AGE (I) Fatehgarh
AGE (I) Fatehgarh
SPECIAL REPAIR TO 02 X BATHROOM AND TOILET BLOCKS AT SITE-III, RAJPUT REGT CENTRE (BLDG NO- 06/B AND 09/B)
2025_MES_703599_2
AGE(I)/FAT/ET-76 OF 2024-2025
Open Tender
Miscellaneous Works
Works
180 days
AGE (I) Fatehgarh
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
AGE (I) Fatehgarh
₹20,000
Yes
7 Jul 2025
16 May 2025
16 Jun 2025
16 May 2025
10 Jun 2025
16 May 2025
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (including taking down of backing plaster to brick / concrete wall surface), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Demolition of cement concrete in ground floors and paving n exc 15 cm thickness (below or above ground level) complete all as specified.
M & L 25 mm thk cement conc. Type B-0 1:2:4 (12.5mm graded crushed stone aggregate) as in sub base to floor complete.
M&L for Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match , laid over & including 15mm thick cement screed bed or bedding layer in CM 1:6, etc. complete all as specified and directed by Engr-in-Charge.
M&L Glazed ceramic tiles in vertical surface 350x250mmx7mm/450X350X7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles over 10 mm thick screed in cement mortar (1:4) on vertical surfaces of walls as skirting/ dados etc complete all as specified and directed .
Taking up or down steel tubing and connections,20mm dia complete all as specified and directed .
Taking up or down steel tubing and connections,15mm dia, complete all as specified and directed.
S&F GI tubes medium grade with all fitting (such as bends, elbow, tees, connectors, caps, plugs, unions etc.) fixed to wall and ceilling or laid in floor of 15 mm bore of pipe complete all as specified and directed.
S&F GI tubes medium grade with all fitting(such as bends, elbow, tees, connectors, caps, plugs, unions etc.) fixed to wall and ceilling or laid in floor of 20 mm bore of pipe complete all as specified and directed.
S & F in repair bib tap fancy type cast copper alloy chromium plated with crutch or butterfly handle screwed down screwed for iron pipe or brass ferrule or fixed for 15 mm dia pipe complete all as specified and as directed.
S & F in repairs vitreous china squatting pan orissa pattern long pan size 580 mm x 440 mm white with spun pipe ‘P’ or ‘S’ trap including lead joint and CI spun branch piece , front or back inlet and foot rests excluding flushing cistern & flush pipe but incl. cement concrete bedding fixed complete all as specified and as directed.
S&F in repair low level flushing systern PVC valveless syphonic action type 10 ltr capacity complete all as specified and directed by Engr in Charge
M&L for two coats of synthetic enamel paint over a coat of red oxide primer on new steel surfaces of any description over 10cm in width or girth not otherwise described including preparation of surfaces, complete all as specified and directed
S&F 4.8mm thick, sheet glass ordinary quality and glazing with oil putty in square n exc 0.50 Sqm in each pane.
S&F in repair CP Stop valves angle, fancy type , screwed down for iron pipe and fixed to 15mm bore pipe , complete all as specified and directed.
S&F in repair PVC connection 450 mm long with PTMT nuts at both end suitable for 15 mm bore pipe complete all as specified and directed.
S&F 75 mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified.
Taking down chowkats or frame with shutters ( without taking off shutter from frame ) n exc 1.50Sqm each cement complete all as specified.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm double side prelam PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening as per specification & drawing complete all as specified.
Factory made solid panel pvc door shutter 30mm thick (style) consisting of rame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined to gether with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed.
S&F 150 mm, long, Aluminium anodised, barrel tower bolt of extruded section and fixed.
S&F 150 mm long , extruded aluminium alloy handles fabricated type anodised and fixed.
S&F 100 mm Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed.
Taking down cement plaster from brick or stone walls etc. including raking out joints hacking for key scrubbing down with water etc. complete all as specified and directed.
M&L for Rendering 15mm thick on brick work or concrete surfaces in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed.
M&L for 15 mm thick rendering in two layer (10+5mm) in CM (1:4) on fair surfaces ( height upto 10 mtr) of brick or concrete work height up 6 RM and finished even & fair with using WPC on walls complete all as specified.(Note: WPC measured and paid separately)
M&L for applying two coats of cement based paintover priming coat with alkali resistant priming paint including preparation of new surfaces plastered or unplastered, complete all as specified and directed.
M&L for applying two coats of oil bound distemeper over one coat of white putty including preparation of surface complete all as specified and directed .
Supply only integral water proofing compound complete all as specified.
S & F in repair fancy type 125mm size square brass CP shower rose with or without swivel joints suitable for fixing to steel pipe of 15 mm bore complete all as specified and as directed.
Dismantling wrought iron / Mild Steel work of any description not otherwise provided for complete all as specified and directed.
S & F MS joist channel , angle or Tee section MS tubes, flats square bars etc fixed indepently or framed or without connecting plates, (cut to ordinary lengths i.e. within 20mm of the length indicated) trusses etc any type framing including purlins and rafters etc confirming to Fe 410-W (Gde -E-250) Quality A complete all as specified and directed.
S&F Expanded metal in available size weight not exc. 4.00 kg per Sqm cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members complete all as specified and directed.
Dismantaling of asbestos cement (Corrugated, semi corrugated etc) sheetiting in roof covering all as specified and directed by Engineer-in-Charge.
S & F for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed.
S & F 1000 litre rotational moulded tripple layer polyethlene water storage tanks white colour (cylindrical vertical with closed top) and suitable size of MS tasla with locking system hoisted and fixed in position all as specified in SSR Pt-I including for hoisting into position either inside or outside of building, connecting up pipes, securing access cover etc including GI nipple of suitable size complete all as specified and directed.
Dismantling of water tanks capacity exc 500 ltrs and n.exc 1000 ltrs and removing to store complete all as specified and directed.
M&L 75mm thick cement concrete 1:3:6 type C-2 (using 20mm graded stone aggregates as in plinth protection finishing cement concrete even and fair without using extra cement making 10mm wide and 30mm deep joints at each corner and at every 3.00 mtr interval filling the same with mastic filling i.e one part of bitumen 85/25 and 3 part of sand complete all as specified and directed.
S&F in repair Vitreous China Urinal, Half stall type, white 2Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) Complete all as specified and directed by Engr in Charge
S&F 75 mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified.
Demolition and breaking up drain pipes 100 mm dia(Salt glazed ware, AC, PVC PIPE or reinforced concrete) set in cement mortar incl cleaning sludge/wastage etc at shaft portion of bldg where new pipes to be fixed complete all as specified and directed.
S&F 110 mm bore PVC(SWR) pipes single sockets in any length with rubber ring joints fixed to walls / floors etc complete all as specified and directed.
S&F in repair tubular towel rail 20mm dia 60 cm long between flange, brass chromium plated including bracket complete all as specified and directed
Taking down copper/aluminium point wiring of any description and any position (light, fan, socket or power point) complete, including fixture and fittings such as switches,socket, ceiling rose,lamp holder,pendants, bracket and regulator etc and removing material from site including making good disturbed surface to match with the existing surface complete all as specified.
M&L for point wiring with 1100 volt grade PVC insulated and unsheathed 1.5 Sq mm (FRLS) multistranded copper conductor cable with continuous earth wire of 1.5 Sq mm (FRLS) multistranded copper conductor cable PVC insulated and unsheathed, drawn in & including concealed PVC rigid conduit medium grade with fittings (ISI marked) sunken pressed steel galvanised terminal boxes with top cover ISI marked plastic laminated hylam sheet for housing/ fixing switches etc for One light/fan/exhaust fan point controlled by one switch complete all as specified and directed for the following- Note- (i) The quoted rete is deemed to be included for the chases cutting. (ii) Cutting chases for concealed shall be made good using CM 1:4 and surface finished to match the existing surface & colour.
Ditto as above but for One 5 pin 5 Amp socket point on same board.
Ditto as above but for one 16 Amp 6 Pin switch socket combination independent with 4.0 Sqmm FRLS unsheathed copper conductor single core multistranded complete all as specified.
S&F Switch Piano flush type 5 Amp single pole one way cement complete all as specified.
S&F Socket outlet 2 in 1, 3 pin, 6A cement complete all as specified.
S&F Switch socket combination 2 in 1 flush type 16 Amp 5 Pin complete
S&F Ceiling rose PVC/Poly carbonate isolated body three terminal AC 230 volts complete all as specified and directed.
Supply and fixing in repair of MCB distribution board SPN 240 Volt 8 way with 200 Amp rated bus bar having IP-43 protection and double metal door concealed in wall including connection with aluminium thimbles as required complete all as specified.
S&F of MCB SPN 40 to 63 Amp 240 volt 'C' curve complete all as specifed and directed.
S&F of MCB SP 6 to 32 Amp 240 Volt 'C' curve 10 KA complete all as specified and directed.
Supply and fixing of LED lights fitting 4 feet, 20 Watt, 220V, AC, Batten type fitting with driver, including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S & F of building security LED Light 30 Watt made up pressure die-cast aluminium housing with high power LED as lighting source and lens embedded PC having top opening separate driver compartment with IP-65 protection and impact resistance of IK 07 for building secuity purpose with bracket size made of GI pipe medicum grade 40 mm dia 1.5 mtr long bend to shape as required and fixing with two nos MS Clamp of size 40x6 mm for fixing of builiding security light fittings complete all as specified and directed.
Supply and Laying cable XLPE Insulated screened PVC bedded, galvanized steel strip armoured service cable pole to building electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 Sqmm 2 Core complete incl dismantling all as specified and directed.
S & F of 25 mm bore GI Tubing light grade with all fittings laid across road, in trenches or across PCC drain, along electric pole or floor/wall for cable protection with suitable size of MS Clapms and nut and bolts/washer complete incl dismentling all as specified and directed.
Supply and laying sand with approved fine grade sand around cable in cushioning for protection of under ground cable complete all as specified and as directed. Note:- (only punned and consolidated volume to be measured)
Supply and laying kiln burnt bricks best quality locally available old size sub class 'B' bricks laid flat in trenches with axis of brick perpendicular to the axis of cable for cable protection complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 mtrs wide and not exceeding 1.5 mtrs in depth for laying of cables including getting out in any type of soil complete all as specified and directed.
Returning filling in including spreading, leveling ,and well ramming, in layers not exceeding 25 cm each layer of any type of soil complete all as specified and directed
Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point complete all as specified and directed
S&F in repair of metal plug & socket DB with metal plug and MCBs single pole and neutral enclosere with a two pin earth plug and socket suitable for 20 Amp complete with one single pole MCB complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick, burried directly into the ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to GI earth wire 4 mm dia by means of bolts, nuts, check nuts, and washers of galvanised iron or steel all as shown in electrical plate No - 3 connected to earthing test point all as specified or indicated including excavation and connected earth work, PCC chamber and cover, watering pipe, funnel wire mesh but without earth lead protection pipe and test on completion after dismantling unserviceable erthing (above GL only) complete all as directed incl dismantling of exsisting earthing. (Note :- On testing after completion if desired earth resistence is not obtained, the earthing will be redone at no extra cost.)
M/S S P CONSTRUCTION (BID ID -3313837)
M/S shree traders (BID ID -3314404)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .