| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.5 LAccepted-AOC | ₹18.5 L Quoted ₹18.8 L | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹19.2 L+₹45,040 (2.40%)Rejected-Finance RZ 18 260 WEST SAGARPUR NEAR MCD SCHOOL NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | ₹19.2 L+₹45,040 (2.40%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹21.0 L+₹2.2 L (11.8%)Rejected-Finance WZ 831 NANGAL RAYA PANKHA ROAD NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | ₹21.0 L+₹2.2 L (11.8%) | L3 | Rejected-Finance Other than lowest |
| 4 | Rejected-Technical | - | - | Rejected-Technical No, requisite category not found in enlistment letter |
Tender Value
₹20.6 L
EMD Value
₹41,300
Closing Date
24 Sept 2021, 6:00 pmClosed
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
GE UTILITY PLANT AND MACHINERY KIRBY PLACE DELHI CANTT-10
COMP MAINT OF CENTRAL AC PLANT OF CAP(3X60TR)INSTALLED AT HQ CICG TG,CENTRAL AC PLANT OF CAP(2X24TR)AC PLANT INSTALLED AT ERG 3ETH,CENTRAL AC PLANT OF CAP(3X30TR)INSTALLED AT NBCE LAB,PACKAGE TYPE AC PLANT OF CAP(3X11TR)INSTALLED AT LOGISTIC SEC ETC
2021_MES_464266_2
GE(U)/PM/D-27/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
334 days
DELHI CANTT
MES contractor enlisted under class E category c(i) having deposited standing security of Rs 50000 with department. Contractor not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category.
6 documents required · 6 mandatory
₹500
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
₹41,300
Yes
8 Oct 2021
3 Sept 2021
27 Sept 2021
3 Sept 2021
24 Sept 2021
10 Sept 2021
Amount
SECTION - I
Taking out old unserviceable/ burnt out Electronic expansion valve drive for 60 TR AC Plant. Supply and fixing of new Electronic expansion valve drive including programming for analog signal positioner for motherboard Model No DCO 3000 HSN code - 853700 of make Kirlosker complete all as specified and as directed.
Supply and fixing loading coil, 12-15 Watts suitable for 60 TR chiller unit model- CXH0180298Y of make Rotex including taking down old unserviceable one complete all as specified and as directed.
Supply and fixing Voltage protection device,440 V for 30 TR AC plant including taking down old unserviceable one complete all as specified and as directed. (Make: SOFTHARD or equivalent)
Supply and fixing motor protection device,30-220 amps for 30 TR AC plant including taking down old unserviceable one complete all as specified and as directed. (Make: SOFTHARD or equivalent)
Supply and fixing in repairs chiller sensor suitable for Bluestar chiller unit Model no. XWCS2026AR2 of 25 TR as per existing model and make complete all as specified and as directed.
SECTION -II
Periodical, preventive and comprehensive maintenance of Central Air conditioning plant of capacity (3 x 60 TR) as per manufactures manual of preventives and comprehensive maintenance and with periodicity mentioned there in as per particular specification including servicing of units installed at HQ CICG TG for equipments as listed below :- (a) Periodical, preventive and comprehensive maintenance of complete Screw type water chilling machine (60 TR) -03 Nos, each consisting of 1 No 60 TR Screw type compressor, Chiller shell and tube, Condenser shell and tube, microprocessor based control panel complete system through OEM/ manufacturer i.e. any one of M/s Blue Star/Trane/Voltas/ Hitachi/ Carrier including submission of quarterly service reports from OEM. Total No. Chiller units-03 Nos. (b) Preventive, comprehensive and general routine maintenance of following equipments :- (i) Condenser water mono block pump set 10 HP - 03 Nos. (ii) AHUs complete with accessories such as casing, chilled water coil, hot water coil, any type of air filters, drive motors control panel etc. complete-06 Nos. (iii) Compressor water pipe lines and its control valves complete-Lot. (iv) Chiller water pipe lines and its control valves – Lot. (v) FRP induced draft Cooling tower of capacity 75TR - 03 Nos (vi) Chiller water mono block pump set 7.5 HP - 03 Nos.(vii) Hot water generator 75 KW - 02Nos (viii) Hot water pump set 3 HP - 02 Nos.(ix) Expansion tanks including their insulation for chilled water and hot water system-01 No. (ix) Supply air ducting complete, aluminum section grills/diffusers its dampers, fire dampers complete. (x) Cubical type floor mounted main LT panel complete consisting of control switch gear, starters of pump sets, cooling towers and its single phase preventers, no volt and under volt protection system, meters indication lamps complete (xi) Sub control panel provided for AHUs including controls starter meters and protection system. (xii) Central control panel comprising of ON/OFF push buttons and ON/OFF indication lights. (xii) LT cables from main electrical panel to compressor motor, Pump motors, cooling tower motors, sub panels of AHUs units and control cables of central control panel complete –One Lot.
Periodical, preventive and comprehensive maintenance of Central Air conditioning plant of capacity (2 x 24 TR) as per manufactures manual of preventives and comprehensive maintenance and with periodicity mentioned there in as per particular specification including servicing of units installed at ERG, 3 ETH at 505 ABW for equipments as listed below :- (a) Periodical, preventive and comprehensive maintenance of complete water cooled scroll chiller package having 2 Nos compressor of cap 24 TR- 2 units, each consisting of 2 Nos 12.5 TR scroll type compressor, Chiller shell and tube, Condenser shell and tube, microprocessor based control panel complete system through OEM/ manufacturer i.e. any one of M/s Blue Star/Trane/Voltas/ Hitachi/ Carrier including submission of quarterly service reports from OEM. Total No. Chiller units-02 Nos. (b) Preventive, comprehensive and general routine maintenance of following equipments :- (i) Centrifugal pump set, electric driven for condenser 3 HP – 02 Nos. (ii) Centrifugal pump set, electric driven for Hot water generator 3 HP – 02 Nos. (iii) Centrifugal pump set, electric driven for chilled Water 5 HP – 02 Nos. (iv) AHU from 1500 CFM to 5000 CFM – 07 Nos. (v) Electrically operated hot water generator of Capacity 30 KW complete with automatic and safety controls such as safety valve, purge valve, high limit cut out, automatic and manual reset, low level cut out stop controller, thermostat, heaters including its control panel-02 Nos.(vi) Hot water piping, insulation, fittings control valves connected between hot water unit to pump set and pump set to various AHUs-Lot. (vii) Supply air ducting complete, aluminum section grills/diffusers its dampers, fire dampers complete. (viii) Cubical type floor mounted main LT panel complete consisting of control switch gear, starters of pump sets, cooling towers ,meters indication lamps,sub control panel provided for AHUs complete (ix) LT cables from main electrical panel to compressor motor, Pump motors, cooling tower motors, sub panels of AHUs units floor mounted and ceiling suspended complete –One Lot.
Periodical, preventive and comprehensive maintenance of Package type AC plant of capacity (3 x 11 TR) as per manufactures manual of preventives and comprehensive maintenance and with periodicity mentioned there in as per particular specification including servicing of units installed at Logistic Section, 505 ABW for equipments as listed below :- (a) Periodical, preventive and comprehensive maintenance of complete Package type AC plant of capacity (3 x 11 TR) -03 Nos, each consisting of 2 Nos 5 TR Hermetic Compressor, Make- Denfoss,2 Nos air cooled Condenser, microprocessor based control panel complete system through OEM/ manufacturer i.e. any one of M/s Blue Star/Trane/Voltas/ Hitachi/ Carrier including submission of quarterly service reports from OEM. Total No. of package units-03 Nos. (b) Preventive, comprehensive and general routine maintenance of following equipments :- (i) Hermetic Compressor, Make- Denfoss – 06 Nos (ii) Humidity Pump – 01 No (iii) Condenser Unit 11 TR Cap - 03 Nos. (iv) Electric control panel in plant room - 01 Nos. (v) AHU with cooling coil and blower motor 3 HP - 01 Nos.
Periodical, preventive and comprehensive maintenance of Package type AC plant of capacity (2X 7.5 TR) as per manufactures manual of preventives and comprehensive maintenance and with periodicity mentioned there in as per particular specification including servicing of units installed at Recoil Section at 505 ABW for equipments as listed below :- (a) Periodical, preventive and comprehensive maintenance of complete Package type AC plant of capacity (7.5 TR) -02 Nos, each consisting of 1 No 7.5 TR Reciprocatrng Compressor Model ADC PU ASPI 75 P Make - Voltas,1 No.Air cooled Condenser, microprocessor based control panel complete system through OEM/ manufacturer i.e. any one of M/s Blue Star/Trane/Voltas/ Hitachi/ Carrier including submission of quarterly service reports from OEM. Total No. Chiller units-03 Nos. (b) Preventive, comprehensive and general routine maintenance of following equipments :- (i) AHU with cooling coil & Blower Motor 3 HP-02 Nos. (ii) Electric control panel in plant room - 01 Nos. (iii) Voltage Stabilizer 20 KVA - 01 Nos. (iv) Strip heaters, 3 kW, Make-Dasspass- 06 Nos (v) Supply air ducting complete, aluminum section grills/diffusers its dampers, fire dampers complete. (vi) Cubical type floor mounted main LT panel complete-1 No.
NOTE FOR ITEM NO. 2.01 to 2.05:- (a) The comprehensive maintanance of plant under this contract shall be done through Manufacturer i.e. any one of M/s Blue Star/Trane/Voltas/ Htachi/ Carrier. The contractor will have to submit MoU on stamp paper of Rs. 100/- duly notarized as per proforma (on serial page No. 111 & 112) within twenty eight days from date of acceptance of tender, failing which the contract will be liable to be cancelled and work will executed as per policy invouge of the contractors default. (b) Contractor has to carry out all major and minor break down/repairs pertains to complete machineries of central AC Plant & connected cooling tower AHUs rates quoted is deemed to be included for all except any damage due to natural disasters such as flash, floods, earth quake, cyclone etc. (c) The contractor shall carry out routine checking of the complete system and rectify the minor/major defects noticed immediately. Cleanning of fine air filter such a way that all AHUs are cleaned once in a month and making a maintenacne register for above maintenance and one separate register to be maintained as complete register received from deptt and taking signature from users after recrifying the defects if any. The contractor will arange to clean all the grills/ducts/filters on regular basis with vaccurn cleaner & other appliances and record to be maintained. If complaints were not attended after six hours the following penalties will be imposed and deducted from payments. :- (i) Rs. 200/- per complaint for not attending the complaint and keeping pending from six hours to 12 Hour/per complaint. (ii) Rs. 500/- per complaint for not attending the complaint and keeping pending 12 hours to 24 hours/per day.
(d) Contractor should provide one technician to attend local complaints, minor faults, routine cleaning of filters and grills and other clanging and maintenance work in day shift 0700 hrs to 1500 hrs. (e) All consumables such as de scaling solution (use latest solution) having very less quantity of acid and other maintenance materials such as,oil, lubricants, grease, gland packing thimbles, etc. will be deemed to be included in the quoted rate. (f) In case of break down, the additional manpower if required will be arranged by the contractor. The cost of the same are deemed to be included in the quoted rate. (g) Required refrigerant gas and compressor oil for maintanance including initial topping up if required of Plant are deemed to be included in the quoted rate. (h) The rate of note No. (a) to (g) above are deemed to be included in the quoted rate.
SECTION -III
Supply and fixing in repairs thermostat for AHU room, as per existing size & specification complete all as specified and as directed. (Make:-SIEMENS/ DANFOSS/ INDFOSS/ANERGY).
Supply and fixing in repairs 3 Pole power contactor MNX 32 complete all as specified and as directed. (Make:-SIEMENS/ LEGRAND/ L&T/ABB/SCHNEIDER/ GE POWER).
Supply and fixing in repairs 3 Pole power contactor MNX 25 complete all as specified and as directed. (Make:-SIEMENS/ LEGRAND/ L&T/ABB/SCHNEIDER/ GE POWER).
Supply and fixing in repairs 3 Pole power contactor MNX 18 complete all as specified and as directed. (Make:-SIEMENS/ LEGRAND/ L&T/ABB/SCHNEIDER/ GE POWER).
Supply and fixing in repair 3 pole power contactors type MNX 70,AC-3 rating, 2NO + 2 NC,Cat No ST19002 complete all as specified and as directed. (Make L&T/ LEGRAND/ ABB/ SIEMENS)
Supply and fixing in repairs cast iron butter fly valves lever operated SS disc type nitrile/EPDM rubber lining PN 16 of dia 125 mm complete all as specified and as directed. (Make: - ADVANCE/ AUDCO/ LEADER/CASTLE/ NVR/ ZOLOTO/SANT).
Supply, Installation, testing and commissioning FRP type cooling tower 75 TR capacity with all connected accessories including necessry brick work foundation with sub class 'B' bricks straight or curved with 1:4 cement mortar similar to existing foundation in size and specifications and fabrication work at HQ CICG TG AC Plant complete all as specified and as directed. (Make:- Delta/Mihir/Paharpur)
Supply and fixing in repairs Star Delta starters for motors of 10 HP capacity with suitable rating relay, suitable for mounting on existing LT Panels of AC plants and connections with suitable size single core copper conductor wire complete all as specified and as directed. (Make -L&T/Siemens/Legrand/ ABB/Crompton.)
Supply and fixing in repairs Single Phase Preventer of frequency 50-60Hz for Chiller/condenser pumps complete all as specified and as directed. (Make:-HAVELLS/ L&T/MINILEC/ C & S).
Supply and fixing in repairs over load relay 6-10 Amps complete all as specified and as directed. (Make:-SIEMENS/ LEGRAND/ L&T/ABB/SCHNEIDER).
Supply and fixing in repairs Immersion heaters of cap 5/6 KW required as site condition 230/440 volts as required complete all as specified and as directed. (Make : Dasspass/crown/Theata)
S&F in repair of temeperature Sensors of the chiller and condenser lines operates by mercury liquid of range 0-50⁰C complete all as specified and as directed. (Make:Fiebig/H guru/AE)
Supply and fixing in repair MCCB 125 Amps, 3 pole,3 phase, 415 volts , breaking capacity 25 KA thermal magnetic release, complete all as specified and as directed. (Make L&T/ LEGRAND/ ABB/ SIEMENS/ SCHNEIDER)
Supply and fixing in repair MCCB 100 Amps, 3 pole, 3 phase, 415 volts , breaking capacity 25 KA thermal magnetic release complete all as specified and as directed. (Make L&T/ LEGRAND/ ABB/ SIEMENS/ SCHNEIDER)
Supply and fixing in repair MCB four pole 40 Amps,415 volt, C curve, breaking capacity 10 KA complete all as specified and as directed. (Make L&T/ LEGRAND/ ABB/ SIEMENS/ SCHNEIDER )
Supply and fixing in repairs terminal base 6 Pole including nuts,bolts with washers for 5 HP to 30 HP Motor complete all as specified and as directed. (Make - ABB/Kirlosker/Jyoti)
Supply and fixing in repairs of over load coil MN 2 type, 20-33 amp as required or as directed.(Make:-SIEMENS/ LEGRAND/ L&T/ABB/SCHNEIDER).
Supply and fixing in repair connector 30 amps to 70 amps complete all as specified and as directed. (Make: as per sample).
Supply and fixing in repair fan belt of size B-43,A-58,A-50.A- 34 to A-41 complete all as specified and as directed. (MaKe: Fenner/ Dunlop or equivalent as approved by Accepting officer)
Supply and fixing in repair add on block 2 NO/2NC suitable for MNX 12 to MNX 25 complete all as specified and as directed. (Make L&T/ LEGRAND/ ABB/ SIEMENS/SCHNEIDER)
Supply and fixing in repair MCCB 250 Amps,3 phase,415 volts breaking capacity 35/36 KA adjustable over load setting complete all as specified and as directed. (Make L&T/ LEGRAND/ ABB/ SIEMENS/SCHNEIDER)
Supply and fixing in repairs compound gauge of size 100 mm for water pipe line including siphon, cock complete all as specified and as directed. (Make: Fiebig/ H Guru/ AE)
Supply and fixing in repairs strip heater heaters of cap 3 KW 230/440 volts as required complete all as specified and as directed. (Make : Dasspass/Crown/Theata)
Supply, installation and testing of cooling coil as per the following specifications including taking down old unserviceable one complete all as specified and as directed :- (Note:- Quoted reates should includes transporting of new cooling coil from the factory to the site) (a) Size -70"x30" (b) Row deep - 4 (c) Material of fins - Alluminum (d) Size of Cu pipe oute dia -5/8" (e) Test pressure- 250Psi (f) Gauge of outer frame - 20SWG
Supply and fixing in repairs cast iron Y strainer flanged ends with SS perforated sheet screen of size 125 mm complete all as specified and as directed. (Make: - ADVANCE/ AUDCO/ LEADER/CASTLE/ NVR/ ZOLOTO).
Supply and fixing in repairs acoustic insulation in AHU rooms with aluminium perforated sheet having perforation between 20-40% and of thickness not less than 0.8mm fixed over the surface with screws complete all as specified and as directed.
Supply and fixing in repairs PVC eleminators of size 600x300x150 for Cooling Tower, complete all as specified and as directed. (Make as per sample)
Supply and fixing in repairs of PVC fins of size 600x300x150 for Cooling Tower, complete all as specified and as directed. (Make as per sample)
Supply and fixing in repairs of Pre filter 10 micron of size 600 mm x 600 mm x 50 mm in repair made out of GI wire mesh interspaced with two crimp layers and three flat layers flanged deep box type and efficiency 90% as per existing size and pattern for AC Plant air handling unit complete all as specified and as directed. (Make - Athlete or equivalent ISI marked)
Supply and fixing in repairs of Pre filter 10 micron of size 600 mm x 300 mm x 50 mm in repair made out of GI wire mesh interspaced with two crimp layers and three flat layers flanged deep box type and efficiency 90% as per existing size and pattern for the all three AC Plant air handling unit complete all as specified and as directed. (Make - Athlete or equivalent ISI marked.)
NOTE FOR SECTION I & III (Item No 1.01 to 1.05 and item No 4 to 34):- Cost of Section- I and III are not included in Section- II item Nos 2.01 to 2.05
P S TRADERS
Tushar engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .