Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹24.5 LAccepted-AOC WARD NO 40 REGRON KA MOHALLA NEAR RAVI DASS JI MANDIR SHIV BARI BIKANER RAJSTHAN 334001 | BIKANER | RAJASTHAN | 334001 | ₹24.5 L | 1 | Accepted-AOC Lowest Accepted Bidder |
| 2 | 2₹25.9 L+₹1.5 L (5.94%)Rejected-AOC SHIV BARI ROAD NEAR KASUMAL HOTEL BIKANER 334003 RAJASTHAN | BIKANER | BIKANER | RAJASTHAN | 334003 | ₹25.9 L+₹1.5 L (5.94%) | 2 | Rejected-AOC Lowest Accepted Bidder is M/S B K Roy and Sons |
| 3 | 3₹29.1 L+₹4.7 L (19.1%)Rejected-AOC | ₹29.1 L+₹4.7 L (19.1%) | 3 | Rejected-AOC Lowest Accepted Bidder is M/S B K Roy and Sons |
Tender Value
₹34.7 L
EMD Value
₹69,360
Closing Date
17 Oct 2022, 6:00 pmClosed
Col Avik Saxena, CWE Bikaner
HQ CWE Bikaner, Mil Stn Bikaner, PIN-334001
Spl repair to HT panels, Feeder Pillar Box of Sub Station and connected works at Kanasar Mil Stn
2022_MES_553443_1
CA No. CWE BKN-Token No. 28/2022-2023
Open Tender
Miscellaneous Works
Item Rate
180 days
KANASAR
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE (P) Kanasar
₹69,360
Yes
1 Nov 2022
21 Sept 2022
24 Oct 2022
21 Sept 2022
17 Oct 2022
5 Oct 2022
21 Sept 2022 - 30 Sept 2022
Amount
Surface dressing not exceeding 15cm deep in soft/loose soil complete all as specified and as directed.
Excavating in trenches, not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exceeding 10 sqm on plan & not exceeding 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed.
Earth filling under floors, raised platform and similar locations including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed. Note :- Soil obtained from excavation under serial item No. 2.00 here-in-before shall be used for filling under this item.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil complete all as specified and directed.
Removing excavated soil/material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50 metre above the starting point complete all as specified and as directed.
M&L for PCC 1:4:8 type D2 using 40 mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed.
M&L for PCC 1:3:6 type C2 (using 40mm graded crushed stone aggregate) as in foundations, filling and mass concrete, base over hardcore of platform etc complete all as specified and as directed.
M&L for 100mm thick PCC (1:2:4) type B2 using 40mm graded crushed stone aggregate as in flooring, leveling course, top layer over platform, etc. surface finished fair and even, complete all as specified and as directed.
M&L for hardcore of broken stone or boulders, gauge not exceeding 63mm, deposited, spread and leveled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
M&L for brick work with old size burnt clay sub-class ‘B’ bricks, straight or curved on plan exceeding 6.00 metre mean radius, built in cement mortar 1:4 complete all as specified and as directed.
M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces of walls, finished even & smooth without using extra cement complete all as specified and directed.
Supply, install, testing and commissioning of HT 11KV, 3Phase, 50Hz, totally enclosed metal clad SF6 switchgear having rupturing capacity upto 630 Amps, Outdoor Non-Extensible Fixed Type (IP54), RMU (Ring main unit) 5-Way comprising of 03 Nos manually operated Load Break Switch and 02 Nos manual charging fixed-type Vacuum Circuit Breaker, inside robotically welded stainless steel grade 304 (Non Ferrite Non Megnetic Grade) tank having of minimum thickness 2.5mm with IP67 Degree of Protection and enhanced BIL of 75kVp internally to manage voltage surges and 01 Nos Air insulated metering panel. RMU should be provided with internal bus bars, as well as earthing bus bars of electrolytic grade copper, padlock provisions & complete with all accessories. The RMU shall be type tested for Internal arc test of AFL 21kA/1 sec for tank as per IEC62271-200. RMU shall have on-site-repairability features such as site replacable bushing/ coupling/ mechanism and gas refilling at site. The earthing bus bar shall be provided inside each cable compartment for solid earthing of cable sheilds. The outer hinged main door should cover entire front of switchgear including cable doors for providing fail-safe protection. The unit shall include the following with all necessary standard fittings as required at site. Make : ABB, Schneider, Siemens, Crompton (Serial item No. 12.00 Contd.....)
(Serial item No. 12.00 Contd.....) 02 Nos Breaker module consisting of following accessories : (01 No Incoming + 01 No outgoing) 11 kV, 630 Amp fixed-type Vaccum Circuit Breaker module for making and breaking of fault current alongwith disconnector + Earth Switch of full making capacity. Short time current - 21KA/ 3 sec, Making Capacity - 52kAp Auxiliary contacts - 1NO + 1NC Stored Enegry mechanism with manual spring-charging, associated closing/tripping coils, integrated non-removable spring-charging operating handle and ON/OFF push buttons mechanically latched to the mechanism Interlocked Cable box for front termination of the cable suitable upto 3 core 300sqmm, 11 KV XLPE cable with double-door arrangement (IP54+IP3X). Safety interlocked to prevent access to cable termination in live-condition. Right angle boots (push on type) Numerical based self-powered OC+EF Protection Relay, providing Over Current (min. setting 20%), Earth-Fault (min. setting : 10%) 03 Nos 100/1, 2.5VA epoxy insulated, Ring Core CTs for protection (Acc. Cl.5P10), installed away from bushings to prevent saturation of core. 03 Nos 100/1, 2.5VA epoxy insulated, Ring Core CTs for metering (Acc. Cl:1.0), installed away from bushings to prevent saturation of core. 01 Nos Digital Multifunction meter CL:1.0 Suitable site replacable cable bushings situated not beyond 300mm from cable-cover to allow ease of access for installation/ testing/ replacement purposes. Cable covers with self Interlocking mechanism between doors, earth switch, disconnector & VCB Capacitive voltage indication fixed type system Mechanical Indications for breaker ON, OFF, EARTH, TRIP, Spring Charged-Discharged (Serial item No. 12.00 Contd.....)
(Serial item No. 12.00 Contd.....) 03 Nos Outgoing Load Break Switch module consisting of following accessories : 11kV, 630 Amp Load Break Switch module and integrated earthing switch, both with full making capacity. Short time current - 21kA/3-sec, Making Capacity - 52 kAp Auxiliary contacts - 1NO + 1NC Fault Pass Indicator - 1 Nos for Incoming LBS Spring-assisted snap-action mechanism driven via shaft that remains un-inhibited after motorization, if required in future. Cable boxes with double-door arrangement for enhanced safety (IP54+IP3X) interlocked to prevent access to 3 core x 300 sqmm XLPE Aluminium cable termination in live-condition, Right angle boots (push on type) Suitable site replacable Cable bushings situated not beyond 300mm from cable-cover to allow ease of access for installation/testing/replacement purposes. Cable covers with self Interlocking mechanism with earth switch Capacitive voltage indication fixed type system as per IEC61243 (Serial item No. 12.00 Contd.....)
(Serial item No. 12.00 Contd.....) Air insulated metering module 12 kV, 630 Amp : Bushings outside cone interface for connection of external busbar - 01 Nos Coupling materials OD RMU to OD Metering - 01 Nos Single Phase potential transformer,Primary voltage: 11000 Volt Secondary voltage: 110V, 25VA, CL: 1.0, 3 Phase - 2 Sets. Space heater with thermostat control - 01 Nos Panel Illumination lamp - 1 Nos R Y B Indication- 1 Nos (i) Capacitive voltage indication fixed type VPIS 9-15 kV (ii) Necessay interclocking arrangement for safety and operations (iii) One No. Operationg Handle for Manual Operation and one no. manometer (iv) Safety Interlocks Shall be provided as per relevant IEC/IS Standards and Manufacturers directions (v) Above switchgear shall confirm to all relevant IEC/IS Standards. (vi) Vacuum interrupter should be of same make as RMU (vii) Cable bushing should be replacable at site. (viii) Minimum 5 module should accommodate in one tank to avoid multiple coupling at site.
Supply, install, testing and commissioning of HT 11 KV, 3 Phase, 50Hz, totally enclosed metal clad SF6 switchgear having rupturing capacity upto 630 Amps, Outdoor Non-Extensible Fixed Type (IP54), RMU (Ring main unit) 4-way comprising of 01 Nos manual charging fixed-type Vacuum Circuit Breaker & 03 Nos 630 Amps, manually operated Load Break Switch inside robotically welded stainless steel grade 304 (Non Ferrite Non Megnetic Grade) tank having minimum thickness 2.5mm with IP 67 Degree of Protection and enhanced BIL of 75kVp internally to manage voltage surges. RMU should be provided with internal bus bars, as well as earthing bus bars of electrolytic grade copper, padlock provisions & complete with all accessories. The RMU shall be type tested for Internal arc test of AFL 21kA/1 sec for tank as per IEC62271-200. RMU shall have on-site-repairability features such as site replacable bushing/ coupling/ mechanism and gas refilling at site. The earthing bus bar shall be provided inside each cable compartment for solid earthing of cable sheilds. The outer hinged main door should cover entire front of switchgear including cable doors for providing fail-safe protection. The unit shall include the following with all necessary standard fittings as required at site. Make : ABB, Schneider, Siemens, Crompton (Serial item No. 13.00 Contd.....)
(Serial item No. 13.00 Contd.....) 01 No incoming breaker module consisting of following accessories:- 11kV, 630 Amp fixed-type Vaccum Circuit Breaker module for making and breaking of fault current alongwith disconnector+Earth Switch of full making capacity Short time current - 21KA/ 3 sec, Making Capacity - 52kAp, Auxiliary contacts - 1NO + 1NC Stored Enegry mechanism with manual spring-charging, associated closing/tripping coils, integrated non-removable spring-charging operating handle and ON/OFF push buttons mechanically latched to the mechanism Interlocked Cable box for front termination of the cable suitable upto 3 core 300 sqmm, 11 KV XLPE cable with double-door arrangement (IP54+IP3X). Safety interlocked to prevent access to cable termination in live-condition. Right angle boots (push on type) Numerical based self-powered OC+EF Protection Relay, providing OverCurrent (min. setting 20%), Earth-Fault (minimum setting : 10%) 03 Nos 100/1, 2.5VA epoxy insulated, Ring Core CTs for protection (Acc. Cl.5P10), installed away from bushings to prevent saturation of core. Suitable site replacable cable bushings situated not beyond 300mm from cable-cover to allow ease of access for installation/ testing/ replacement purposes. Cable covers with self Interlocking mechanism between doors, earth switch, disconnector & VCB Capacitive voltage indication fixed type system Mechanical Indications for breaker ON, OFF, EARTH, TRIP, Spring Charged-Discharged. (Serial item No. 13.00 Contd.....)
(Serial item No. 13.00 Contd.....) 03 Nos Outgoing Load Break Switch module consisting of following accessories :- 11 kV, 630A Load Break Switch module and integrated earthing switch, both with full making capacity. Short time current - 21kA/3-sec, Making Capacity - 52kAp Auxiliary contacts - 1NO + 1NC Fault Pass Indicator - 1 No.for Incoming LBS Spring-assisted snap-action mechanism driven via shaft that remains un-inhibited after motorization, if required in future. Cable boxes with double-door arrangement for enhanced safety (IP54+IP3X) interlocked to prevent access to 3 core x 300 sqmm XLPE Aluminium cable termination in live-condition, Right angle boots (push on type) Suitable site replacable cable bushings situated not beyond 300mm from cable-cover to allow ease of access for installation/testing/replacement purposes. Cable covers with self Interlocking mechanism with earth switch Capacitive voltage indication fixed type system as per IEC61243 (i) Capacitive voltage indication fixed type VPIS 9-15 kV (ii) Necessay interclocking arrangement for safety and operations (iii) One No. Operationg Handle for Manual Operation and one no. manometer (iv) Safety Interlocks Shall be provided as per relevant IEC/IS Standards and Manufacturers directions (v) Above switchgear shall confirm to all relevant IEC/IS Standards. (vi) Vacuum interrupter should be of same make as RMU (vii) Cable bushing should be replacable at site. (viii) Minimum 5 module should accommodate in one tank to avoid multiple coupling at site.
M&L for cable jointing kit for 11 KV (Earthed) grade HT cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed.
M&L for cable jointing kit for 11 KV (Earthed) grade HT cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed.
Supply, laying and testing HT underground cable, (XLPE) insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium stranded conductor, 11000 Volts (Earthed) grade of cross-sectional area 95 Sqmm 3 core laid in trenches/ducts/through pipe in road crossings/ paths /drains /ducts /floors /along poles/ walls/ ceilings/ equipments etc. complete all as specified and directed. Notes:-(i) Necessary excavation and earth work, brick protection, sand cushioning and cover and GI pipe shall be measured and paid for separately. (ii) Road cutting / floor cutting/cutting hole etc in wall required for laying/fixing of cable etc shall be made good as per existing site condition. Nothing extra shall be admissible on this account and quoted rate for this item shall be deemed to include for the same.
Supplying and laying un-reinforced precast concrete cable cover, Class HV, Type I, flat, size 300 mm x 180mm x 40mm confirming to IS -5820 complete all as specified and as directed.
M&L for sand cushioning (Local Tibba sand) to underground cable provided with a layer of 8cm deep before laying cable and 15cm after laying of cable and punned to 18cm after laying of cable and cover for protection of underground cable complete all as specified and directed. Notes:- (i) Approved local tibba dry sand free from vegetations, grass and other deleterious substances shall be used. (ii) For the purpose of payment only punned thickness shall be measured.
M&L for preparation of newly plastered / unplastered surfaces of walls & applying three coats of white wash complete all as specified and directed.
M&L for Earthing to Transformer / GOD switch / equipments / panels etc with & including galvanised mild steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the earth plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to & including galvanized mild steel strip 32x6 mm as earth lead, including nuts, bolts, check nuts & washers of galvanized iron or steel and riveted/welded to earth plate at one end and other end of strip connected to transformer / GOD / Panel / equipment body / test point with two Nos nuts bolts or welding with steel structure, GI earth strip encased in and including 40mm bore GI light grade pipe with all fittings from upper edges of earth plate upto 7.5 metre above ground level fixed with and including 25x3mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from earth pit to top of electrode and including funnel, wire mesh, copper lugs etc complete with earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover complete all as specified and shown in electrical plate No 3 of SSR Part-I including necessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exc 50m complete all as specified and as directed. Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner.
M/s Rohit Construction Co.
M/s Chopra Associates
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .