Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹62.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | Rejected-Technical | - | Rejected-Technical Non-responsive to the requirements of bid documents | |
| 3 | Rejected-Technical 22 STRAND ROAD KOLKATA 700001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | - | Rejected-Technical Non-responsive to the requirements of bid documents |
Tender Value
₹63.2 L
EMD Value
₹1.3 L
Closing Date
9 Dec 2022, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CGM(OnM), LAR
O/o The CGM, OnM(LAR),Bijulee Bhawan, Paltan Bazar
Construction of new tower and associated work in place of river eroded tower at Loc-96 of 132 KV Dhaligaon- APM Line
2022_AEGCL_27302_2
TL-252/Bongaigaon/TnT/2021/Bid
Open Tender
Electrical Works
Works
180 days
Nayagaon
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
₹1.3 L
Yes
2 May 2023
11 Nov 2022
12 Dec 2022
11 Nov 2022
9 Dec 2022
12 Nov 2022
11 Nov 2022 - 18 Nov 2022
Amount
Tower Superstructure
Galvanised Lattice steel tower super structure [including hangers, gussets, strain plate (Approximate HT Steel = 28%, MS=72%) B+0 (1 Nos)
Stub Sets
Partially galvanised Stub angle with cleat (Approximate HT Steel =95%, MS=5%)
Stub setting template
Stub setting template
Nuts and bolts
Galvanised Nuts and Bolts
Groundwire
G.I. Ground Wire
Strain Clamp
Suspension clamp
Copper Earth Bond
Insulators
Porcelain Disc Insulator, 120 KN
Power Conductor Accessories
Single Tension Hardware fittings suitable for ACSR Panther Conductor including all accessories.
Mid Span Joint
Vibration Damper suitable for ACSR Panther conductor
Repair Sleeve
Tower Accessories
Danger Plate
Phase Plate
Number Plate
Bird Guard
Anti-Climbing Device
Power Conductor
ACSR Panther Conductor
Description of Work / Item(s)
Amount
Tower Superstructure (F&I)
Galvanised Lattice steel tower super structure [including hangers, gussets, strain plate (Approximate HT Steel = 28%, MS=72%) B+0 (1 Nos)
Stub Sets (F&I)
Partially galvanised Stub angle with cleat (Approximate HT Steel =95%, MS=5%)
Stub setting template (F&I)
Stub setting template
Nuts and bolts (F&I)
Galvanised Nuts and Bolts
Groundwire (F&I)
G.I. Ground Wire
Strain Clamp
Suspension clamp
Copper Earth Bond
Insulators (F&I)
Porcelain Disc Insulator, 120 KN
Power Conductor Accessories (F&I)
Single Tension Hardware fittings suitable for ACSR Panther Conductor including all accessories.
Mid Span Joint
Vibration Damper suitable for ACSR Panther conductor
Repair Sleeve
Tower Accessories (F&I)
Danger Plate
Phase Plate
Number Plate
Bird Guard
Anti-Climbing Device
Power Conductor (F&I)
ACSR Panther Conductor
Description of Work / Item(s)
Amount
Survey
Detail & Check survey as per specification
Construction of Pile Foundation (B+3)
Mobilization (including preparation of work space, Approach road, dewatering, arrangement of electricity, jungle clearing, earth filling and making all arrangement for completion of the work) and construction and supply of all materials & labours of temporary island/platform to facilitate the construction of foundation including platform for storage of construction materials such as stone chips, sand, cement, steel reinforcement bar, mixture machines, tools & plants all foundation materials keeping & mixing.
Boring, providing and installation of bored cast in situ pile of 1200 mm diameter below the pile Head with M25 grade of cement concrete including the cost of reinforcement steel, cost of boring with temporary quide casting bentonite solution. (Length of the pile for payment shall be measured from the bottom of the pile Head). All necessary labour materials, plants and tackles etc. complete as necessary for proper execution of the job upto 22.00 meter from the bottom of the pile Head. The unit rate include excavation, dewatering, socketing, anchoring (if required), backfilling, form work for placing plain or reinforced concrete cement, supply and providing MS liner of 6 mm thick in piles upto 10-meter depth from the bottom of the ground level. All execution should be as per approved drawing. (Payment will be made as per actual length of the piles as per site condition)
Providing and laying in M25 grade concrete of specified 28 days strength for pile Head, Tie Beam, Chimney including reinforcement steel, form work, scaffolding for all level as per site necessary, all necessary materials and equipments, transportations, batching, mixing, vibration, dewatering etc as per approved drawing and direction. Pile head: 4 X 3.14 X 0.6 X 0.6 X 2 = 9.0432 cum Tie Beam: 4 X 5.5 X 0.4 X 0.6 = 5.28 cum Total= 14.32 cum
Conducting standard penetration test (SPT) at various elevations in pile bore holes in all kind of soils including all labour, materials, tools & tackles, equipments etc. required for successful completion of the job.
Conducting Pile Integrity test on piles using electronic control unit, hand held hammer, accelerometer, computer with required software to assess as-installed pile characteristics including mobilisation of necessary manpower, equipments, materials etc. required for successful completion of the job.
Stub setting
Setting of stubs (Sets of four) including transportation & distribution of stub and accessories from store to site excluding cost of excavation, concreting & back filling.
Erection of superstructure
Superstructure erection including transportation of structures by any means and distribution of structure and accessories from store to site
Welding of all nuts & bolts up to the bottom cross arm level including all charges of transportation, materials etc.
Stringing
Stringing of G.I. Ground wire including transportation and distribution of ground wire and accessories to site and laying, stringing, tensioning , clamping, jointing , complete including all fittings and accessories not specifically mentioned elsewhere per route Km of line
Grounding and other works
Grounding of towers with 3 metre long 25 mm dia G I pipe, including cost of all materials, such as GI pipes, GI bolts & nuts and washer, salt, cock etc as per Specification
Painting of towers with bituminous paints of approved quality up to 3 metres from ground level including the cost of paints.
Erection of Danger plates. (1 no per tower)
Erection of Phase plates (1 set per tower)
Erection of Number plates. (1 no per tower)
Erection of anti-climbing device (1 set per tower)
Erection of Bird Guard (3 nos per tower)
Dismantling
Opening and lowering of ground wire from portion of the line to be dismantled and transportation to store
Dismantling of towers without damaging the members, transportation to the store and proper staking
Description of Work / Item(s)
Amount
Transportation of ERS (To & From)
ERS tower material sorting, loading and carrying from Kahilipara store and unloading at camp site. Weight per ERS= 5.2 MT
ERS tower material sorting, loading and carrying from camp site and unloading at Kahilipara store. Weight per ERS= 5.2 MT
Erection of ERS tower
Carrying of all ERS materials from road side to work site by head loading
Preparation & levelling of site
Anchoring (Including Excavation) of 5 (five) Nos. of Anchor
Erection of ERS tower
Dismantling of conductor (3 Nos) from existing line at location
Stringing of conductor (3 Nos) in 1 No. of ERS tower including all necessary work
Dismantling of ERS
ERS tower materials sorting, loading and carrying from work site to camp by head loading
Dismantling of power conductor (3 Nos) from ERS tower
Stringing of new conductor on new tower (3 Nos)
Dismantling of ERS including De-Anchoring
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .