REPAIR REPLACEMENT TO CERTAIN MISC EM WORK IN MD ACCN IN DOMESTIC AREA AND REPAIR MAINTENANCE OF SWIMMING POOL FILTRATION PLANT CHLORINATION IONIZATION PLANT AND CONNECTED WORKS AT AFS JAMMU UNDER GE AF JAMMU
2025_MES_742535_1
CA NO GE/AFJ-70/2025-26
Open Tender
Civil Works
Item Rate
180 days
JAMMU
PLS REFER TENDER DOCUMENT
8 documents required · 8 mandatory
₹500
GE AF JAMMU
₹77,000
Yes
30 Dec 2025
2 Dec 2025
12 Jan 2026
2 Dec 2025
5 Jan 2026
16 Dec 2025
Taking down unserviceable submain wiring and M&L for submain wiring with 2 single core PVC insulated & PVC unsheathed FRLSH cable 1100 Volt grade with 4 Sqmm copper multistranded conductor drawn through and including PVC conduit concealed in wall/ ceiling including one run of 4.0 Sqmm single core multistranded copper conductor 1100 volts grade PVC insulated and unsheathed FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly all as specified and directed by Engineer-in-Charge.(i) Two runs of cable, PVC conduit and earth continuity conductor will be measured and paid as one length only). (ii) Cost of cutting/leaving/forming chases for PVC conduit and its accessories, sinking of MS boxes and making good to match existing surfaces shall be deemed to be included in the unit rate quoted for item).
Supply and fix Earth contnuty conductor or main earthing lead GI strip 32 x 6 mm with porcelain /PVC insulator, saddled not exeeding 400mm spacing for roof conductor/down conductor with fixing screws or buried in ground or drawn in conduit /pipe/duct or fixed to poles or any other indicated situation for loop earthing etc. conductor conneting and jointing completly with Brazing/Welding the overlap portion of any size copper Strip together copper plate/ rod/GI strip etc. as per site requirment Including Taking down old rusted/broken earth continuity strip all as per specified and directed by Engr-in-Charge.
Taking down carefully unserviceable copper/aluminium point wiring (light, fan, socket or power)complete including fixture and fitting such as switches, ceiling rose lamp holder, regulators, sockets, light fittings, wooden terminal boxes, plastic laminated sheet cover, including taking down of DB’s, meter board any type all as specified and as directed.
Point wiring concealed with 1.5 Sqmm copper conductor cable (multistrand) PVC insulated FRLS (unsheathed), drawing in and including PVC conduit 20 mm dia, having wall thickness not less than 2 mm with sunk cast iron/pressed steel terminal boxes made out of 1.2 mm thick sheet including one coat red oxide primer on internal and external surface covered with 3 mm thick hylam brand IS-2036 marked laminated modular sheet cover (for mounting switches, sockets, regulators etc), including 1.5 Sqmm PVC insulated (multistranded) FRLS copper conductor continuous earth wire for one light /fan point/bell point/5Amp Socket controlled by one, one way switch on independent board complete all as specified and directed.
S&F Switch piano flush type single pole 5 Amps, 230 Volts 50 Hz complete all as specified and directed.
S&F MCCB four pole 125 Amps, 36 KA 415 volts.
S&F Switch socket combination ,5A/16A, 5 in 1flush type with fuse & neon incator, complete all as specified and directed by Engr-in-charge.
S&F Switch socket combination ,5A, 5 in 1flush type with fuse & neon incator, complete all as specified and directed by Engr-in-charge.
All as per item No-9 above but for one 3 pin socket out let, 6 Amps on Independent board with the cable 1.5 Sqmm size.
Taking down unserviceable PTL fittings of any wattage/size and Supply and fix LED post top lantern light fitting 20 watt complete With all accessories.
Supply, laying and testing PVC insulated and sheathed flat 10 Sqmm 3 core copper stranded conductor water proof submersible cable fixed to submersible monoblock pump set to starter as directed including taking out old unserviceable cable complete.
Excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth for foundation etc or for shafts, wells, cesspits, manholes pier holes etc not exc. 10sqm on plan and not exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
Supply , laying, jointing & testing of DI Type K-7 pipe, 100mm dia, with socket & spigot ends, with cement morter zinc coated out side as per IS 8329/2000 in standard length suitable for and including push on tyton joints with rubber rings, laid in trenches, including taking up or down old unserviceable water mains (including all fittings), of any type including burning out joints incliding turning water OFF or ON as necessary and taking off and refixing covers, access doors etc.complete all as specified and directed by Engr in charge.
Supply , laying, jointing & testing of DI Type K-7 pipe, 150mm dia, with socket & spigot ends, with cement morter zinc coated out side as per IS 8329/2000 in standard length suitable for and including push on tyton joints with rubber rings, laid in trenches, including taking up or down old unserviceable water mains (including all fittings), of any type including burning out joints incliding turning water OFF or ON as necessary and taking off and refixing covers, access doors etc.complete all as specified and directed by Engr in charge.
M& L for MS/CI/DI fittings such as collar, bends, any type, any dia, any radius, any angle, double end socketted or double flanged or spigot & socket, tail pieces, all socketed or all flanged with an equal & other end tapering bellmouth or flanged plates, connecting pieces straight, both end flanged or socketed of socket & flanged & spigot ends or bellmouth tailpieces, one end flanged & other end spigot or socket or tatering as bell mouth or flanged, caps blank flanges heavy duty suitable for mechanical joint/flanged joint with and including taking down old fitting of any type and any size all as specified & directed by Engineer In Charge Note: Certifiacte for Weight of fitting by the manufacturere shall be submitted before payment.
Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing, conforming to FE-410-W (Gde-E-250) quality A, including applying two coats of synthetic enamel paint over a coat of red oxide primer, including taking down old framed work steel complete all as specified and as directed by Engineer-in-charge.
S&F hard plastic teeth brush for cleaning of swimming pool of size 30 cm length and width not less than 10 cms fixed with light grade GI pipe 15 mm bore of 6 mtr Length.
Supply only copper sulphate of superior quality complete all as specified.
Material and labour for Maintenance/servicing of centrifugal/ monoblock pump set 3.5/5/7.5 HP capacity by means greasing, oiling, replacement of gland of suitable size to stop water leakage from pump set, replacement of coupling, flange and replacement of nuts, bolts etc as directed at site.
Supply only white quartz pebbles of size 8 mm to 10 mm complete all as specified and directed by Engineer-in-charge.
Supply only white quartz pebbles of size 2 mm to 3 mm complete all as specified and directed by Engineer-in-charge
Per job
Rewinding of motor of Induction motor up to 2 HP capacity insulated copper wire of existing gauge and size to achieve the specified / required RPM including taking out old unserviceable winding complete all as specified and directed.
SCHEDULE 'A' PART-II (Schedule of credit) Credit amount of Rs (Refer schedule of credit) for retrieved material mentioned in Sch 'A' Part-II of Tender documents in PDF form will be deducted offline during acceptance of tender of lowest bidder.
tech_bid_open.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.47 MB
BOQ_831494.xls
BOQ • 1.01 MB
tender70.pdf
Tender Documents • 1.62 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .