Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 109 GROUND FLOOR RAHEMAT NAGAR GHASWALA ESTATE OPP GAURICINEMA RAKHIAL AHMEDABAD GUJARAT 380023 | AHMADABAD | GUJARAT | 380023 | Admitted-Finance |
| 2 | Admitted-Finance MUSTKIL 47 KHASRA NO 4 1 SIKRI PIYALA ROAD VILL SIKRI BALLABGARH FARIDABAD HARYANA 121004 | FARIDABAD | HARYANA | 121004 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance PLOT NO 50 1ST FLOOR STREET NO 6 RAILWAY LINE SITE ANAND PARBAT INDUSTRIAL ESTATE NEW DELHI CENTRAL DELHI DELHI 110005 | CENTRAL DELHI | DELHI | 110005 | Admitted-Finance |
Tender Value
₹28.4 L
EMD Value
₹56,700
Closing Date
14 Feb 2022, 4:00 pmClosed
ER. K.K. PADOTRA
Office of the Deputy General Manager, JKPCC Ltd., Unit Mechanical, Rail Head Complex Jammu.
Supply, Installation, Testing and Commissioning of Medical Gas pipeline system for OTs along with construction of manifold room at Indira Gandhi Govt. Dental Hospital Phase-II, Jammu.
2022_PWDJK_159394_3
e-NIT No. 28/MECH of 2021-22 Dt. 04-02-2022.
Open Tender
Miscellaneous Works
Item Rate
60 days
JAMMU
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,000
Yes
Financial Controller, JKPCC Ltd.
₹56,700
Yes
DY. G.M. JKPCC Mech Unit Jammu
22 Feb 2022
5 Feb 2022
15 Feb 2022
5 Feb 2022
14 Feb 2022
8 Feb 2022
8 Feb 2022
Amount
OXYGEN SYSTEM
Supplying, installation, testing and commissioning of Oxygen Manifol 6+6 cyclinder bank complete with NRV,Tail pipes
Supplying, installation, testing and commissioning of Fully Automatic Digital Control panel for oxygen with solenoid valve
Supplying, installation, testing and commissioning of Emergency Oxygen Manifold 3 cyclinder manifold with regulator,NRV,Tail pipe etc complete.
Supplying, installation, testing and commissioning of Oxygen Outlets with matching probes, BS Standard
Supplying, installation, testing and commissioning of Oxygen Flow meter with Humidfier Bottle BS Standard
Supplying, installation, testing and commissioning of low pressure tubing for flow meters with pipe end and probes BS Standard
NITROUS OXIDE SYSTEM
Supplying, installation, testing and commissioning of Nitrous Oxide Manifol 2+2 cyclinder bank complete with NRV,Tail pipes
Supplying, installation, testing and commissioning of Fully Automatic Digital Control panel for Nitrous Oxide with solenoid valve
Supplying, installation, testing and commissioning of Emergency Nitrous Oxide Manifold 1 cyclinder manifold with regulator,NRV,Tail pipe etc complete.
Supplying, installation, testing and commissioning of Nitrous Oxide Outlets with matching probes, BS Standard
Supplying, installation, testing and commissioning of high pressure tubing for flow meters with pipe end and probes BS Standard
VACUUM SYSTEM
Supplying, installation, testing and commissioning of vacuum Simplex system with a capacity of 980 LPM including 03 HP Motor to provide output with Bacteria filteration,complete in all respects with control panel and 500 ltr vacuum tank mounted with standard accessories.
Supplying, installation, testing and commissioning of Electric Control panel with single phase preventer with duplexing and auto cascading for Vacuum system
Supplying, installation, testing and commissioning of Vacuum Outlets with matching probes, BS Standard
Supplying, installation, testing and commissioning of Ward Vaccum unit with suction jar 600 ml and regulator
Supplying, installation, testing and commissioning of high pressure tubing for vaccum units with pipe end and probes.
COPPER PIPING
Supplying, installation, testing and commissioning of MEDICAL Grade BS EN: 13348, COPPER PIPE (certified by Lloyd's/TUV/SGS).
12mm (OD) x 0.7mm Thickness
15mm (OD) x 0.9mm Thickness
22mm (OD) x 0.9mm Thickness
28mm (OD) x 0.9mm Thickness
35mm (OD) x 1.0 mm Thickness
MEDICAL AREA LINE PRESSURE ALARM Supplying, installation, testing and commissioning of MEDICAL AREA LINE PRESSURE ALARM- CE certified ISO 13485 approved ,Area Line pressure Alarm-3 gases
MEDICAL AREA VALVE SERVICE UNIT Supplying, installation, testing and commissioning of Medical Area Valve Service Unit ( Valve Box ) CE certified ISO 13485 approved- 3 gases
ISOLATION LINE LOCABLE VALVES
Supplying, installation, testing and commissioning of Isolation liune locable valves:-
Construction of Manifold Room Construction of manifold room (RCC/Brick work) of required size suitable to accommodate all the BOQ items with sufficient space for operators movement inside the room.The manifold room should be costructed as per technical specifications and complete in all respects including providing fitting of 3 phase power connection, supply & fitting of required no of wiring,cabling,switches & plugs , Lights including supply from Mains upto Manifold room.
Comprehensive Annual Maintenance Contract(CAMC) for the complete system for a period of one year subsequent to the successful completion of warranty period
Note:- The measurable quantities may vary at the time of actual execution and shall be allowed and paid as per actual measurement within the estimated amount.
ASB System
M R Engg Works Pvt Ltd
Global Medilife Solution
amba steel & metal udyog
Ajay Electro Medical
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .