Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.2 LAccepted-AOC B 101 SURAJ TOWER MIRA BHAYANDER ROAD OPP SAI PETROL PUMP MIRA ROAD EAST THANE 401107 | MIRA ROAD EAST | THANE | MAHARASHTRA | 401107 | L1 | Accepted-AOC L1 | |
| 2 | L2₹31.1 L+₹13,100 (0.42%)Rejected-Finance | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹33.4 L+₹2.5 L (8.02%)Rejected-Finance 1 2 GR FLOOR VITHALKUNJ NO 3 V P ROAD ANDHERI WEST MUMBAI 400 058 | MUMBAI SUBURBAN | MAHARASHTRA | 400058 | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹34.2 L+₹3.3 L (10.5%)Rejected-Finance 1101 A WING SACHDEV COMPLEX JANGAL MANGAL RAOD BHANDUP W MUMBAI 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹35.2 L+₹4.2 L (13.7%)Rejected-Finance | L5 | Rejected-Finance Being other than lowest |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
9 Mar 2023, 6:00 pmClosed
CWE (NW) MUMBAI
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
REPAIR MAINTENANCE OF FIRE FIGHTING SYSTEM AND ASSOCIATED WORKS AT NOFRA AREA BUILDINGS UNDER GE (NW) NAVY NAGAR COLABA MUMBAI
2023_MES_579915_1
8134/CWE (NW) Mumbai/E8
Open Tender
Civil Works
Item Rate
180 days
GE (NW) NAVY NAGAR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE (NW) NAVY NAGAR
₹1 L
Yes
1 May 2023
9 Feb 2023
11 Mar 2023
9 Feb 2023
9 Mar 2023
23 Feb 2023
9 Feb 2023 - 22 Feb 2023
Amount
Schedule 'A' Part- I Repair/Routine maintenance including carrying out daily check of fire alarm/fire fighting system complete with electronic control panel consisting of 16 zones in 02 (Two) Buildings Meena, Swati (G+13 floors) ie 13 storeys including appointment of a skilled personnel to attend the fire alarm system faults, testing, checking and replacement of unserviceable components other than mentioned in schedule “A” Part-II The fire alarm system consisting the following complete all as specified and directed by Engineer-in-Charge.:- (a) Indicator (b) Electronic hooter (c) Manual call point (d) Smoke detector (e) Heat detector (f) Electronic fire control panel (g) Main/Zone cards (h) Battery of Fire panel DC supply (J) All wiring and cable connections
Ditto all as above item No 1.00 but 17 zones in 4 (Four) Buildings Kanya, Chitra, Anuradha & Alaknanda (G+14 floors) ie 15 storeys and 01 (One) Buildings Archana( G+15 floors) complete all as specified and directed by Engineer-in-Charge..
Ditto All as above item No 1.00 but 15 zones in 04 (Four) Buildings Bharani, Saravana, Vidya & Vijaya (G+12 floors) ie 13 storeys complete all as specified and directed by Engineer-in-Charge.
Ditto All as above item No 1.00 but 12 zones in 04 (Four) Buildings Revati, Rohini, Karthikeya & Gemini (G+9 floors) ie 10 storeys complete all as specified and directed by Engineer-in-Charge.
Repair/Routine maintenance including carrying out daily check of fire fighting system 09 zone complete 04 (Four) Buildings WNC Mess main bldg, Annex bldg, Hemadri and transist bldg (G+07 floors) ie 08 storeys 04 (Four) Buildings Narmada, Tapti, Kaveri, Hoogly and Vishkarma bldg (G+06 floors) ie 07 storeys including attending system faults, testing, checking including replacement of unserviceable components other than mentioned in schedule “A” Part-II complete all as specified and directed by Engineer-in-Charge.
Schedule 'A' Part- II Supply and replacement, installation, testing & commissioning of Micro processor based 2 wire fault tolerant loop, required loop networkable type 2 Loop (each loop accessing maximum 99 detectors and 99 modules upto 200 detctor and modules) fire alarm/detection control panel complying with BS EN 54. The panel should indicate location of all fire/fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON /OFFrespective control module whenever any alarm is triggered. The panel shall have rectifier, Loop cards, 80 character L C D unit to indicate Fire/Fault Signal with address and analogue output, external/inbuilt printer to log all fire or fault events complete in all respects. The Panel shall support 24 zones Addressable complete all as specified and directed by Engineer-in-Charge.
Note: In case of emergency, specifications shall conform to BS5839 Standards and Duly Approved by EN54/LPCB/VDS/UL/BSA complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing in repair detectors Complying with and type certified to EN - 45 Addressable type multisensor detector with heat and smoke combination detector Photoelectric/optical with base with self intelligence as per IS 11360 complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing in repair Maintenance free battery duly charged 12 V 7.2 AH complete all as specified and directed by Engineer-in-Charge.
Material and Labour factory fabricated hose box made of 18 gauge MS sheet 800mm X 600mm X 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard fixed on wall with necessary nut/bolts or welding to existing MS pipe by supporting angle complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing in repair rubber hose pipe 30 mtr,20mm dia plain 2 ply rayon braided high pressure complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing in repair canvas fire hose 63mm bore 15 m long confirming to IS Having male/female brass coupling both end complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing in repair Stainless steel Nozzle 25 mm bore suitable for 63mm dia canvas pipe complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing in repair hose Reel drum suitable for 30 mtrs X 20 mm dia rubber hose pipe complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing in repair 100 mm dia ERW MS pipe heavy grade with all fittings and applying two coats of synthetic enamel paint over a coat of red oxide primer to pipe including supporting brackets complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing in repair 150 mm dia ERW MS pipe heavy grade with all fittings and applying two coats of synthetic enamel paint over a coat of red oxide primer to pipe including supporting brackets complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing in repair gun metal Two way fire brigade inlet conection with adaptor of size 80 mm dia X 63 mm dia complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing in repairs Branch pipe gun metal 63mm instantaneous inlet, made threaded outlet, 15mm bore nozzle short complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing in repair twin outlet hydrant valve 100mm having 65mm outlet with lock pin wheel complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in repair single outlet hydrant valve 100mm having 65mm outlet with lock pin wheel complete all as specified and directed by Engineer-in-charge
Supply and Fixing in repair sluice valve 150mm size both ends flayed with high tensile stainless steel spindle, I body as per IS-14826, ISI Marked,class PN-1.6 including all joints with rubber or fibre board, nuts, bolts, washers etc complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing in repair Sluice Valve 100mm size both ends flayed with high tensile brass spindle, body including all joints with rubber or fibre board, nuts, bolts, washers etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair Foot valve ball type10/15Kg/sqcm (MODEL B-5) of (ISI marked) in position at location including Material and Labour for making flanged joints and making good to existing PCC surface of following sizes complete all as specified and directed by Engineer-in-Charge. :-
100 mm dia
150 mm dia
Disconnecting LT cables of various sizes from electric motor of 15 HP/11 KW capacities and decoupling from the pumping sets. Removing and taking down carefully and transporting to authorised workshop for rewinding. Strip opening and dismantling complete rotor and stator assembly. Cutting and taking out old burnt copper winding from the stator assembly and cleaning the slots of stator with carbon tetra chloride solution. Material and labour for rewinding, complete stator assembly with and including super enamelled copper winding, wire of suitable gauge matching with existing. Applying minimum two coats of insulation varnish and keeping the stator assembly in heating chamber to improve for insulation value. Assembling the motor, transporting to site of work, coupled with the pumping set, alignments properly, connecting the LT cables and commissioning complete all as specified and directed by Engineer-in-Charge.
Disconnecting LT cables of various sizes from electric motor of 55KW/75HP capacities and decoupling from the pumping sets. Removing and taking down carefully and transporting to authorised workshop for rewinding. Strip opening and dismantling complete rotor and stator assembly. Cutting and taking out old burnt copper winding from the stator assembly and cleaning the slots of stator with carbon tetra chloride solution. Material and labour for rewinding, complete stator assembly with and including super enamelled copper winding, wire of suitable gauge matching with existing. Applying minimum two coats of insulation varnish and keeping the stator assembly in heating chamber to improve for insulation value. Assembling the motor, transporting to site of work, coupled with the pumping set, alignments properly, connecting the LT cables and commissioning complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing in repair DE bearing including necessary greasing reassembling the motor connecting, testing and commissioning complete for Motor capacity 75 HP bearing No 1314 complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing in repair DE bearing including necessary greasing reassembling the motor connecting, testing and commissioning complete for Motor capacity 15 HP bearing No 6213/C4 complete all as specified and directed by Engineer-in-Charge.
Supply, laying, jointing and testing in replacement of PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, conforming to IS 694 6 Core 0.5 sqr mm including making necessary connection, with busbar/MCCB/DB's & testing complete all as specified and directed by Engineer-in-Charge.
Supply, replacement, Installation,Testing & Commissioning of Addressable Type Manual Call Point with Mounting Base as required conforming (UL's Latest Edition Approved and NFPA compliant / VDS or LPCB tested and EN54 compliant) complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement, Installation,Testing & Commissioning of Addressable electronic sounder cum strobe complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair Star Delta starter suitable for 15 HP/11 KW pump set current relay range 9-13Amp ,3 phase 430 V ,50Hz complete all as specified and directed by Engineer-in-Charge.
Disconnecting horizontal split casing pump of any make/model, dismantling and taking out pump shaft assembly complete for replacement of pump gasket and brass bush including greasing the pumpset connecting to coupling testing & commissioning and providing MS guard for following sizes / capacities of pump complete all as specified and directed by Engineer-in-Charge.:-
Pump coupled with Motor capacity 75 HP
Pump coupled with capacity 15 HP
Supply, laying, jointing and testing in replacement of PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, conforming to IS 694 4 Core 1.5 sq mm including making necessary connection, with busbar/MCCB/DB's & testing complete all as specified and directed by Engineer-in-Charge.
Supply, laying, jointing and testing in replacement of PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, conforming to IS 694 2 Core 1.5 sq mm including making necessary connection, with busbar/MCCB/DB's & testing complete all as specified and directed by Engineer-in-Charge.
Material and Labour for DI specials conforming to IS - 9523, spigot /socket or flanged fitting I.e. bend, tee, collar, flanged/ socket /spigot, Tappers and tails pieces etc suitable for 100/150/200/250/300 mm bore pipes (joints and joining material shall be measured and paid seperately) complete all as specified and directed by Engineer-in-Charge.
Supply and laying in replacement of spigot and socket Ductile iron water tubing having cement mortar lining on inner surface and one coat of bituminous paint over exposed surface ISI marked, IS No. 8329:2000, including rubber joint of suitable size, class K-9 laid on wall/roof/floor/trenches with proper alingnment as per site requirement and to carryout testing against leakage before filling the trenches etc complete all as specified and directed by Engineer-in-Charge.
150mm bore
100mm bore
Excavation in trenches not exceeding 1.5 mtr wide not exceeding 1.5 mtr in depth and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cms in any type of soil complete all as specified and directed by Engineer-in-Charge.
Note : For item No 36 and 37 above rate deemed to be included for earth work and form work required as per site requirement complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15 cm thickness (below or above ground level) and removing the debris out side MoD land complete all as specified and directed by Engineer-in-Charge.
Material and Labour cement concrete 1:2:4, type B-2 (using 40 mm graded stone aggregate) as in foundation and mass filling for support of CI pipes,finishing even and fair without using extra cement complete all as specified and directed by Engineer-in-Charge.
Removing excavated material exc 250 M but n.exc 500 M and depositing where directed complete all as specified and directed by Engineer-in-Charge.
Hardik Engineers
Darpan Construction
sapana enterprises
Shetty Construction Co
Shree Ayyappa Engineering
GANGAJAL
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .