Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹30.3 LAccepted-AOC | ₹30.3 L | 1 | Accepted-AOC ACCEPT |
| 2 | 2₹30.6 L+₹30,632.08 (1.01%)Rejected-Finance | ₹30.6 L+₹30,632.08 (1.01%) | 2 | Rejected-Finance reject |
| 3 | 3₹30.9 L+₹61,267.22 (2.02%)Rejected-Finance MU PO NANDLAPUR TA KARAD DIST SATARA | ₹30.9 L+₹61,267.22 (2.02%) | 3 | Rejected-Finance reject |
| 4 | 4₹31.1 L+₹76,584.79 (2.53%)Rejected-Finance | ₹31.1 L+₹76,584.79 (2.53%) | 4 | Rejected-Finance reject |
| 5 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹30.6 L
EMD Value
₹30,635
Closing Date
30 Apr 2026, 5:00 pmClosed
Additional Chief Executive Officer,Z.P.Satara
Additional Chief Executive Officer,Z.P.Satara
Construction of Remaining Work for Primary Health Sub Center Building AT Koregoan Tal- Karad Dist- Satara
2026_SATAR_1295302_2
A-2/E-Tendering/93/2026
Open Tender
Civil Works
Percentage
AT Koregoan Tal- Karad Dist- Satara
Registered qualified unemployed Engineers
9 documents required · 9 mandatory
₹1,180
₹30,635
16 Sept 2026
16 Apr 2026
4 May 2026
16 Apr 2026
30 Apr 2026
16 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Providing second class Burnt Brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 superstructure including striking joints, racking out joints, watering and scaffolding, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).
Item / Page No : 5 / 197
Specification No : Bd.G.5
Spec. Page No : 315
Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. | - | Cubic Metre | - | - |
| 1.02 | Providing second class Burnt Brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 superstructure including striking joints, racking out joints, watering and scaffolding, excetra complete. (For First Floor) (using ARTIFICIAL SAND).
Item / Page No : 5 / 197
Specification No : As per Item No 1a
Spec. Page No : ---
Additional Specifications : As per Item No 1a | - | Cubic Metre | - | - |
| 2.01 | Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks,laying/pumping, compaction and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND).
Item / Page No : 50 / 181
Specification No : Bd.F.6, B-7
Spec. Page No : 300-301, 38-40
Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. | - | Cubic Metre | - | - |
| 2.02 | Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks,laying/pumping, compaction and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For First Floor) (using ARTIFICIAL SAND).
Item / Page No : 50 / 181
Specification No : As per Item No 2a
Spec. Page No : ---
Additional Specifications : As per Item No 2a | - | Cubic Metre | - | - |
| 3.01 | Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap metal for reinforced cement concrete chajja as per detailed design and drawings including centering, formwork, cover blocks, compacting, finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate of natural sand/V.S.I. quality Artificial Sand (For Ground Floor) (using ARTIFICIAL SAND).
Item / Page No : 5 / 184
Specification No : BDF-9, B-7
Spec. Page No : 303-304, 38-40
Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. | - | Cubic Metre | - | - |
| 3.02 | Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap metal for reinforced cement concrete chajja as per detailed design and drawings including centering, formwork, cover blocks, compacting, finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate of natural sand/V.S.I. quality Artificial Sand (For First Floor) (using ARTIFICIAL SAND).
Item / Page No : 5 / 184
Specification No : As per Item No 3a
Spec. Page No : ---
Additional Specifications : As per Item No 3a | - | Cubic Metre | - | - |
| 4.01 | Providing and fixing in position thermo mechnically treated FE-500 steel bar reinforcement of various dias for reinforced cement concrete pile caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardis, copings, fins, arches, excetra as per detailed designs, drawings and schedules including cutting, bendding, hooking the bars, binding with wires or tack welding and supporting as requied complete. (For Ground Floor)
Item / Page No : 33 / 188
Specification No : Bd.F.17
Spec. Page No : 306 | - | Metric Ton | - | - |
| 4.02 | Providing and fixing in position thermo mechnically treated FE-500 steel bar reinforcement of various dias for reinforced cement concrete pile caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardis, copings, fins, arches, excetra as per detailed designs, drawings and schedules including cutting, bendding, hooking the bars, binding with wires or tack welding and supporting as requied complete. (For First Floor)
Item / Page No : 33 / 188
Specification No : As per Item No 4a
Spec. Page No : ---
Additional Specifications : As per Item No 4a | - | Metric Ton | - | - |
| 5.01 | Providing internal cement plaster 6 milimetre thick in a single coat in cement mortar 1:4 without neeru finish to concrete surface in all positions including scaffolding and curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).
Item / Page No : 1 / 209
Specification No : Bd.L.1
Spec. Page No : 367
Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. | - | Square Metre | - | - |
| 5.02 | Providing internal cement plaster 6 milimetre thick in a single coat in cement mortar 1:4 without neeru finish to concrete surface in all positions including scaffolding and curing, excetra complete. (For First Floor) (using ARTIFICIAL SAND).
Item / Page No : 1 / 209
Specification No : As per Item No 5a
Spec. Page No : ---
Additional Specifications : As per Item No 5a | - | Square Metre | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.84 MB
B193.pdf
Tender Documents • 0.88 MB
BOQ_2225561.xls
BOQ • 0.40 MB
CORREGENDUMCOMMONmerged.pdf
PDF • 4.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .