Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.1 CrAccepted-AOC 7 1 214 4 2ND FLOOR D K ROAD AMEERPET HYDERABAD TELANGANA 500016 | MEDCHAL MALKAJGIRI | TELANGANA | 500016 | ₹9.1 Cr | L1 | Accepted-AOC L1 accepted |
| 2 | L2₹9.8 CrRejected-AOC | ₹9.8 Cr | L2 | Rejected-AOC L2 Rejected |
| 3 | L3₹10.4 CrRejected-AOC | ₹10.4 Cr | L3 | Rejected-AOC L3 Rejected |
| 4 | L4₹13.3 CrRejected-AOC | ₹13.3 Cr | L4 | Rejected-AOC L4 Rejected |
Tender Value
₹10.6 Cr
EMD Value
₹21.1 L
Closing Date
27 Jun 2023, 4:00 pmClosed
The Project Manager, IGMCRI
PM Office, IGMCRI, Kathrikamam, Puducherry.
Balance Air Conditioning Work for Floor-5 of Hospital Block of Indira Gandhi Medical College and Research Institute at Kadirkamam, Puducherry
2023_MH_12776_1
12/IGMCRI/EC/EEE/23-24
Open Tender
Miscellaneous Works
180 days
IGMCRI, Kathrikamam
Please Refer Tender Documents
4 documents required · 4 mandatory
₹1,575
₹21.1 L
6 Jul 2023
2 Jun 2023
28 Jun 2023
2 Jun 2023
27 Jun 2023
2 Jun 2023
Amount
Refrigeration Plant Water Chilling Units
Supply, installation, commissioning & testing of 250TR water cooled screw type chilling unit, as specified & shown in the data sheet (WCU) complete with: i) Loading, unloading, civil works & lifting into position ii) Full charge of refrigerant iii) Vibration mounts & flexible connections iv) Microprocessor Based Control Panel v) Bacnet compatible protocol to integrate operation with 3rd party Building Management System. vi) Starter and isolator as specified
Chiller Management System for upto 3 chillers (2 Working + 1 Future)
Cooling Tower Supply, Installation, Testing & Commissioning of Induced draft cooling towers as specified and shown in the data sheet (CLT) consisting of: a) All internals & externals, access ladder. b) Fans, motors & drives. c) Supporting arrangements & Platform in structural steel at 3m above floor plus maintenance platform including civil works d) Flexible connections & Vibration isolators e) Earthing of motor etc. Cooling towers as per data sheet CLT
Chilled Water Pumps Installation, testing & commissioning of existing pumps as specified and shown in the data sheets consisting of: (Pump will be Supplied by IGMC & RI) i) Flexible connections including civil works ii) Earthing of motor & frame iii) Flexible connectors on both sides & Vibration Isolators Note: the existing motor shall be checked before installation
Primary Chilled water pumps with insulation- Data sheet CHWPP
Secondary Chilled water pumps with insulation- Data sheet CHWSPS
Condenser water pumps with insulation. Data sheet CDWP
Air Handling Units Supply, Installation, Commissioning & Testing of Double Skinned Air Handling Units as specified and shown on drgs. and on data sheets, flow diagram etc. and consisting of: i) Fan section & flexible connections on supply and return ii) Cooling coils iii) Prefilters, microvee filters & HEPA filters as specified iv) Drain pan v) Motors with drive package, starter panel with starters / VFD with electrical power & control cabling from starter to motor, earthing of motor electrical reheat generally as per data sheets vi) Return fan section, HR section for TFA units vii) Necessary vibration isolators & supporting frame as specified in data sheets, including civil works viii) 25mm dia ball valve
Air handling unit to OT 1 AHU-5-1
Air handling unit to OT 2 AHU-5-2
Air handling unit to OT 3 AHU-5-3
Air handling unit to OT 4 AHU-5-4
Air handling unit to OT 5 AHU-5-5
Air handling unit to OT 6 AHU-5-6
Air handling unit to OT 7 AHU-5-7
Air handling unit to OT 8 AHU-5-8
Air handling unit to Sterile Area AHU-5-9
Air handling unit to Corridor & Doc's Lounge AHU-5-10
Air handling unit to OT Store,OP ward & OP Holding AHU-5-11
Air handling unit to Relative Cubicle For Men AHU-5-12
Air handling unit to IMCU AHU-5-13
Air handling unit to Surgical ICU -1 AHU-5-14
Air handling unit to Surgical ICU -2 AHU-5-15
Air handling unit to Corridor at Surgical ICU AHU-5-16
Air handling unit to Respiratory ICU AHU-5-17
Air handling unit to Main Corridor & Relative Waiting Area AHU-5-18
Air handling unit to Relative Cubicle For Women & Corridor AHU-5-19
Air handling unit to Pediatrics ICU AHU-5-20
Air handling unit to Gynaecology ICU AHU-5-21
Air handling unit to CCU AHU-5-22
Air handling unit to Pre Function & Lecturer Theatre AHU-5-23
Air handling unit to Anaesthesiology Department AHU-5-24
Air handling unit to Septic OT AHU-5-25
Air handling unit to Clean OT1 AHU-5-26
Air handling unit to Clean OT2 AHU-5-27
Air handling unit to Corridor at Court 2 AHU-5-28
Air handling unit to Anti Natal & Post Natal Ward AHU-5-29
Air handling unit to Clean Labour Room AHU-5-30
Air handling unit to Septic Labour Room AHU-5-31
Air handling unit to Post OP Ward & Corridor at Court 2 AHU-5-32
Sheet Metal Ducting, Air- Conditioning System (Factory made only) Supply, fabrication and erection of galvanised sheet metal ducting generally as specified including civil work complete with i) Galvanised companion flanges girth angles. ii)Turning vanes. iii) Galvanised structural support systems. iv) Sealing gasket to meet specifications v) Painting of all duct supports and exposed ducting
0.63mm (24 G) galvanised sheet steel
0.80mm (22 G) galvanised sheet steel
1.00mm (20 G) galvanised sheet steel
Dampers Manual Volume control dampers as specified.
Splitter dampers as specified.
Fire & smoke dampers with actuator, transformer as specified for the size given under
Upto 0.3 sqm
From 0.3 sqm to 0.6 sqm
From 0.6 sqm to 0.9 sqm
From 0.9 sqm to 1.2 sqm
More than 1.2 sqm
Supply and installation of Return air extruded aluminum Powder coated grills as specified and complete with i. 10mm Margins ii. Circular / square or rectangular as shown in drawings
Supply & Return air diffusers of extruded aluminum, powder coated as specified and complete with: i) Flush or stepdown ii) 20mm flanges with PVC gasket iii) Mild steel butterfly damper or in-built damper. iv) Circular, square, rectangular or as shown on drawings. v) 1-way, 2-way, 3-way as specified Note : From AHU to OT and related works are part of the OT Vendor scope.
150 x 150 square
225 x 225 Square
300 x 300 square
375 x 375 square
Thermal & Acoustic Insulation Thermal insulation for indoor ducts as specified complete with Al.foil faced nitrile rubber Insulation
19 mm (SA ducts running in airconditioned space)
25 mm (SA ducts running in non airconditioned space)
13 mm (RA ducts running in airconditioned space)
25 mm (RA ducts running in non airconditioned space)
Thermal insulation for outdoor ducts as specified complete with: i) Insulation with phenotherm with foster coating ii) Vapour barrier iii) Final finish as specified. 50mm thick
Duct acoustic insulation generally as specified and complete with: 25 mm thick Armasound
Plant room acoustic insulation generally as specified and complete with: i) Insulation ii) Framing GI channel frame work as specified. iii) Finish with 0.8mm thick perforated aluminium sheet. 50mm thick (for AHU rooms only)
underdeck insulation generally as specified and complete with: 19mm thick Closed Cell Nitrile Rubber Insulation
Ventilation & Exhaust Systems Ventilation Fan Systems Supply, installation, commissioning & testing of VENTILATION SYSTEMS in accordance with and meeting the intents 'of the specifications and data sheets including civil works complete with:
Toilet Exhaust Fan to data sheet TOI - EF 1,1Phase, Slimline Axial Fan,2500 RPM,Kruger DWA Series OR Equivalent
Toilet Exhaust Fan to data sheet TOI - EF-2, 1Phase, Slimline Axial Fan,2500 RPM,Kruger DWA Series OR Equivalent
Toilet Exhaust Fan to data sheet TOI - EF-3,1Phase, Slimline Axial Fan,2500 RPM,Kruger DWA Series OR Equivalent
Toilet Exhaust Fan to data sheet TOI - EF-4,1Phase, Slimline Axial Fan,1300 RPM,Kruger APM Series OR Equivalent
Toilet Exhaust Fan to data sheet TOI - EF-5,1Phase, Slimline Axial Fan,1300 RPM,Kruger APM Series OR Equivalent
Exhaust Fan for Dirty Corridor to data sheet TOI - EF-6,1Phase, Slimline Axial Fan,1300 RPM,Kruger APM Series OR Equivalent
Piping & Insulation Supply & laying of MS piping generally as specified including civil works with complete (Including Dismantling existing pipes)
350mm dia Nominal Bore
300mm dia Nominal Bore
250 dia Nominal Bore
200 dia Nominal Bore
150 dia Nominal Bore
100 dia Nominal Bore
80 dia Nominal Bore
65 dia Nominal Bore
50 dia Nominal Bore
40 dia Nominal Bore
32 dia Nominal Bore
Supply and laying of RCC Hume Pipe for Burried Piping crossing roads including civil works Dia 600mm
Supply and laying CHILLED WATER PIPING WITH INSULATION - BURRIED including Civil Work
Dia 300mm - (6.35 mm thick)+ 75 mm thick insulation (Puff Insulation with HDPE Jacetting)
Dia 250mm - (6.35 mm thick)+ 75 mm thick insulation (Puff Insulation with HDPE Jacetting)
Insulation as per specifications over pipe of following NB including valves etc. as specified complete with finish specified Indoor
300 dia Nominal Bore (Puff Insulation -50 mm)
250 dia Nominal Bore (Puff Insulation -50 mm)
200 dia Nominal Bore (Puff Insulation -50 mm)
150 dia Nominal Bore (Puff Insulation -50 mm)
100 dia Nominal Bore (Puff Insulation -50 mm)
80 dia Nominal Bore (Puff Insulation -50 mm)
65 dia Nominal Bore (Puff Insulation -50 mm)
50 dia Nominal Bore (Puff Insulation -50 mm)
40 dia Nominal Bore (Puff Insulation -50 mm)
32 dia Nominal Bore (Puff Insulation -50 mm)
Insulation as per specifications over pipe of following NB including valves etc. as specified complete with finish specified outdoor.
200 dia Nominal Bore (Puff Insulation -50 mm with Al.Cladding)
150 dia Nominal Bore (Puff Insulation -50 mm with Al.Cladding)
100 dia Nominal Bore (Puff Insulation -50 mm with Al.Cladding)
80 dia Nominal Bore (Puff Insulation -50 mm with Al.Cladding)
65 dia Nominal Bore (Puff Insulation -50 mm with Al.Cladding)
50 dia Nominal Bore (Puff Insulation -50 mm with Al.Cladding)
40 dia Nominal Bore (Puff Insulation -50 mm with Al.Cladding)
32 dia Nominal Bore (Puff Insulation -50 mm with Al.Cladding)
Supply and laying of m.s heavy class piping for drain piping complete with 25mm thick polystyrene or 12mm polyflex generally as specified
100 dia Nominal Bore
50 dia Nominal Bore
Supply & installation of Ball valves complete with holding & mating flange joints as specified. Ball valves
50 dia Nominal Bore
40 dia Nominal Bore
32 dia Nominal Bore
25 dia Nominal Bore
Supply & installation of butterfly valves and Balancing valves complete with holding & mating flange joints as specified. Butterfly valves
300 dia Nominal Bore
250 dia Nominal Bore
200 dia Nominal Bore
150 dia Nominal Bore
100 dia Nominal Bore
80 dia Nominal Bore
65 dia Nominal Bore
Balancing valves 350 dia Nominal Bore
250 dia Nominal Bore
200 dia Nominal Bore
150 dia Nominal Bore
100 dia Nominal Bore
80 dia Nominal Bore
65 dia Nominal Bore
50 dia Nominal Bore
40 dia Nominal Bore
32 dia Nominal Bore
Supply and installation of NR valves & `Y' strainers complete with mating flange joints as specified.
350 dia NR valve
300 dia NR valve
300 dia `Y' strainer
250 dia `Y' strainer
250 dia NR valve
200 dia `Y' strainer
200 dia NR valve
200 dia `Y' strainer
100 dia `Y' strainer
80 dia `Y' strainer
65 dia `Y' strainer
50 dia `Y' strainer
40 dia `Y' strainer
32 dia `Y' strainer
Supply and installation of Flexible Connection.
300 dia Nominal Bore
250 dia Nominal Bore
200 dia Nominal Bore
Supply and installation of solenoid valves (For make up Tank) 40 dia Nominal Bore
Supply & Installation only of Pressure Independent type balancing cum control valve with flanges, unions as required.
100 dia Nominal Bore
80 dia Nominal Bore
65 dia Nominal Bore
50 dia Nominal Bore
40 dia Nominal Bore
32 dia Nominal Bore
Providing instruments, gauges and sundries etc. as specified.
Thermowells
Thermometers/Temp. indicator
Pressure probe
Pressure indicator flexible copper tubing.
20mm automatic air vents with valves
Air separator
Supply and installation of 3.0 m3 closed expansion tank as specified complete with: i) M.S factory fabricated tank with mounting base ii) All necessary valves, flanges and associated fittings iii) Air Separator iv) Drain connection v) Pressurisation Unit
Installation testing & commissioning of existing various sizes / types valves ( Valves will be supplied by IGMC & RI)
Masonary Work Masonry work for making good the open wall surface for pipe lines and ducts using bricks, cement, sand etc., including plastering, the rate including labour, scaffolding and accessories etc. This include core cutting of RCC beams/slabs of various sizes where ever required. All works shall be carried out as per the directions/approval of the Engineer in charge
GEMINI COOLING SYSTEMS PROJECTS PRIVATE LIMITED
V K Building Services Pvt Ltd
VAV Airconditioning
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid