Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹23.2 LAccepted-AOC 14 SANSKAR TENAMENT 2 OPP VOLT AMP TRANSFORMERS MANEJA VADODARA 390013 | VADODARA | VADODARA | GUJARAT | 390013 | L-1 | Accepted-AOC STAND L-1 POSITION FOR SHEET-A,B,D AND E | |
| 2 | L-2₹26.3 L+₹9.3 L (17.6%)Accepted-AOC | L-2 | Accepted-AOC STAND L-1 POSITION FOR SHEET-C | |
| 3 | L-3₹62.4 L+₹9.6 L (18.1%)Rejected-Finance NO A47 AND A48 SIPCOT INDUSTRIAL GROWTH CENTRE ORAGADAM SRIPERUMBUDUR TALUK CHENNAI KANCHIPURAM TAMIL NADU 602105 | KANCHIPURAM | TAMIL NADU | 602105 | L-3 | Rejected-Finance STAND L-3 POSITION |
Tender Value
₹64.5 L
EMD Value
₹1.3 L
Closing Date
9 Sept 2020, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Chief Engineer,CSCTPP,Chhabra
Administrative Building ,CSCTPP, Chhabra
Supply of Rubber Expansion Joints for Pumps and PHEs installed at CSCTPP, Chhabra
2020_RRVUN_189423_1
TN-SC-46/2020-21
Open Tender
Mechanical Engineering Items
Item Wise
60 days
Plant Site, CSCTPP, Chhabra
As per QR
2 documents required · 2 mandatory
₹1,180
Yes
Accounts Officer,CSCTPP,Chhabra
₹1.3 L
Yes
25 Feb 2021
8 Jul 2020
10 Sept 2020
9 Jul 2020
9 Sept 2020
9 Jul 2020
180 days
SHEET-A ( Rubber Expansion Joints with Retainer Ring)
100 mm Drawing No. :- CSCTPP/REJ/4 Drawing Sr. No. :- 3 Design Pressure (Kg/cm²) :- 10 Hydro Test Pressure (Kg/cm²) at room temperature :- 15
500 mm Drawing No. :- CSCTPP/REJ/12 Drawing Sr. No. :- 1 Design Pressure (Kg/cm²) :- 5 Hydro Test Pressure (Kg/cm²) at room temperature :- 7.5
250 mm Drawing No. :- CSCTPP/REJ/9 Drawing Sr. No. :- 2 Design Pressure (Kg/cm²) :- 16 Hydro Test Pressure (Kg/cm²) at room temperature :- 24
250 mm Drawing No. :- CSCTPP/REJ/9 Drawing Sr. No. :- 3 Design Pressure (Kg/cm²) :- 16 Hydro Test Pressure (Kg/cm²) at room temperature :- 24
350 mm Drawing No. :- CSCTPP/REJ/10 Drawing Sr. No. :- 1 Design Pressure (Kg/cm²) :- 5 Hydro Test Pressure (Kg/cm²) at room temperature :- 7.5
450 mm Drawing No. :- CSCTPP/REJ/11 Drawing Sr. No. :- 1 Design Pressure (Kg/cm²) :- 3.5 Hydro Test Pressure (Kg/cm²) at room temperature :- 5.25
300 mm Drawing No. :- CSCTPP/REJ/9 Drawing Sr. No. :- 1 Design Pressure (Kg/cm²) :- 6.5 Hydro Test Pressure (Kg/cm²) at room temperature :- 9.75
200 mm Drawing No. :- CSCTPP/REJ/7 Drawing Sr. No. :- 5 Design Pressure (Kg/cm²) :- 10 Hydro Test Pressure (Kg/cm²) at room temperature :- 15
125 mm Drawing No. :- CSCTPP/REJ/5 Drawing Sr. No. :- 1 Design Pressure (Kg/cm²) :- 10 Hydro Test Pressure (Kg/cm²) at room temperature :- 15
100 mm Drawing No. :- CSCTPP/REJ/4 Drawing Sr. No. :- 4 Design Pressure (Kg/cm²) :- 15 Hydro Test Pressure (Kg/cm²) at room temperature :- 22.5
100 mm Drawing No. :- CSCTPP/REJ/4 Drawing Sr. No. :- 2 Design Pressure (Kg/cm²) :- 5 Hydro Test Pressure (Kg/cm²) at room temperature :- 7.5
150 mm Drawing No. :- CSCTPP/REJ/6 Drawing Sr. No. :- 1 Design Pressure (Kg/cm²) :- 3 Hydro Test Pressure (Kg/cm²) at room temperature :- 4.5
150 mm Drawing No. :- CSCTPP/REJ/6 Drawing Sr. No. :- 2 Design Pressure (Kg/cm²) :- 5 Hydro Test Pressure (Kg/cm²) at room temperature :- 7.5
150 mm Drawing No. :- CSCTPP/REJ/6 Drawing Sr. No. :- 3 Design Pressure (Kg/cm²) :- 10 Hydro Test Pressure (Kg/cm²) at room temperature :- 15
200 mm Drawing No. :- CSCTPP/REJ/7 Drawing Sr. No. :- 1 Design Pressure (Kg/cm²) :- 3.5 Hydro Test Pressure (Kg/cm²) at room temperature :- 5.25
450 mm Drawing No. :- CSCTPP/REJ/11 Drawing Sr. No. :- 2 Design Pressure (Kg/cm²) :- 3.5 Hydro Test Pressure (Kg/cm²) at room temperature :- 5.25
600 mm Drawing No. :- CSCTPP/REJ/13 Drawing Sr. No. :- 1 Design Pressure (Kg/cm²) :- 6.5 Hydro Test Pressure (Kg/cm²) at room temperature :- 9.75
1850 mm Drawing No. :- CSCTPP/REJ/4 Drawing Sr. No. :- 1 Design Pressure (Kg/cm²) :- 5.6 Hydro Test Pressure (Kg/cm²) at room temperature :- 8.4
2600 mm Drawing No. :- CSCTPP/REJ/16 Drawing Sr. No. :- 1 Design Pressure (Kg/cm²) :- 5.6 Hydro Test Pressure (Kg/cm²) at room temperature :- 8.4
250 mm Drawing No. :- CSCTPP/REJ/8 Drawing Sr. No. :- 1 Design Pressure (Kg/cm²) :- 3 Hydro Test Pressure (Kg/cm²) at room temperature :- 4.5
250 mm Drawing No. :- CSCTPP/REJ/8 Drawing Sr. No. :- 2 Design Pressure (Kg/cm²) :- 7 Hydro Test Pressure (Kg/cm²) at room temperature :- 10.5
250 mm Drawing No. :- CSCTPP/REJ/8 Drawing Sr. No. :- 3 Design Pressure (Kg/cm²) :- 10 Hydro Test Pressure (Kg/cm²) at room temperature :- 15
200 mm Drawing No. :- CSCTPP/REJ/8 Drawing Sr. No. :- 4 Design Pressure (Kg/cm²) :- 13.25 Hydro Test Pressure (Kg/cm²) at room temperature :- 19.87
SHEET-B ( Rubber Expansion Joints with Retainer Ring)
ESP 80 Drawing No. :- CSCTPP/REJ/3 Drawing Sr. No. :- 1 Design Pressure (Kg/cm²) :- 5 Hydro Test Pressure (Kg/cm²) :- 7.5
ESP 100 Drawing No. :- CSCTPP/REJ/4 Drawing Sr. No. :- 1 Design Pressure (Kg/cm²) :- 3 Hydro Test Pressure (Kg/cm²) :- 4.5
ADMIN 200 Drawing No. :- CSCTPP/REJ/7 Drawing Sr. No. :- 3 Design Pressure (Kg/cm²) :- 6 Hydro Test Pressure (Kg/cm²) :- 9
AC PLANT 200 Drawing No. :- CSCTPP/REJ/7 Drawing Sr. No. :- 4 Design Pressure (Kg/cm²) :- 7 Hydro Test Pressure (Kg/cm²) :- 10.5
SHEET-C ( Rubber Expansion Joints with Retainer Ring)
350 mm Drawing No. :- CSCTPP/REJ/10 Drawing Sr. No. :- 2 Design Pressure (Kg/cm²) :- 10 Hydro Test Pressure (Kg/cm²) :- 15
450 mm Drawing No. :- CSCTPP/REJ/11 Drawing Sr. No. :- 3 Design Pressure (Kg/cm²) :- 6.5 Hydro Test Pressure (Kg/cm²) :- 9.75
450 mm Drawing No. :- CSCTPP/REJ/11 Drawing Sr. No. :- 4 Design Pressure (Kg/cm²) :- 10 Hydro Test Pressure (Kg/cm²) :- 15
2400 mm Drawing No. :- CSCTPP/REJ/15 Drawing Sr. No. :- 1 Design Pressure (Kg/cm²) :- 5.6 Hydro Test Pressure (Kg/cm²) :- 8.4
SHEET-D ( Rubber Expansion Joints with Retainer Ring)
Elect.Jockey Pump Discharge Design Pressure (Kg/cm²) :- 13.25 Hydro Test Pressure (Kg/cm²) at room temperature :- 19.88 Pipe Size & Length (mm) :- 40 x 150
Elect.Jockey Pump Discharge Design Pressure (Kg/cm²) :- 3.57 Hydro Test Pressure (Kg/cm²) at room temperature :- 5.35 Pipe Size & Length (mm) :- 60 x 150
Diesel HYD.FP Suction , Elec.Hyd.FP Suction, Diesel Spray FP Suction , Elec.Spray FP Suction Design Pressure (Kg/cm²) :- 3.57 Hydro Test Pressure (Kg/cm²) at room temperature :- 5.35 Pipe Size & Length (mm) :- 200 x 150
Diesel Hyd FP Booster Discharge , Elec Hyd FP Booster Pump Discharge Design Pressure (Kg/cm²) :- 18.35 Hydro Test Pressure (Kg/cm²) at room temperature :- 27.5 Pipe Size & Length (mm) :- 200 x 150
Diesel Hyd FP Booster Suction , Elec.Hyd FP Booster Suction Design Pressure (Kg/cm²) :- 13.25 Hydro Test Pressure (Kg/cm²) at room temperature :- 19.87 Pipe Size & Length (mm) :- 250 x 200
SHEET-E ( Non -Mettalic Flexible Connection for Mill Seal Air Fan)
Non-Metallic Flexible Connection ( Inlet Non-Metallic Flexible Connection(Mill Seal Air Fan) & G.A. Drg. No. 45500-1002)
Non-Metallic Flexible Connection ( Outlet Non-Metallic Flexible Connection(Mill Seal Air Fan) & G.A. Drg. No. 45500-1003)
Yati International Incorporation
MB METALLIC BELLOWS PVT LTD
stage.html
html • 0.05 MB
technical_335262.pdf
PDF • 0.10 MB
techsummary_335262.pdf
PDF • 0.07 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_335262.pdf
PDF • 0.15 MB
COMPLETEPOTNSC46.pdf
PDF • 5.34 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .