Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.2 LAccepted-AOC BIDHAN PALLY OODLABARI P O MANABARI P S MALBAZAR DIST JALPAIGURI | JALPAIGURI | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹50.3 L+₹46,466.33 (0.93%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹50.5 L+₹69,990.33 (1.41%)Rejected-Finance SHATYAM APPARTMENT 35 BALAI DAS CHATTERJEE ROAD HAKIMPARA SILIGURI 1 | JALPAIGURI | WEST BENGAL | 734001 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹51.5 L+₹1.7 L (3.35%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹51.6 L+₹1.8 L (3.53%)Rejected-Finance 93 NAJRUL SARANI EAST VIVEKANANDA PALLY P O RABINDRA SARANI SILIGURI DIST DARJEELING PIN 734006 | SILIGURI | DARJEELING | WEST BENGAL | 734006 | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
11 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE SEVOKE ROAD
GE SEVOKE ROAD POST SALUGARA DIST JALPAIGURI
SPL REPAIR TO BLDG NO MA 100 AND MA 87 AND T 433 AND T 432 AND SP 06 AND PATHWAY AND PROVN OF CERTAIN REVENUE WORK AT BAGRAKOTE UNDER GE SEVOKE ROAD
2021_MES_488697_1
GE/SEV/52 OF 2021-22
Open Tender
Civil Works
Item Rate
180 days
GE SEVOKE ROAD
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE SEVOKE ROAD
₹90,000
Yes
8 Jan 2022
17 Nov 2021
13 Dec 2021
17 Nov 2021
11 Dec 2021
6 Dec 2021
18 Nov 2021 - 27 Nov 2021
60 days
Amount
Taking down chowkats with shutters (without taking off shutters from the frames) area not exceeding 1.50 Sqm each including guard bars complete all as specified
Taking down chowkats with shutters (without taking off shutters from the frames) area exceeding 1.50 Sqm but not exceeding 4.00 Sqm each complete all as specified
Dismantling of wrought iron or mild steel work of any description not other wise provided for complete all as specified and as directed.
Dismantling plain or corrugated steel sheeting any gauge or thickness as in roof covering complete all as specified and as directed.
Dismantling timber scantling 40 Sqcm and over in section in any position as in framed works complete all as specified and as directed.
Demolition of brick work or stone/boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc. but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified.
Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc 15 cm thickness (below or above GL) complete all as specified
Dismantling wall & ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified
Taking down cement plaster of any description including raking out joints, hacking for key, scrubbing down with water etc complete all as specified
M&L for preparation new wall surface and applying two coat of cement base paint over a coat of alkali resistant primer complete all as specified and directed.
M&L for Brick work with sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:4 complete all as specified and directed.
M&L for PCC 1:3:6 type C1 (using 20mm graded crushed stone aggregate) as in block for hold fast, filling in frames, copings or similar work and finished the surface with existing including form work. complete all as specified
S&F Mild steel bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required, hooks (stay), heavy, for large gates, hook and pintle hinges, large hasps and staples, chains, hand made sliding bolts, clamps, hold fasts, wall ties, hooks for hanging fans, plain angle cleats for securing purlines to steel trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165.
S&F pressed steel frames (Size-165X60mm) for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc complete all as specified .
S&F pressed steel frames (Size-105X60mm) for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc complete all as specified .
S&F factory made 2nd class hard wood rail and style 35mm thick plain framed, panelled shutter (two panel ) with lock rail and panel of 9mm B.W.P. commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and style as per IS:1003 (part I), kiln seasoned and chemically pressure treated complete all as specified.
S&F factory made 2nd class hardwood rail and style 35 mm thick Glazed and skeleton shutter open rebated and prepare to receive glass, gauge etc (without sash bars) edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing gauge etc size of members of shutters as specified in SSR part-I Section 8 and clause 8.24(a) complete all as specified
S&F mild steel tower bolts stove enamelled black with bright bolt 200 mm long complete all as specified and as directed.
S&F 300 mm long mild steel sliding door bolts plate type stove enamelled black with bright bolts not less than 12mm dia with and including a minimum of 6 bolts nuts, four on bolts plate & two on staple plate complete all as specified and as directed.
S&F mild steel pressed handle oval type stove enamelled black 150 mm long complete all as specified and as directed.
S&F 300mm Mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and as directed.
S&F Steel windows with side hung shutters including box type hinges with steel handle, and steel peg stay, including one coat of red oxide primer complete with glazing bars, dovetailed or welded complete all as specified and directed.
All as per item No 22 above , but without glazing bars complete all as specified..
S&F 3mm thick glass sheet ordinary quality & glazing with oil putty in square not exc 0.50 Sqm in each pane all as specified & directed.
S&F galvanized mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staple complete all as specified and as directed..
S&F mild steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 Gde-E-165 complete all as specified and directed.
S&F rolled mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment confirming to Fe 410 W Gde-E 250 Quality A complete all as specified and directed.
M&L rendering 15mm thick in CM 1: 6 on fair faces of brick/concrete surfaces finished even & smooth without using extra cement complete all as specified and as directed.
M&L for rendering 20mm thick on fair faces of brick work or concrete surfaces in CM 1:4 including mixing WPC as per manufacturers instruction, finished even and smooth without using extra cement. Note : WPC shall be measured seperately.
Supply only integral water proofing compound complete all as specified and as directed.
S&F rolled mild steel Roof trusses (framed), trussed, purlins, crane, gantries, rails and fastening and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc( Fe 410-W Gde-E-250) quality A Including preparation of surface and one shop coat of zinc chromate primer at contractors workshop before fabrication complete all as specified and directed by Engineer-in-Charge..
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering fixed with self drilling and self tapping screws, neoprene and limpet washers complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering fixed with self drilling and self tapping screws, neoprene and limpet washers complete all as specified and directed.
S&F mild steel screw bolt, 5 to 10mm dia machine made with hexagonal head at one end screwed the other or screwed both end, each screwed end to be fitted with washer and one hexagonal or square nut exceeding 05cm and not exceeding 10cm long complete all as specified.
S&F 605X605mm anodised aluminium snap grid frame work for false ceiling including 2.5mm dia mild steel wire galvanized class 3, @ 60cm centre to entre and fixed to steel or wooden member including 4mm thick Decorative non asbestos fibre cement boards fixed or laid/ inserted to aluminium frame work as in ceiling complete all as specified and directed. Note:- The size of aluminium main and croos tee shall be 40mm x25mm x2mm and size of angle shall be 25mm x 25mm x 2mm)
M&L for Preparing of new non AC board surfaces and applying three coats of white wash on ceiling complete all as specified.
Dismantling of floor hearth or wall tiling including cement mortar bedding (but not backing ) removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M&L for rendering in CM (1:4), 10mm thick on fair faces of brick work or concrete surfaces for fixing of wall tiles complete all as specified and as directed.
M&L for preparation old wall surface and applying a coat of white wash complete all as specified and directed.
M&L for glazed ceramic coloured tiles in vertical surface 450X350X7 mm thick set and jointed in neat cement slurry and pointed in coloured cement to match the surfaces complete all as specified and as directed.
M&L for non skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match the surfaces complete all as specified and as directed.
M&L for non skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18sqm but not exceeding 0.38 sqm, in Skirtings etc. set and jointed in neat cement slurry and pointed in coloured cement to match the surfaces complete all as specified and as directed.
M&L 75mm thick cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in plinth protection & paving finished even & smooth without using extra cement complete all as specified and as directed.
M&L for preparation of new untreated wood and wood base material of any description not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
M&L for preparation of new primed steel surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint complete all as specified and as directed.
M&L for preparing new steel and iron surfaces of any description n.exc 10 cm in width or girth and apply two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed.
M&L RCC 1:2:4 , type B1, 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span and lintel band, roof band and other similar items including form work all as specified.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire annealed, not less than 0.9mm dia or securing with clips complete all as specified.
All as per item No.48 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders all as directed.
S&F mild steel work (miscellaneous) as in wind ties for roof, flat iron fillets (for securing wire mesh etc) including drilling holes for securing bolts and fixed with bolts and nuts etc and similar work conforming to Fe-290.Gde-E-165, complete all as specified and as directed.
Complete removal of existing treatment on wall surfaces and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and as directed
M&L for preparation old treated plaster surfaces and applying one coats of distemper oil emulsion over a coat of chalk whiting on wall complete all as specified and as directed
M&L for preparation of new or untreated surfaces of walls and applying two coats of distemper oil emulsion over a coat of chalk whiting on wall complete all as specified and as directed
Taking down 15 mm bore GI pipe line including fittings and removal to store or cleaning for re-fixing complete all as specified and as directed.
Taking down 20 mm bore GI pipe line including fittings and removal to store or cleaning for re-fixing complete all as specified and as directed.
S&F 15 mm bore medium grade galvanized steel water tubing with all fittings and fixed to wall/ceiling or laid in floor complete all specified and directed.
S&F 20 mm bore medium grade galvanized steel water tubing with all fittings and fixed to wall/ceiling or laid in floor complete all specified and directed.
S&F in repair Bib taps, cast copper alloy fancy type with crutch or butterfly handle, screwed down, screwed for 15mm bore iron pipe or for brass ferrule complete all as specified and as directed.
Dismantling of 100 mm bore cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches complete all as specified and as directed
S&F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and as directed
S & F 110 mm bore PVC (SWR) bends of any radius complete all as specified & directed.
S & F 110 mm bore PVC (SWR) branch piece single (Single `T') equal or unequal with access door complete all as specified & directed.
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5m in depth for foundation, shafts, wells, cesspits, manholes, pier holes etc n.exc 10 sqm on plan and n exc 1.5 in depth and getting out in soft / loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
S&F in repair sinks without drain board, gloss finish, made of stainless steel 1 mm thick for kitchen with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe also including 40mm bore PVC waste pipe, overall size 495mm x 420mm, bowl size 410mm x 330mm x 160mm complete all as specified and directed.
M&L for RCC 1:2:4 type BI (using 20 mm graded crushed stone aggregate) as in slabs supported on walls, beams and coloumn in floors, roofs, landings, balconies, conopies, deck slabs and in shelves and the like complete all as specified and as directed.
Use and waste formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping for flat surface) complete all as specified and directed.
M&L 20mm thick granite slabs of any type (table rubbed and polished) on cooking platforms set and jointed in net cement slurry and pointing in white cement (1:4) using marble dust with admixture of pigment to match shade of granite including necessary moulding at edges laid over and including 20mm thick cement mortor screed bed in cement mortor (1:4) complete all as specified and directed.
M&L for brick work with fly ash bricks straight or curved on plan exc. 6mtr mean radius, built in cement mortar 1:6, complete all as specified and directed.
M&L for Brick work with fly ash bricks as in half brick thick wall built in CM (1:4), complete all as specified and directed.
S& F 2nd class hard wood (SAL) small fittings such as bracket of any type latch hinges blocked shapped door& window stopper and cleat including all necessary labour articles not exceeding 200 cu cm each complete all as specified.
S&F Steel ventilators with top hung shutter including hinges,steel peg stay, complete all as specified.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc complete all as specified.
M&L for brushing neat cement slurry with 3.0kg of cement per sq metre complete all as specified and directed
M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
M&L for preparation of new or untreated surfaces of walls and applying two coats of distemper oil emulsion over a coat of chalk whiting on walls complete all as specified and as directed
M&L for PCC 100mm thick cement concrete 1:4:8 type C-2 (using 40mm graded crushed stone aggregate) as in path/ hardstanding complete all as specified
M&L for screed bed or bedding layer of cement mortar 1:6, 20mm thick for laying floor finishes complete all as specified and as directed.
Dismantling posts or struts (wood, steel of R.C.C) any section embedded in concrete, including taking out embedded portion and making good disturbed ground complete all as specified and as directed.
Excavating in post holes (or similar holes) each n exc 0.50 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exc 25cm, watering and removing surplus soil to a distance not exc 50 m and making good surfaces in soft/loose soil complete all as specified and as directed.
M&L for cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundations, filling and mass concrete etc complete all as specified and as directed.
S&F 150 mm long floor door stoper of aluminium alloy body and tongue anodised with hard drawn steel spring fixed in floor complete all as specified and as directed.
Demolition of cement Concrete of any description and in any position not otherwise specifically provided for (Reinforced) complete all as specified and as directed.
M&L for non skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match the surfaces complete all as specified and as directed.
M&L for non skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11sqm but not exceeding 0.18 sqm, in Skirtings etc. set and jointed in neat cement slurry and pointed in coloured cement to match the surfaces complete all as specified and as directed.
Supply only 32 mm waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement & other end fixed complete all as specified and as directed.
S&F low density 32mm bore polythene waste pipe (LDPE) complete all as specified and as directed.
S & F 75 mm bore PVC (SWR) bends of any radius complete all as specified & directed.
S & F 75mm bore PVC (SWR) branch piece single (Single `T') equal or unequal with access door complete all as specified & directed.
S&F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and as directed
M&L for forming construction (Dummy) joints 65mm deepx10mm wide filled with sealing compound grade A complete all as specified and as directed.
M&L for Cutting chases in brick walls girth exc 10 cm but n.exc 20 cm , pinning in making good to facings where required and pointing in cement mortar 1:3 for concealed water tubing etc and making good complete all as specified.
M&L for cutting holes into or throgh brick walls built in cement mortar or cement lime mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required area not exc 150 sqcm including making good to complete all as specified.
Surface excavation n exc 30cm deep and averaging 15 cm deep and getting out in hard/dense soil complete all as specified and directed.
M&L 75mm thick PCC 1:4:8, type D2 (using 40mm graded crushed stone aggregated) as in sub base complete all as specified.
M&L PCC 1:2:4, type B0 (using 12.5mm graded crushed stone aggregate) as in copings, kerbs and the like incl weathering, slightly rounded or chamfered angles and throating, as directed incl necessary form work as reqd complete all as specified and as directed
M&L 60mm thick Machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size conforming to IS 15658- 2006 M-35 grade, laid as directed to any shape. Complete all as specified and as directed
M&L for Sand filling under floors or in foundations including watering and consolidation as in sand cushioning for interlocking paver blocks complete all as specified and directed.
M&L for broken stone or boulders as in Hardcore of gauge exc. 63 mm but n exc 100mm , deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified.
M&L for Continuous brick edging; with width equal to the depth of the brick, laid dry, on edge with fly ash modular bricks complete all as specified and as directed.
Excavation over areas not exceeding 1.5m deep and getting out in hard/dense soil complete all as specified and as directed
All as per item No 105 above but additional 1.5m deep or part there of in depth beyond the first 1.5m all as specified and directed by Engr-in- Charge.
M&L for Brick work with sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:4 complete all as specified and directed.
M&L for brick work with sub class 'B' bricks in one brick thick honey comb walling built in cm 1:4 complete all as specified and directed.
M&L for providing PCC 1:2:4, type B1 (using 20mm graded crushed stone aggregate) as in copings, complete all as specified and as directed
M&L for precast RCC 1:2:4, type B1 (using 20mm graded stone aggregate) as in cover slab set in CM 1:6 including necessary formwork complete all as specified and as directed
S&F mild steel TMT bars 8 mm dia, cut to length, bent to shape required, including cranking, bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed.
M&L rendering 15mm thick in CM 1: 4 on fair faces of brick/concrete surfaces finished even & smooth without using extra cement complete all as specified and as directed.
M&L for cement concrete 1:4:8 type D-2 Concrete bed to drain pipes including packing under and completely surrounding pipes with concrete after they are laid and tested; 110mm bore pipes complete all as specified and directed.
S & F 110 mm bore PVC (SWR) Vent cowl complete all as specified & directed
M&L for clean sawn and framed timber scantling second class hard wood (SAL) in scantlings in repairs to replace old and decayed timber (including piecing, scarfing etc of old and new timbers if required and removing defective portion to store complete all as specified and as directed.
M&L for preparing surfaces of wood and wood based materials new or old of any description and grith not otherwise described and treated with raw linseed oil complete all as specified and as directed.
Preparation of newly plastered surfaces and applying three coats of white wash on walls complete all as specified and as directed
Taking down carefully copper/Aluminum point wiring light fan, socket or power complete (fittings such as switches ceiling roses pendants, regulators, sockets, sketch light fittings, tube light fittings etc. to be measured separately if found serviceable) and removing unserviceable materials from site of work and segregating serviceable materials for safe custody and making good to disturbed surfaces of walls, floors, etc. including disconnecting of ceiling fan/exhaust fan complete all as directed
M&L for point wiring for light/fan/call bell etc. controlled by one switch with 1.50 Sqmm (nominal area) FRLS PVC insulated 1100 volts grade multi stranded copper conductor single core unsheathed cable drawn through and unsheathed single core solid copper conductor cable of size 1.50 Sqmm as earth continuity conductor connected to common earth dolly, including rigid PVC concealed conduit (Medium Grade) of suitable size, with all fittings and accessories including provision of mild steel terminal boxes of suitable size made with 1.2 mm thick mild steel sheet duly galvanised and suitable for fixing switches / sockets / regulators etc.and 3mm thick hylum sheet cover fixed in recess of wall with brass chromium plated screws and cup washer complete for one light / fan point controlled by one switch all as specified and directed.
All as per item No. 119 here-in-before but for 5/6 Amp socket point on independent board.
All as per item No. 119 here-in-before but for 5/6 Amp socket point on same board.
All as per item No.119 here-in-before but with 2.5 Sqmm cable for 15/16 Amp socket point on independent board and 2.5 sqmm solid copper cable for earth continuity conductor.
All as per item No.119 here-in-before but with 4.00 Sqmm cable for 15/16 Amp socket point on independent board and 4.00 sqmm solid copper cable for earth continuity conductor.
S&F Switch piano flush type, single pole, one way, 5/6Amp complete all as specified and as directed.
S&F Switch Socket combination, 2-in-1, 3 pin, 5/6 Amps flush type complete all as specified and as directed.
M & L for Socket outlet 3 Pin, 5 Amp flush type universal, 240 volts, complete as directed.
S&F Switch Socket combination, 5-in-1, 5/16 Amps flush type complete all as specified and as directed.
S&F Ceiling rose, surface bakelite, 3 terminals complete all as specified and as directed.
S&F electronic step regulator (speed regulation in 5 steps) suitable for ceiling fan 1200 / 1400 mm sweep 120 watt complete all as specified and as directed.
S&F LED tube light fittings 4 ft, 18w with aluminium batten heavy quality complete with side holders complete all as specified and directed.
S&F SPN MCB of capacity 32 Amps, 240 volts, C curve, 10 KA breaking capacity complete all as specified and as directed.
Supply and fixing 25 watt LED street light luminaires with highly efficient lighting in & including mounting bracket made out of GI pipe light grade 25mm bore not less than 01 mtr long duly fixed with wall with fixing arrangement such as clamps, nuts, bolts complete all as specified and directed by the Engr in charge.
S&F MCB, SP,240 volts, breaking capacity 10 KA C curve, rating 6 to 32 amps, complete all as specified and as directed.
Taking down old serviceable/unserviceable ceiling fan, connecting wire etc and keeping at site for reuse at site after carrying out repiar works to building/rewiring complete all as specified and directed by the Engr-in-charge
Supply and fixing energy efficient, 5 star rated ceiling fan 1200 mm sweep, with all acceesories and connecting up with the ceiling rose with new flexible wire of suitable size complete all as specified and as directed.
M&L for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of the earth plate not less than 1.5 m below ground level, connected to GI earth wire 4mm dia by means of bolts, nuts,check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of SSR Part-I, connected to earth test point all as specified or indicated including excavation and connected earth work in soft / loose soil, P.C.C 1:3:6 type C-1 as in pit, 20mm dia GI pipe light grade for watering pipe, 15mm bore GI light grade earth lead protection pipe, 50mm thick R.C.C. 1:2;4 type B-1 cover slab of earth pit reinforced with 8mm dia TMT bars @ 10cm C/C both ways and with handle made out of 10mm dia bars, funnel, strainer, including salt & charcoal and testing on completion including dismantling unserviceable earthing complete all as specified and as directed.
S&F Sheet Metal enclosure( IP-43) for SPN DBs,08Ways, double Door, suitable for mounting DP MCB as incomer & SP MCBs as outgoings, built- in bus bars complete suitable for 240 Volts, AC, 50 Hz supply, and fixed in recess in brick masonary wall all as specified and as directed
S&F ventilating fan plastic body 250mm sweep complete with louvers all as specified and as directed.
S&F decorative box type tube light fittings with LED light 20 watt 4 feet with aluminium extruded batten luminaire for 230 volt AC complete all as specified
S&F decortaive full glow squre PATTENS type recess mounted linear 40 watt panel LED fittings 2'x2' size with LED driver with high transmittenance luminaire for 230 volt AC complete all as directed by Engr-In-Charge
S&F new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium building security light with high power LED as light source lamp type 25 w with SPD , IP-66 protection with toughened glass including fixing pipe/saddle complete all as specified and as directed.
Supply and fixing DB with sheet metal enclouser 240 volts, 12 way with rated bus bar single pole & neutral double door for MCB, including cutting chases for DB of required size and making good disturbed surface area and putting blanking plate if required including taking down old unserviceable one complete all as specified and as directed. Make : Havells/Usha
S&F MCB, DP, 10 KA,415 V. "c" curve, 06-32 A , ISI marked complete all as specified and directed
Supply laying in trenches/wall LT UG XLPE insulated, armoured electric power cable (heavy duty) 1100 volt grade with stranded copper conductor of size 10 sqmm 2 core all as specified and directed.
Supply & laying in trenches clear sand for cushioning under cable 8 cm below and 15 cm above complete in level all as specified and directed by Engr-in-Charge. Note:- Punned thickness shall be measured.
Supply and laying burnt clay sub class B brick as cable protection all as specified and directed.
Supply and fix GI pipe 40mm bore medium grade for cable protection complete all as specified and as directed.
M/S JANARDAN SHARMA AND SONS
M/S SUBRATA JOARDAR
SRI SURAJIT SENGUPTA
PARTHA BISWAS AND CO
The Associated Construction And Co
SHRI JAYANTA GHOSH
M S ALOK SAHA
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .