RequiredExperience with Government
RequiredAnnual Turnover
RequiredCertificate (Requested in ATC)
RequiredOEM Authorization Certificate Bid to RA enabled No Solar Lamps (Solar Based Home Systems - Solar Power Packs - AC Models ) ( 1 pieces ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) GENERIC Solar Photovoltaic lighting systems and power packs A. C. Models shall conform to MNRE specification (Off- Yes * 1/8 grid Solar Applications Scheme 2016-17) Power pack model SPV Module:200 Wp
RequiredBattery:12V
Required150 Ah
RequiredSolar charge controller: 12V
Required20A SPV Module:200 Wp
RequiredBattery:12V
Required150 Ah
RequiredSolar charge controller: 12V
Required20A Solar Inverter: 24V/12 V
Required300VA
RequiredPure Sine wave (THD<5%) Yes * Load 100 Watt load for 6-7 Hours/day for 300 Wp solar power pack * Indicative A.C. Loads: 3 Nos. of White Light Emitting Diode (W-LED) Luminaire (max. 3.0 Watts each ) for 6 Hrs. day Yes. Provided * "Indicative A.C. Loads: 2 Nos. of White Light Emitting Diode (W-LED) Luminaire (max. 6.0 Watts each ) for 6 Hrs. day" Yes. Provided * Provision to Power for One Fan or A TV set for 6-7 Hrs./day for 300 Wp solar power pack * Provision for operating the radio Yes * USB port for mobile Phone Charging Yes * CONSTRUCTIONAL Corrosion resistant frame structure should be provided to hold the SPV module. PV Module shall supply with Module mounting structure Yes * The frame structure should have provision to adjust its angle of inclination to the horizontal
Requiredso that it can be installed at the specified tilt angle Yes * Mounting type of light source as per site requirements. ceiling mounted ceiling mounted A vented plastic wooden/metallic box Yes. provided * 2/8 with acid proof corrosion resistant paint for housing the storage battery indoors should be provided The system should have two indicators
Requiredgreen (charging under preogress) and red (indicate the battery "Load Cut Off" condition) Yes * Working temperature 0 deg C to 45 deg C * PV MODULE Indigenously manufactured PV modules should be used Yes * The PV modules should be made up of crystalline silicon solar cells and must have a certificate of testing conforming to IEC 61215 Edition II/BIS 14286 from an NABL or IECQ accredited Laboratory. Yes * Efficiency for PV Modules >14% * The terminal box on the module should have a provision for opening
Requiredfor replacing the cable
Requiredif required Yes * "There should be a Name Plate fixed inside the module which will give: (a) Name of the Manufacturer or Distinctive Logo. (B) Model Number (c) Serial Number (d) Year of manufacture" Yes * A distinctive serial number starting with NSM will be engraved on the frame of the module or screen printed on the tedlar sheet of the module. Yes * BATTERY The battery should be Lead Acid
RequiredTubular positive plate flooded Yes * 3/8 electrolyte or Gel or VRLA Type. Battery Ah at C/10 rated 75 % of the rated capacity of the battery should be between fully charged & load cut off conditions Yes * Battery should conform to the latest BIS International standards Yes * LIGHT SOURCE The luminaries should use white LEDs Yes * Minimum 18 Lux for 3 W LED Luminaire and Minimum 32 LUX for 16W LED Luminaire when measured from a height of 2.5 meter in an area of 2.5 meter diameter Yes * The colour temperature of White-LED(s) used in the system 5500 deg K to 6500 deg K * 3 Nos. of White Light Emitting Diode (W-LED) Luminaire (max. 3.0 Watts each) . Yes. Provided * 2 Nos. of White Light Emitting Diode (W-LED) Luminaire (max. 6.0 Watts each). Yes. Provided * The total input power consumption by the luminaire is not more than 3 W/6W as applicable (including the LED driver consumption). Yes * White-LED(s) should not emit ultraviolet light Yes * The light output from the White- LED should be constant throughout the operation of lights Yes * The lamps should be housed in an assembly suitable for indoor use with an appropriate heat sink to dissipate the heat generated by Yes * 4/8 LEDs during operation "The temperature of LED should not increase more than 10o above room temperature. This condition should be complied for 5 hours of operation of the lamp at a stretch while battery operating at any voltage between the loads disconnect and the charge regulation set point" Yes * The luminaries must use the optics and diffuser in order to have uniform and glaze free light Yes * The make
Requiredmodel number
Requiredcountry of origin and technical characteristics (including IESNA LM-80 report) of white LEDs used in the lighting system must be furnished to the buyer consignee along with the system Yes * All Luminaries should have a built in ON/OFF switch and fuse Yes * ELECTRONICS Electronics should operate at 12/24 V and should have adequate temperature compensation arrangement for proper charging of the battery throughout the year Yes * Total Harmonic Distortion <5% * Inverter efficiency >/=90% * The system should have separate ports for connecting each load along with a charging port for mobile and laptop Yes * The voltage drop from module terminals to Yes * 5/8 the battery terminals should not exceed 1.0 volts including the dropage across the diode and the cable when measured at maximum charging current The idle current i.e. when there is no load (& inverter is switched OFF
Requiredin case of A.C. Systems) and no display </=150 mA * The PCB containing the electronics should be capable of solder free installation and replacement Yes * Necessary lengths of wires/cables
Requiredswitches suitable for DC use and fuses should be provided Yes * Necessary lengths of wires/cables
Requiredswitches and fuses should be provided Yes * The inverter output AC voltage should not change with the decreased battery voltage in the operating voltage range of the battery Yes * No Load protection Yes * Battery over charge and deep discharge protection Yes * The load reconnect should be provided at 90% of the battery capacity status Yes * Battery reverse polarity
RequiredShort circuit proection
Requiredreverse flow currect protection Yes * WARRANTY Warranty for Solar home system including Battery from the date of supply 5 Years * 6/8 Warranty for PV Modules from the date of supply as per MNRE specn.
Required>/=25 Years * PV modules used in Solar Home Lighting System must be warranted for their output peak watt capacity
Requiredwhich should not be less than 90% at the end of Ten (10) years and 80% at the end of Twenty five (25) years Yes * The Warranty Card to be supplied with the system must contain the details of the system. The manufacturers can also provide additional information about the system and conditions of warranty as necessary Yes * OPERATION and MAINTENANCE MANUAL shall be furnish to the buyer/consignee as per MNRE (Off-grid Solar Applications Scheme 2016-17) (including IESNA LM-80 report of W-LEDs) Yes * CERTIFICATION Availability of Type Test Report from Central Govt./NABL/ILAC accredited lab to prove conformity to specification Yes * Storage battery shall comply with Bureau of Indian Standards of CRS as on date as applicable Yes * PV Modules shall comply with Bureau of Indian Standards of CRS as on date as applicable Yes * * Specifications highlighted in bold are the Golden Parameters. * Bidders may note that In respect of non-golden Parameters
Requiredthe specifications 'Values' chosen by 7/8 Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer. Additional Specification Documents