Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.0 LAccepted-AOC R O IQBAL MARKET AALI MAJID EIDGAH SRINAGAR KASHMIR | SRINAGAR | JAMMU AND KASHMIR | 190001 | L1 | Accepted-AOC ACCEPTED BEING L1 | |
| 2 | L2₹5.4 L+₹46,015 (9.24%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹5.6 L+₹56,900 (11.4%)Rejected-Finance GUDSATHU BUDGAM KASHMIR 191111 J K | BUDGAM | BUDGAM | JAMMU AND KASHMIR | 191111 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹5.6 L+₹60,020 (12.0%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹6.4 L+₹1.4 L (29.0%)Rejected-Finance FIRDOUS ABAD BATMALOO SRINAGAR PIN 190004 J K | SRINAGAR | SRINAGAR | J K | 190004 | L5 | Rejected-Finance Other than L1 |
Tender Value
₹7 L
EMD Value
₹14,000
Closing Date
25 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) CIF (K)
AGE (I) CIF (K) SHALATENG
REPAIR AND MAINT OF LT EXTERNAL ELECTRIC WORK, LT PANELS AT HQ 10 SECT AND 29 RR AT PATTAN GARRISON UNDER AGE (I) CIF(K)
2022_MES_527059_1
CA NO. AGE (I) CIF (K)- 37/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
SHALATENG
AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
AGE (I) CIF (K)
₹14,000
Yes
5 Jul 2022
28 May 2022
27 Jun 2022
28 May 2022
25 Jun 2022
11 Jun 2022
60 days
Amount
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for laying of cable and foundation of poles, stays etc. and getting out in any type of soil, complete all as specified and directed by the Engineer-in-Charge.
Excavation in trenches not exceeding 1.5 metre wide and depth exceeding 1.5 metre and not exceedig 3 metre for laying of cable and foundation of poles, stays and getting out in any type of soil, complete all as specified and directed by the Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each layer in any type of soil complete all as specified and as directed by Engineer-in-Charge.
Removing excavated material not exceeding 50metre and depositing where directed at a level not exceeding 1.5metre above the starting point, complete all as specified and as directed by Engineer-in-Charge.
Sand cushioning to underground cable, provided with a layer 8 cm before and 15 cm after laying and stretching jointing and testing the cable, complete all as specified and directed by Engineer-in-Charge. Note: Punned thickness of sand shall be measured.
Common burnt sub class ‘B’ brick laid flat in trenches over and across the length of cable with length of brick perpendicular to the direction of cable adjacent/abutting each other for cable protection, complete all as specified and as directed by Engineer-in-Charge.
Plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation of poles/struts, filling and mass concrete including necessary form work, complete all as specified as directed by the Engineer-in-Charge.
Providing and laying plain cement concrete 1:3:6, type C-1, using 20mm graded crushed stone aggregate, as in coping around poles including necessary form work and fair finishing of exposed surfaces without using extra cement , complete all as specified and as directed by the Engineer-in-Charge.
Supplying, laying, jointing and testing XLPE insulated, sheathed, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 6 Sqmm, 2 core in trenches, on poles, through pipes, fixed to wall, under culvert or in air etc, including taking out/down and removing old unserviceable existing cable, complete all as specified and as directed by the Engineer-in-Charge. Note: Neceesary Earth work shall be measured and paid for separately under respective item of this BOQ.
Supplying, laying, jointing and testing XLPE insulated, sheathed, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 Sqmm, 2 core in trenches, on poles, through pipes, fixed to wall, under culvert or in air etc, including taking out/down and removing old unserviceable existing cable, complete all as specified and as directed by the Engineer-in-Charge. Note: Neceesary Earth work shall be measured and paid for separately under respective item of this BOQ.
Supplying, laying, jointing and testing XLPE insulated, sheathed, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 Sqmm, 2 core in trenches, on poles, through pipes, fixed to wall, under culvert or in air etc, including taking out/down and removing old unserviceable existing cable, complete all as specified and as directed by the Engineer-in-Charge. Note: Neceesary Earth work shall be measured and paid for separately under respective item of this BOQ.
Supplying, laying, jointing and testing XLPE insulated, sheathed, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 Sqmm, 4 core in trenches, on poles, through pipes, fixed to wall, under culvert or in air etc, including taking out/down and removing old unserviceable existing cable, complete all as specified and as directed by the Engineer-in-Charge. Note: Neceesary Earth work shall be measured and paid for separately under respective item of this BOQ.
Supplying, laying, jointing and testing XLPE insulated, sheathed, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 Sqmm, 4 core in trenches, on poles, through pipes, fixed to wall, under culvert or in air etc, including taking out/down and removing old unserviceable existing cable, complete all as specified and as directed by the Engineer-in-Charge. Note: Neceesary Earth work shall be measured and paid for separately under respective item of this BOQ.
Supplying, laying, jointing and testing XLPE insulated, sheathed, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 Sqmm, 3.5 core in trenches, on poles, through pipes, fixed to wall, under culvert or in air etc, including taking out/down and removing old unserviceable existing cable, complete all as specified and as directed by the Engineer-in-Charge. Note: Neceesary Earth work shall be measured and paid for separately under respective item of this BOQ.
Supplying, laying, jointing and testing XLPE insulated, sheathed, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 Sqmm, 3.5 core in trenches, on poles, through pipes, fixed to wall, under culvert or in air etc, including taking out/down and removing old unserviceable existing cable, complete all as specified and as directed by the Engineer-in-Charge. Note: Neceesary Earth work shall be measured and paid for separately under respective item of this BOQ.
Supplying, laying, jointing and testing XLPE insulated, sheathed, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 70 Sqmm, 3.5 core in trenches, on poles, through pipes, fixed to wall, under culvert or in air etc, including taking out/down and removing old unserviceable existing cable, complete all as specified and as directed by the Engineer-in-Charge. Note: Neceesary Earth work shall be measured and paid for separately under respective item of this BOQ.
Supplying, laying, jointing and testing XLPE insulated, sheathed, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 95 Sqmm, 3.5 core in trenches, on poles, through pipes, fixed to wall, under culvert or in air etc, including taking out/down and removing old unserviceable existing cable, complete all as specified and as directed by the Engineer-in-Charge. Note: Neceesary Earth work shall be measured and paid for separately under respective item of this BOQ.
Supplying, laying, jointing and testing XLPE insulated, sheathed, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 120 Sqmm, 3.5 core in trenches, on poles, through pipes, fixed to wall, under culvert or in air etc, including taking out/down and removing old unserviceable existing cable, complete all as specified and as directed by the Engineer-in-Charge. Note: Neceesary Earth work shall be measured and paid for separately under respective item of this BOQ.
Supplying, laying, jointing and testing XPLE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 150 Sqmm, 3.5 core in trenches, through pipe, under culvert or in air including taking out/down and removing old unserviceable existing cable , complete all as specified and as directed by Engineer-in-Charge. Note: Neceesary Earth work shall be measured and paid for separately under respective item of this BOQ.
Supplying, laying, jointing and testing XPLE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 185 Sqmm, 3.5 core in trenches, through pipe, under culvert or in air including taking out/down and removing old unserviceable existing cable, complete all as specified and as directed by Engineer-in-Charge. Note: Neceesary Earth work shall be measured and paid for separately under respective item of this BOQ.
Shackle type porcelain,vitreous,white or brown or green insulator for working pressure 1100 volts of 90 mm dia and 100 mm height ,incld galvanised mild steel straps of 21x35 mm size including 12 mm dia insulator bolts,washers and nuts,including taking down old insulators of any type ,shape and size and removing from site, complete all as specified as directed by the Engineer-in-Charge.
Pin type porcelain,vitreous,white or brown or green insulator large size overall dimensions 65x100 mm clearance of hole 25.50 mm for working pressure 1100 volts bolts,nuts and washers incld taking down old insulators of any type ,shape and size and removing from site, complete all as specified as directed by the Engineer-in-Charge.
Replacement of existing LT Spacers with new LT Spacers 4 Ways,made out of PVC material and suitable for working on 1100 volts, complete all as specified as directed by the Engineer-in-Charge.
Replacement of existing LT Spacers with new LT Spacers 2 Ways,made out of PVC material and suitable for working on 1100 volts, complete all as specified as directed by the Engineer-in-Charge.
Replacement of existing worn out/over heated/multi jointed ACSR jumpers of LT overhead lines with PVC insulated 1100 volts cable of size 50 Sqmm , complete all as specified as directed by the Engineer-in-Charge. Note :- Length of one jumper shall be 1.5 mtr (appx)
ACSR Conductor for LT lines on steel tubular poles,stretching without kinks and bends including bending wire,jumpering ,maintaining proper sag as per IE Rule including cutting of tree branches around the ACSR within 5metre dia , including taking down old conductor of any type ,shape and size and removing from site, complete all as specified as directed by the Engineer-in-Charge.
Steel tubular swaged pole erected to truly vertical or planted as strut complete with 6mm thick cast iron/mild steel base plate continuously welded to pole, finial taper plug, bolts, nuts and screws, poles made out of ERW MS tubing conforming to IS-2713 Part-II as specified type 410 SP–31 (09 metre long) including drilling of holes of required size for fixing of cross arms and applying two coats of bituminous paint internally throughout and externally for embedded portion and with two coats of aluminum paint superior quality of approved make on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with yellow and black paint alternately on external surface above PCC benching/coping externally including taking down old existing , complete all as specified as directed by the Engineer-in-Charge. Note: Necessary earth work, PCC foundation and coping will be measured and paid for separately under respective items.
Painting of existing Steel Tubular LT Poles 9 mtr long, including cross arms,channels,angle iron support,bracing ,clamps,GI Bracket etc by applying two coat of aluminium paint superior quality of approved make on exposed surface and making 30 cm wide strips(Total 5 Nos) with yellow and black paint alternately on exposed surface above PCC bedding incl preparation of old surface after scraping/brushing old paint and cleaning the rust on poleand cross arms, complete all as specified as directed by the Engineer-in-Charge.
Numbering of poles with synthetic enameled black paint in yellow circle of 150mm dia ,complete all as specified as directed by the Engineer-in-Charge. Note:- The numbering shall be hand written only. Stencils embossing shall not be allowed and size of letter shall be 50 x 10 mm (height x width ).
Painting LT panel after taking proper shut down by applying two coats of smoke grey paint after preparation of surfaces by scraping,clleaning of surface ,writing feeder name with black paint with letter of size 50 x10 mm (Height X Width) including painting of angle iron frame, complete all as specified as directed by the Engineer-in-Charge.
Structural steel work as in Cross Arms, bracing ,supports,clamps and back plates fabricated from structural sections incl nuts,bolts,washers,bending hot or cold ,drilling holes for bolts ,in any shape or size as indicated or directed and applying two coats of aluminium paint over one coat of red oxide primer incl preparation of surfaces complete and dismantling old cross arms and removing from site, complete all as specified and directed by the Engineer-in-Charge.
Restreching of ACSR Conductor and earth wire of any size and type on LT Poles including disconnection and re-binding with insulators with suitable size of binding wire after restretching connecting jumpers,adjusting line dividers etc and cutting trimming of tree branches upto 1 mtr clear distance from wire, complete all as specified and directed by the Engineer-in-Charge.
Galvanized iron tubing 100mm bore light grade with all fittings,laid in trenches or under road crossing , or fixed alongwith poles/walls with clamps made of mild steel flat iron 25mm x 3mm including GI nuts, bolts and washers as protection pipe for cables and including taking down/out old existing pipe, complete all as specified and directed by the Engineer- in-Charge.
Galvanized iron tubing 80mm bore light grade with all fittings,laid in trenches or under road crossing , or fixed alongwith poles/walls with clamps made of mild steel flat iron 25mm x 3mm including GI nuts, bolts and washers as protection pipe for cables and including taking down/out old existing pipe, complete all as specified and directed by the Engineer- in-Charge.
Galvanized iron tubing 50mm bore light grade with all fittings,laid in trenches or under road crossing , or fixed alongwith poles/walls with clamps made of mild steel flat iron 25mm x 3mm including GI nuts, bolts and washers as protection pipe for cables and including taking down/out old existing pipe, complete all as specified and directed by the Engineer- in-Charge.
Galvanized iron tubing 40mm bore light grade with all fittings,laid in trenches or under road crossing , or fixed alongwith poles/walls with clamps made of mild steel flat iron 25mm x 3mm including GI nuts, bolts and washers as protection pipe for cables and including taking down/out old existing pipe, complete all as specified and directed by the Engineer- in-Charge.
Replacement of existing Moulded Case Circuit breaker with new Moulded Case Circuit breaker 250 Amps, 35/36 KA of Capacity 415 V 50 Hz, 04 Pole to be fixed on existing LT Panel. , complete all as specified and directed by the Engineer-in-Charge.
Replacement of existing Moulded Case Circuit breaker with new Moulded Case Circuit breaker 200 Amps, 35/36 KA of Capacity 415 V 50 Hz, 04 Pole to be fixed on existing LT Panel. , complete all as specified and directed by the Engineer-in-Charge.
Replacement of existing Moulded Case Circuit breaker with new Moulded Case Circuit breaker 160 Amps, 35/36 KA of Capacity 415 V 50 Hz, 04 Pole to be fixed on existing LT Panel. , complete all as specified and directed by the Engineer-in-Charge.
Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.30 mm thick buried directly in ground vertically in a pit of depth not less than 2.25 metre below ground levels with top edge of the earth plate not less than 1.50 metre below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanized iron strip, 32 x 6 mm earth lead by means of bolts, nuts check nuts and washers of galvanised steel, 40 mm bore (light grade) GI pipe for protection of earthing lead and GI pipe light grade 20 mm dia bore for watering funnel with wire mesh including provision of concrete pit in plain cement concrete 1:2:4, type B-1 using 20mm graded crushed stone aggregate with 40 mm thick cover of reinforced cement concrete 1:2:4, type B-I, using 20 mm graded crushed stone aggregate, reinforced with XPM weight not less than 4 Kg /Sqm and frame of angle iron 25 x 25 x 6mm with lugs 02 Nos and with 6mm dia MS bar handle made to shape ,excavation and earth work in any type of soil, returning filling in and removal of surplus soil including testing including testing on completion, complete all as specified and and shown in electrical plate No 3 of MES Schedule 2009 Part-I, complete all as specified and as directed by the Engineer-in-Charge. Note:- Earthing to be done for replacement of existing earthing. The materials retrieved from earthing shall be credited to contractor.
Earthing complete with and including galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick surrounded by a mixture of charcoal and salt in alternate layers burried directly in ground vertically in a pit of depth not less than 2.25 m deep below ground level with top edge of earth plate at a depth of not less than 1.5 m below ground level, connected with and including galvanised iron wire earth lead, 4mm dia (No. 8 SWG) by means bolts, nuts, check nuts and washers made out of galvanised iron, 15 mm bore (light grade) GI pipe for protection of earthing lead, 20 mm bore (light grade) GI pipe for watering with funnel, wire mesh including provision of concrete pit in plain cement concrete 1:2:4, type B-1 using 20mm graded crushed stone aggregate with 40 mm thick cover of reinforced cement concrete 1:2:4, type B-I, using 20 mm graded crushed stone aggregate, reinforced with XPM weight not less than 4 Kg /Sqm and frame of angle iron 25 x 25 x 6mm with lugs 02 Nos and with 6mm dia MS bar handle made to shape ,excavation and earth work in any type of soil, returning filling in and removal of surplus soil including testing including testing on completion, complete all as specified and and shown in electrical plate No 3 of MES Schedule 2009 Part-I, complete all as specified and as directed by the Engineer-in-Charge. Note:- Earthing to be done for replacement of existing earthing. The materials retrieved from earthing shall be credited to contractor.
Street light junction box made out of 2 mm thick MS sheet of size 250 x 200 x 150 mm incl 04 nos aluminium busbar of size 20 x 3 mm thick mounted on porcelain insulators and one MCB SP 6 amps etc having provn of cable glands for incoming and outgoing cables, fixed to pole with proper fixing arrangement and painting, complete all as specified and directed by the Engineer-in-Charge.
Supply and filling transformer oil of BDV not less than 50 KV for topping up or ltrs reduced level of transformer oil due to evaporation /leakage/ loses due to dehydration to distribution transformer of different capacity, complete all as specified and as directed by the Engineer-in-Charge. Make of transformer oil: Savita/ Power/Gulf ,
Conducting oil filtration by stream line type filter machine to improve BDV upto 70 KV including routine testing after filtration, complete all as specified and as directed by the Engineer-in-Charge.
Dismantling existing unserviceable stay assembly and supply and fix new stay assembly comprising of the following, complete all as specified and as directed by the Engineer-in-Charge.:- i) Necessary excavation and earthwork for pit of size 120x60x120 cm. ii) PCC(1:4:8) as in foundation concrete for stay assembly iii) Stay Rod 16 mm dia,180 cm long iv) Stay plate of size 23cmx23cmx6mm v) Stay Bow vi) Stay wire GI Stranded of size 7/4 mm,not exceeding 7.50 m with each stay vii)Stay Clamp at top of Pole of MS Flat of size 50x6 mm ,including two Nos of nut and bolts of size 75x15 mm viii) Loop type insulator ,porcelain,vitreous ,white ,brown or green large size of 90x140 mm clearance of hole 25 mm
Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP66 flood light with high power LEDs as light source, suitable for highlighting architecural facade highmast and general purpose lighting including 120 watt 5700 K LEDs including taking down old fitting,complete all as specified and as directed by the Engineer-in-Charge Make :- Havells Cat Part No. JETAIRISFL120WLED757ARWBLTG or equivalent in Bajaj/Philips
LED street light fittinngs 35 watt 230V AC outdoor type with high pressure die cast alumium hosing and heat resistant complete with driver,lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection including taking down old fitting, complete all as specified and directed by the Engineer-in-Charge. Make : Havells Cat part No ENDCITYLITPLAT + SL35WLED757SASYBOPCWOSPD or equivalent in /Bajaj/Philips
LED street light fittinngs 60 watt 230V AC outdoor type with high pressure die cast alumium hosing and heat resistant complete with driver,lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including taking down old fitting, complete all as specified and as directed by Engineer-in-Charge. Make : Havells Cat part No ENDURAPEARLNEOSL60WLED757 PASYTOPCAST or equivalent in /Bajaj/Philips
Supplying, laying, jointing and testing 1100 volts grade PVC insulated heavy duty armoured multistranded aluminium conductor,served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular 10sqmm 2 core, complete all as specified and directed by the Engineer-in-Charge.
Supplying, laying, jointing and testing 1100 volts grade PVC insulated heavy duty armoured multistranded aluminium conductor,served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular 16sqmm 2 core, complete all as specified and directed by the Engineer-in-Charge.
Galvanized iron tubing 40mm bore, light grade, 1.20 metres long, bent to shape required, as in street light brackets, fixed to poles/ walls with suitable size MS clamps, nuts & bolts complete, fixed in repairs incl taking down old one, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing lugs or thimbles of size 25 Sqmm to 70 sqmm aluminum, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing lugs or thimbles of size 95 Sqmm to 150 sqmm aluminum, complete all as specified and directed by Engineer-in-Charge.
Supply ,installation ,testing and commisioning against replacement weather and vermin proof LT feeder pillar box factory fabricated,outdoor cubicle/kiosk type totally enclosed outer cage motor made out of 3.15 mm thick sheet metal and inner compartments of 2.0 thick sheet metal enclosure with angle iron frame of MS angle 50x50x6 mm suitable foroperation on 3 phase 4 wire 440V,50 Hz system with hinged panel doors (covers) on two sides with handles ,bottom gland plate and locking arrangement consisting of sufficient Nos of Circular cable entry holes at bottom only with suitable PVC/rubber bushes to prevent ingress of water/vermin etc inside the closure ,the required Nos of holes to be fixed with chromium plated brass glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size ,duly powder coated internally/externally of approved colour with PCC Foundation and Aluminium Bus bar for 3 phase & neutral mounted on epoxy insulator -01 Set including connecting the following:-
Supply ,installation ,testing and commisioning against replacement weather and vermin proof LT feeder pillar box factory fabricated,outdoor cubicle/kiosk type totally enclosed outer cage motor made out of 3.15 mm thick sheet metal and inner compartments of 2.0 thick sheet metal enclosure with angle iron frame of MS angle 50x50x6 mm suitable for operation on 3 phase 4 wire 440V,50 Hz system with hinged panel doors (covers) on two sides with handles ,bottom gland plate and locking arrangement consisting of sufficient Nos of Circular cable entry holes at bottom only with suitable PVC/rubber bushes to prevent ingress of water/vermin etc inside the closure ,the required Nos of holes to be fixed with chromium plated brass glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size ,duly powder coated internally/externally of approved colour with PCC Foundation and Aluminium Bus bar for 3 phase & neutral mounted on epoxy insulator -01 Set including connecting the following:-
Note :- An amount of Rs. 41,680.00 on account of credit schdule for Sch 'A' Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum.
M/S ZAHOOR ENTERPRISES
JK BUILDERS AND ENGINEERS
M/S YATTOO CONTRACTORS
VEDA INFRASTRUCTURE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .