Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹19.5 LAccepted-AOC 205 PARSHAV VIHAR PLOT NO 50 IP EXTN PARPARGANJ DELHI 110092 | EAST | DELHI | 110092 | 1 | Accepted-AOC Lowest bidder | |
| 2 | 2₹20.2 L+₹34,834 (1.75%)Rejected-AOC | 2 | Rejected-AOC 2nd | |
| 3 | 3₹25.3 L+₹5.4 L (27.4%)Rejected-AOC | 3 | Rejected-AOC 3rd | |
| 4 | 4₹25.4 L+₹5.5 L (27.9%)Rejected-AOC | 4 | Rejected-AOC 4th | |
| 5 | 5₹26.0 L+₹6.1 L (30.9%)Rejected-AOC FLAT NO 93 POCKET 03 SECTOR 11 DWARKA NEW DELHI 110 075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | 5 | Rejected-AOC 5th |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
12 Feb 2022, 6:00 pmClosed
GE AF TUGHLAKABAD
GE AF TUGHLAKABAD SANGAM VIHAR PO NEW DELHI 110080
REPAIR/REPLACEMENT AND MAINT OF EXISTING LED POST LANTERNS, SECURITY/STREET LIGHT FITTINGS AND SOLAR STREET LIGHT OF PERIMETER INSIDE CAMP AND CONNECED UNDERGROUND CABLE WITH ALLIED WORKS AT BRD, AF STN NAJAFGARH UNDER GE (AF) TUGHLAKABAD
2021_MES_498368_1
GE/TKD/TOKEN-69/2021-22
Open Tender
Civil Works - Others
Item Rate
180 days
GE AF TUGHLAKABAD
MES contractor enlisted having deposited Standing Security with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category
8 documents required · 8 mandatory
₹500
GE AF TUGHLAKABAD
₹60,000
Yes
29 Mar 2022
14 Jan 2022
14 Feb 2022
21 Jan 2022
12 Feb 2022
28 Jan 2022
Amount
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep and getting out in soft/loose soil for laying of cable/foundation of pole and stay etc. complete all as specified and directed by Engr-in-charge.
M&L for sand cushioning in trenches for protection of LT underground cable including watering and consolidation complete all as specified and directed by Engr-in-charge.
Supply and lay well burnt sub class ‘B’ bricks, locally available of size 23x11.5x7.5 cm in trenches for protection of underground cable complete all as specified and directed by Engr-in-charge.
Removing the excavated materials to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above ground level from the starting point complete all as specified and directed by Engr-in-charge.
Returning filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed by Engr-in-charge.
M&L for drilling hole under hard standing/road for laying of pipe for protection of cable etc by means of mannual buckle and without distrubing the top surfaces and making good the disturbed surfaces if any complete all as specified and directed by Engr-in-charge.
Supply and lay GI pipe of light grade 40 mm bore complete all as specified and directed by Engr-in-charge.
Supply and lay GI pipe of light grade 80 mm bore complete all as specified and directed by Engr-in-charge.
Taking out old serviceable /unserviceable underground cable of any size from the excavated trenches /pipes complete all as specified and directed by Engr-in-charge. Note: Necessary earth work if any required will be measured and paid separately under relevant items.
Supply and lay or fixing or passing through pipe of XLPE (FRLS) with aluminium conductor cable with heavy duty stranded1100 volts of size 4 Sqmm 2 Core. Notes:- (i) XLPE insulated PVC sheathing (heavy duty) armoured cable with aluminium conductor for working pressure up to and including 1100 volts confirming to IS-7098 (Part-I) for PVC insulated cables with following features:- (a) Cable shall have fire retarded low smoke (FRLS) compound added to it in the out sheathing as per IEC 754(part-I) IEC-60332 part-2 IFEE 383 ASTM 2x43 and ASTM 2X63 flame retardant compound (PR) as per Engr-in-charge specification. (b) Inner sheathing shall be of extruded PVC. (c) Heat resisting PVC shall also be added to extrude inner and outer sheathing (d) Cable shall also be supplied with sequences hall marking at every meter as the outer sheathing. (e) Ultra violet radiation resistances compounded comprising ton ASTMG-53. (f) Anti rodent and anti termite compound to be added (g) PVC compounds of various grades as per IS-5831 (h) compaction of conductors shall be shaped and arrangement for the same will be on the cable. (ii) Each cable shall be tested for all applicable routine tests as per IS-5831,IS-7098 BS-6746,BS-5467 and IEC 60502 and test reports shall be provided to GE. (iii) Type of test as per relevant specification shall be produced Engr-in-charge. Make: Universal/Cable Corporation of India/Havells/Polycab/ Nicco
-Ditto- All as per item No 10 but of size 16 Sqmm, 4 Core.
-Ditto- All as per item No 10 but of size 240 Sqmm, 3½ Core.
-Ditto- All as per item No 10 but of size 300 Sqmm, 3½ Core.
Taking out old unserviceable street/flood light fitting of any capacity from existing pole
S&F LED security/street light fitting of 1 X30 W LED 5700K energy saving & environmental friendly long life versatile pressure die cast aluminium housing with acrylic cover as diffuser with IP 66 protection and impact resistance of IK 07 luminaire with high power LEDs as light source and electronic driver suitable for pole dia 40 mm including 45 mm dia light grade tube bracket, bend to shape 1.80mtr length with two Nos clamp of size 50mm x 6 mm with nut, bolts, washers etc including connection with 1.5 Sqmm two single core PVC insulated and PVC sheathed cable stranded Copper conductor upto ceiling rose and fixing on walls/pole complete as specified and as directed. Make: Cat No ENDURACITYLITEPLATPLUSSL30WLED 757SASBOPC of Havells /CG/Halonix
All as per Sl item No 15.00 but 60 Watt complete all as specified and directed by Engr-in-charge. Make: Cat No ENDURAPEARLNEOSL60WLED757PASYTOPC of Havells /CG/Halonix
All as per Sl item No 15.00 but 90 Watt complete all as specified and directed by Engr-in-charge. Make: Cat No ENDURAPEARLNEOSL90WLED757PASYTOPC ASTHO of Havells /CG/Halonix
M&L for JETA IRIS 100 W energy saving environmental friendly, long life exclusive innovative die-cast aluminium IP65 flood light with high power LEDs as light source, suitable for highlighting architectural features or retail spaces including taking out of old unserviceable one complete all as specified and directed by Engr-in-charge. Make: Cat No JETAIRISLS100WLED757APNBLTG of Havells /CG/Halonix
All as per sl item No 18 but 160 Watt complete all as specified and directed by Engr-in-charge. Make: Cat No JETAIRISLS160WLED757PNBLTG of Havells /CG/Halonix
M&L in replacement of steel tubular swaged oles with cast iron base plate, final taper plug, bolts, nuts & screws type 410 SP-31 (9.0 metre long) including fixing complete all as specified and directed by Engr-in-charge.
S&F non transparent looping SMC kiosks pole box 3 phase of size 310 x 210 x 120 mm made out of engineering plastic one piece moulding Siemens grey colour with hold fast including 4 Nos aluminium strips 60 amp of required size fixed on unbreakable insulator and one no single pole MCB 1 to 6 Amp, C curve including taking out of old unserviceable one complete all as specified and directed by Engr-in-charge.
S&F in replacement LED solar street light fitting of 40 Watt including galvanised steel pole in built, lithium ion battery, solar panel, charge controller with dusk down sensor complete all as specified and directed by Engr-in-charge. Note: (i) Excavation and earth work shall be measured and paid separately. (ii) Old fitting shall be taken over as credit only and Battery shall be depositted in AGE E/M Store yard.
M&L for preparation of old painted exposed surface of steel tubular LT poles 9 mtr long with street light brackets etc painting and numbering of poles with existing size and type by synthetic enamel paint as under:- (i) from bottom up to 1.2 mtr height one coat of black synthetic enamel high glow paint make berger. (ii) 1.2mtr to 1.30mtr height one coat of red & blue luminous paint/tape. (iii) 1.30 mtr height to top of the pole one coats of aluminium paint.
Taking down existing old LT panel board/ LT feeder pillar box comprising of MCCB & switch fuse unit of any capacity and size including bus bar, ammeters, voltmeters etc after disconnecting all cable connection and removing from site complete all as specified and directed by Engr-in-charge.
S&F street light panel / feeder pillar box of CPRI approved made out off MS/CRCA sheet 3.15 mm thick with MS angle iron frame of size 40x40x6mm outdoor type front door opening with locking arrangement slanting roof and size of panel /feeder pillar box is 0.6mx0.45m and 0.35 m without legs including necessary PCC cutting and fixing with PCC 1:3:6 of size 0.3mx0.3mx0.2m for 04 Nos legs including necessary insulators and 04 Nos copper bus bar of size 30mmx5mm capacity, provn of inlet and outlet cables with glands and earth connection lead etc complete and connection of all incoming and outgoing cable using aluminium terminal sockets/lugs duly crimpled and necessary two coats of paints with approved colour and grade of first quality synthetic enameled paint over a coat of red oxide primer including necessary preparation of surfaces all as specified and testing complete of the following :- (i) S&F MCCB 4 pole 415 volts 150 Amps 16 KA -01 No (ii) S&F modular indicator lamp LED type -01 set (R,B,Y) (iii) S&F timer switch type Alpharex 3D -21 astro of Legrand Cat No-412654 -01 No (iv) S&F 40 Amps TP power contractor of Legrand Cat No-412549 -01 No (v) S&F 32 Amps TPN MCB -01 No (vi) S&F 6-32 Amps SP MCB -06 Nos. (vii) S&F single phase preventer of L&T - 01 No
Disconnection the electric supply and dismantling the section of high mast 16/20 mtr height including fittings complete if required by manually / hydra at AF station Najafgarh for servicing, repair of gear motor and replacement of rope and chain etc and re-fixing the same after repair/replacement of above items and testing complete all as specified and directed by Engr-in-charge.
Supply and jointing indoor/outdoor cable end terminal joints/straight through heat shrinkable type complete suitable for aluminium conductor cable of size 2/4 Core upto 16 Sqmm complete all as specified and directed by Engr-in-charge.
All as per item No 27 above but for cable of size 35 Sqmm 3½ Core to 95 Sqmm 3½ Core.
All as per item No 27 above but for cable of size 10 Sqmm 3½ Core to 240 Sqmm 3½ Core.
All as per item No 27 above but for cable of size 10 Sqmm 3½ Core to 240 Sqmm 3½ Core.
Detecting the fault by fault locator machine of any size and type of HT/LT cable in 12 BRD including excavation, jointing by skill electrician, filling of soil and make good disturbed surface complete all as specified and directed by Engr-in-charge. Note: Jointing material will be measured and paid in respective items.
M&L for machine Spray painting to LT panel board with two coats of synthetic enamel paint including preparation/cleaning of steel surfaces and welding work as required complete all as specified and directed by Engr-in-charge.
M&L for PCC (1:3:6) type C2 by using 40 mm grade stone aggregate as in mass concrete for filling in foundation of stay/pole including necessary form work complete all as specified and directed by Engr-in-charge.
M&L for PCC (1:2:4) type B1 by using 20 mm grade stone aggregate as in coping of electric pole including necessary form work complete all as specified and directed by Engr-in-charge.
S&F aluminium thimble and lugs after disconnecting from the panel / Pole box and taking down the burnt cable from the panel /pole box on different locations and cutting out the burnt portion of cable and extended the cable from cable loop including necessary excavation, filling of soil, preparation of the cable and necessary connections, commissioning and testing complete all as specified and directed by Engr-in-charge for the following sizes :-
10 Sqmm 2 core 1100 volt grade
16 Sqmm 2/4 core 1100 volt grade
25 Sqmm 3.5 core 1100 volt grade
35 Sqmm 3.5 core 1100 volt grade
50 Sqmm 3.5 core 1100 volt grade
70 Sqmm 3.5 core 1100 volt grade
95 Sqmm 3.5 core 1100 volt grade
120 Sqmm 3.5 core 1100 volt grade
240 Sqmm 3.5 core 1100 volt grade
400 Sqmm 3.5 core 1100 volt grade
M&L in replacement timer switch single phase inbuilt over-ride facility, high switching capacity, tamper proof sealing, analog & digital version daily /weekly programming, supply voltage 240 VAC, frequency 50/60 Hz and electrical connection including taking down old one complete all as specified and directed by Engr-in-charge. Make : L&T Cat Part No J648F1/Havells/Legrand
S&F in replacement power contactor 3 pole, 265 Amp 415 volt, 50 Hz with control rated operational current AC1, 350 Model CH3 265 including taking down old one complete all as specified and directed by Engr-in-charge. Make : Havells Cat No IHPA265600 / L&T / Schnieder
S&F in replacement power contactor 3 pole, 330 Amp 415 volt, 50 Hz with control rated operational current AC1, 400 Model CH4 330T including taking down old one complete all as specified and directed by Engr-in-charge. Make: Havells Cat No IHPA265600 /L&T / Schnieder
S&F in replacement of On-Load Change over switch with advance neutral, front operated with sheet steel enclosure, 415 Volt, AC 50 Hz 400 Amp- 4 Pole complete all as specified and directed by Engr-in-charge. Make: Cat No IHCNF00400 of Havells/ ABB / Standard
S&F in replacement On-Load Change over switch with advance neutral, front operated with sheet steel enclosure, 415 Volt, AC 50 Hz 630 Amp-4 Pole complete all as specified and directed by Engr-in-charge. Make: Cat No IHCNF00630 of Havells/ ABB / Standard
S&F in replacement Off load Change over switch side handle with sheet enclosure, 415 Volt, AC 50 Hz 400 Amp-4 Pole complete all as specified and directed by Engr-in-charge. Make: Standard Cat Part No ISCNFFE0400/ Havells / ABB
S&F in replacement Off load Change over switch side handle with sheet enclosure, 415 Volt, AC 50 Hz 630 Amp-4 Pole complete all as specified and directed by Engr-in-charge. Make: Standard Cat Part No ISCNFFE0630/ Havells / ABB
Taking out of unserviceable MCCB s of any type any capacity by disconnecting all electrical connections from Panel board/wall /FPB all as directed at site complete all as specified and directed by Engr-in-charge.
S&F MCCBs including with Microprocessor release and necessary fitting arrangement & testing complete all as specified and directed by Engr-in-charge of following sizes.
63 Amps 4 Pole breaking capacity 16 KA.
100 Amps 4 Pole breaking capacity 16 KA.
160 Amps 4 Pole breaking capacity 36 KA.
250 Amps 4 Pole breaking capacity 36 KA
400 Amps 4 Pole breaking capacity 36 KA.
630 Amps 4 Pole breaking capacity 36 KA.
Parveen Builders
M/s R P Enterprises
M/s Prakash Enterprises
M/S PRADEEP ENTERPRISES
Surjit and Sons
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .