factory casted 60mm thick machine pressed cement concrete interlocking paving blocks M-35 having compressive strength not less than 350 Kg / Sqcm using grey cement and no pigment and of shape hexagon/ triangular / zigzag / I-shaped / Three-X etc as directed conforming to IS 15658-2006, laid over & including 25mm thick sand cushion (local tibba sand), laid dry, joint filled with dry sand complete all as specified and directed by Engineer-in-Charge.
M&L for 15mm thick rendering in cement mortar (1:4) on fair faced or on other than fair face surface of brick masonary or concrete surface of walls, finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for 15mm thick rendering in cement mortar (1:6) on fair faced or on other than fair face surface of brick masonary or concrete surface of walls, finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for 10mm thick rendering in cement mortar (1:3) on brick or concrete surface of ceiling, finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for preparation of newly plastered surfaces of wall and applying three coats of white wash complete all as specified and directed by Engineer-in-charge.
M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed by Engineer-in-charge.
M&L for preparation of newly plastered surface of walls & applying two coats of cement base paint of approved shade/tint and filling cement based putty in cracks complete all as specified and directed by Engineer-in-charge.
M&L for preparation of new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge.
M&L for point wiring complete with 1.5 sqmm (nominal cross sectional area) FRLSH PVC insulated multistandard unsheathed copper conductor cable with colour coding drawn in and including new PVC rigid conduit medium grade 20mm dia and suitable fittings, fixed on surface of wall or concealed or above ceiling with accessories such as pipe hooks, elbows, junction box, terminated in existing sunken box and covered with new 3mm thick bakelite plastic laminated sheet top cover fixed flush with wall using brass screws & cup washers including cutting chases in wall for conduits and making good the disturbed surfaces of wall and including 1.5 sqmm PVC insulated unshethed multistandard copper conductor wire as earth continuity to common earth and connecting to earth dolly for one light point, fan point, bell point controlled by one switch complete all as specified and directed by Engineer-in- charge.
All as per serial item No. 48 here-in-before but for One 3 pin 5 Amp socket outlet on the same board with other switches.
All as per Srl item No. 48 above, but wiring with cable of cross sectional area 2.5 Sqmm (nominal area) multi-stranded copper conductor FRLSH, PVC unsheathed cable 1100 Volts shade for one switch socket combination 6 pin, 5/15 Amps on independent board including 2.5 Sqmm PVC insulated multistandard unsheathed copper conductor wire as earth continuity to common earth dolly.
S&F switch piano flush button 5 Amps single pole, one way complete all as specified and directed by Engineer-in-charge.
S&F switch socket combination 6 pin, 5/15 Amps, 230 volts, flush type complete all as specified and directed by Engineer-in-charge.
S&F socket outlet 3 pin, 5 Amps 240 volts, flush type complete all as specified and directed by Engineer-in-charge.
S&F ceiling rose surface bakelite 65mmx50mm with two or three terminal complete all as specified and directed by Engineer-in-charge.
S&F flush mounting factory made SPN DB 4 way, 240 Volt, Double door, IP-43 protection, IK-09 with metal door with 100 Amps copper bus bar, with neutral bar, earth bar and cables ties for cable management fully insulated bus bar complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 507610 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F MCB 6 to 32 Amps, Single Pole 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 408587 to 408595 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F isolator 40 Amps double pole suitable for 240 Volt AC supply complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 406501 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F Energy saving 9/10 watt environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head edge-lit LED luminaire comprising of high brightness LEDs, IP 65 protection fixed on wall complete all as specified and as directed by Engineer-in-charge. Make :- Havells Cat part No HEXAFT10WLED857 SSYMBOPC / Syska Cat part No SSK-BH-9W / Crompton cat part No LBHE-10-CDL or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F Energy efficient decorative ultra slim, prewired, lumiline 18 watt LED light fitting (Day cool light), batten type with drive & polycarbonate housing including tube rod and all accessories prewired fixed on wall / hanging complete all as specified and as directed by Engineer-in-charge. Make :- Havells Cat part No LUMILINEBS18WLED865 SPCWH / Syska Cat part No SSK-RA1801 Wipro cat part No LL20-221-XXX-65-NE / Philips cat part No 61009 BL CDL or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F wall mounted fan 400 mm sweep, 2100 RPM, single phase, 230 volts, 50 Hz with IP 55 protection and connecting up and including 3 core,1.5 sqmm PVC insulated if required & PVC sheathed copper conductor flexible cable drawn in flexible conduit fixed on wall complete all as specified & directed by Engr-in-charge. Make :- Havells Model No platina remote or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F LED flood light of 120 watt with high pressure die cast housing with lens with lument output 6000K complete (including LED, drive and internally prewired) with on board 5 KV surge protection with 10 KV external SPD. The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP 65 protection as per IS 10322-1982 (part-I) with latest amanedments and input voltage range 140-300V AC, frequency 50-60 Hz, P.F should be more than 0.9. The efficiency of LED luminaries system shall be more than 100 lumens per watt and FRLSH cable PVC insulated stranded copper conductor, 1100 volts grade, 2.5 sqmm x 3 core of ISI marked for light to ceiling rose complete including arrangement of mounting for street light as required at site complete all as specified and directed by Engineer-in-charge. Make :- Crompton / Havells / Philips / wipro or equivalent in makes mentioned in Appendix 'A' here-in-after.
M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to earth lead of GI wire 4 mm dia (8 SWG) by means of bolts, nuts and washers of the earth wire galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 15mm dia and water pipe 20mm dia GI light grade top of pipe with funnel & wiremesh, and bottom connected to earth plate by slit and two bolts/nuts/washers, PCC chamber in cement concrete (1:2:4) type B-1 and 40mm thick RCC cover, excavation & earth work complete all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 complete all as specified and directed by Engr-in-charge. Notes :- (i) GI wire upto DBs or upto earth test point is included in this item. (ii) Outer edge of earth pit chamber shall be 1.5 metre away from the outer edge of PCC chamber. (iii) Minimum weight of reinforcement for RCC cover shall be 1 KG.
Supplying, laying, jointing, commissioning and testing XLPE insulated screened PVC bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade of cross sectional area 16 sq mm 2 core confirming to IS-7098 (Part-I-1988) laid in trenches, along poles through pipes etc complete all as specified and directed by Engineer-in-charge. Notes :- (i) Excavation, earth work, sand cushioning, cable protection and GI pipe shall be measured & paid for separately under respective items of BOQ (ii) Road cutting / floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall deemed to be inclusive of the above provisions.
M&L for dry sand (Tibba sand) and punning for cushioning to underground cable complete all as specified and directed by Engineer-in-charge Note: - For payment purpose thickness after punning shall be measured.
M & L for brick protection with old size sub class 'B' bricks laid flat, length of bricks across the route of underground cable all as specified and directed by Engineer-in-Charge.
S&F Galvanized iron tubing, 40mm bore light grade, ISI marked, including all fittings and laid in trenches / under road / drains, fixed to poles / walls with required numbers of clamps made out of 25x3mm flat iron, bolts, nuts and washers for protection of LT electric cable complete all as specified and as directed by Engineer-in-charge. Notes :- (i) Excavation & earthwork shall be measured & paid for separately under respective items of BOQ (ii) Cost of flat iron clamp if required is included in the unit rate of this item. Nothing extra shall be paid on this account. -------------------------------------------------------------------------- Note :- A sum of Rs. 19423/- will be deducted on account of credit for dismantled/ demolished / taken down material. Please refer details on Srl Page No. 27 (Schedule of Credit) of Tender documents.
M/s JUGAL KISHORE MISHRA AND SONS
S.K BUILDERS AND ENGINEERS
AK CONSTRUCTION
BISHNOI BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .