REPAIR/ MAINT OF DG SETS, VOLTAGE STABILIZER, CRANES, SERVICES OF INCINERATORS, WASHING MACHINES, AIR COMPRESSOR, LIGHTNING ARRESTERS, EARTHING IN ELETRICAL INSTALLATION AND ALLIED ITEMS AT ACC AND S UNDER GE(N) AHILYANAGAR
2026_MES_771673_1
8226/E8
Open Tender
Electrical and Maintenance Works
335 days
Garrison Engineer (North) Ahilyanagar
As per NIT
8 documents required · 8 mandatory
₹500
Garrison Engineer (North) Ahilyanagar
₹90,000
Yes
12 Jun 2026
12 Jun 2026
6 Jul 2026
12 Jun 2026
3 Jul 2026
26 Jun 2026
(ii) 160 KVA/200 KVA
(iii) 100 KVA/110/ KVA/125 KVA
(iv) 62.5 KVA/ 63 KVA
(vi) 25 KVA/ 20 KVA
(vii) 18.75 KVA/ 15 KVA
(viii) 7.5 KVA/10 KVA
(viii) 200 KVA
Taking down defective self-starter 12/24 Volt of D. G. set of capacity 100 KVA to 320 KVA D. G set installed at various installations & servicing / overhauling including replacing worn out part like solenoid, bearing, carbon brush, rewinding the starter motor winding etc. & refitting the same after repair for smooth functioning in all respect.
.-ditto- all as per Ser item No 02 above but 15 KVA to 63 KVA
M&L for cleaning the fuel tank both internally & Externally by removing all the dust / sediments etc. in cluding writing of tank capacity, Date of cleaning for followings capacity of DG Sets :-
(ii) 160 KVA/200 KVA
(iii) 100 KVA/110 KVA/125 KVA
(iv) 62.5 KVA/ 63 KVA
(vi) 25 KVA/ 20 KVA
(vii) 18.75 KVA/ 15 KVA
(viii) 7.5 KVA/10 KVA
Supply and fix in replacement of Diesel fiiter with 'O' Ring suitable for following capacity of D. G. sets as per sample :-
(ii) 160 KVA/ 200 KVA
(iii) 100 KVA/ 110 KVA/ 125 KVA (Total 10 Nos)
(iv) 62.5 KVA/ 63 KVA
(vi) 25 KVA/ 20 KVA
(vii) 18.75 KVA/ 15 KVA
(viii) 7.5 KVA/10 KVA
Supply and fix in replacement of Air fitter element suitable for following capacity of D. G. sets as per sample :-
(ii) 160 KVA/200 KVA
(iii) 100 KVA/110 KVA/125 KVA (Total 11 Nos)
(iv) 62.5 KVA/ 63 KVA
(vi) 25 KVA/ 20 KVA
(vii) 18.75 KVA/ 15 KVA
(viii) 7.5 KVA/10 KVA
Supply and fix in replacement of oil fitter element with 'O' Ring suitable following capacity of D. G. sets as per sample :-
(ii) 160 KVA/200 KVA
(iii) 100 KVA/110 KVA/125 KVA (Total 10 Nos)
(iv) 62.5 KVA/ 63 KVA
(vi) 25 KVA/ 20 KVA
(vii) 18.75 KVA/ 15 KVA
(viii) 7.5 KVA/10 KVA
Supply & fix in repair replacement of set of belts suitable for following capacity of D. G. sets as per existing at site :- Note : Each set included dynamo belt, Fan belt and water pump belt.
(ii) 160 KVA/200 KVA
(iii) 100 KVA/110 KVA/125 KVA (Total 10 Nos)
(iv) 62.5 KVA/ 63 KVA
(vi) 25 KVA/ 20 KVA
(vii) 18.75 KVA/ 15 KVA
(viii) 7.5 KVA/10KVA
M & L for replacement of set of Rubber Hose for water & Air circuit complete suitable for D. G. sets of following Capacities:-
(ii) 160 KVA/200 KVA
(iii) 100 KVA/110 KVA/125 KVA (Total 10 Nos)
(iv) 62.5 KVA/ 63 KVA
(vi) 25 KVA/ 20 KVA
(vii) 18.75 KVA/ 15 KVA
(viii) 7.5 KVA/10 KVA
Scrapping / cleaing the existing paint completely and painting with two coats of anti corrosion synthetic enamal paint with spray painting colour as to be followed). D. G. set (Internal & External), fuel tank etc. :-Note : Colour code as per existing colour including removing all sticker/ rediam fixing new strickre as per existing
(ii) 160 KVA/200 KVA
(iii) 100 KVA/110 KVA/125 KVA (Total 10 Nos)
(iv) 62.5 KVA/ 63 KVA
(vi) 25 KVA/ 20 KVA
(vii) 18.75 KVA/ 15 KVA
(viii) 7.5 KVA/10 KVA
M & L for removing the fuel injection pump from D. G set capacity 100 to 320 KVA and carry out servicing & calibration from authorised service workshop including replaceement of injectors, Nozzles etc. and refitting the same for smooth and efficient functioning all as directed by Engr-in-Charge.
.-ditto- all as per Ser item No 11 but for 40 to 63 KVA
.-ditto- all as per Ser item No 11 above but 7.5KVA to 25 KVA
M & L for replacement of stater switch of DG set of capacity 63 to 320 KVA complete all as speciifed and directed
M&L for repair to radiator by disconnecting the radiator from engine frame and servicing / cleaning with acid and brazing where required to stop leaking tubes/joints etc. cleaning fins and re-fixing the same for D.G. set given below.:-
(i) 100 KVA to 320 KVA
(ii) 40 KVA to 63 KVA
(iii) 7.5 KVA to 25 KVA
M & L for repair of turbo charge by replacing repair kit & fixing same on D. G set 40 KVA to 320 KVA
Taking down the defective water pump fram D. G . Set & replace with new one for D. G. set. Of following capacities complete all as all directed by Engr-in-Charge.
(b) 200 KVA/160 KVA
(d ) 40 KVA to 63 KVA
(e) 7.5 KVA to 25 KVA
M & L for replacement of Egine Oil, 15W-40 complete all as specified and dierected
M & L for replacement of Coolant for Engine
M & L for replacement of Electrolyte of suitable spigravity for lead Acid batterries
M & L for replacement in distilled water for battery
M & L for replacement of fuel pipe steel braded with Benzo bolt & washer etc. of lenth 30 cm
M & L for replacement of fuel pipe steel braded with Benzo bolt & washer etc. of lenth 60 cm
M & L for replacement of fuel pipe steel braded with Benzo bolt & washer etc. of lenth 100 cm
Taking down the defective coupling at Exhaust mainfold end & fix new flexiable coupling stainless steel as per sample.
Taking down the existing perished/damaged asbestos rope and supply & replace with new asbestos rope 10 m. m thick on the exhaust pipe including covering with, complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of automatic voltage requlator 100 to 125 KVA D. G. set complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of automatic voltage requlator 160 to 200 KVA D. G. set complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of automatic voltage requlator 320 KVA D. G. set complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of automatic voltage requlator 20 to 63 KVA D. G. set complete all as specified and directed Engineer-in-Charge.
Supply battery leads set, PVC insulated multi stranded cooper 70 sq mm of 1.25 meter long each duly fixed with bran clamps.
M & L for replacement of brans battery terminal suitable for lead acid, battery 12 v any AH.
Supply & fixing in replacement digital ammeter 0 to 300 Amps.
Supply & fixing in replacement digital Voltmeter 0 to 500 Amps.
Supply & Fixing Engine Oil pressure gauge meter up to 7 kg complete all as specified and directed Engineer-in-Charge.
Supply & Fixing in replacement of Engine water temp. meter complete all as specified and directed Engineer-in-Charge.
Supply and fix in repairs change over switch existing panel, wall or LT pole of any size and any type off load type, triple pole and neutral, 100 Amps, 415 V, 50 Hz side handle operated, including connecting and testing all as directed Engineer-in-Charge.
.-ditto- all as per Ser item No 37 above but off load type, 125A side handle operated, including connected accssories complete all as specified and directed Engineer-in-Charge.
.-ditto- all as per ser item No 37 above but off load type, 200A side handle operated,
M & L For welding / brazing of silencer pipe of of DG Set
M & L for replacement of Door Hinges of various capacity of DG Set complete all as specified and directed.
M & L for replacement of Door lock of various capacity of DG Set as per existing at site of any capacity of adg set
S & F in replacement of Contractor MNX 225 2 No + 2 NC ,3 pole power contractor current rating AC 3 :225 Amp, AC1 :300 Amp or as per existing at site of capacity of DG set 100 to 160 KVA
S & F in replacement of MCCB 250 Amps, three pole, 25 KA complete all asspecified and directed by Enge in charge
S & F in replacement of Indicator lamp of colour (red,yellow,green) of DG set panel of any capacvity of dg set including all connecting circuit
Labour only for perodical maintenance , brake down on call repairs of EOT Crane 2 Ton long travel motor , cross travel motor , gear box , control panel etc. installed at armoured static work shop including dismaintling/replacing the unserviceable spair parts at site complete all as specified and directed. Note:- Rate includes greesing, cleaning, oiling etc.
.-ditto- all as per ser Item No 46 above but 2.5 Tons
.-ditto- all as per ser Item No 46 above but 3.5 Ton
.-ditto- all as per ser Item No 46 above but 10 Tons
All a.-ditto- all as per ser Item No 46 above but 25 Tons
M&L in replacement of following spare parts suitable for EOT Crane of capacity of 2.0 ton to 25 Ton.
(a) S&F Wheel with pin shaft
(b) S&F Ball bearing (Bearing No-6207)
(c ) S&F MS Gear for wheel
(d) S&F Steel wire rope multi stranded 10mm, Make Usha Martin
(e) S&F PVC Coated & PVC Insulated copper conductor multistranded of size 10 sqmm 4 core
(f) S&F HRC fuse link 32 amps as per site requirement
(g) S&F Gear box Oil EP -230
(h) S&F Brake Oil DOT4/3
(j) S&F Brake Shoe of 150mm dia
(k) S&F Magnetic Coil
(l) S&F Limit switch 3 phase 415 volt 50 Hz as per site requirement
(m) S&F Four Pole Contactor Ac Three phase 415volt Amps as per Site requirement
(n) S&F copper Carbon brushes for clutch for microw movement of EOT Crane
(o) S&F Current collector complete as per existing for EOT Crane of different capacity of EOT Crane
(p) S&F crane slider ACSR dog conductor wire rope used as a bus bar
M & L for replaceemnt of complete wiring of crane sliding panel and control panel using copper cable by using proper protective cover and necessary accessories of suitable size as per existing at site complete all as specified
Taking down and Material and labour for rewinding of electric motor 2HP/415,3HP/415volt,and 5HP/415 volt by using SE Copper wire same gauge and same turns incl varnishing heating, balancing etc from short travel/ long travel mechanism and refixing the same by replacing bearing, varnishing etc all as directed by Engr-in-Charge.
Taking down and Material for rewinding of electric motor 10HP/415 volt by using SE Copper wire same gauge and same turns incl varnishing heating, balancing etc from short travel/ long travel mechanism and refixing the same by replacing bearing, varnishing etc all as directed by Engr-in-Charge.
M&L for repairing to long travel shaft by replacing pedstal bearing 06 Nos, including machining work replacing nut, bolts ,washers all as directed by Engr-in-Charge. Note:- Rate of Pedastal Bearing is included in quated rate.
M&L for repair to brake system completely by replacing brake shoe , rotor, brake liner, spring for long travel, short travel, updown mechanism all as directed by engr-in-charge. Note:- Break shoes is measured and Paid Separately
Repairs to guide wheel 4 Nos for long Travels by replacing gun metal filling, reboring and machine work with in tolerance limit all as specified and directed.
Supply and fix in replacement of following Parts for Incenarator :-
(a) Ignition electrode, Cat Part No-HTT09/83
(b) Ignition Transformer 200-6000Volt, Cat Part No-HTT09/83
(c) Diffuser plate, Cat Part No-HTT06/83
(d) Solenoid Valve Cat Part No-VAL 0029/5
(e ) Fuel Pump Assembly Cat Part No-HT001/9
(f) Fuel Suction Filter assembly, Cat Part No-HA2/3
(g) Combution Blower Cat No-HTT 11/83
(h) Solenoid coil for combution blower, Cat Part No-VA-0320/9
(j) Sequence Controller, Cat Part No-HTT 22/G3
Supply and fix in repair of washing machine of following Parts :-
a) V Belt size A-69
b) HRC Fuse up to 32 Amps
d) Hose pipe for Drain 1.2 Mtr Length
e) Water Solinied Valve 1''
f) Conatctor 3 Phase 63 Amps for starter of main drive moter
g) Heating Contactor
j) Electric heater
k) Idler Shaft
l) sequence Controler
m) ignition Transformer
n) Air Filter Cum Regulator
o) Single Phase Prevainter
p) Drying Thumbler timer
q) Tension Spring
r) Breaking contactor
s) Display meter
t) Tub ball bearing washing machine
M & L for rewinding of 3 Phase universal electric motor including varnishing of washing machine main drive 3 HP incl taking down and reinstalling at site incl connecting electric point and commissioning complete al as specified.
M & L for periodical maint of Voltage stabilizer/ UPS of capacity upto 125 KVA once in three month which includes the following works. (i) check SVS working in auto mode (ii) Check battery terminals and clean (iii) Check input and output connection (iv) check Battery voltage (v) Ceck control card (vi) Check Driver card (vii) Check IGBT (viii) Check charger card
Supply and fix in repair voltage stabilizer/ups of following Parts :-
a) Control card for voltage stabilizer/ups as per existing at site of capacity 10/25 KVA
b) Control card for voltage stabilizer/ups as per existing at site of capacity 100/125 KVA
c) Driver card for stabilizer/ups as per existing at site
d) IGBT for stablizer
e) Charger card
M & L for Overhauling of voltage stabilizer complete by using spares part from OEM of capacity 125/100 KVA complete including dismantaling, removing the damagable/ unsv parts and reassembling, testing and commissioning the same complete all as specified and directed. Note : Spares parts will measured and paid by separately
a) S & F in replacement of Varic 40 Amps,single phase, 3 nos as per existing at site
b) S & F in replacement of Buck boost 100 Amps ,single phase for charging 12/24V service battery
c) S & F in replacement of Motor 10 kg /cm AC synchronous servo motor, RPM 60. for construction of voltage as per existing at site
d) S & F in replacement of control card for 125/100 KVA voltage stabiliser or existing as per site
e) S & F in replacement of contractor for 100/125 KVA stabiliser of existing capacity
f) S & F in gear assembly for 100/125 KVA stabilizer as per existing at site
M & L for Overhauling of voltage stabilizer complete by using spares part from OEM of capacity 10/25 KVA complete including dismentalling, removing the damagable/ unsv parts and reassembling, testing and commissioning the same complete all as specified and directed. Note : Spares parts will measured and paid by separately
a) S & F in replacement of Varic 8/12 Amps,single phase, 3 nos as per existing at site
b) S & F in replacement of Buck boost 40 Amps ,single phase for charging 12/24V service battery
c) S & F in replacement of Motor 3 kg /cm AC synchronous servo motor for construction of voltage as per existing at site
d) S & F in replacement of control card for 10/25 KVA voltage stabiliser or existing as per site
e) S & F in replacement of contractor for 10/25 KVA stabiliser of existing capacity
f) S & f in gear assembly for 10/25 KVA stabilizer as per existing at site
Supply and fix in repair following Parts for air compressor :-
a) V Belt suitable for Air compressor to motermain drive Pully
b) Compressed Air Pipe of 10mm Dia of Heavy Duty
c) Head Gas Ket
d) Piston Ring
e) Connecting Rod
f) Oil Seal
S & F DOL Starter of Air Compressor motor Main Drive 3 HP Incl taking down and reinstalling with new starter 415 volt 50 cycle current rating 8 Amps incl connecting to electric point and commissioning etc complete all as directed.
M & L for repair of AMF panel 160 KVA dg set by using following Parts :-
(a) AMF Controller
(b) Contactor 4 Pole 415 Volt 225 Amp, Make: L&T/Seimens
(c ) Bty Charger 24 Volt 20 Amp
(d ) Digital multifunctional meter for freq, Amp, Voltage, KWH
(f) Voltage Monitoring relay
Material and labour for replacement of unserviceable battery 12 V, 88 AH with maintenance free battery 12 Volt initially charged. Make - Exide
Material and labour for replacement of unserviceable battery 12 V, 180 AH with maintenance free battery 12 Volt initially charged. Make - Exide
Supply and fixing in existing panel board for replacement MCCB, 4 Pole, 63 Amps , with breaking capacity 16 KA , fixed type including spreaders and connecting accessories etc complete all as specified and directed by Engineer-in-Charge
Supply and fixing in existing panel board for replacement MCCB, 4 Pole, 100 Amps , with breaking capacity 25 KA , fixed type including spreaders of suitable size and connecting accessories etc complete all as specified and directed by Engineer-in-Charge
Material and labour for earthing complete with copper earth plate electrode 600 x 600 x 3.15 mm thick, buried vertically in ground (Each pit not less than 2.25 mtrs deep below normal ground level with top edge of plate not less than 1.50 M below normal ground level) connected to copper strip 20 x 3 mm, by means of bolts, nuts, and check nuts and washers etc encased in GI protection pipe 40 mm dia light grade pipe for protection of earth strip both to be provided to the extet of 7.5 meters, all as shown on electrical plate No 3 of MES SSR - 2009 Part - I, GI protection pipe buried in ground, laid under floors / plinths or mixed on walls / pole etc or concealed in walls etc; with provision of mixture of charcoal dust and common salt packed upto minimum 150 mm all around the earth plate, including PCC 1:2:4 type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with GI 20 mm dia medium grade pipe and MS funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of soil / strata and testing on completion complete all as specified and directed. Note:- i) Cost of GI strip 32 x 6 mm and protection pipe 40 mm dia is deemmed to be included in rate quoted ii) Excavation and returning filling of Soil any type is deemed to be included in rates.
M&L for earthing of poles/system with galvanised earth plate 60x60 cm x 6.30 mm thick electrode of size and 32 x 6mm GI strip buried vertically in ground not less than 2.25 mtr below ground level with top edge of the plate not less than 1.5 mtr below ground level and connected to copper strip dia by means of nuts, bolts and washers and encased in and including 40mm dia GI medium grade pipe upt 2.4 mtr height form ground level fixed by MS flat iron clamp 40mm x 5mm with nut, bolt and washers, GI strip fixed to base along pole and connected to over head line for providing earthing to HT pole/feeder AB switch LA complete with charcoal dust, salt packed around plate 150 mm thick including watering GI pipe, medium grade 20 mm dia with blanking cap 1.5 mtr long fixed to funnel with wiremesh complete with PCC chamber and RCC chamber over all as per Electrical Plate No 5 of SSR Part I - 2009 incl excavation and earth work in any type of starta and testing on compeltion etc complete all as specified and directed by Engineer-in-Charge (Note: Any length of GI strip and 40 mm dia GI medium grade pipe shall be provided as per actual requirement at site).
Shifting of DG set of any capacity from one place to another place within cantt area including dismantling of existing connection carefully and lifting, transporting with the help of crane and necessary transport and reassembling at new place including,reconnection same including testing with complete connection complete all as specified and directed etc
Supply and fixing in replacement of Solenoid switch as per existing at site for dg set of capacity 63 KVA to 100 KVA with complete manufacture connection and necessary items required etc all as speified and directed .
Supply and fixing in replacement of Solenoid switch as per existing at site for dg set of capacity 125KVA to 320 KVA with complete manufacture connection and necessary items required etc all as speified and directed .
Supply and fixing in replacement of LLOP as per existing at site for dg set of capacity 63 KVA to 200 KVA with complete manufacture connection and necessary items required etc all as speified and directed.
M & L for Overhauling of DG set complete by using spares part from OEM of capacity 7.5 to 40 KVA complete including dismantling, removing the damagable/ unsv parts and reassembling, testing and commissioning the same complete all as specified and directed. Note : Spares parts will measured and paid by separately
(a) S & F in replacement of Cylinder liner Assly complete all as specified and directed
( b) S & F in replacement of Pistion + Ring Assly complete all as specified and directed
(c) S & F in replacement of Set of Joints complete allas specified and direcetd
( d ) S & F replacement of Cylinder Head Gasket set of complete suitable for 25/40 KVA DG set complete all as specified and directed.
( e) M & L for Lub Oil Cooler complete all as specified and directed
(f) S & F in repalcement of Con Rod Bearing complete all as specified and directed
( g) S & F in replacement of Main Bearing set complete all as specified and directed.
( h) S & F in replacement of Lub oil pump complete all as specified and directed.
( i) S & F in replacement to Cam Bush set complete all as specified and directed.
(j) S & f in replacement to Cylinder Head Rep By Replacing inlet & Ex Valve complete all as specified and directed.
( k) S & F in replacement of Oil seal set complete all as specified and directed.
(l) S & F in repair/ replacement to Water pump Assly complete all as specified and directed
(m) S & F in replacement to Chamber Gasket complete all as specified and directed.
( n) S& F in replacement of Water pipe set all as specified and directed.
M & L for Overhauling of DG set complete by using spares part from OEM of capacity 63 to 125 KVA complete including dismantling, removing the damagable/ unsv parts and reassembling, testing and commissioning the same complete all as specified and directed. Note : Spares parts will measured and paid by separately
(a) S & F in replacement of Cylinder liner Assly complete all as specified and directed
(b) S & F in replacement of Pistion + Ring Assly complete all as specified and directed
(c) S & F in replacement of Set of Joints complete allas specified and direcetd
(d) S & F replacement of Cylinder Head Gasket set of complete suitable for 63 KVA DG set complete all as specified and directed.
(e) M & L for Lub Oil Cooler complete all as specified and directed
(f) S & F in repalcement of Con Rod Bearing complete all as specified and directed
(g) S & F in replacement of Main Bearing set complete all as specified and directed.
(h) S & F in replacement of Lub oil pump complete all as specified and directed.
(i) S & F in replacement to Cam Bush set complete all as specified and directed.
(j) S & f in replacement to Cylinder Head Rep By Replacing inlet & Ex Valve complete all as specified and directed.
(k) S & F in replacement of Oil seal set complete all as specified and directed.
(l) S & F in repair/replacement to Water pump Assly complete all as specified and directed
(m) S & F in replacement to Chamber Gasket complete all as specified and directed.
(n) S& F in replacement of Water pipe set all as specified and directed.
M & L for Overhauling of DG set colplete from OEM of capacity 160 to 200KVA complete including dismantling, removing the damagable/unsv parts and reassembling, testing and commissioning the same complete all as specified and directed. Note : Spares parts paid and measured by separately
(a) S & F in replacement of Cylinder liner Assly complete all as specified and directed
(b) S & F in replacement of Pistion and Ring Assly complete all as specified and directed
(c) S & F in replacement of Set of Joints complete allas specified and direcetd
(d) S & F replacement of Cylinder Head Gasket set of complete suitable for 125 KVA DG set complete all as specified and directed.
( e) M & L for Lub Oil Cooler complete all as specified and directed
(f) S & F in repalcement of Con Rod Bearing complete all as specified and directed
( g) S & F in replacement of Main Bearing set complete all as specified and directed.
( h) S & F in replacement of Lub oil pump complete all as specified and directed.
( i) S & F in replacement to Cam Bush set complete all as specified and directed.
(j) S & f in replacement to Cylinder Head Rep By Replacing inlet & Ex Valve complete all as specified and directed.
( k) S & F in replacement of Oil seal set complete all as specified and directed.
(l) S & F in repair/replacement to Water pump Assly complete all as specified and directed
(m) S & F in replacement to Chamber Gasket complete all as specified and directed.
( n) S& F in replacement of Water pipe set all as specified and directed.
M & L for Overhauling of DG set colplete from OEM of capacity 200 to 320 KVA complete including dismantling, removing the damagable/unsv parts and reassembling , testing and commissioning the same complete all as specified and directed. Note : Spares parts paid and measured by separately
(a) S & F in replacement of Cylinder liner Assly complete all as specified and directed
(b) S & F in replacement of Pistion and Ring Assly complete all as specified and directed
(c) S & F in replacement of Set of Joints complete allas specified and direcetd
(d) S & F replacement of Cylinder Head Gasket set of complete suitable for 25/40 KVA DG set complete all as specified and directed.
(e) M & L for Lub Oil Cooler complete all as specified and directed
(f) S & F in repalcement of Con Rod Bearing complete all as specified and directed
( g) S & F in replacement of Main Bearing set complete all as specified and directed.
( h) S & F in replacement of Lub oil pump complete all as specified and directed.
( i) S & F in replacement to Cam Bush set complete all as specified and directed.
(j) S & f in replacement to Cylinder Head Rep By Replacing inlet & Ex Valve complete all as specified and directed.
( k) S & F in replacement of Oil seal set complete all as specified and directed.
(l) S & F in repair/replacement to Water pump Assly complete all as specified and directed
(m) S & F in replacement to Chamber Gasket complete all as specified and directed.
( n) S& F in replacement of Water pipe set all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in hard dense soil etc complete all as specified and directed by Engineer-in-Charge
M & L for cement concrete type C2 (1:4:8)) using 20 mm graded stone aggregate in foundations, filling as mass concrete etc complete all as specified and directed by Engineer-in-Charge
Supply and fix in repair 50 x 50 x 6 mm thick angle iron frame flat iron 40 x6 mm cut length including drilling holes for fixing of nut and bolts to hold chain link fencing including painting with two coats of synthetic enamel paint over one coat of red oxide primer on all exposed surface complete all as specified and directed.
Supply and Fixing in repair of chain link fencing including line wires, any mesh, size dia 4 mm thick and steel wire mesh aperture 50 mm of standards, rails, straining bolts, etc.including provission of binding wire fixing 10 mm dia mild steel round bar to tighten chain link fencing including necessary hooking binding cutting etc complete all as specified and directed by Engineer-in-Charge
Supply and spreading in electrical outdoor installation yard, stone aggregate of size 20 mm Near DP structures after through cleaning, anti grass treatment etc all as per pecified and as directed.
M & L for aluminium cable lugs of size upto 50 sqmm flat head in Aluminium conductor/cable fixing with Nuts, bolts & washers to junction point as directed. (Note-To be measured only, fixed at places other than with heat shrink joints) Make - Dowells or equivalent.
M & L for aluminium cable lugs of size upto 70,95,120,150,185, 240,300 sqmm flat head in Aluminium conductor/cable fixing with Nuts, bolts & washers to junction point as directed. Make - Dowells or equivalent.
Supply and laying of bricks surrounding the stone aggregate at sub station including necessary excavation,returning and removing complete all as specified and directed.
M & L for reparing of Starter including rewinding of armature and replacement of field coil,commutator including carbun brush and overhauling complete all as specified and directed.
M & L for reparing of Alternator of existing capacity DG set including regulator,rectifier,rotor slip, rings and end bearing stator winding,drive end bearing and pully complete all as specifiedd and directed.
Repir/ Replacement of Alternator of capacity 160 to 200 KVA dg set by transporting to wksp and after repair fixing the same with proper alingment .Reapir work will carry following items complete all specified and directed.
a) Rewinding of Main Stater
b) Rewinding of Main Roter
c) Rewinding of Auxillary stater
c) Rewinding of Auxillary Roter
e) Bearing 2 Nos
Repir/ Replacement of Alternator of capacity 100 to 160 KVA dg set by transporting to wksp and after repair fixing the same with proper alingment .Reapir work will carry following items complete all specified and directed.
a) Rewinding of Main Stater
b) Rewinding of Main Roter
c) Rewinding of Auxillary stater
c) Rewinding of Auxillary Roter
e) Bearing 2 Nos
Repir/ Replacement of Alternator of capacity 7.5 to 63 KVA dg set by transporting to wksp and after repair fixing the same with proper alingment. Reapir work will carry following items complete all specified and directed.
a) Rewinding of Main Stater
b) Rewinding of Main Roter
c) Rewinding of Auxillary stater
c) Rewinding of Auxillary Roter
e) Bearing 2 Nos
M&L for fabrication of bus bar chamber of (size 500 x 500 x300 mm) suitable for 415 volts 3 phase 4 wire system , outdoor type, double door, provision space for one MCCB, with pedestal mounted, weather and vermin proof fabricated out of 3.15 mm thick MS CRCA sheet with anti corrosive coating & finally epoxy polyster powder coating of flint grey shade including 3 nos. phase indicating lamps, insertion of suitable cable glands for all incoming and out going cable including grouting of panel board 60 cm above & 30 cm below ground level duly supported on 50x50x6mm angle iron frame & welding 45 cm long angle iron legs of size 50x50x6mm on all the four corners embedded in PCC 1:2:4 using 20 mm stone aggregate upto 30 cm depth complete all as specified and directed by Engineer-in-Charge Comprising of 4 nos. Aluminium bus bar 100 Amp for phases & 50 Amp for neutral mounted on DMC/ porcelain insulator support complete all as specified and directed.Note: All MCCB Shall be Thermal and Magnetic adjustable type as per IEC 6047-II
M & L for fabrication of bus bar chamber of (size 500 x 500 x300 mm) suitable for 415 volts 3 phase 4 wire system, outdoor type, double door, provision space for one MCCB, with pedestal mounted, weather and vermin proof fabricated out of 3.15 mm thick MS CRCA sheet with anti corrosive coating & finally epoxy polyster powder coating of flint grey shade including 3 nos. phase indicating lamps, insertion of suitable cable glands for all incoming and out going cable including grouting of panel board 60 cm above & 30 cm below ground level duly supported on 50x50x6mm angle iron frame & welding 45 cm long angle iron legs of size 50x50x6mm on all the four corners embedded in PCC 1:2:4 using 20 mm stone aggregate upto 30 cm depth complete all as specified and directed by Engineer-in-Charge Comprising of 4 nos. Aluminium bus bar 200 Amp for phases & 50 Amp for neutral mounted on DMC/ porcelain insulator support complete all as specified and directed.Note: All MCCB Shall be Thermal and Magnetic adjustable type as per IEC 6047-II
Supply and fixing Air filter housing for DG set of capacity upto 100 kva including all fixing asseccories and connected item complete all as specified and directed.
Supply and fixing Air filter housing for DG set of capacity upto 100 kva to 200 kva including all fixing asseccories and connected item complete all as specified and directed.
Supply & Fixing and testing of LT cable 1100 volts grade, XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) ISI Marked with aluminium conductor suitable for earthed system of size 95 sq mm 3.5 core in trenches, on poles and in ducts complete all as specified and directed by Engr in charge. (Note :- Excavation & Earthwork, pipe protection should be measured and paid seprately under relevant item of this Schedule.)
Excavation in trenches nexc 1.5 mtr in depth and not exceeding 1.5 Mtr wide for laying of cable/pipe etc and getting out in any type of soil complete all as specified nad directed.
Returning filling in trenches excavated soil including spreading levelling watering and well ramming in layers n.exc 25 cm thick each layer as in soil complete all as specified nad directed..
Removing excavated materials n.exc 50 mtr depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified nad directed.
Supply & laying of HDPE pipe ISI mark of outer dia 63 mm polythylene with smooth internal and profiled external surface for non pressure under ground cable icluding coupler and bends etc complete all as specified and directed by Engineer-in-Charge Make : Supreme / Infra / Astral/Prince/jain irrigation
Supply and fixing Battery charger 24 Volt to DG set with proper electrical wiring as directed by Engineer-in-Charge.
Supply and fixing Battery charger 12 Volt to DG set with proper electrical wiring as directed by Engineer-in-Charge.
Note :- Schedule of Credit of Amount Rs. 44,559.00 shall be deducted from total amount.
Please Enable Macros to View BoQ information
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
TenderDOCUS8226.pdf
Tender Documents • 1.18 MB
BOQ_864114.xls
BOQ • 1.57 MB
Download all tender documents and submit your bid