Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹59.4 CrAccepted-AOC | ₹59.4 Cr | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹61.6 CrRejected-Finance | ₹61.6 Cr | L2 | Rejected-Finance Rejected |
| 3 | L3₹63.4 CrRejected-Finance SCF 126 OPP SUKHRAJ CINEMA ROSE GARDEN COMPLEX G T ROAD BATHINDA PUNJAB 151001 | BATHINDA | PUNJAB | 151001 | ₹63.4 Cr | L3 | Rejected-Finance Rejected |
| 4 | L4₹65.3 CrRejected-Finance | ₹65.3 Cr | L4 | Rejected-Finance Rejected |
| 5 | L5₹67.2 CrRejected-Finance | ₹67.2 Cr | L5 | Rejected-Finance Rejected |
Tender Value
₹59.6 Cr
EMD Value
₹15 L
Closing Date
8 Mar 2025, 6:00 pmClosed
CE Bathinda Zone
Headquarters Chief Engineer Bathinda Zone Bathinda Mil Stn-151004
PROVN OF OTM ACCN (PH I OF TWO PHs) FOR AD REGT AND ITS AFFILIATED WKSP AT BATHINDA MIL STN Job No SW 210
2024_MES_690828_1
CE BTZ/BTD/TOKEN-18 OF 2024-25
Open Tender
Civil Works
1095 days
GE (P) Bathinda
As per NIT
9 documents required · 9 mandatory
₹3,000
GE (P) Bathinda
₹15 L
Yes
3 Apr 2025
28 Dec 2024
15 Mar 2025
28 Dec 2024
8 Mar 2025
18 Feb 2025
Amount
Lump sum price worked out by the tenderer for “BUILDING /STRUCTURE WORKS" as listed in Schedule ‘A’ Section - I
Sch 'A' Section- II, INTERNAL ELECTRIFICATION WORKS AND FLAME PROOF FITTINGS
Material and labour for concealed Point wiring for one light point/fan point controlled by one switch (using red, black and green colour wires as colour coding) complete with 1.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (Min 50mm deep and 1.6mm thick sheet, suitable size) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches/ socket / regulator etc, including provn of 1.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) including fixing of switch/socket/regulator etc complete all as specified and as directed. (switch, socket, regulator shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ).
-do- all as per srl No. 3 above but with 2.5 sqmm (nominal cross section area) for one three pin switch socket outlet 5 Amps on the independant borad
-do- all as per srl No. 3 above but one three pin switch socket outlet 5 Amps on the same borad Note;- Copper wire from MCB DB to switch board shall be 2.5 sqmm for phase, neutral and earth drawn through and including PVC conduit 25 mm dia (medium duty, ISI marked) with all fittings and all accessories.
-do- all as per srl No. 3 above but one call bell controlled by one bell switch
-do- all as per srl No. 3 above but wiring with 2.5 sqmm multistranded cable and earth wire with copper conductor of size 2,5 sqmm for 15 Amps
Material and labour for concealed Point wiring for one socket outlet 15/20 Amps point controlled by one switch (on independant board) (using red, black and green colour wires as colour coding) complete with 4 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 25mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (Min 50mm deep and 1.6mm thick sheet, suitable size ) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches / socket, including provn of 4 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3), including fixing of switch, socket complete all as specified and as directed. (switch, socket shall be measured and paid separately under appropriate item of BOQ as supply only but cost of moudlar cover plate with frame and labour for fixing the same shall deemed to be included in the unit rate).
Supply only modular switch 6Amps, piano flush type, single pole, one way (1 module) complete all as specified and as directed by Engineer-in-charge (laminated sheet top cover is included in point wiring).
Supply only modular switch 16Amps, piano flush type, single pole, one way (1 module) complete all as specified and as directed by Engineer-in-charge (laminated sheet top cover is included in point wiring).
Supply only modular socket outlet 2 in 1, 6Amps, flush type fixed on laminated sheet top cover complete all as specified and as directed by Engineer-in-charge (laminated sheet top cover is included in point wiring).
Supply only modular socket outlet 5 in 1, 16Amps, flush type fixed on laminated sheet top cover complete all as specified and as directed by Engineer-in-charge (laminated sheet top cover is included in point wiring).
Supply and fixing Ceiling Rose, polycarbonate, isolated body, surface bakelite 2 to 3 terminal, 240 volts, 5/6 Amp, ISI Marked complete all as specified and as directed by Engineer-in-charge.
Supply and fixing electric calling Bell Ding Dong type, AC 230 Volts single pole including making elctric connection complete all as specified and as directed by Engr-in-charge.
Supply only modular Bell Push switch, piano flush type, 6Amps, single pole, one way (1 module) fixed on laminated sheet top cover (laminated sheet top cover is included in point wiring) complete all as specified and as directed by Engineer-in-charge.
Supply and hanging /fixing ceiling fan 1200 mm sweep AC Supply (Input Voltage Range ; 120 to 280V), BLDC type, 5 star rated, BEE and ISI Marked super enamelled, copper winding of 'B' class insulation, single phase, maximum 30W (± 10%), Temperature rise 40 degree maximum without remote with and including capacitive regulator, 03 No blades, down rod including accessories, white colour, total harmonic less than 10%, 5 speed, hanging in position including making connection with flexible cord three core twisted copper conductor of suitable size from ceiling rose to fan complete all as specified and as directed by Engr-in-charge. Note :- (i) Serial Number as issued by Engr-In-Charge of celing fan and GE Office name shall also be written on fan with red colour permanent marker and fixing of regulator on switch board, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account
Supply and fixing exhaust fan (heavy duty) steel body, AC single Phase 230V, 50Hz, 900RPM, size 300mm sweep with blades and frame including new mosquito stainless steel wire mesh of guage 0.36mm with suitable wooden frame protection against birds etc mounted in suitable opening arrangement in wall and electric connection with and including three core PVC Insulated PVC Sheathed copper conductor flexible cable 24/0.2mm drawn in flexible PVC conduit and hanging on wall with 4 Nos steel fastners 12mm dia 200mm long and making good the disturbed surface complete all as specified and as directed by Engineer-in-charge. Note :- (i) Serial Number as issued by Engr-In-Charge of fan and GE Office name shall also be written on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account (ii) Cost for making suitable cutting/opening in wall for fixing of exhaust fan including making good disturbed surface and masonary work shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account.
Supply and fixing exhaust fan (heavy duty) steel body, AC single Phase 230V, 50Hz, 900RPM, size 450mm sweep with blades and frame including new mosquito stainless steel wire mesh of guage 0.36mm with suitable wooden frame protection against birds etc mounted in suitable opening arrangement in wall and electric connection with and including three core PVC Insulated PVC Sheathed copper conductor flexible cable 24/0.2mm drawn in flexible PVC conduit and hanging on wall with 4 Nos steel fastners 12mm dia 200mm long and making good the disturbed surface complete all as specified and as directed by Engineer-in-charge. Note :- (i) Serial Number as issued by Engr-In-Charge of fan and GE Office name shall also be written on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account (ii) Cost for making suitable cutting/opening in wall for fixing of exhaust fan including making good disturbed surface and masonary work shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account.
Supply and fixed for SPN 8 way, 240 volt distribution board double door made out of CRCA mild steel sheet surface with insulated material like polyester or with powder coating surface mounting with Bus bar rating 200 Amps, dust and vermin proof, IP-43 protected, suitable for incorporation of MCB's and isolators etc complete all as specified and as directed by Engineer-in-charge.
Supply and fixed for SPN 12 way, 240 volt distribution board double door made out of CRCA mild steel sheet surface with insulated material like polyester or with powder coating surface mounting with Bus bar rating 200 Amps, dust and vermin proof, IP-43 protected, suitable for incorporation of MCB's and isolators etc complete all as specified and as directed by Engineer-in-charge.
Supply and fixed for TPN 4 way, 415 volt distribution board double door made out of CRCA mild steel sheet surface with insulated material like polyester or with powder coating surface mounting with Bus bar rating 200 Amps, dust and vermin proof, IP-43 protected, suitable for incorporation of MCB's and isolators etc complete all as specified and as directed by Engineer-in-charge.
Supply and fixed for distribution board double door 4 way SPN made out of CRCA mild steel sheet surface with insulated material like polyester or with powder coating surface mounting suitable for incorporation of MCB's and isolators etc complete all as specified and as directed by Engineer-in-charge.
Supply and fixing single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amps, 240 volts, AC supply complete all as specified and directed by Engineer-in-Charge.
Supply and fixed for TPN distribution board 4 way double door made out of CRCA mild steel sheet surface with insulated material like polyester or with powder coating flush/surface mounting with copper Bus bar suitable rating with neutral bar and earth bar and cable tie for cable management, IP-54 protection and provision and including MCCB 4 pole 160 Amp, 16 KA as incomer and MCBs as outgoing, dust and vermin proof complete all as specified and as directed by Engineer-in-charge.
Supply and fixed of MCB suitable for 415 volts AC Supply, TPN with over load and short circuit protection and rupturing capacity not less than 10 KA, C Curve as 40 to 63 Amps complete all as specified and as directed by Engineer-in-charge.
Supply and fixed of MCB suitable for 415 volts AC Supply, 3 pole with over load and short circuit protection and rupturing capacity not less than 10 KA, C Curve as 40 to 63 Amps complete all as specified and as directed by Engineer-in-charge.
Supply and fixed of MCB suitable for 415 volts AC Supply, 3 pole with over load and short circuit protection and rupturing capacity not less than 10 KA, C Curve as 6 to 32 Amps complete all as specified and as directed by Engineer-in-charge.
Supply and fixed of MCB suitable for 240 volts AC Supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA, C Curve as 6 to 32 Amps complete all as specified and as directed by Engineer-in-charge.
Supply and fixed of MCB suitable for 240 volts AC Supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA, C Curve as 40 to 63 Amps complete all as specified and as directed by Engineer-in-charge.
Supply and fixed of MCB suitable for 240 volts AC Supply, SP 6 to 32 Amp with over load and short circuit protection and rupturing capacity not less than 10 KA, C Curve complete all as specified and as directed by Engineer-in-charge.
Supply and fixing blanking plate of plastic suitable for any type of DB complete all as specified and as directed by Engineer-in-charge.
Material and labour for submain wiring comprising single core, 2 Runs of 4.0 sqmm nominal cross sectional area multi stranded FRLS copper conductor cable, PVC insulated unsheathed 1100 volts grade drawing in and including PVC conduit of size min 20mm dia ISI marked and its fittings concealed in floor/roof / wall complete including provision of 01x4.0 sqmm nominal cross sectional area multi stranded FRLS copper conductor cable, PVC insulated unsheathed 1100 volts grade as earth wire and using color code as per IS complete all as specified and as directed by Engineer-in-Charge. Note : Meter of pipe including fitting and 3 runs of single core cable shall be measured as unit Runing meter. Additional wire/cable required for connecting to MCB shall be included in overall cost quoted.
Material and labour for submain wiring comprising single core, 2 Runs of 6.0 sqmm nominal cross sectional area multi stranded FRLS copper conductor cable, PVC insulated unsheathed 1100 volts grade drawing in and including PVC conduit of size min 25mm dia ISI marked and its fittings concealed in floor/roof / wall complete including provision of 01x6.0 sqmm nominal cross sectional area multi stranded FRLS copper conductor cable, PVC insulated unsheathed 1100 volts grade as earth wire and using color code as per IS complete all as specified and as directed by Engineer-in-Charge. Note : Meter of pipe including fitting and 3 runs of single core cable shall be measured as unit Runing meter. Additional wire/cable required for connecting to MCB shall be included in overall cost quoted.
Material and labour for submain wiring comprising single core, 4 Runs of 6.0 sqmm nominal cross sectional area multi stranded FRLS copper conductor cable, PVC insulated unsheathed 1100 volts grade drawing in and including PVC conduit of size min 25mm dia ISI marked and its fittings concealed in floor/roof / wall complete including provision of 02x6.0 sqmm nominal cross sectional area multi stranded FRLS copper conductor cable, PVC insulated unsheathed 1100 volts grade as earth wire and using color code as per IS complete all as specified and as directed by Engineer-in-Charge. Note : Meter of pipe including fitting and 6 runs of single core cable shall be measured as unit Runing meter. Additional wire/cable required for connecting to MCB shall be included in overall cost quoted.
Material and labour for submain wiring comprising single core, 4 Runs of 10.0 sqmm nominal cross sectional area multi stranded FRLS copper conductor cable, PVC insulated unsheathed 1100 volts grade drawing in and including PVC conduit of size min 32mm dia ISI marked and its fittings concealed in floor/roof / wall complete including provision of 02x10.0 sqmm nominal cross sectional area multi stranded FRLS copper conductor cable, PVC insulated unsheathed 1100 volts grade as earth wire and using color code as per IS complete all as specified and as directed by Engineer-in-Charge. Note : Meter of pipe including fitting and 6 runs of single core cable shall be measured as unit Runing meter. Additional wire/cable required for connecting to MCB shall be included in overall cost quoted.
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI earthing wire of size 4 mm dia by means of GI bolts/nuts/washers and protected by 15 mm bore GI light grade pipe upto test point or upto main switch board, HT/LT equipments, fixing with 02 Nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common salt all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50m, Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and as directed by Engineer-in-charge. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing wire upto test point or upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.
Supply and fixing LED tube light fitting polycarbonate housing 1 x 18/20 Watt, appx 4 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable of size 01 sqmm from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts. (c) Temp operating range : Minus 10°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5% (f) IP rating : IP-20. (g) Aluminium housing & Integrated Electronic driver (h) LED Driver of the same make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection minimum 2.5 kV. (l) CCT : Minimum 6500K (m) CRI : more than 80 (n) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
Supply and fixing LED tube light fitting polycarbonate housing 1 x 10 Watt, appx 2 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable of size 01 sqmm from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts. (c) Temp operating range : Minus 10°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5% (f) IP rating : IP-20. (g) LED Driver of the same make as of the luminaire. (h) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (j) Surge protection minimum 2.5 kV. (k) CCT : Minimum 6500K (l) CRI : more than 80 (m) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
Supply and fixing LED lamp 1x9 watt including PVC holder with complete suitable for fixation on wall/roof with body robust corrosion resistant, superior flnish and without any cracks of through holes complete all as specified and directed by Engineer-in-Charge
Supply and fixing lamp holder PVC/polycarbonate type with back plate suitable for batten fitting including one LED lamp 1x 0.5 watt red/green colour complete all as specified and directed by Engineer-in-Charge
Supply and fixing energy efficient LED security light fitting of 35W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street/roadway luminaire, with driver, including electric connection with using 3 core flexible copper conductor cable 1.5Sqmm from ceiling rose to light fitting, fixing the light fitting with new bracket made out of GI tubing medium grade 32mm dia, 1.2 metre long bent to shape at 32 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron size 25x3 mm with suitable nuts and bolts for fixing of bracket including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP66. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI : More than 80 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
Supply and fixing rechargeable emergency inverter type with backup of 03 hrs, LED batten light fitting 20 watts, compact type, LED cool light, 6500 K, 2000lm with operating voltage 220 V - 240 V, energy efficient, AC, minimum 03 feet long with decorative box linear, including 02 core flexible copper cable from ceiling rose to tubelight complete all as specified and as directed by Engineer-in-charge.
Supply and fixing surface/recessed mounted LED panel, slim type premium diffuser to ensure glare free even light distribution 34 watt, 6500 K, input voltage range 140 to 270 V, temperature operating range upto 45 degree celsius, PF 0.95 of minimum 2x 2 ft with all mounting accesoories, PVC/polycarbonate body with all diffuser, driver, surge protection as per standard manufacturer complete all as specified and as directed by Engineer-in-charge.
Rigid non metallic PVC Conduit 20mm dia (external) for sub main/telephone wiring inclusive of all fittings such as tees, bends, elbow, reducers, junction boxes bell mouth tube ends and all fixing accessories such as couples, bolts, nuts, saddles, pipe hooks etc complete all as specified and as directed by Engineer-in-charge.
Rigid non metallic PVC Conduit 25mm dia (external) for sub main/telephone wiring inclusive of all fittings such as tees, bends, elbow, reducers, junction boxes bell mouth tube ends and all fixing accessories such as couples, bolts, nuts, saddles, pipe hooks etc complete all as specified and as directed by Engineer-in-charge.
Material and labour for Mild steel box flush mounted of size 100mm x100mmx50mm having holes for 20 mm conduit entry including 03 pin telephone socket outlet flush type marked with symbol of telephone and 03 mm thick plastic laminated sheeet cover and making good disturbed surfaces of walls by using CM (1:3) complete all as specified and as directed by Engineer-in-Charge
Material and labour for Mild steel box flush mounted of size 100mm x100mmx100mm having holes for 20 mm conduit entry including 02 pin TV socket outlet flush type marked with symbol of TV and 03 mm thick plastic laminated sheeet cover and making good disturbed surfaces of walls by using CM (1:3) complete all as specified and as directed by Engineer-in-Charge
Supply and fixing High bay beam LED light fitting of 150 Watt, specifically designed heat sink for long life vertical high bay/medium LED luminaries complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die cast aluminium alloy including fixing on wall/roof with help of suitable GI clamps, nut bolts/fastners, pendant of suitable length and washers etc, the luminaries shall be monolithic construction totaly enclosed dust and water proof with minimum IP 65 protection as per IS-10322 (1982, Part-I) with latest amendments and input voltage range 140-300V, AC frequency 50-60Hz, PF should be more than 0.9 with total Harmonic distoration THD (I) less than 15%, cool white colour and lamp starting time should not be more than 10 second, Fitting should be provided with 10KV Surge protection, Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 300V, AC, Driver should also have double phase protection, no load, open circuit and short circuit protection. LED light fitting should be suitable for ambient temperature from minus 10 degree centigrade to 50 degree centigrade and humidity level 10% to 90% RH. LED Driver of the make as of the luminaire. Covers should be polycarbonate/toughened glass to ensure IP 65 degree protection, cover should not degrade due to heating and ageing. The efficiency of LED luminaries system shall be more than 100 lumens per watt and must be certified by the LM-79 test report.complete all as specified and as directed by Engineer-in-Charge
Supply and fixing CMRI certified flameproof 1x16 Watt LED tube light fitting, well glass luminaire suitable for RF LED lamp, recommended for Gas/Vapour group of IIA & IIB and zone 1 & 2, IP65 protection, Epoxy finish LM6 die cast aluminium housing with heat resistant toughened glass, including inbuilt electronic driver, 2 kv surge protection, internally pre-wired, LED lamp, connector block etc complete with all other accessories including making electric connection connecting with twin core twisted flecible copper conductor cable and connector block, tobe fixed flush to wall/ceiling surface complete all as specified and as directed by Engineer-in-Charge. Specification for LED luminaire (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP65. (g) CRI : More than 80 (h) CCT : 6500 K. (i) LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended)
Supply and fixing switch flame proof / water proof distribution box SPN 04 way in ML-5 construction with cable entires from bottom, cable termination box all as per cat no CS/174CMRI certified of make sudhir switchgears or equivalent in approved makes complete all as specified and as directed by Engineer-in-Charge.
Material and labour for concealed Flame proof Point wiring for light/fan points (using red, black and green colour wires as colour coding for single phase circuits) complete with 1.5 Sqmm (nominal cross section area) FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) for main point and for continues as earth wire connected to earth dolly etc. (Phase, netural and earth wire) drawn through and including ERW rigid conduit stove enamelled conduit with all flame proof fittings and all flame proof accessories (duly tested by CMRI) i.e. pipe bend, union socket, reducer, elbow, pipe hook, connectors, junction box, insepction elbow, GI sunken terminal box with 3mm thick bakelite laminated hylem sheet top cover etc, including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. Note :- (i) Swicth, MCB and DB shall be measured and paid separately under appropriate item of BOQ).
Supply and fixing flame proof / water proof switch/isolator 10A single pole ON/OFF complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing CMRI certified flameproof exhaust fan of size 305mm, single phase, with 1440 RPM , 0.25 HP, 1120 CFM, complete with all other accessories including making electric connection connecting with three core twisted flecible copper conductor cable and connector block, complete all as specified and as directed by Engineer-in-Charge. Note :- (i) Serial Number as issued by Engr-In-Charge of fan and GE Office name shall also be written on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account
Supply and fixing LED post top lantern 25 watt 240 V 50 Hz in die cast aluminium bottom housing and spun aluminium top reflector with decorative clear acrylic diffuser IP 65 protection complete all as specified and as directed by Engineer-in-Charge.
Subtotal
Lump sum price worked out by the tenderer for “INTERNAL WATER SUPPLY WORKS" as listed in Schedule ‘A’ Section - III (Part-I)
Sch 'A' Sec - III (Part-II), INTERNAL WATER SUPPLY WORKS
Supply and fixing two way Bib cock/Angle stop valve with flange, cast copper alloy chromium plated, screwed down high pressure with on/off handle screwed ends suitable for 15 mm bore pipe iron pipe or for brass ferrule/unions and fixed complete all as specified and as directed. Make: Jaguar(continental series)/Hindware (contessa plus series)/ Cera (Ocean series) or any technocommercial make approved by GE
Supply and fixing chlorinated polyvinyl chloride (CPVC) pipe heavy duty outer dia 16 mm having thermal stability for hot and cold water supply including all new CPVC fittings plain & brass threaded like elbow, tee, union, socket, reducer etc. including CPVC solvent cement for jointing and fixed complete to walls, ceiling or laid in floor including complete all as specified and as directed by Engineer-in- charge. Note :- Cutting chases if required same shall be measured and paid separately under appropriate item of BOQ.
Supply and fixing chlorinated polyvinyl chloride (CPVC) pipe heavy duty outer dia 20 mm having thermal stability for hot and cold water supply including all new CPVC fittings plain & brass threaded like elbow, tee, union, socket, reducer etc. including CPVC solvent cement for jointing and fixed complete to walls, ceiling or laid in floor including complete all as specified and as directed by Engineer-in- charge. Note :- Cutting chases if required same shall be measured and paid separately under appropriate item of BOQ.
Supply and fixing chlorinated polyvinyl chloride (CPVC) pipe heavy duty outer dia 25 mm having thermal stability for hot and cold water supply including all new CPVC fittings plain & brass threaded like elbow, tee, union, socket, reducer etc. including CPVC solvent cement for jointing and fixed complete to walls, ceiling or laid in floor including complete all as specified and as directed by Engineer-in- charge. Note :- Cutting chases if required same shall be measured and paid separately under appropriate item of BOQ. Note for CPVC pipes : pipes inside the building shall be fixed concealed and outside the buildings shall be fixed on the surface with wall hooks as directed by Engr-in-charge.
Supply and fixing chlorinated polyvinyl chloride (CPVC) pipe heavy duty outer dia 40 mm having thermal stability for hot and cold water supply including all new CPVC fittings plain & brass threaded like elbow, tee, union, socket, reducer etc. including CPVC solvent cement for jointing and fixed complete to walls, ceiling or laid in floor including complete all as specified and as directed by Engineer-in- charge. Note :- Cutting chases if required same shall be measured and paid separately under appropriate item of BOQ. Note for CPVC pipes : pipes inside the building shall be fixed concealed and outside the buildings shall be fixed on the surface with wall hooks as directed by Engr-in-charge.
Supply and fixing single lever concealed diverter incl bath spout & Shower complete all as specified and as directed by Engineer-in-charge.
Supply and fixing for 25mm bore CPVC long handle vavle complete all as specified and as directed by Engineer-in-charge.
Supply and fixing for 40mm bore CPVC long handle vavle complete all as specified and as directed by Engineer-in-charge.
Supply and fixing for 15mm bore central hole basin mixer chromium plated for wash hand basin complete all as specified and as directed by Engineer-in-charge.
Supply and fixing health faucet fancy type, CP including 1.25 meter long 8mm dia flexible tube and including wall hook and fixing material complete all as specified and as directed by Engineer-in-charge.
Subtotal
Lump sum price worked out by the tenderer for “ROAD, PCC TILES AND HUME PIPE CULVERT WORKS) " as listed in Schedule ‘A’ Section -IV (Part-I)
Sch 'A' Sec - IV (Part-II), ROAD, PCC TILES AND HUME PIPE CULVERT WORKS
Material and labour for premix bituminous concrete 40mm consolidated thickness with min 5.4 % binder content (bitumen of grade VG-30) by weight of total mix using sensor paver electronic sensing device for automatic leveling and profile control withi the specified tolerance and internal heating arrangement for the screed all as specified in Table 500-17 of MoRTH specification for road and bridge works 2013, rolled and compacted to required camber and gradient with tandem vibratory roller 8 to 12 tonne power roller to a uniform smooth surface complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Thermo plastic paint road marking 2mm thick painting (lines, dashes, arrows, letters etc) with road safety spikeries glass beads @ 8% by weight including preparation of new or previously treated road surfaces and applying paint by using special applicator machine with heating arrangement complete all as specified and as directed by Engineer-in-Charge
Supply and laying/fixing 80mm thick M-40 grade, factory made precast interlocking tile/paving block (made by using PVC/Rubber moulds on vibrating table machine) using grey cement and no pigment, any shape hexagon/ triangular/ zigzag/ I-shaped etc as directed, confirming to relavent IS, laid over and including 25 mm thick layer of sand cushioning and filling the interstices etc with sand , finishing and sweeping extra sand; complete all as specified and as directed by Engineer-in-Charge Note:- Paverblock/tile shall be approved by GE before incorporation in the work.
Supply and laying/fixing 60mm thick M-35 grade, factory made precast interlocking tile/paving block (made by using PVC/Rubber moulds on vibrating table machine) using grey cement and no pigment, any shape hexagon/ triangular/ zigzag/ I-shaped etc as directed, confirming to relavent IS, laid over and including 25 mm thick layer of sand cushioning and filling the interstices etc with sand , finishing and sweeping extra sand; complete all as specified and as directed by Engineer-in-Charge Note:- Paverblock/tile shall be approved by GE before incorporation in the work.
Material and labour for sand cushioning, with dry and clean tibba sand (for under ground cable) 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified and as directed. Note:- (i) Punned thickness shall be considered for payment purpose (ii) Approved sand free from vegetations, grass and other deleterious substances shall be used.
Subtotal
Lump sum price worked out by the tenderer for “(AREA DRAINAGE WORKS)" as listed in Schedule ‘A’ Section -V (Part-I)
Sch 'A' Sec - V (Part-II), AREA DRAINAGE WORKS
Supply and fixing factory made precast cover slab made of steel fibre reinforced concrete (SFRC), medium duty, 100 kN breaking load, in any shape and size (square /rectangular/ circular), 75 mm thickness, minimum M 30 grade of concrete, conforming to IS 12592: 2002 complete all as specified and as directed by Engineer-in-Charge.
Subtotal
Lump sum price worked out by the tenderer for “SEWAGE DISPOSAL WORKS" as listed in Schedule ‘A’ Section - VI (Part-I)
Sch 'A' Sec - VI (Part-II), SEWAGE DISPOSAL WORKS
Supply and laying DWCPE (SN8) drain pipes 180 (OD)/163(ID) mm dia pipe as per IS-16098 (Part-II), laid in trenches on and including bed 100mm thick beding comprising of well compacted clean poorly graded gravel, gravel/sand mixture with little or no fines to required slope, including all accessories/fittings/jointing ring, jointing and testing complete all as specified and as directed by Engineer-in-Charge. Note : Excavation, earth work and pedestal /anchorage if required shall be measured & paid separately under respective item of Sch
Supply and laying DWCPE (SN8) drain pipes 200 (OD)/175(ID) mm dia pipe as per IS-16098 (Part-II), laid in trenches on and including bed 100mm thick beding comprising of well compacted clean poorly graded gravel, gravel/sand mixture with little or no fines to required slope, including all accessories/fittings/jointing ring, jointing and testing complete all as specified and as directed by Engineer-in-Charge. Note : Excavation, earth work and pedestal /anchorage if required shall be measured & paid separately under respective item of Sch.
Supply and laying DWCPE (SN8) drain pipes 300 (OD)/260 (ID) mm dia pipe as per IS-16098 (Part-II), laid in trenches on and including bed 100mm thick beding comprising of well compacted clean poorly graded gravel, gravel/sand mixture with little or no fines to required slope, including all accessories/fittings/jointing ring, jointing and testing complete all as specified and as directed by Engineer-in-Charge. Note : Excavation, earth work and pedestal /anchorage if required shall be measured & paid separately under respective item of Sch.
Supply, Installing, testing and commissioning of Non clog vertical submersible pump for handling sewage water and having discharge of minimum 380 LPM and 16 mtr head, 415 v, 50 Hz, 2900 RPM, “F” CI Insulation, IP 68 protection, 40 degree centigrade operating temperature with CI impellor, CI motor body, CI pump housing, stainless steel shaft and delivery pipe size of 50mm dia including hoisting submersible sewage pump into sewage collection tank using suitable SS heavy duty (Gde 316) chain and anchoring with hook on top of sewage tank with necessary nuts, bolts, washers etc complete all as specified and directed.
Supply and fixing PVC insulated overall sheathed 3 core submersible flat copper cable 1100 volts grade 2.5 sqmm including PVC conduit of suitable size with accessories all as specified and directed.
Supply and laying, jointing, commissoning and testing Ductile iron pipe 80mm with spigot and socket end centrifugally cast (spun) class K-9 conforming to IS-8329-2000 in any length laid in trenches complete all as specified and directed.
Supply of Ductile iron pipe fittings i.e tee, bend, socket, collar etc with spigot and socket end centrifugally cast (spun) including rubber gasket, class conforming to IS-8329-2000 suitable sizes of 80mm dia to 200mm dia all as specified and directed.
Supply and fixing 50 mm bore cast iron body non return valve (NRV), confirming to IS 5312 (ISI marked), both flanged ends in swing type and drilled, including jointing material such as nuts, bolts, washers and rubber sheet insertion at both ends etc complete all as specified and as directed.
Supply and fixing cast iron sluice valve 50mm dia with flanged ends class PN 1.0 (heavy duty ISI marked) confirming to IS: 14846-2000, drilled type, complete with stainless steel spindle, CI gate with brass ring, iron wheel handle, complete including jointing material such as nuts, bolts, washers and rubber sheet insertion 3.0mm thick at both ends etc complete all as specified and as directed by Engineer-in-Charge.
Supplying, installing, commissioning and testing complete of manufacturer or OEM (Original Eqpt Manufacturer) manufactured and tested static Diesel Engine driven Generating Set, radiator cooled, with AMF panel capable of delivering 7.5 KVA or nearest higher rating 415 volts AC 3 phase, 4 wire system of supply, 50Hz. The DG set shall consist of diesel engine coupled through flexible coupling to matching alternator and mounted on foundation pads on common base frame in the CPCB approved acoustic enclosure (the complete set confirming to and test certificate as per CPCB-IV norms and as specified) with AMF control panel standardised by manufacturer, inbuilt fuel tank, flexible exhaust pipe, incl necessary PCC foundation as per manufacturer instructions complete all as specified and as directed and comprising with the following:--
Engine (Prime mover) : Diesel Engine 1500 RPM of suitable BHP as recommended by manufacturer (at rated RPM), water cooled, Single cylinder, inline, 4 stroke, confirming to ISO 3046 / BS 5514 with turbo charged air cooled , 1x88 AH 12 Volts batteries start, mechanical FIP, Electronic Governor, pulse tuned exhaust manifold, stainless steel exhaust flexible connection complete with flywheel and all standard fittings/fixture as per manufacturing practice including suitable engine control panel with tachometer, lub oil temp and pressure gauge, water temp guage, starter, dynamo, fuel tank, fuel and lube oil filter, Dry type replaceable paper element air cleaner etc.
Alternator : AC alternator, self-excited, self-regulated, self-ventilated, brushless design, confirming to BS 2613/5000, 3 phase, 415 volts, 4 wire rated line current min 56 Amps output at PF 0.8, 1500 RPM, insulation class ‘H’ enclosure IP 23 complete with AVR with ± 1% voltage regulation, directly coupled to and matched with engine.
Anti-vibration pad for mounting engine alternator assembly on the base frame/plate.
Base frame/plate made out of structural steel as per manufacturer’s recommended design/specifications.
Acoustic Enclosure : Engine Alternator assembly mounted on AV mounts with silencer and SS exhaust bellow suitable optimised to meet stringent noise emission standards as laid down by MOEF/CPCB. Base rail with draw out type fuel tank provided with drain plug, air vent, inlet and out let connection, level indicator, manhole etc.
01 No 12 volt x 88 AH maintenance free batteries complete with suitable size copper lead.
AMF control panel : RAL 9003 white powder coated control panel made out of CRCA sheet provided with AMF system (automatic starting of main failure) and Start Stop push button for manual operating, provide with MCCB of suitable rating with short circuit protection, controller which display voltage, current, KW, PF, Frequency, KWH, lube oil pressure, indicating lamps for ‘load ON’ and ‘set running’ current transformer of suitable rating etc, aluminium bus bar of suitable rating with incoming and outgoing termination complete all as per manufacturer’s recommended design/specifications.
The contractor shall supply following maintemance spare part and tool kit for the generator set :- (i) Fuel filter - 02 Nos (ii) Lube oil filter - 01 No (iii) Air filter - 01 No (iv) V-belt - 02 Sets (v) Tool kit socket set - 01 No (vi) DE Spanner set - 01 No (vii) Ring Spanner set - 01 No (viii) Clamp meter - 01 No
Note :- (i) Any item left out for successful operation of AMF panel is deemed to be included in overall cost quoted. (ii) DG set should be sound proof as per latest policy (iii) Cost of maintenance free batteries as per recommendations of manufacture shall deemed included in unit rate quoted by contractor (iv) Cost of PCC foundation as per recommendations of manufacturer shall deemed included in unit rate quoted by contractor. (v) Initial filling of lubricating oil/coolant and fuel required for testing of DG set shall be provided by the contractor without any extra cost. (vi) Exhaust from DG set shall be as per latest CPCB [II] norms. Alternatively emission control device within overall cost quoted shall be provided (vii) Pre commissioning test shall be carried out by rep of Accepting Officer. All necessary equipment’s, consumables and T&P required for successful completion of the test shall be arranged by the contractor and cost for the same shall deemed included in unit rate quoted by contractor. (viii) Contractor shall produce test certificate of DG set, no payment shall be allowed without test certificate.
Supply, installations, testing and commissioning of factory made LT panel board of suitable size, outdooor type (double door both side openable including locking arrangements) 415 volts, dust proof, vermin proof, made out of CRCA outer sheet 3.15mm thick powder coated and fully compartmentalized inside panel with 2mm thick CRCA sheet powder coated to accommodate the incoming and outgoing. Each switch gear shall have independent opening and having provision for front and rear side opening, double door with hinges including provision of rubber beeding and brass cable glands for each cable to make it weather and vermin proof. Provision of air fins for ventilation complete with seperate bus bar chamber. Panel shall be mounted on angle iron frame and 04 Nos legs made up of 40x40x5mm, Legs shall be 750mm long, 300mm grouted in blocks of PCC (1:2:4) type B-1 (using 20mm graded stone aggregates) with 450mm ground clearance, frames and legs duly spray painted with seven tank process internally and externally with two coats of synthetic enamel over a coat of red oxide primer. Internal wiring of panel board with soild conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/ pasted to the panel board, door complete including all connection incoming/outgoing all as directed by Engr-in- charge and comprising of following accessories.
INCOMING:
(a) MCCB TP 40Amps, 'C' Curve, 10 KA - 01 No. (For incoming)
(b) Copper Busbar 50 Amp capacity, 4 strip mounted on porcelain insulators.
(b) blank
(c) Multi Functiona; Digital Voltmeter and Ampere meter incl CT Coils 32/5A.
(d) LED indicating lamp got R,Yand B Phases - 01 Set (Set of Three)
OUTGOING:
(e) MCB TP 20 Amp C curve, 10 KA capacity - 02 No (For two DOL Starters)
(f) Power contactor, 9A- 02 Nos (For two of DOL Starters)
(g) Overload Thermal relay (4-6A) -02 Nos (For two of DOL Starters)
(h) Indicator LED for ON and OFF Indication -02 Nos (For two of DOL Starters)
(j) Push button START & STOP - 02 Nos (For two of DOL Starters)
(k) Rotary switch 3 phase - 01 No (For two of DOL Starters)
(l) Ultra sonic Non-contact type water level sensor ( for sewerage water) with PLC -01 No
(m) Single phase Preventor for suitable rating -02 Nos
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI earthing strip 32x6mm by means of GI bolts/nuts/washers and protected by 40 mm bore GI light grade pipe upto test point or upto main switch board / electric equipment / pole / lightning arrestor / HT/LT equipments / GODO switch etc, fixing with 02 Nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common salt all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50m, Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and as directed by Engineer-in-charge. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing strip upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.
Supply and fixing steel water tubing 50 mm bore heavy grade, galvanised, ISI marked including all fittings with screwed and socketed joints, fixing for suction/delivery for pump complete all as specified and as directed by Engineer-in-charge.
Subtotal
Lump sum price worked out by the tenderer for “SECURITY FENCING, COMPOUND WALL AND GATE WORKS" as listed in Schedule ‘A’ Section - VII (Part-I)
Sch 'A' Sec - VII (Part-II), “SECURITY FENCING, COMPOUND WALL AND GATE WORKS"
Material and labour for precast Dholpur stone jalli, 750 mm x 600 mm and 25 mm thick (measured solid) including all mouldings including frame complete all as specified and as directed by Engineer-in-Charge.
Material and labour for precast Dholpur stone raining pillar of size , 50 mm x 50 mm x 600 mm (measured solid) including all mouldings including frame complete all as specified and as directed by Engineer-in-Charge.
Material and labour for providing and fixing stainless steel (grade 310) railing made of hollow tubes, channels, plates etc including welding, grinding, buffing, polishing, and making curvature (wherever required) and fiting the same with necessary SS nuts and bolts, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc of required size on the top of floor or the side of waist slab with suitable arrangement complete all as specified and as directed by Engineer-in-Charge.
Subtotal
Lump sum price worked out by the tenderer for “EXTERNAL WATER SUPPLY WORKS AND MECHANICAL LAUNDARY" as listed in Schedule ‘A’ Section-VIII (Part-I)
Sch 'A' Sec - VIII (Part-II), EXTERNAL WATER SUPPLY WORKS AND MECHANICAL LAUNDARY
Supplying, laying, jointing and testing Ductile iron pipe (ISI marked) class K-9, bore 300mm, confirming to IS : 8329-2K, spigot & socketed ends centrifugally cast, with cement mortar lining inside and metallic zinc coating with finishing layer of bituminous paint on outside the pipe, including rubber tyton joints (Push-on joint) complete all as specified and as directed by Engineer-in-Charge. Note : (i) Earth work, DI specials/ fittings shall be measured and paid separetly however cost of joining is included in overall cost quoted by the contractor. (ii) Test Certificate for pipes from manufacturer shall be produced. No payment shall be entertained without Test Certificate.
Supplying, laying, jointing and testing Ductile iron pipe (ISI marked) class K-9, bore 150mm, confirming to IS : 8329-2K, spigot & socketed ends centrifugally cast, with cement mortar lining inside and metallic zinc coating with finishing layer of bituminous paint on outside the pipe, including rubber tyton joints (Push-on joint) complete all as specified and as directed by Engineer-in-Charge. Note : (i) Earth work, DI specials/ fittings shall be measured and paid separetly however cost of joining is included in overall cost quoted by the contractor. (ii) Test Certificate for pipes from manufacturer shall be produced. No payment shall be entertained without Test Certificate.
Supplying, laying, jointing and testing Ductile iron pipe (ISI marked) class K-7, bore 200mm, confirming to IS : 8329-2K, spigot & socketed ends centrifugally cast, with cement mortar lining inside and metallic zinc coating with finishing layer of bituminous paint on outside the pipe, suitable for and including rubber tyton joints (Push-on joint) complete all as specified and as directed by Engineer-in-Charge. Note : (i)Earth work, DI specials/ fittings shall be measured and paid separetly however cost of joining is included in overall cost quoted by the contractor. (ii) Test Certificate for pipes from manufacturer shall be produced. No payment shall be entertained without Test Certificate.
Supplying, laying, jointing and testing Ductile iron pipe (ISI marked) class K-7, bore 150mm, confirming to IS : 8329-2K, spigot & socketed ends centrifugally cast, with cement mortar lining inside and metallic zinc coating with finishing layer of bituminous paint on outside the pipe, suitable for and including rubber tyton joints (Push-on joint) complete all as specified and as directed by Engineer-in-Charge. Note : (i)Earth work, DI specials/ fittings shall be measured and paid separetly however cost of joining is included in overall cost quoted by the contractor. (ii) Test Certificate for pipes from manufacturer shall be produced. No payment shall be entertained without Test Certificate.
Supplying, laying, jointing and testing Ductile iron pipe (ISI marked) class K-7, bore 100mm, confirming to IS : 8329-2K, spigot & socketed ends centrifugally cast, with cement mortar lining inside and metallic zinc coating with finishing layer of bituminous paint on outside the pipe, suitable for and including rubber tyton joints (Push-on joint) complete all as specified and as directed by Engineer-in-Charge. Note : (i)Earth work, DI specials/ fittings shall be measured and paid separetly however cost of joining is included in overall cost quoted by the contractor. (ii) Test Certificate for pipes from manufacturer shall be produced. No payment shall be entertained without Test Certificate.
Supply and fixing DI fitting upto 200 mm bore pipe line, confirming to IS : 9523-2K, for reducing/bends (any type radius and angle) tapers any type, straight, bend, increasing decreasing or double socket extra Tee pieces single branch Y 'Junction' double branch cross collers cap etc complete all as specified and as directed by Engineer-in-Charge. Note:- Make of DI fittings shall be same make as DI pipe or as per recommendation of DI pipe manufacturer.
Supply and fixing cast iron sluice valve 300 mm dia with flanged ends class PN 1.6 (heavy duty ISI marked) confirming to IS:14846-2000, drilled type, complete with stainless steel spindle, CI gate with brass ring, iron wheel handle, complete including jointing material such as nuts, bolts, washers and rubber sheet insertion 3.0mm thick at both ends etc complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing cast iron sluice valve 200 mm dia with flanged ends class PN 1.6 (heavy duty ISI marked) confirming to IS:14846-2000, drilled type, complete with stainless steel spindle, CI gate with brass ring, iron wheel handle, complete including jointing material such as nuts, bolts, washers and rubber sheet insertion 3.0mm thick at both ends etc complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing cast iron sluice valve 150 mm dia with flanged ends class PN 1.6 (heavy duty ISI marked) confirming to IS:14846-2000, drilled type, complete with stainless steel spindle, CI gate with brass ring, iron wheel handle, complete including jointing material such as nuts, bolts, washers and rubber sheet insertion 3.0mm thick at both ends etc complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing cast iron sluice valve 100 mm dia with flanged ends class PN 1.6 (heavy duty ISI marked) confirming to IS:14846-2000, drilled type, complete with stainless steel spindle, CI gate with brass ring, iron wheel handle, complete including jointing material such as nuts, bolts, washers and rubber sheet insertion 3.0mm thick at both ends etc complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing cast iron sluice valve 150 mm dia with flanged ends class PN 1.0 (heavy duty ISI marked) confirming to IS:14846-2000, drilled type, complete with stainless steel spindle, CI gate with brass ring, iron wheel handle, complete including jointing material such as nuts, bolts, washers and rubber sheet insertion 3.0mm thick at both ends etc complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing cast iron sluice valve 100 mm dia with flanged ends class PN 1.0 (heavy duty ISI marked) confirming to IS:14846-2000, drilled type, complete with stainless steel spindle, CI gate with brass ring, iron wheel handle, complete including jointing material such as nuts, bolts, washers and rubber sheet insertion 3.0mm thick at both ends etc complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing cast iron sluice valve 80 mm dia with flanged ends class PN 1.0 (heavy duty ISI marked) confirming to IS:14846-2000, drilled type, complete with stainless steel spindle, CI gate with brass ring, iron wheel handle, complete including jointing material such as nuts, bolts, washers and rubber sheet insertion 3.0mm thick at both ends etc complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing cast iron foot valve confirming to IS 4038, 100 mm dia with flanged valve ends swing type with rubber seat complete all as specified and as directed by Engineer-in-charge.
Supply and fixing 100mm valve gun metal reflex/NRV with by pass arrangement, PN 1.6 with flanged ends in swing type design, confirming to IS 5312 Part-I complete all as specified and as directed by Engineer-in-charge.
Supply and fixing cast iron tamper proof double orifice kinetic air release valve ISI marked with two air outlets, 80 mm dia bore and fixing up in cast iron water supply mains complete all as specified and as directed by Engineer-in-charge.
Supply and fixing horizontal split case centrifugal pump set minimum 30 HP, 1450 RPM, 02 stage having output of minimum 1300 LPM at a head of 50 meter coupled to three phase 415 volts of adequate capacity complete all as specified and as directed by Engineer-in-charge including following:- (a) Heavy grade GI tubing upto foot valve from suction end of pump. (b) Pressure guage (c) PCC foundation in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate, 20 cm above ground level and 30 cm below ground level including grouting of eye bolts nuts etc for pump set of adequate size or as per manufacturer's recommendations
Supplying, installing, commissioning and testing complete of manufacturer or OEM (Original Eqpt Manufacturer) manufactured and tested static Diesel Engine driven Generating Set, radiator cooled, with AMF panel capable of delivering 40KVA (32 KW) or nearest higher rating 415 volts AC 3 phase, 4 wire system of supply, 50Hz. The DG set shall consist of diesel engine coupled through flexible coupling to matching alternator and mounted on foundation pads on common base frame in the CPCB approved acoustic enclosure (the complete set confirming to and test certificate as per CPCB-IV norms and as specified) with AMF control panel standardised by manufacturer, inbuilt fuel tank, flexible exhaust pipe, incl necessary PCC foundation as per manufacturer instructions complete all as specified and as directed and comprising with the following:--
Engine (Prime mover) : Diesel Engine 1500 RPM of suitable BHP as recommended by manufacturer (at rated RPM), water cooled, multi cylinder, inline, 4 stroke, confirming to ISO 3046 / BS 5514 with turbo charged air cooled , 1x88 AH 12 Volts batteries start, mechanical FIP, Electronic Governor, pulse tuned exhaust manifold, stainless steel exhaust flexible connection complete with flywheel and all standard fittings/fixture as per manufacturing practice including suitable engine control panel with tachometer, lub oil temp and pressure gauge, water temp guage, starter, dynamo, fuel tank, fuel and lube oil filter, Dry type replaceable paper element air cleaner etc.
Alternator : AC alternator, self-excited, self-regulated, self-ventilated, brushless design, confirming to BS 2613/5000, 3 phase, 415 volts, 4 wire rated line current min 56 Amps output at PF 0.8, 1500 RPM, insulation class ‘H’ enclosure IP 23 complete with AVR with ± 1% voltage regulation, directly coupled to and matched with engine.
Anti-vibration pad for mounting engine alternator assembly on the base frame/plate.
Base frame/plate made out of structural steel as per manufacturer’s recommended design/specifications.
Acoustic Enclosure : Engine Alternator assembly mounted on AV mounts with silencer and SS exhaust bellow suitable optimised to meet stringent noise emission standards as laid down by MOEF/CPCB. Base rail with draw out type fuel tank provided with drain plug, air vent, inlet and out let connection, level indicator, manhole etc.
01 No 12 volt x 88 AH maintenance free batteries complete with suitable size copper lead.
AMF control panel : RAL 9003 white powder coated control panel made out of CRCA sheet provided with AMF system (automatic starting of main failure) and Start Stop push button for manual operating, provide with MCCB of suitable rating with short circuit protection, controller which display voltage, current, KW, PF, Frequency, KWH, lube oil pressure, indicating lamps for ‘load ON’ and ‘set running’ current transformer of suitable rating etc, aluminium bus bar of suitable rating with incoming and outgoing termination complete all as per manufacturer’s recommended design/specifications.
The contractor shall supply following maintemance spare part and tool kit for the generator set :- (i) Fuel filter - 02 Nos (ii) Lube oil filter - 01 No (iii) Air filter - 01 No (iv) V-belt - 02 Sets (v) Tool kit socket set - 01 No (vi) DE Spanner set - 01 No (vii) Ring Spanner set - 01 No (viii) Clamp meter - 01 No
Note :- (i) Any item left out for successful operation of AMF panel is deemed to be included in overall cost quoted. (ii) DG set should be sound proof as per latest policy (iii) Cost of maintenance free batteries as per recommendations of manufacture shall deemed included in unit rate quoted by contractor (iv) Cost of PCC foundation as per recommendations of manufacturer shall deemed included in unit rate quoted by contractor. (v) Initial filling of lubricating oil/coolant and fuel required for testing of DG set shall be provided by the contractor without any extra cost. (vi) Exhaust from DG set shall be as per latest CPCB [IV] norms. Alternatively emission control device within overall cost quoted shall be provided (vii) Pre commissioning test shall be carried out by rep of Accepting Officer. All necessary equipment’s, consumables and T&P required for successful completion of the test shall be arranged by the contractor and cost for the same shall deemed included in unit rate quoted by contractor. (viii) Contractor shall produce test certificate of DG set, no payment shall be allowed without test certificate.
Supply, installations, testing and commissioning of factory made LT Indoor cubical type panel board having 150 Amp rated copper bus bar with neoprene rubber gasket and locking arrangement, dust,weather and vermin proof , free standing, floor mounting type self ventilation with wire mesh,totally enclosed busbar chamber fully comparted type, front openable hinged independent door for each compartment with locking arrangement and common openable hinged door from rear side of suitable size made out of 2mm thick CRCA sheet duly painted with seven tank process,415 V,TPN,50Hz both side properly welded MS angular supported with chanel frame of size 50mm,at all vertical corner grouted in PCC 1:3:6 (Type-C1 using 20mm graded stone aggregate) and connecting the incomming/outgoing feeder by providing brass cable glands and Lugs complete all as specified and directed comprising of followings accessories (Pump Starter panel at Secondary Pump House)
INCOMING:
(a) MCCB 4 Pole 100 amps ,415 Volt of breaking capacity not less than 16 KA (Ics=100 % of Icu) with adjustable thermal Setting - 01 No.
(b) Copper Busbar 150 Amp
OUTGOING:
(c) MCCB 4 Pole 63 amps ,415 Volt of breaking capacity not less than 16 KA (Ics=100 % of Icu) with adjustable thermal Setting - 02 Nos
(d) MCB SPN 10 Amp C curve, 10 KA capacity - 01 No
(e) Single phase preventor -02 Nos
(f) On load Change over switch 4 pole of current raring 100 A (open execution type) - 01 No
(g) Indicator lamp (R,Y,B)
(j) Fully automatic star delta starter 3 phase 415 V suitable for pump set upto 30 HP -02 Nos.
Supply, installations, testing and commissioning of factory made LT Outdoor cubical type panel board with neoprene rubber gasket and locking arrangement, dust,weather and vermin proof , free standing, self ventilation with wire mesh,front openable hinged independent door for each compartment with locking arrangement and of suitable size made out of 3.15 mm thick CRCA sheet duly painted with seven tank process,415 V,TPN,50Hz both side properly welded MS angular supported with chanel frame of size 40mm,at all vertical corner grouted in PCC 1:3:6 (Type-C1 using 20mm graded stone aggregate) and connecting the incomming/outgoing feeder by providing brass cable glands and Lugs complete all as specified and directed comprising of one No MCCB 100A 4P 16kA for Main Incoming from existing Transformer complete all as specified and as directed by Engineer-in-Charge. Note:- Panel shall be mounted on angle iron frame of 04 nos legs made from angle iron of size 50 mm x 50mm x 5mm, legs shall be 750 mm long, 300 mm grouted in blocks pf PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) with 450 mm ground clearance.
Material and labour for Construction of brick masonary valve pit chamber size 120 X120 X120 cm (internal dimension) using sub class 'B' bricks complete including excavation & earth work, returning fillig and disposal of surplus soil to distance not exceeding 50m and deposited where directed, PCC (1:3:6) type C-2 using 40 mm graded stone aggregate in foundation, coping on top in PCC (1:2:4) type B-1 using 20 mm graded stone aggregate, brick work in cement mortar (1:4), inner plaster 12 mm thick in cm (1:3) finished even and smooth and pionting flush externally as the work proceeds in the same mortar, MS sheet cover 3.15mm thick mounted on angle iron frame of size 40 x 40 x 6mm with handle and locking arrangement duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and embeded portion of MS work duly applying black bitumenous paint before embeded complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Construction of brick masonary valve pit chamber size 90 X90 X90 cm (internal dimension) using sub class 'B' bricks complete including excavation & earth work, returning fillig and disposal of surplus soil to distance not exceeding 50m and deposited where directed, PCC (1:3:6) type C-2 using 40 mm graded stone aggregate in foundation, coping on top in PCC (1:2:4) type B-1 using 20 mm graded stone aggregate, brick work in cement mortar (1:4), inner plaster 12 mm thick in cm (1:3) finished even and smooth and pionting flush externally as the work proceeds in the same mortar, MS sheet cover 3.15mm thick mounted on angle iron frame of size 40 x 40 x 6mm with handle and locking arrangement duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and embeded portion of MS work duly applying black bitumenous paint before embeded complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Construction of brick masonary valve pit chamber size 75 X 75 X 75 cm (internal dimension) using sub class 'B' bricks complete including excavation & earth work, returning fillig and disposal of surplus soil to distance not exceeding 50m and deposited where directed, PCC (1:3:6) type C-2 using 40 mm graded stone aggregate in foundation, coping on top in PCC (1:2:4) type B-1 using 20 mm graded stone aggregate, brick work in cement mortar (1:4), inner plaster 12 mm thick in cm (1:3) finished even and smooth and pionting flush externally as the work proceeds in the same mortar, MS sheet cover 3.15mm thick mounted on angle iron frame of size 40 x 40 x 6mm with handle and locking arrangement duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and embeded portion of MS work duly applying black bitumenous paint before embeded complete all as specified and as directed.
Supply & Installed testing commissioning washing machine with in built hydro extractor of capacity 30 Kg (per Charge) front loading electrically heated and opertated stainless steel body, Microprocessor controlled fully automatic, auto time auto reverce, auto stop auto temp control, auto level control, Pneumatically operated valves for auto water inlet, auto steam inlet, auto drain, varriable frequency drive for varriable speed, stainless steel inner drum, outer drum and cladding. Heavy duty MS Fabricated structure complete all as specified and as directed.
Supply & Installed testing commissioning of Drying tumbler machine electrically heated and operated having loading type auto time, auto stop, auto reverse with fully die pressed door, Inner basket stainless steel of Capacity 30 Kg per charge complete all as specified and as directed.
Supply & fixing rotational moulded polyethylene water storage tank of capacity 2000 litres (cylindrical vertical, double layered with closed top), hoisted and fixed in position including inlet and out let connection complete all as specified and as directed.
Subtotal
Lump sum price worked out by the tenderer for “EXTERNAL ELECTRIFICATION AND LIGHTNING PROTECTION WORKS" as listed in Schedule ‘A’ Section - IX (Part-I)
Sch 'A' Sec - IX (Part-II), EXTERNAL ELECTRIFICATION AND LIGHTNING PROTECTION WORKS
Supply and fixing lightning arresters HT 11000 V non linear expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp, confirming to IS 3070 (Part-I) 1985 complete all as specified and as directed by Engineer-in-Charge.
Supply and Installation of platform mounted transformer 1000 KVA, 11/0.433KV, 50 Hz, step down, Indoor type, ONAN Cooled oil immersed copper wound transformer, complete with first filling of IS-335 ISI marked filtered & dehyrated tranformer oil and other standard fittings/acceesories and 7 position OFF circuit tap changer (Tapping range + 7.5% in steps of 2.5% Each) with vector group Dyn-11, having provision of OTI, WTI, Marshalling box, HV and LV cable box suitable for making connection of incomming HT cable and outgoing LT cable/sandwich type bus bar all as per IS 1180-2014 (Level-2) including all required accessories for installation of transformer all as specified and directed. Transformer shall comprises the folowing:- (i) Oil conservator tank with filter type drain plug and oil level guage. (ii) Dehydrating breather with first fill of silica gel. (iii) Buchholz relay - 01 No Make- mentioned in Appx 'B' of make list. Note:- (a) Pre commissioning test shall be carried out by SEI from HQ CE SWC or rep of accepting officer. all arrangement for the same shall be made by contractor with in over all cost quoted. (b) Cost for suitable size of transformer plinth shall deemed to be included in quoted price.
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of suitable size, indoor type (double door both side openable including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 2 mm thick powder coated and fully compartmentalized inner panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and brass cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 Nos legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 300 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 450 mm ground clearance, frame and legs duly spray painted with seven tank process internally and externally with two coats of synthetic enamel over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly rivited/ pasted to the panel board door, complete including all connection incoming/ outgoing all as directed by Engr-in-charge and comprising of following accessories:-
(a) Copper bus bar of 800 Amp capacity, 4 strip mounted on porcelain insulators. (b) MCCB 4 pole, 415 volt, 630 Amp, thermal/magnetic based 25 kA (Ics=100% of Icu) - 01 No. (Incomming). (c) Shunt Capacitor MPP type, heavy duty (capacitor shall discharge automatically with electraunic reactance dischrge kit of suitable rating in watt when power supply is switched off) 440 volt grade. (c) One No. CT of suitable ratio wih secondary of 05 Amp to be fixed on each bus bar. (d) Microprocessor based automatic power factor control relay unit, suitable for 08 No stages of capacitor bank 400 kVAR ( 2x100 + 2x50 + 4x25) in the following steps: - (i) Suitable for programming at site. (ii) Self adjusting switching sequence (iii) PF adjusting range upto 1 (iv) Auto calculation of C/K value. (v) Indication for operational state of capacitor LED type. (e) Contactors & relays for each capacitor as per capacitor rating.
Supply and installation of indoor type HT 11 KV, 3 phase, 50 Hz totally enclosed metal clad switchgear complete with vaccum circuit braker extendable suitable model to match the the exitsting system / panel board including jointing to existing panel ,having rupturing capacity 350 MVA, overload and earth fault protection , ammeter voltemeter and of rating upto 630 Amps. All the main components like VI/VCB/Relays/meters shall be of same make. (A) VCB panel parameters are as below:- (i) Rated Voltage level/PF withstand voltage/Impulse level : 12KV/28kV/75 KVp. (ii) Continuous current rating: minimum 630A. (iii) Short circuit withstand current : minimum 25 KA for 3 sec. (iv) The breaker shall be equiped with horizontal Busbar draw out type vacuum circuit breaker in 12 KV metal clad floor mounting panel complete with following :- (a) Manually and motor operated (230V, AC, 50Hz) spring charged type, manually and electrically open (electrical - 24VDC ) operation type, incorporating mechanical as well as electrical ON/OFF indication "OFF" push button, test/service position limit switches, with minimum 6NO+6NC breaker auxiliary contact in service position. (b) manual charging of breaker should be done without opening the front door. (c) Cast resin current transformer 11KV, 50-25/5A, Core1: class 1, 15VA for 3 phase, core2 : 5P10, 15VA (d) Cast resin potential transformer 11KV/V3/110V/V3/110V/3, 50 VA, CI 1.0, CI 3P, and HT fuse at the primary end and 04 pole MCB at the secondary end of the PT (conforming related IS specification).
Material and labour for boring of holes under main road pavement, hard standing or any other situation by manual mean for accommodate 40mm to 100mm bore GI tube (light grade) in the drilled holes, including returning, filling in the end working space including removal of surplus soil and making good the surface complete all as specified and as directed. Note ; (GI pipe and cable shall be measured and paid separately)
Supply, installations, testing and commissioning factory made indoor cubical type LT panel board dust and vermin proof , free standing, floor mounting type mounted on and incluidng 1:3:6 PCC foundation as requried at site and of fabricated by 2.0 mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frame of requried type for support with double door both sides open type with necessary locking arrangement with slopped roof on top duly painted with two coats of powder coated semense gray paint complete and having separate doors inside for accomodating all incomming / out going feeders of suitable sizes all as specified and directed by Engr-in- Charge :- (Main Transformer Panel):- Incomming :- (a) Air circuit breaker 4 Pole 1600 amps ,415 Volt of breaking capacity not less than 50 KA with electronic/ micro processor release(EDO type).-01 Nos (b) Copper Busbar 2500 Amps current rating duly sleeve insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs-01 Set OUTGOING
(d) S&F MCCB 4 Pole 100 amps ,415 Volt of breaking capacity not less than 25 KA (Ics=100 % of Icu) with Adjustable TM Range (for Adm Block Panel, SM bk panael AD wksp, Offrs Mess Panel, Prop panel MI Room Ph-ll )-04 Nos (e) S&F MCCB 4 Pole 200 amps ,415 Volt of breaking capacity not less than 25 KA (Ics=100 % of Icu) with Adjustable TM Range (for Adm Block AD Wksp Panel )-01 Nos (f) S&F MCCB 4 Pole 250 amps ,415 Volt of breaking capacity not less than 25 KA (Ics=100 % of Icu) with Adjustable TM Range (for SM Bk AD Regt Panel)-01 No (g) S&F MCCB 4 Pole 320 amps ,415 Volt of breaking capacity not less than 25 KA (Ics=100 % of Icu) with Adjustable TM Range (for JCO Mess Panel)-01 No (h) S&F MCCB 4 Pole 630 amps ,415 Volt of breaking capacity not less than 36 KA (Ics=100 % of Icu) with Adjustable TM Range (for Heat Pump & Mech Laundry)-01 No (j) MCB SPN 16 Amp, 415 V, 10 KA, C-series(Street light G room & spare) - 02 Nos (k) MCB TPN 16 Amp, 415 V, 10 KA, C-series - 02 Nos (l) Astronomical Digital Programmable Timer Switch using power contactor 16A 3 Pole 415 V DIN type time swtich - 01 No (m) Multi function meter with CT of suitable size– 01 No. (n) LED Indicating Lamps R,Y,B - 01 Set of three Note:- Panel shall be mounted on angle iron frame of 04 nos legs made from angle iron of size 50 mm x 50mm x 5mm, legs shall be 750 mm long, 300 mm grouted in blocks pf PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) with 450 mm ground clearance.
Supply, installations, testing and commissioning factory made out door cubical type LT panel board dust and vermin proof , free standing, floor mounting type mounted on and incluidng 1:3:6 PCC foundation as requried at site and of fabricated by 3.0 mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frame of requried type for support with double door both sides open type with necessary locking arrangement with slopped roof on top duly painted with two coats of powder coated semense gray paint complete and having separate doors inside for accomodating all incomming / out going feeders of suitable sizes all as specified and directed by Engr-in- Charge :- (Panel A - Adm Block Panel):- Incomming :- (a) S&F MCCB 4 Pole 100 amps ,415 Volt of breaking capacity not less than 25 KA (Ics=100 % of Icu) with Adjustable TM Range, (b) Copper Busbar 150 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs OUTGOING (c) MCCB 4 Pole 80 Amp, 415 V, 18 KA (for Adm Block) (d) MCB SPN 6-10A 230V 10 KA C series (for Car parking Garrage) (e) MCB TPN 16 Amp, 415 V, 10 KA, C-series (01 for street light and 01Spare) - 02 Nos (f) Astronomical Digital Programmable Timer Switch using power contactor 16A 3 Pole 415 V DIN type time swtich 230V (i) Multi function meter with CT of suitable size – 01 No. (k) LED Indicating Lamps R,Y,B - 01 Set of three
Supply, installations, testing and commissioning factory made out door cubical type LT panel board dust and vermin proof , free standing, floor mounting type mounted on and incluidng 1:3:6 PCC foundation as requried at site and of fabricated by 3.0 mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frame of requried type for support with double door both sides open type with necessary locking arrangement with slopped roof on top duly painted with two coats of powder coated semense gray paint complete and having separate doors inside for accomodating all incomming / out going feeders of suitable sizes all as specified and directed by Engr-in- Charge :- (Panel B - Offrs Mess Panel):- Incomming :- (a) S&F MCCB 4 Pole 100 amps ,415 Volt of breaking capacity not less than 25 KA (Ics=100 % of Icu) with Adjustable TM Range - 01 Nos (b) Copper Busbar 150 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs - 01 Set Ootgoing:- (c) MCCB 4 Pole 63 Amp, 415 V, 18 KA - 01 No. (for Offrs Mess) (d) MCB TPN 16 Amp, 415 V, 10 KA, C-series - 03 Nos (Guard house, 01 for street light and 01Spare) (e) MCB SPN 10 Amp, 415 V, 10 KA, C-series - 02 Nos (f) Astronomical Digital Programmable Timer Switch using power contactor 16A 3 Pole 415 V DIN type time swtich 230V (g) Multi function meter with CT of suitable size– 01 No. (h) LED Indicating Lamps R,Y,B - 01 Set of three
Supply, installations, testing and commissioning factory made out door cubical type LT panel board dust and vermin proof , free standing, floor mounting type mounted on and incluidng 1:3:6 PCC foundation as requried at site and of fabricated by 3.0 mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frame of requried type for support with double door both sides open type with necessary locking arrangement with slopped roof on top duly painted with two coats of powder coated semense gray paint complete and having separate doors inside for accomodating all incomming / out going feeders of suitable sizes all as specified and directed by Engr-in- Charge :- (Panel C - SM Bk panel):- Incomming :- (a) S&F MCCB 4 Pole 250 amps ,415 Volt of breaking capacity not less than 25 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0)) - 01 No incoming. (b) Copper Busbar 400 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs-01Set OUTGOING :- (c) MCCB 4 Pole 40 Amp, 415 V, 18 KA - 05 Nos (for SM Bk Both Side) (d) MCCB 4 Pole 63 Amp, 415 V, 10 KA - 03 Nos(for Cook House/DH ). (e) MCB SPN 6-10A 230V 10 kA C Series (LPG Store and Garrages) - 04 Nos (f) MCB TPN 16 Amp, 415 V, 10 KA, C-series ( 01 for Street Light and 01 Spare) (g) Astronomical Digital Programmable Timer Switch using power contactor 16A 3 Pole 415 V DIN type time swtich 230V- 01 Nos (h) Multi function meter with CT of suitable size - 01 No. (j) LED Indicating Lamps R,Y,B - 01 Set of three
Supply, installations, testing and commissioning factory made out door cubical type LT panel board dust and vermin proof , free standing, floor mounting type mounted on and incluidng 1:3:6 PCC foundation as requried at site and of fabricated by 3.0 mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frame of requried type for support with double door both sides open type with necessary locking arrangement with slopped roof on top duly painted with two coats of powder coated semense gray paint complete and having separate doors inside for accomodating all incomming / out going feeders of suitable sizes all as specified and directed by Engr-in- Charge :- (Panel D - JCO Mess panel):- Incomming :- (a) S&F MCCB 4 Pole 320 amps ,415 Volt of breaking capacity not less than 36 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0) - 01 No incoming. (b) Copper Busbar 500 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs-01Set OUTGOING :- (c) MCCB 4 Pole 125 Amp, 415 V, 25 KA, C-series - 01 Nos (for SM Bk AD wksp Panel). (d) MCCB 4 Pole 32 Amp, 415 V, 18 KA, C-series - 05 Nos (for Sin JCOs and Tech Store) (e) MCCB 4 Pole 63 Amp, 415 V, 18 KA, C-series - 02 Nos (for JCOs Mess and Prop Panel for Ph-ll ). (f) MCB SPN 10A 230V C Series (Storage Accn)- 01 Nos (g) MCB TPN 16 Amp, 415 V, 10 KA, C-series ( 01 for Street Light and 01 Spare) (h) Astronomical Digital Programmable Timer Switch using power contactor 16A 3 Pole 415 V DIN type time swtich 230V- 01 (j) Multi function meter with CT of suitable size - 01 No. (k) LED Indicating Lamps R,Y,B - 01 Set of three
Supply, installations, testing and commissioning factory made out door cubical type LT panel board dust and vermin proof , free standing, floor mounting type mounted on and incluidng 1:3:6 PCC foundation as requried at site and of fabricated by 3.0 mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frame of requried type for support with double door both sides open type with necessary locking arrangement with slopped roof on top duly painted with two coats of powder coated semense gray paint complete and having separate doors inside for accomodating all incomming / out going feeders of suitable sizes all as specified and directed by Engr-in- Charge :- (Panel G - SM Bk panel):- Incomming :- (a) S&F MCCB 4 Pole 630 amps ,415 Volt of breaking capacity not less than 25 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0)) - 01 No incoming. (b) Copper Busbar 800 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs-01Set OUTGOING :- (c) MCCB 4 Pole 160 Amps, 415 V, 25 KA - 01 No (d) MCCB 4 Pole 100 Amp, 415 V, 10 KA, C-series - 04 Nos (for 4 Nos heat pump) (e) Multi function meter with CT of suitable size - 01 No. (f) LED Indicating Lamps R,Y,B - 01 Set of three
M&L for factory made busbar box 32 Amps rated Aluminium busbar, 3 phase, 4 wire, 415 Volt of size not less than 300mm x 200mm x 100mm, fabricated using 1.6mm MS sheet, duly painted with smoke gray powder coated over a coat of red oxide primer suitable for fixing on wal by using wall fastners 10mm dia and making necessary incomming and outgoing connection of electric cables using aluminium lugs all as specified.
Supply and fixing energy efficient LED street light fittings of 45 W capacity including electric connection, complete fitting including all accessories and following specification and all as directed by Engr-in-charge. (a) Lumen system efficacy of luminarie should be minimum 110 Lumen per watt. (b) Input voltage range 140 to 270 volts (c) Temp operating range minimum 10°C to Plus 50°C (d) Power factor : minimum 0.95 (e) THD : Max 10% (f) CRI : More than 80 and CCT : 5700 K (g) IP rating : IP66 (h) IK rating : Minimum IK07 (j) Pressure die cast aluminium alloy for housing and heat resistant alear toughened glass (k) Built in potted LED driver of the make as of the luminaire. (l) LED driver should be complete with all protection viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (m) Surge protection 10 kV (inbuilt + extended) (n) Lens:- High sfficiency wide angle lens (o) BIS approved fixtures and driver (p) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily)
Supply and connecting three core cord flexible wire, copper conductor multistranded, PVC insulated and overall PVC sheathed of size 1.5 Sqmm 1100 Volt , draw through LT steel tubular poles for connection to street light from junction box all as directed.
Supply and fixing Cable route indicator, duly engraved with 'LT CABLE 1100 VOLT' on cast iron round plate 150 mm dia and 8mm thick with provision of 500 mm long (minimum) single leg/stand of angle iron 40x40x5 mm, welded/riveted on back side of plate, fixed and grounted in position with with PCC (1:3:6) type C-1, using 20 mm graded stone aggregate block of suitable size complete all as specified and as directed by Engineer-in-Charge.
Material and labour for cable route indicator of size 500x300x100mm grouted in ground with precast cement concrete (1:2:4) type B-1, using 20mm graded stone aggregate, rounded tops as directed and embeded in ground of size 350x150x200mm including 10 mm thick plasteringall around of exposed surfacesof post above ground with CM (1:4) and applying two coats of cement base paint on plastered surface including writing letters (like LT/HT UG cable, __ feeder etc.) with synthetic enamel paint in brown colour in suitable size including earth work and form work complete all as specified and as directed.
S&F sandwitch type bus bar trunking system with copper bus bar 2500 Amps 50 KA breaking capacity IP 54 protection by compact duct sheet metal enclosures square/ rectangular from Transformer to Main panel including all accessories and arrangements. (12 Mtrs of Cu Sandwich busbar alongwith compact duct sheet metal enclosures square/ rectangular from Transformer to Main panel including all copper flanged end, bend and fixing accessories and arrangements.)
Material and labour for PCC 1:3:6 type C1 (using 20 mm graded stone aggregate), casting in cube of size required at site using necessary formwork for fixing arial pointers with base for lightening ptotection system complete all as specified and as directed.
Supplying, erecting, testing and commissioning Raising and Lowering type (min 12 metre height high mast system hot dip galvanised inside and outside) in single dip, suitable for wind velocity as per IS 875 part 3 with only one longitudinal seam weld per section but without circumferential weld including accessories viz head frame , 2 point suspension system with steel wire rope 6 mm dia 7/ 19 gauge, double drum winch, galvanised lantern carriage arrangement suitable for and with 6 nos Luminaires symetrically lightning finial, LED aviation obstruction light of 9/10 watt, lighting arrestor spikes, foundation bolts,nuts, anchor plates, templates, trailing cable and intergral power tool for raising and lowering operation of high mast with and including following technical specifications:- (a) HIGH MAST SYSTEM:- Height of Mast –min 12 mtr, No of sections - two (b) Material construction - S355 grade as per BS-EN10025 Base dia and top diameter (A/F) - 360 mm and 150 mm respectively, Plate thickness and - Top - 3mm, Bottom- 3mm, Cross section of Mast - 20 side polygon, standard for of galvanisation - As per BS EN ISO 1461/BS729/IS2629 Size of opening and door at base - 1200 mm X 250 mm, Diameter of base plate - 520 mm, Thickness of base plate - 25 mm, Lightning protection finial - GI single spike, Maximum Wind speed - 50 m/s as per IS 875 (Part-III), Number of foundation bolts - 6 Nos, PCD of foundation bolts - 445 mm, Type/diameter/length of foundation bolts - TS 600/24 mm dia/850 mm long, Diameter of carriage ring (mm) - 535 mm (ID) minimumum, Construction - 8 arm welded 2 sections, Load carrying capacity 8 Luminarie (c) WINCH / POWER TOOL Type/SWL of winch - Double Drum /SWL 350 Kg Method of operation - Integral Motor I Motor Capacity - 1 HP Three Phase No of Speed - 6 Pole, Single Speed 128.03 (d) STAINLESSS STEEL WIRE ROPE grade/Construction - AISI304.7/I9 Construction No of Ropes - Two continuous Diameter (mm) - 5 mm Braking load capacity (minimum) - 1450 Kg x 2128.04.
Note:- All as per manufacturer recommendations (e) FEEDER PILLAR Powder coated CRCA steel sheet feeder piller for outdoor application with 63 amp four pole MCB incomer, Nature switch, 16 amp, 420 volts suitable for automatic switching ON and OFF of the luminaries, 9 Amp two contactors andraise lower push buttons for motor operation, incoming terminals of 50 Sqmm and outgoing terminals of 16 sqmm for power cable and 2.5 sqmm for motor mounted on suitable foundation (f) FOUNDATION Construction of suitable shallow foundation with M20 gradeconcrete for high mast considering the safe soil bearing capacity at siteas 10T/sqm at 2 m depth (g) TRAILING CABLE PVC insulated PVC scheathed 1100 volt grade ISI marked multistranded copper conductorcable 6 core 2.5 sqmm
(h) FLOOD LIGHT LUMINAIRE :- Six number LED flood light luminaires having a nominal system lumen output of minimum 15000 lumens at a minimum system efficacy of 100 lumens per watt and total powerconsumption not more than 150 watt including driver. it has a rated system life time of 50000 burning hours at L70 and should have a color temperature of 6500 K, CRI>80, THD<10% andPF>0.95 complete & surge protection not less than 10KV. (J) Automatic light control switch with infrared sensor based Nature Switch & voltage monitoring system (VMS). Nature switch operation should bebased on Natural Light Luxlevel. Required illuminance level for Switching ON is < 30 Lux and for Switching OFF > 10Lux. The Sensor should also have pert night operation facilityty of min. 4 hrs. to max 12 hrs.VMS should have Adjustable Over & Under Voltage Trip level and Protection against PhaseLoss, Neutral Loss & Phase Reverse. The sensor & VMS along with suitable PowerContractor(s) and Incoming-Outgoing MCBs should be enclosed in a pole/wall mountable, Enclosure made of Rust Proof, Electric Shock Proof, Terminate proof and FR grade SMCJunction box conforming to IP54. The circuit should also have provision for Manual Operation (i.e. sensor & VMS By-Pass option) with 3nos. Contactors, 3 nos. IncomingMCBs & 3 nos. Outgoing MCBs of 16-20 Amps each & Circuit wiring complete all as specified.
Subtotal
Lump sum price worked out by the tenderer for “SUMMER APPLIANCES, AIR CONDITIONING AND HOT WATER APPLIANCES WORKS" as listed in Schedule ‘A’ Section - X (Part-I)
Sch 'A' Sec - X (Part-II) , SUMMER APPLIANCES, AIR CONDITIONING AND HOT WATER APPLIANCES WORKS
Supply, installing, commissioning and testing frost free refrigerator electric driven single phase 220 volts, AC 50 Hz, 250 ltrs or next higher capacity with BEE approved, minimum 3 star rating double door, stablizer free operation, Inverter Technology, R600a Refrigerant, tempered glass self, deodorizer and with fruit & vegitable drawer complete all as specified and as directed. Note (a) Contractor shall submit original purchase voucher and warranty card as recommended by manufacturer.
Supply, installing, commissioning and testing frost free refrigerator electric driven single phase 220 volts, AC 50 Hz, 400 ltrs or next higher capacity with BEE approved, minimum 3 star rating double door, stablizer free operation, Inverter Technology, R600a Refrigerant, tempered glass self, deodorizer and with fruit & vegitable drawer complete all as specified and as directed. Note (a) Contractor shall submit original purchase voucher and warranty card as recommended by manufacturer.
Supply, installing, commissioning and testing of metal top deep freezer single phase 240 V, 50 Hz, 320 ltrs or next available higher capacity having single door, direct cool evaporator type, refrigerant R600a, caster lock, Temp range < - 18⁰C, Analogue temp setting, magnetic door gasket, caster wheel, inside aluminium cladding, including all inbuilt accessories complete all as specified and as directed. Note (a) Contractor shall submit original purchase voucher and warranty card as recommended by manufacturer.
Supply, installing, commissioning and testing Water Cooler fully stainless steel (anti corrosive pre coated body), electric driven single phase having approx storage capacity of 40 Ltr and nominal cooling capacity of 40 Ltr per hour energy efficient compressor & Eco friendly refrigerant R-134a, with float valve and inlet PVC connection pipe of size 15 mm dia and 600 mm long of good quality complete with both ends CP nuts including electric connection through Voltage stablizer complete all as specified and as directed. Note (a) Contractor shall submit original purchase voucher and warranty card as recommended by manufacturer.
Supply, installing, commissioning and testing Water Cooler fully stainless steel (anti corrosive pre coated body), electric driven single phase having approx storage capacity of 80 Ltr and nominal cooling capacity of 40 Ltr per hour energy efficient compressor & Eco friendly refrigerant R-134a, with float valve and inlet PVC connection pipe of size 15 mm dia and 600 mm long of good quality complete with both ends CP nuts including electric connection through Voltage stablizer complete all as specified and as directed. Note (a) Contractor shall submit original purchase voucher and warranty card as recommended by manufacturer.
Supply, installing, commissioning and testing Water Cooler fully stainless steel (anti corrosive pre coated body), electric driven single phase having approx storage capacity of 120 Ltr and nominal cooling capacity of 60 Ltr per hour energy efficient compressor & Eco friendly refrigerant R-134a, with float valve and inlet PVC connection pipe of size 15 mm dia and 600 mm long of good quality complete with both ends CP nuts including electric connection through Voltage stablizer complete all as specified and as directed. Note (a) Contractor shall submit original purchase voucher and warranty card as recommended by manufacturer.
Supply and Installation of Desert cooler plastic body of size 65.5 x 63.4 x 77.3 cm or next available higher size, electric driven single phase 240 volts, 155 W, with suitable trolley and castor wheels complete all as specified and idrected by engr in charge Note: (a) Contractor shall submit original purchase voucher and warranty card as recommended by manufacturer. (b) Serial Number as issued by Engr-In-Charge of cooler and GE Office name shall also be written on cooler with red colour permanent marker or paint, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account
Supply & installing of Voltage stabilizer for automatic operation having input & output voltage, Amps, Over & low voltage cutout and timer delay function etc digital display single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 1 KVA with wall mounting bracket complete all as specified and as directed. Note (a) Contractor shall submit original purchase voucher and warranty card as recommended by manufacturer.
Supply & installing of Voltage stabilizer for automatic operation having input & output voltage, Amps, Over & low voltage cutout and timer delay function etc digital display single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2 KVA with wall mounting bracket complete all as specified and as directed. Note (a) Contractor shall submit original purchase voucher and warranty card as recommended by manufacturer.
Supply & fixing rotational moulded polyethylene water storage tank of capacity 1000 litres (cylindrical vertical, double layered with closed top), hoisted and fixed in position including inlet and out let connection complete all as specified and as directed.
Supply & fixing rotational moulded polyethylene water storage tank of capacity 500 litres (cylindrical vertical, double layered with closed top), hoisted and fixed in position including inlet and out let connection complete all as specified and as directed.
Supply, installing, commissioning and testing of electric water heater (Geyser) storage type ABS body of capacity 50 litres, BEE approved 5 Star rating, 230 V , single Phase, AC supply, inner tank made out of heavy duty stainless steel sheet (Designed with single weld line, factory tested with hydraulic pressure as per latest IS code) with glass lined coating complete with all accessories such as safety valve, thermostate, NRV, connection piece PVC connection 600mm long heavy duty suitable for Hot and cold water, three core PVC insulated PVC Sheathed copper conductor flexible cable, 04 Nos suitable size mild steel L-Hook fastener with washer for hanging the geyser and making good the disturbed surface complete all as specified and directed by Engr-in-Charge.
Supply, fixing, commissioning and testing Air cooled Heat Pump delivering actual capacity as per the following parameters. Heat Pump shall be rated at nominal input power 2,22 KW with output heating capacity 8 KW electrical backup 12 KW having inbuilt tank capacity – 455 litres having glass lining. Water temp in efficiency mode using compressor should be 65 degrees C. heat Pump should have all the safety protections like high/low voltage, high temperature, refrigerant leak, compressor overheating protection with operational noise level not more than 60 dbA. Heat pump should have a user friendly control panel to set the desired temperature showcasing the actual temp also with flexibility of installing the same 15-30m away from the heat pump also Complete all as specified and directed
Supply, fixing, commissioning and testing Air cooled Heat Pump delivering actual capacity as per the following parameters. Heat Pump shall be rated at nominal input power 200 watt with output heating capacity 540 KW electrical backup 2 KW having inbuilt tank capacity – 80 litres having glass lining. Water temp in efficiency mode using compressor should be 65 degrees C. heat Pump should have all the safety protections like high/low voltage, high temperature, refrigerant leak, compressor overheating protection with operational noise level not more than 60 dbA. Heat pump should have a user friendly control panel to set the desired temperature showcasing the actual temp also with flexibility of installing the same 15-30m away from the heat pump also Complete all as specified and directed
Supply, fixing, commissioning and testing of pump vendors for 1 year warranty period of package SS304 horizontal hydropneumatics system, comprising of 1 No electrical driven pump of 1 LPS to a head of 30 meter with all accessories coupled to motor suitable for operation on 240/415 volts, 1/ 3 phase 2900 RPM, including with motor with 24 litres of pressure vessel having 1 working and 1 standby option mounted on the same sking along with control panel. Complete all as specified and directed
Supply and fixing (concealed in wall or as directed) single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amps, 240 volts, AC supply complete all as specified and directed by Engineer-in-Charge.
Material and labour for concealed sub main wiring (using colour coding such as red, black, white, green colour or as directed) with 2.5 Sqmm single core (03 run i.e 2 runs for main phase and neutral, 01 run for continues as earth wire) FRLSH PVC insulated unsheathed multistrand copper conductor cable 1100 volt drawn through and including PVC conduit 25mm dia (medium quality ISI marked), for independent circuit including all fitting arrangement i.e. PVC clamp, rawl plug, screw, PVC junction box, tee, bend etc. and including cutting of chases in wall and making good disturbed surfaces of walls as per original complete all as specified and as directed. Note :- Three runs of copper conductor cable and one run of PVC conduit including accessories shall be measured and paid as one unit (one RM length) for payment and extra length of cables required for connection to MCBs/DB shall not be measured and the cost for the same shall deemed to be included in the unit rate.
Material and labour for concealed sub main wiring (using colour coding such as red, black, white, green colour or as directed) with 4 Sqmm single core (03 run i.e 2 runs for main phase and neutral, 01 run for continues as earth wire) FRLSH PVC insulated unsheathed multistrand copper conductor cable 1100 volt drawn through and including PVC conduit 25mm dia (medium quality ISI marked), for independent circuit including all fitting arrangement i.e. PVC clamp, rawl plug, screw, PVC junction box, tee, bend etc. and including cutting of chases in wall and making good disturbed surfaces of walls as per original complete all as specified and as directed. Note :- Three runs of copper conductor cable and one run of PVC conduit including accessories shall be measured and paid as one unit (one RM length) for payment and extra length of cables required for connection to MCBs/DB shall not be measured and the cost for the same shall deemed to be included in the unit rate.
Supply & installing of Voltage stabilizer for automatic operation having input & output voltage, Amps, Over & low voltage cutout and timer delay function etc digital display single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA with wall mounting bracket complete all as specified and as directed.
Supply & installing of Voltage stabilizer for automatic operation having input & output voltage, Amps, Over & low voltage cutout and timer delay function etc digital display single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA with wall mounting bracket complete all as specified and as directed.
Supply & fixing PVC connection 15 mm size with PTMT nuts of length 450 mm suitable for hot and cold water and fixed complete all as specified and as directed.
Supply, installation, testing & commissioning of commercial air curtain unit of size 64" x 84 " for prevention of dust and conditioned air losses, single phase, 220 V, 50 Hz, made out of MS/CRCA sheet of minimum thickness 18 guage finished with two coats of red oxide primer and final coat of and final coat of synthetic enamel paint (ovenbaked) with MS-CRC 18 guage square perforated suction grills, aluminium alloy fans and single phase electric motor, nozzles etc, complete with fittings and accessories so as to produce 1-1.5 m/ sec air velocity at floor level for door opening complete all as specified and as directed.
Supply, installation, testing & commissioning of LPG manifold header 1” flanged end with 05 cylinder configuration for LPG VOT cylinders, made of MS Sch 40 pipe designed to manage the gas supply from 05 LPG cylinders simultaneously incl connectors, pressure relief valve, NRV, pressure gauge, pressure regulator, control valves for 05nos inlet and 05 Nos outlet, LPG grade distribution pipe of size ¾” with all fittings for connection to gas stoves 05 Nos upto 15 mtr length complete all as specified and as directed.
Supply, installing and commissioning stainless steel chimney (Kitchen ventilation system) size of hood 80” x 48” x 20” of SS-304 grade steel sheet having thickness not less than 16 SWG designed to remove grease-laden air, smoke and heat. Chimney hood shall be double walled, insulated and high efficiency washable Grease filters to capture grease particles. Chimney shall be mounted/hanged from roof of kitchen with anchor rods of size not less than 8mm dia complete as per manufacturer instructions.
Supply assembly and erection of GI sheet with C & SS rectangular/square duct made of ‘L’ shaped hollow profile duly factory boxed, incl all accessories such as corner, cleat, carriage bolt, gasket and appropriate sealant in longitudinal joints etc complete of size 24 gauge complete all as specified and as directed by Engineer-in-charge.
Supply, installation & commissioning of axial fan 450mm sweep single phase 1400 RPM 50 Hz 1 HP 4000 CFM suitable for fixing in chimney duct complete all as specified and as directed by Engineer-in-charge.
Subtotal
Sch 'A' Sec - XI , (EOT CRANE WORKS)
Supply, installation, testing & commissioning of Electric operated crane complete with span 9-10 meters of working capacity 2.0 Ton, 5.5 mtrs lift complete all as specified and as directed including following specifications : (a) Capacity (Safe Working Load) : 2.0 Ton (b) Span : 9-10 Mtrs. (Approx.) (c) Lift : 5.5 Mtrs. (Approx.) (d) Type : Double Girder (e) Speed (Hoisting) : 3 MPM (f) Speed (Cross Travel) : 8 MPM (g) Speed (Long Travel) : 10 MPM (h) Motors : Sq. cage crane duty (S4) motor as per IS:325 (i) Motor HP : (Hoisting) 3 HP x 1 No. (j) Motor HP (CT) : 1 HP x 1 No. (k) Motor HP (LT) : 0.5 HP x 2 Nos. (l) Class & Duty : M6, Medium (m) Design Standard : As per IS:3177 & 800
(n) Wire Rope : 8 mm. x 4 fall, 6 x 36 const. FMC Usha Martin, Mahadev or equivalent make (o) Operation : Through hanging pendent push button (p) Control Voltage : 110 /24 V (q) Supply Voltage : 400 / 440 V.; 50 Hz, AC (r) Material of Wheel : Forged Steel (s) Type of hoisting brake : Electro Magnetic shoe type brake -Fail to safe (t) Type of coupling : M.S.Fabricated or casted (u) Type of Bearings : Antifriction Ball/ Roller Bearings (v) Type of gear box : Totally enclosed splash lubricated (w) Type of hook : Shank type, made of forged steel, supported on thrust bearing (x) Bridge girder : Standard Joist with inverted channel / Box type fabrication from plate, max. deflection of main girder limited to 1 / 900th span of live loads including the weight of the hoist. (y) Cross Conductor : Festoon type trailing cable with festoon trolley & track (z) L.T. Mechanism : Double Motor (Twin) drive (aa) L.T. DSL : Bus Bar type Note:- Higher capacity motor if required as per design of OEM shall be provided without any extra cost to department.
Supply, installation, testing & commissioning of Electric operated crane complete with span 9-10 meters of working capacity 5 Ton, 5.5 mtrs lift complete all as specified and as directed including following specifications : (a) Capacity (Safe Working Load) : 5 Ton (b) Span : 9-10 Mtrs. (Approx) (c) Lift : 5.5 Mtrs. (Approx) (d) Type : Double Girder (e) Speed (Hoisting) : 3 MPM (f) Speed (Cross Travel) : 8 MPM (g) Speed (Long Travel) : 10 MPM (h) Motors : Sq. cage crane duty (S4) motor as per IS:325 (i) Motor HP : (Hoisting) 7.5 HP x 1 No. (j) Motor HP (CT) : 2 HP x 1 No. (k) Motor HP (LT) : 2 HP x 2 Nos. (l) Class & Duty : M6, Medium (m) Design Standard : As per IS:807, IS:3177 & 800
(n) Wire Rope : 12 mm. x 4 fall, 6 x 36 const. FMC Usha Martin, Mahadev or equivalent make (o) Operation : Through hanging pendent push button (p) Control Voltage : 110/24 V (q) Supply Voltage : 400 / 440 V.; 50 Hz, AC (r) Material of Wheel : Forged Steel (s) Type of hoisting brake : Electro Magnetic shoe type brake -Fail to safe (t) Type of coupling : M.S.Fabricated or casted (u) Type of Bearings : Antifriction Ball/ Roller Bearings (v) Type of gear box : Totally enclosed splash lubricated (w) Type of hook : Shank type, made of forged steel, supported on thrust bearing (x) Bridge girder : Standard Joist with inverted channel / Box type fabrication from plate, max. deflection of main girder limited to 1 / 900th span of live loads including the weight of the hoist. (y) Cross Conductor : Festoon type trailing cable with festoon trolley & track (z) L.T. Mechanism : Double Motor (Twin) drive (aa) L.T. DSL : Bus Bar type Note:- Higher capacity motor if required as per design of OEM shall be provided without any extra cost to department.
Subtotal
Lump sum price worked out by the tenderer for “HARD STANDING WORKS" as listed in Schedule ‘A’ Section - XII
Lump sum price worked out by the tenderer for “EXCAVATION, EARTHWORK AND SITE DEVELOPMENT WORKS" as listed in Schedule ‘A’ Section - XIII
Schedule 'A' Section -XIV (Furniture Works)
Almirah medium Steel Drg No. FD-1032
Almirah large Steel Drg No. FD-1031
Bar Stool 3' with back & Hydraulic device Drg No. FD-354
Book Case Steel Glazed Large Drg No. FD-1028 & 1028A
Chair Dining with long back Drg No. FD-357
Chair Easy Cushioned Drg No. FD-358
Chair Varandah PVC seat and back Drg No. FD/Map-II/15
Chair wiriting offrs steel Drg No. FD/E6/Map/12
Hat stand with mirror Drg No. FD-361
Hot case Large Drg No. FD-364
Magazine Rack Med Drg No. FD-365
Notice Board 900x600mm Med Drg No. FD-366
Plate Rack Stainless Steel (Size 24"x30"x10") Drg No. TP
Receptacle with Bucket FD-1045
Meat safe and milk Large Drg No. FD-370
Sofa Set 5 Seater Model No. RIOPLUS Make Godrejor Equivalent model of Royal Roas Delite Kom
Stool Dressing cushioned Drg No. FD/E6/MAP/14
Table Centre (Glass Top) Drg No. FD-375
Table dining 8 pers Drg No. FD-273
Table Cook House size 900x540mm Drg No. FD-297
Table Dresing Ladies with Mirror Drg No. FD-378
Table Dresing Gents with Mirror Drg No. FD-379
Table Pantry Steel Drg No. FD-1020
Table office officers steel Drg No. FD-1003
Teapoy Wooden Drg No. FD-278
Teapoy Verandah Offrs MAP Drg No. FD/E6/MAP/17
Table Peg Drg No. FD-384
Table Card Drg No. FD-352
Side Board Drg No. FD-371
Chair wiriting MAP without arms Drg No. FD/E6/MAP/12
Bath Mat PVC Drg No. FD/E6/MAP/07
Bed Hard Steel Drg No. FD/E6/MAP/8R
Chair Easy Drg No. FD-229
Chair writing Drg No. FD-280
Table Bed Side Offrs Drg No. FD/E6/MAP/15R
Table Writing Drg No. FD-275
Chair Computer Drg No. FD/E6/Map/01
Display Board Drg No. FD-99
Drugget 3mtrx2mtr
Side Rack With Tray Drg No. FD-1023
Sofa Set 2 Seater Drg No. FD-281
Stool steel 305x305x610mm Drg No. FD-409
Mattress 6'x'3' Make Kurl-on or Equivalent of sleepwell
Pillow with Cover Model Adore Make sleepwell or Equivalent of Kurl-on
Chair CBA steel with arms Drg No. FD-75(M)
Charpoy Hard top steel Drg No. FD/MAP-II/01
Table office Clerk Steel Drg No. FD-1004
Chair CBA steel with arms and cushioned seat and back Drg No. TP
Cabinet Filling Model : SKU 56101720SD00525 Make Godrej or Equivalent of Empire safe Co.
Chair Draughstman Drg No. FD-204
Table Draughstman Drg No. FD-303
Chair CB steel with arms Drg No. FD-75(M)
Chair CB steel with Spl Hand Rest Drg No. FD-120
Desk with Dias Drg No. FD-399
Pointer Medium Drg No. FD-1041
Pointer Large Drg No. FD-1041
Pointer Small Drg No. FD-1041
Table 900x600 mm without drawer steel Drg No. FD-1007
Form with Back Drg No. FD-78M
Chair dining Drg No. FD-1105
Table dining 6 pers Drg No. FD-273
Sofa Set 3 Seater Drg No. FD-281
Table dining ORs Steel Drg No. FD-165R
Table 900x600 mm with drawer steel Drg No. FD-1008
Table 600x600 mm Drg No. FD-293
Ladder Aluminium Drg No. FD-1025
Bench work shop Drg No. FD-1024
Trestle Store Room Steel Drg No. FD-1043
Chair barber with adjustable neck rest, Overall approximate size shall be 1050mm high x 550mm wide and 550 mm deep, Chair shall be of trade pattern, with chrome base and chrome arms, the seat and back of the chair shall be made of PU foam duly covered with high quality tapestry cloth, the chair shall have the arrangement of tilt and push back and also fitted with hydraulic mechanism for height adjustment .The chair shall be provided with head rest and foot rest. Make:- JSK,Model-JBC-01 or Techno commercial equivalent approved by GE
Mirror large 1260x450mm duly framed
Form without Back 1900x300x450mm Drg No. FD-1027
Table centre Drg No. FD-274
black board with easel Drg No. FD-1041
Carpet Woolen 4Mtr x3.5 Mtr superior quality (All as per trade pattern/as per sample kept with BSO office. Make to be approved by GE) Drg No. TP
Desk stand lecture steel Drg No. FD-1022
Table conference Make Godrej or Equivalent Empire Safe/Royal Koas Drg No. TP
Receptacle PVC Drg No. FD/E6/MAP/13
TV Trolley Drg No. FD/E6/MAP/4R
Rack Steel 6 Tier Drg No. FD-1038
Rack Rifles INSAS 10 Arms Drg No. CWE BTD-96
Almirah Pigeon Hole Steel Drg No. FD-1031
Box Kit Steel Drg No. FD-98 (M)
Note:-Quantities of materials given on standard drawings are for guidance only. The contractor shall work out the quantities of materials required for each item of BOQ and quote his rate accordingly no claim shall be entertained on account of inaccuracy in the quantities of these materials and workman ship which shall be as specified in particular specifications and as approved. The drawing No's mentioned in BOQ item No 184 to 264 shall form part of tender document which will not be attached with tender document. The tenderers are deemed to be in possession and conversant fully with the drawing shown in standard furniture designs including amendments published by AHQ, Engineer-in -Chief, New Delhi. For reference and guidance the tenderer may study and see these drawings in the any office of Garrison Engineer in MES before quoting their rates. No claim shall be entertained regarding misinterpretation of the drawings at a later stage.
Subtotal
Lump sum price worked out by the tenderer for “ARBORICULTURE WORKS" as listed in Schedule ‘A’ Section - XV (Part-I)
Schedule 'A' Section -XV (Part-II) (ARBORICULTURE WORKS INCLUDING ITS MAINTENANCE)
CASECADE GLASS WALL FOUNTAIN Detailed Specification: It comes with 4 LED waterproof Lights of 18 Watt and LED Strip lights and 1500 watt submersible motor pump. Color can be customsed. This fountain has 8MM Glass work along with 20 water nosles for fall. This will also have natural stone and one artificial tree one side incl necessary arrangement of earthwork and removal surplus soil to a distance 50m with complete all as specified and directed by Engr-in-charge.
Supply and laying factory made kerb stone of size 30x15x45cm of M-25 grade cement concrete laid in position to the required line, level and curvature, jointed with cement mortar (1:3) (1 cement:3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete all as specified and as directed by Engineer-in-Charge
Supplying following plants of 0.25 m to 0.30m height including digging holes 1.20m dia x1.2m deep in ordinary soil and refilling the same with the excavated earth mixed with manure of approved quality or sludge in ratio 3:1 (One part of manure & 3 part of soil) manure 200 gm per plant ,flooding with water and removal of surplus soil n.exc 1.50 Km and depositing where directed with & including using suitable chemicals or pesticides of approved quality, as required and making Thaola all as specified and as directed by Engineer-in-charge. Note :- Contractor shall maintain the trees till physical completion of contract.Unit rate quoted is inclusive of replacement of dead trees,manures and all fertilizers mentioned above is inclusive in rate quoted.
Ashoka
Oriented Thuja
Horse Cassia
Gulmohar
Neem Tree.
Kennow
Jamun
Mango
Supply and Installation of LED 10W Bollard light with ,IP 65 protection pressure die cast powder coated housing with all necessary acessories required for fixing as directed by Engr-in charge (make:jaquar cat ref no. LBLDCON010XW or equivalent.)
Material and Labour for making the hole under road and hard standing for laying of pipe upto 40mm dia as required at site by manual drill or Auger system and makig the surface good as per existing surface completed all as specified and directed by Engr-in -Charge.
Supply and fixing thermoplastic (polystreen) junction box having IP 66 protection of size 130x 180x77mm fixed to pole/wall with MS strip nuts bolts , terminal of same company /make having provision of 3 phase aluminium bus bar with & including MCB 6 Amp SPN ,C- curve complete and all as directed by Engr-in-charge.
Supply & fixing rotational moulded polyethylene water storage tank of capacity 500 litres (cylindrical vertical, double layered with closed top), hoisted and fixed in position including inlet and out let connection complete all as specified and as directed.
S&F for Y type Strainer size 25 mm ,small resistance drip system pressure regulator complete all as specified and as directed by Engineer-in-charge
S&F for 3 layer PPR perforated pipe suitable for drip irrigation hole at a distance of 45 cm with end cap as required at site including supply all PPR plain & brass threaded polypropylene random fittings required for size 16mm dia with complete all as specified and as directed by Engineer-in-charge
S&F for water fountain Nozzle Jet sprinkler of size 20mm with complete fixing accessories etc. complete all as specified and as directed by Engineer-in-charge
S&F for 3 watt outdoor LED IP 65 waterproof wall lamp distance Spot light ,warm white Aluminium body complete all as specified and as directed by Engineer-in-charge
Complete maintenance of plant/hedge grass by weeding, hosing, watering, saucer making once in 15 days (every month in alternate day ) for plant/ hedge, insect and pest management (as and when required ), as directed by Engineer-in-Charge pruning new plants in place of dead plants of same species and height tuning with out extra cost to the department complete all as specified and as directed by Engineer -in-charge. (Note Manure & pesticide required for maintenance of plant under this item shall be arranged by the contractor at his own cost and cost of the same shall be deemed to included in the rate quoted against this item)
Subtotal
Schedule 'A' Section -XVI (Maintenance Works for three years after defect liability period)
Materials and labour for applying one coat of synthetic enamel paint over old WPC painted surface complete all as specified and as directed by Engineer -in-Charge.
Supply only 4mm thick sheet glass ordinary quality and glazing with rubber packing around the glass, in squares n. exc 0.5 Sqm in each pane complete all as specified and as directed by Engineer-in-charge.
Supply only 4mm thick figured glass ordinary quality and glazing with rubber packing around the glass, in squares n. exc 0.5 Sqm in each pane complete all as specified and as directed by Engineer-in-charge.
Supply and Fix in repairs aluminium alloy wire mesh 0.45mm nominal dia of wire and average width of apeture 1.4mm fixed with aluminium wire staples etc.complete all as specified and as directed by Engineer-in-charge.
Supply and fix sheet glass ordinary quality and glazing with oil putty /wdn beads in square n.exc.0.50sqm in each pane 4.8 mm thick plain glass on new or old windows incl hacking out old complete all as specified and directed by Engineer-in-Charge.
Supply and fix Figured glass, pin headed type ordinary quality and glazing with oil putty /wdn beads in square n.exc.0.50sqm in each pane 4 mm thick plain glass on new or old windows incl hacking out old complete all as specified and directed by Engineer-in-Charge.
Supply and fix Butt hinges, 100mm length B-21 type extruded stainless steel with galvanised mild steel hinge pin, anodised and fixed , complete all as specified and directed by Engineer-in-Charge.
Supply and fix Butt hinges, 75mm length C-22 type extruded stainless steel with galvanised mild steel hinge pin, anodised and fixed , complete all as specified and directed by Engineer-in-Charge.
Supply and fix 300mm aluminium alloy, anodised, sliding door bolt with hasp & staple (Bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section of cast aluminium alloy complete all as specified and as directed by Engineer -in-Charge.
Supply and fix 150mm long aluminium, anodised barrel tower bolt of extruded section, complete all as specified and as directed by Engineer -in-Charge.
Supply and fix 100mm long aluminium, anodised barrel tower bolt of extruded section, complete all as specified and as directed by Engineer -in-Charge.
Supply and fix 150mm size handle extruded aluminium alloy anodised, fabricated type, complete all as specified and as directed by Engineer -in-Charge.
Supply and fix 100mm size handle extruded aluminium alloy anodised, fabricated type, complete all as specified and as directed by Engineer -in-Charge.
Supply and fix decorative/fancy designer SS drapery rod 20 to 25mm dia fixing to wall with suitable brackets etc complete all as specifed and directed.
Supply and fix decorative/fancy designer SS brackets suitable for decarative draphery rods 20 to 25mm dia etc complete all as specified and as directed.
Taking down cement plaster of any description incl raking out joints, hacking for key, scrubbing down with water, etc all as specified and as directed by Engineer-in-Charge.
Demolition of cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level)as in plinth protection etc complete all as specified and as directed by Engineer -in-Charge.
Materials and labour for 100mm thick Plain cement concrete (1:3:6) type C2 using 40mm graded stone aggregate as in plinth protection, pavings, laid in panels and finishing fair and even, including necessary form work complete all as specified and as directed by Engineer -in-Charge.
Disconnecting of existing tank of capacity 500 ltr and setting aside or lowering if required for repairs cleaning etc and refixing in position hoisting and connecting , complete all as specified and as directed by Engineer -in-Charge.
Materials and labour for painting with one coats of acrylic emulsion paint with 3mm thick wall putty of internal walls including nesessary preparation of surfaces complete all as specificed and as per directed by Engineer-in-Charge.
M& L for one coat of wheather proof exterior acrylic emulsion paint with anti fungal property wall surfaces etc complete all as specified and as directed by Engineer-in-Charge.(Make Apex Ultima)
Supply and fix as in repairs butt hinges, 100mm length B-21 type extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed , complete all as specified and directed by Engineer-in-Charge.
Supply and fix as in repairs butt hinges, 75mm length B-12 type extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed , complete all as specified and directed by Engineer-in-Charge.
Supply and fix as in repairs 300mm aluminium alloy, anodised, sliding door bolt with hasp & staple (Bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section of cast aluminium alloy complete all as specified and as directed by Engineer -in-Charge.
Supply and fix as in repairs 150mm long aluminium, anodised barrel tower bolt of extruded section, complete all as specified and as directed by Engineer -in-Charge.
Supply and fix as in repairs 100mm long aluminium, anodised barrel tower bolt of extruded section, complete all as specified and as directed by Engineer -in-Charge.
Supply and fix as in repairs 150mm size handle extruded aluminium alloy anodised, fabricated type,complete all as specified and as directed by Engineer -in-Charge.
Supply and fix as in repairs 100mm size handle extruded aluminium alloy anodised, fabricated type, complete all as specified and as directed by Engineer -in-Charge.
Supply & Fix in repairs 140mm long door stopper of aluminium alloy body and tounge, anodised with hard drawn steel spring fixed in floor complete all as specified and as directed by Engineer -in-Charge.
Supply and fixed in repair rotational moulded polythelene water storage tanks ISI marked (cylindrical vertical with closed top) of 500 Ltrs capacity with tank cover (top), hoisted and fixed in position, including taking down existing with all connections complete all as specified and as directed by Engineer -in-Charge.
Supply and fix rotational moulded polythelene water storage tanks ISI marked (cylindrical vertical with closed top) of 1000 Ltrs capacity with tank cover (top), hoisted and fixed in position, including taking down existing with all connections complete all as specified and as directed by Engineer -in-Charge.
Supply and fix 20mm dia nipple of PTMT, suitable for HDPE water tank, min weight 38 gms, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix 25 mm dia nipple of PTMT, suitable for HDPE water tank, min weight 65 gms, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs 20mm dia nipple of PTMT, suitable for HDPE water tank, min weight 38 gms, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs 25mm dia nipple of PTMT, suitable for HDPE water tank, min weight 65 gms, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs 20mm dia ball valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed, minimum weight 142 gms,complete all as specified and directed by Engineer-in-Charge
Supply and fix in repairs gun metal globe or gate valve, 20mm dia, screwed down high pressure with iron wheel head, screwed both ends for iron pipes or for union complete all as specified and as directed by Engineer-in-Charge
Taking up or down, 20mm dia bore, CPVC/UPVC pipe, medium grade, including removal from site, complete all as specified and as directed by Engineer-in-Charge.
Taking up or down, 25mm dia bore, CPVC/UPVC pipe, medium grade, including removal from site, complete all as specified and as directed by Engineer-in-Charge.
Supplying and laying CPVC pipes of 25mm outer dia SDR 11 & plain CPVC SDR 11 fittings on walls / ceilings or laying in floors complete all as specified
Supplying and laying CPVC pipes of 20mm outer dia SDR 11 & plain CPVC SDR 11 fittings on walls / ceilings or laying in floors complete all as specified
Dismantling of floor, hearth or wall tilling incl cement mortar bedding (but not backing) and removing the rubbish off the premises complete all as specified and as directed by Engineer -in-Charge.
Materials and labour for coloured non skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exc 0.06 sqm n.exc 0.11 sqm, in floors etc set and jointed in neat cement slurry in floors and pointed with coloured cement to match the colour of tiles incl screed bed or bedding layer of mortar 10mm thick in CM 1:4 for laying floor finishes complete all as specified and as directed by Engineer -in-Charge.
Materials and labour for coloured non skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exc 0.11 sqm n.exc 0.18 sqm, in floors etc set and jointed in neat cement slurry in floors and pointed with coloured cement to match the colour of tiles incl screed bed or bedding layer of mortar 15mm thick in CM 1:6 for laying floor finishes complete all as specified and as directed by Engineer -in-Charge.
Materials and labour for coloured glazed ceramic tiles 450 X 300 X 7mm thick as in dado/skirting set and jointed in neat cement slurry and pointed with coloured cement to match the colour of tiles over and including rendering 10mm thick in CM 1:3 on wall surfaces complete all as specified and as directed.
Materials and labour 18-20mm thick granite stone (of any type and coloured in single peice ) work (table rubbed and polished) in steps, jambs, pillars, window cills, flooring, cooking platform machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite including griding and polishing and rounding on edges types over & including screed bed 20mm thick in CM 1:4 complete all as specified and directed by Engineer-in-Charge.
Material & labour for 80mm thick factory made coloured interlocking cement concrete tile with grage of M-40 confirming to IS 15658-2006 manufactured by hydraulic pressure process with gray cement and no pigment laid over sand complete all as specified and directed. Sand for cushing shall be measured and paid separately
M&L sand cushing filling under floor path incl watering and consolidation complete all as specified and as directed
Supply and fix in repairs Brass Chromium plated tubular towel rail, 20mm dia, D type, 60cm long, between flanges including suitable bracket complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs viterous China wash down wall mounted water closet pan with superior quality, health faucet and incl connection to drain or out going pipe and concealed flushing pipe cistern and flushing pipe etc and incl plastic seat cover white anodised hinging device incl fixing bolt and taing out old EWC with flushing cistern complete all as specified and as directed by Engineer-in-Charge
Supply and fix in repair 32mm brass chromium plated bottle trap for wash basin with inlet and outlet screwed for pipe or connection including necessary packing union and cap complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs stainless steel gratings 125mm dia, complete all as specified and as directed by Engineer-in-Charge
Supply and fix in repairs vitreous China wash hand basin of size 550 x 400mm white flat back including chromium plated pillat tap, 32mm Waste coupling of PTMT (half or full threaded) (Minimum weight 32mm-45gms/40mm-60 gms), including brackets, PVC waste pipe, including cutting for and pinning in ends of brackets or errecting stand, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair stop valve, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screw both ends for 15mm dia iron pipe or for union and fixed complete all as specified and as directed by Engineer -in-Charge.
Supply and fix in repairs 15mm size PVC Connection with C P Brass Nuts of length 450mm, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair 15mm bore pillar tap, cast copper alloy with capstan heads, chromium plated screwed down, high pressure, with or without lettered hot or cold with long screwed shanks and fly nuts screwed for iron pipes complete all as specified and as directed by Engineer-in-Charge
Supply and fix in repairs chromium plated, stainless steel towel rings,200mm dia complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs chromium plated hand shower (health faucet) 1 meter, with PVC tube with wall hook ,complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs brass chromium plated toilet paper holder recessed type, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs 15mm bore stop valves fancy type chromium plated with long shank and cup, concealed type , complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs vitreous China urinal, bowl type complete including providing and fixing plugs, bedding urinal against wall in cement morter 1:2 securing urinal to plugs with and including 60mm long brass screws pointing around urinal back in cement etc, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs two way bib cock, brass CP mixture for mixing hot & cold water complete all as specified and as directed by Engineer-in-Charge
Supply and fix in repair PVC waste pipe, 32mm/40mm dia, for WHB, Sink & urinal, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs long body Bib tap, cast copper alloy chromium plated,15 mm dia with fancy type screwed down for iron pipes or brass ferule etc, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs sink with drainage board, made up of stainless steel, 1mm thick for kitchen or laboratory with plug washers and waste fittings, including bedding in cement mortar 1:3 into dwarf wall or cantilever brackets and connecting union to pipe, over all size 915mm x 460mm, bowl size 410 x 330 x 160mm etc, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs Plastic water closet seat cover complete all as specified and as directed by Engineer -in-Charge.
Supply and fix in repair Shower arm 15 mm size, 195mm long with bend of 45degree with flange of PTMT any colour.(Minimum weight 40gms) complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs Brass Chromium plated shower rose 125mm size, with swivel joint, fixing to steel pipe or union, complete all as specified and as directed by Engineer-in-Charge.
Demolition of AAC block walling, built in cement mortar including all quoins, arches, pillars, etc
Materials and labour for AAC block masonry solid blocks and set in CM1:6 complete all as specified and directed
M&L for PVC (SWR) pipes 110mm bore double socketed in any length with rubber ring joints, fixed to wall incl testing of pipe etc complete all as specified and directed by Engr-in-Charge
M&L for PVC (SWR) pipes 75mm bore double socketed in any length with rubber ring joints, fixed to wall incl testing of pipe etc complete all as specified and directed by Engr-in-Charge
M&L for PVC (SWR) floor trap, plain with grating including jointing with solvent cement 75mm outer dia, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4)
Supply and fix PVC (SWR) bends 110mm bore with oval access doors all as specified and directed.
Supply and fix PVC (SWR) bends 75mm bore with oval access doors all as specified and directed.
Supply and fix PVC (SWR) junction single, (Single T) 110mm bore, equal or unequal with oval access doors all as specified and directed.
Supply and fix PVC (SWR) junction single, (Single T) 75mm bore, equal or unequal with oval access doors all as specified and directed.
Supply and fix PVC (SWR) branch piece, single (single Y) equal or unequal110mm bore, equal or unequal with oval access doors all as specified and directed.
Supply and fix PVC (SWR) branch piece, single (single Y) equal or unequal 75mm bore, equal or unequal with oval access doors all as specified and directed.
Material and labour for Cleaning/removal of blockage from Bathroom, Kitchen, WHB ,EWC, IWC, Urinals etc. including connected Nahani traps / gully traps/floor traps, grating of trap, waste pipes, pipe in any length upto Ist manhole etc choked with mud / other accumulated sludge and getting out, washing thoroughly at any location, at any floor by rodding/choke remover/Pressure technique/manually or otherwise to clear blockage upto entire satisfaction of users, including refixing of oval assess door covers with new nuts & washers and refixing manhole covers, including removing of all wastes, solid or liquid sludge and depositing the sludge in a pit (at empty/open area) of suitable size at a distance exceeding 50 metres from the building where directed and covering the same with the soil obtained from excavation of pit after treating the sludge by spreading the bleaching powder as directed to reduce the foul gases including all excavations and earthwork complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Cleaning of existing sewage system/pipe line 100/150/200mm dia (length of pipe line manhole to manhole not exceeding 20 mtr) including cleaning of manholes (any type rectangular/square/circular) located in different situations/sites, taking off the manhole cover (CI or RCC) and placing in the same original position after getting out liquid/sludge/solid contents from the manholes/sewage line and complete perfect function/running/flowing condition without any obstruction by removing all blockage in system with manual labour (rodding manually) or by mechanically sewage suction pump (at contractor;s discretion as required at site) making it fully functional to the entire satisfaction of Engineer-in-charge including removing of all wastes, solid or liquid sludge through closed container and depositing the sludge in a pit (at empty/open area) of suitable size at any distance upto 200 metres from the line/colony area where directed and covering the same with the soil obtained from excavation of pit after treating the sludge by spreading the bleaching powder as directed to reduce the foul gases including all excavations and earthwork complete all as specified and as directed by Engineer-in-Charge. Note for item No 01 to 02 :- (i) Contractor or his representative shall report daily at 09.00 AM except on Sunday/ National holidays in the office of Engineer-in-Charge/ Complaint cell to receive complaint slip and necessary directions. Complaints received through telephonic message from JE/ Engineer-in-Charge shall also be attended on the same day and the completion of work shall be reported by 05.00 PM of every working day to JE/ Engineer-in-Charge. (ii) In case of non attandence of complaints against BOQ item 01 and 02 above by the contractor on the same day, a penalty of Rs 200/- per complaint per day shall be recovered from the contractor's dues. (iii) The cost for all necessary T&P such as green female bamboo strips, iron rods, sewage rodding machine, buckets, rope, ladder, safety mask, bleaching powder etc and all other materials for execution of the work shall be included in the unit rate. (iv) A complaint register shall be maintained by JE and proper record of complaints received and attended with date and time shall be recorded and shall be signed daily by both the parties. Complaint register shall be kept on record of Engineer-in-Charge after completion of work.
Cleaning and desilting of sewage lines 150 mm to 250 mm dia of any size at any depth by pumping out /removing liquid waste/sewage ,plugging the ends pipes or diverting the flow into drains if necessary, removing silt, sludge etc, sprinkling bleaching powder on the silt to avoid bad smell including all precautionary and safety measures, such as safety belts, lighting arrangements face mask etc and removing the same(silt,sludge &other waste material) in leak proof trucks covered with tarpoline all as per existing rules and regulations of civil authorities and flushing the sewer lines with fresh water etc complete all as specified and directed by Engr-in-Charge. Note :- (a) If required getting a honey sucker and cleaning the heavily congested sewage line. (b) JCB and other machinery required on special basis would be called on requirement basis.
Cleaning and desilting of manholes depth not exceeding 1.50 meter by pumping out/removing liquid waste/sewage and plugging the ends of sewer pipes or diverting the flow into drains if necessary, removing silt, sludge etc, sprinking bleaching powder on the silt to avoid bad smell including all precautionary and safety measures, such as safety belts, lighting arrangements face mask etc and removing the same(silt,sludge &other waste material) in leak proof trucks covered with tarpoline all as per existing rules and regulations of civil authorities and cleaning the manholes with freah water etc complete all as specified and directed by Engr-in-Charge . Note :- (a) If required getting a honey sucker and cleaning the heavily congested sewage line. (b) JCB and other machinery required on special basis would be called on requirement basis.
Cleaning and desilting of manholes depth exceeding 1.50 m but not exceeding 3.00 m by pumping out/removing liquid waste/sewage and plugging the ends of sewer pipes or diverting the flow into drains if necessary, removing silt, sludge etc, sprinkling bleaching powder on the silt to avoid bad smell including all precautionary and safety measures, such as safety belts, lighting arrangements face mask etc and removing the same(silt,sludge &other waste material) in leak proof trucks covered with tarpoline all as per existing rules & regulations of civil authorities and cleaning the manholes with freah water etc complete all as specified and directed by Engr-in-Charge. Note :- (a) If required getting a honey sucker and cleaning the heavily congested sewage line. (b) JCB and other machinery required on special basis would be called on requirement basis.
Taking down carefully existing copper/aluminium point wiring (light/fan/socket/bell/power point) complete with all accessories such as switch, socket with sheet, ceiling rose, lamp holder inclding rusted/broken concealed conduit, junction boxes etc and removing dismantled material and making good disturbed surfaces of wall/floor etc matching with existing surface complete all as specified and as directed by Engineer-in-charge.
Material and labour for concealed Point wiring for one light point/fan point controlled by one switch (using red, black and green colour wires as colour coding) complete with 1.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (Min 50mm deep and 1.6mm thick sheet, suitable size) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches/ regulator etc, including provn of 1.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) including fixing of switch/socket/regulator etc complete all as specified and as directed. (switch,socket, regulator shall be measured and paid separately under appropriate items of sch as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ).
All as per above Srl item No. 393.00 but for one socket out let 5 Amps point controlled by one switch (on same board) complete all as specified and as directed by Engineer-in-charge.(switch, socket shall be measured and paid separately under appropriate item of Sch as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ).
All as per above Srl item No. 393.00 but for one socket out let 5 Amps point controlled by one switch (on independent board and not below the any other switch board) complete all as specified and as directed by Engineer-in-charge. (switch, socket shall be measured and paid separately under appropriate item of sch as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ).
Material and labour for concealed Point wiring for one socket out let 15/16 Amps point controlled by one switch (on independant board) (using red, black and green colour wires as colour coding) complete with 2.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (Min 50mm deep and 1.6mm thick sheet, suitable size ) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches / socket, including provn of 2.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3), including fixing of switch, socket complete all as specified and as directed. (switch, socket shall be measured and paid separately under appropriate item of sch as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate).
Supply only modular switch 6Amps, single pole, one way (1 module) complete all as specified and as directed by Engineer-in-charge.
Supply only modular switch 16Amps, single pole, one way (1 module) complete all as specified and as directed by Engineer-in-charge.
Supply only modular Socket outlet multipurpose type 6 Amp, flush type (2 module) complete all as specified and as directed by Engineer-in-charge.
Supply and fixing Ceiling Rose, polycarbonate, isolated body, surface bakelite 3 terminal, 240 volts, 5/6 Amp complete all as specified and as directed.
Supply and fix fan step regulator 120 w-2 Moudule complete all as specified.
M&L for taking down unseviceable ceiling fan of 1200mm sweep and rewinding with copper winding wire as per existing size and gauge, including replacement of capacitor, bearings, rubber reel, greesing etc complete all as specified and as directed by Engineer-in-charge. Note: any minor spare required for making the fan serviceable shall deemed to be included in the quoted cost.
Supply and fixing ventilating air fresh fan, AC single Phase 230V, 50Hz, 1200RPM, size 250mm sweep, copper winding, made of sturdy engineering plastic complete with louvers shutters including making suitable opening arrangement in wall and electric connection with and including three core PVC Insulated PVC Sheathed copper conductor flexible cable 24/0.2mm drawn in flexible PVC conduit and hanging on wall with 4 Nos steel fastners 10mm dia 100mm long and making good the disturbed surface complete all as specified and as directed by Engineer-in-charge. Note:- (i) Serial No as issued by Engineer-in-charge of fan shall also be written on the fan with red colour permanent marker, cost of the same shall deemed to be included in quoted cost. (ii) Cost of making hole in wall for fixing of exhaust fan shall deemed to be included in quoted cost. NOTE (i) Old/unservicable Ceiling Fan/Exhaust fan shall be deposited to AGE E/M yard of GE(S) Bathinda.
Supply and fixing LED tube light fitting polycarbonate housing 1 x 20 Watt, appx 4 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge
Supply and fixing LED tube light fitting polycarbonate housing 1 x 10 Watt, appx 2 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
Supply and fixing surface mounted complete fitting with separate electronic driver and high brightness LED 34/36 Watt flat panel of size 600x600mm, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to light fitting, complete fitting and all accessories including fixing material with following specifications and all as directed
Material and labour for concealed sub main wiring (using colour coding such as red, black, white, green colour or as directed) with 4 Sqmm single core (03 run i.e 2 runs for main phase and neutral, 01 run for continues as earth wire) FRLSH PVC insulated unsheathed multistrand copper conductor cable drawn through and including PVC conduit 25mm dia (medium quality ISI marked), for independent circuit including all fitting arrangement i.e. PVC clamp, rawl plug, screw, PVC junction box, tee, bend etc. and including cutting of chases in wall and making good disturbed surfaces of walls as per original complete all as specified and as directed.Note :- Three runs of copper conductor cable and one run of PVC conduit including accessories shall be measured and paid as one unit (one RM length) for payment and extra length of cables required for connection to MCBs/DB shall not be measured and the cost for the same shall deemed to be included in the unit rate.
supply and fixing (concealed in wall or as directed ) single pole and neutral sheet metal enclouser (AC Box) with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amps, 240 Volts ,AC supply complete all as specified and directed by engg-in -Charge.
Supply and fixing (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 200 Amp rated bus bar) TPN, 4 Way 415V, suitable for mounting MCB/Isolator etc, conforming to IS-13032, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-43 protection class, and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge. Note :- MCB/Isolator etc shall be measured and paid separately under appropriate item of BOQ.
All as per item srl No 410 above but with TPN 4 way vertical DB including MCCB 4pole 160 Amp.
S&F Sheet metal encloures for DB's, metallic double door, SPN, 12 way, 415 volt with 200 amp rated bus bar, IP-43 protection, vertical type having housing for fixing MCCB complete all as specified.
S&F Sheet metal encloures for DB's, metallic double door, SPN, 8 way, 415 volt with 200 amp rated bus bar, IP-43 protection, vertical type having housing for fixing MCCB complete all as specified. NOTE FOR ITEM 412 to 413: (i) DB shall be fixed flush to wall with cement mortar (1:4) on location approved by Engineer-in-charge. (ii) MCCBs/MCB shall be measured & paid under respective item of BoQ.
Supply and fixing RCBO for earth fault leakage, over load and short circuit protection 10KA suitable for 230V AC supply. 25-32 Amps, 30mA, double pole complete.
Supply and fixing MCB ‘C’ curve suitable for 415 volts AC supply, 16 to 32 Amps, TPN with over load and short circuit protection and rupturing capacity not less than 10 KA, fixing in DB complete all as specified and as directed by Engineer-in-charge
Supply and fixing MCB ‘C’ curve suitable for 240 volts AC supply, 05 to 32 Amps, SP with over load and short circuit protection and rupturing capacity not less than 10 KA, fixing in DB complete all as specified and as directed by Engineer-in-charge
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI earthing wire 4 mm dia by means of GI bolts/nuts/washers and protected by 15 mm bore GI light grade pipe upto test point or upto main switch board, fixing with 02 Nos nuts and bolts. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common salt all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50m, Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) including taking out/dismantling old unserviceable earthing system complete all as specified and as directed by Engineer-in-charge. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing wire upto test point or upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.
Subtotal
VIJAY JINDAL BUILDERS PVT LTD (BID ID -3249024)
M/s DMR Builders Pvt Ltd (BID ID -3248093)
ENGINEER CONSTRUCTION PVT. LTD. (BID ID -3252538)
M/s Aadhar Stumbh Infra Pvt Ltd (BID ID -3243393)
NAND LAL PURI AND SONS PRIVATE LIMITED (BID ID -3258405)
Aalaya Engineering Project Private Limited (BID ID -3244957)
SOOD ASSOCIATES PVT LTD (BID ID -3249200)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid