Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.1 LAccepted-AOC B 235 MULLA COLONY B SECTOR KAROND BERASIA ROAD BHOPAL | BHOPAL | MADHYA PRADESH | 462001 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹24.4 L+₹2.0 L (9.15%)Rejected-Finance 00 A N SINHA ROAD KADAM KUAN PATNA BIHAR 800003 | PATNA | BIHAR | 800003 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹26.2 L+₹3.9 L (17.4%)Rejected-Finance B 134 GANESH MURTHI NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹28.6 L+₹6.3 L (28.1%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| Sl No | Description | Qty | Unit | UMESH ENTERPRISES L2 | SAMEER ELECTRICAL SUPPLIER L1 | Shri Sai Enterprises L3 | MODI CORPORATION L4 |
|---|---|---|---|---|---|---|---|
| 1.00Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below. (ii) Amount of Schedule of credit shall be deducted offline | |||||||
| 1.10 | Taking down old ceiling fan/exhaust fans/wall mounting fan of any capacity/ sweep after disconnecting the electric supplyfrom any site, checking its electrical defect and opening fans for checking of mechanical defect after dismantlling of fan, carrying out repair/ over hauling including removing dust, grease and cleaning of internal mechanical parts of fan with kerosene oil, checking of alignment of shaft, oiling, greasing, checking of worn out bearing and other defective parts, winding, condenser etc; and re-assembling and connecting/ refixing of fans in its original position by providing new nuts, bolts, lock washer and lock/ split pin complete all as specified and directed.
Notes: (i) Rewinding and replacement of defective parts, painting etc. shall be measured and paid seperately. (ii) Burnt out fan shall be kept separately and shall be rewinded at AGE E/M yard and to be hanged in existing position after rewinding. | 550 | Each Job | 50 ₹27,500 Lowest | 80 ₹44,000 | 50 ₹27,500 Lowest | 50 ₹27,500 Lowest |
| 2.00Supply only the following items to be fixed/ replaced against defective parts of fans taking down under item No 1.00 here-in-before:- | |||||||
| 2.01 | (a) Bearing No 6201 of Make: NBC/ SKF/ FAG | 250 | Each | 35 ₹8,750 Lowest | 60 ₹15,000 | 80 ₹20,000 | 90 ₹22,500 |
| 2.02 | (b) Bearing No 6202 of Make: NBC/ SKF/ FAG | 250 | Each | 35 ₹8,750 Lowest | 70 ₹17,500 | 80 ₹20,000 | 100 ₹25,000 |
| 2.03 | (c) Bearing No 6203 of Make: NBC/ SKF/ FAG | 25 | Each | 60 ₹1,500 Lowest | 80 ₹2,000 | 100 ₹2,500 | 160 ₹4,000 |
| 2.04 | (d) Bearing No 6204 of Make: NBC/ SKF/ FAG | 25 | Each | 60 ₹1,500 Lowest | 90 ₹2,250 | 120 ₹3,000 | 180 ₹4,500 |
| 2.05 | (e) Rubber bush suitable for ceiling fan | 400 | Each | 5 ₹2,000 Lowest | 10 ₹4,000 | 20 ₹8,000 | 30 ₹12,000 |
| 2.06 | (f) Condenser 2.5 mfd | 1,000 | Each | 28 ₹28,000 Lowest | 30 ₹30,000 | 30 ₹30,000 | 30 ₹30,000 |
| 2.07 | (g) Condenser 4.0 mfd | 50 | Each | 40 ₹2,000 Lowest | 50 ₹2,500 | 45 ₹2,250 | 60 ₹3,000 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
29 Nov 2025, 6:00 pmClosed
GE BHOPAL
GE BHOPAL BAIARAGARH BHOPAL
COMPREHENSIVE REPAIR MAINT OF CEILING FANS EXHAUST FANS WALL MOUNTED FANS AIR CONDITIONER FAN RO AND SUMMER APPLIANCES AT BAIRAGARH UNDER GE BHOPAL
2025_MES_738894_1
8458/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE BHOPAL
Please refer tender documents
7 documents required · 7 mandatory
₹500
GE BHOPAL
₹70,000
Yes
4 Feb 2026
8 Nov 2025
1 Dec 2025
8 Nov 2025
29 Nov 2025
22 Nov 2025
Amount
Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below. (ii) Amount of Schedule of credit shall be deducted offline
Taking down old ceiling fan/exhaust fans/wall mounting fan of any capacity/ sweep after disconnecting the electric supplyfrom any site, checking its electrical defect and opening fans for checking of mechanical defect after dismantlling of fan, carrying out repair/ over hauling including removing dust, grease and cleaning of internal mechanical parts of fan with kerosene oil, checking of alignment of shaft, oiling, greasing, checking of worn out bearing and other defective parts, winding, condenser etc; and re-assembling and connecting/ refixing of fans in its original position by providing new nuts, bolts, lock washer and lock/ split pin complete all as specified and directed. Notes: (i) Rewinding and replacement of defective parts, painting etc. shall be measured and paid seperately. (ii) Burnt out fan shall be kept separately and shall be rewinded at AGE E/M yard and to be hanged in existing position after rewinding.
Supply only the following items to be fixed/ replaced against defective parts of fans taking down under item No 1.00 here-in-before:-
(a) Bearing No 6201 of Make: NBC/ SKF/ FAG
(b) Bearing No 6202 of Make: NBC/ SKF/ FAG
(c) Bearing No 6203 of Make: NBC/ SKF/ FAG
(d) Bearing No 6204 of Make: NBC/ SKF/ FAG
(e) Rubber bush suitable for ceiling fan
(f) Condenser 2.5 mfd
(g) Condenser 4.0 mfd
(h) Lath work of fan shaft any type / size.
(j) Stainless steel split/ cotter pin
S&F in replacement PVC condenser carrier clip inbuild with two way connector, fixed with screw on down rod or housing complete all as specified and directed.
S&F in replacement upper set of steel clips for down rod with rubber bush (Garari) including set of nuts, bolts, washer and locking pin complete all as specified and directed.
S&F in replacement gun metal bush, self lubricated, any size, suitable for ceiling and wall fans complete all as specified and directed
S&F in replacement PVC flexible copper conductor stranded insulated cable, twin core twisted of 23/0.0076 size, 1100 Volts complete all as specified and directed.
S&F in replacement steel outer frame complete with clamps, rubber packing, nuts, bolts etc. duly painted suitable for 450/ 380 mm sweep exhaust fans complete all as specified and directed.
M&L for rewinding of 1200 mm sweep ceiling fan of any make and model with suitable gauge copper winding wire (super enamelled) including all insulating material, necessary heat varnishing and testing complete all as specified and directed.
M&L for rewinding of 1400 mm sweep ceiling fan of any make and model with suitable gauge copper winding wire (super enamelled) including all insulating material, necessary heat varnishing and testing complete all as specified and directed.
M&L for rewinding of 380 mm sweep exhaust fan of any make and model with suitable gauge copper winding wire (super enamelled) including all insulating material, necessary heat varnishing and testing complete all as specified and directed.
M&L for rewinding of 450 mm sweep exhaust fan of any make and model with suitable gauge copper winding wire (super enamelled) including all insulating material, necessary heat varnishing and testing complete all as specified and directed.
M&L for rewinding of 280/ 300 mm sweep exhaust/ fresh air fan of any make and model with suitable gauge copper winding wire (super enamelled) including all insulating material, necessary heat varnishing and testing complete all as specified and directed.
M&L for rewinding of 400 mm sweep wall mounted fan of any make and model with suitable gauge copper winding wire (super enamelled) including all insulating material, necessary heat varnishing and testing complete all as specified and directed.
M&L for rewinding of 400 mm sweep pedestal fan of any make and model with suitable gauge copper winding wire (super enamelled) including all insulating material, necessary heat varnishing and testing complete all as specified and directed.
Taking down old unserviceable wall mounted & exhaust fan complete with blade assy/ U clamp/ ceiling fan down rod etc. Complete all as specified and directed.
S&F in replacement blade assembly duly powder coated suitable for 300 mm sweep exhaust fan complete all as specified and directed.
S&F of 'U' clamp for hanging ceiling fan in ceiling to be fixed with nuts, bolts, washers and locking pin complete all as specified and directed.
S&F of heavy duty rubber real for ceiling fans complete all as specified and directed.
S&F of ceilling fan down rod of 15 mm bore GI pipe, medium grade (ISI marked) of any length upto 1500 mm including making holes, nuts, bolts, spilt pin, washers etc. complete all as specified and directed.
S&F of PVC insulated multistranded copper conductor sheated round cable of 1.0 Sqmm, 3 core complete all as specified and directed.
M&L for painting to ceiling fan of 1200/ 1400 mm sweep with two coats of DUCO paint, white using spray machine for painting including cleaning, washing and preparation of old painted surfaces and writing MES Nos in all ceiling and exhaust fan complete all as specified and directed.
M&L for painting to exhaust fan of 300/ 380/ 450 mm sweep with two coats of DUCO paint, smoke grey using spray machine for painting including cleaning, washing and preparation of old painted surfaces and writing MES Nos in all ceiling and exhaust fan complete all as specified and directed.
M&L for attending the complaint for not working/ slow speed of fans at site by deploying electrician and checking all electrical connection, tightening/ refixing of any loose electrical connections/ wires, cleaning and oiling of fan, replacement of weak/ unserviceable condensor and making the fan functional without taking down from ceiling complete all as specified and directed. Note: Condensor will be measured and paid under relevant item separately.
S&F in replacement ceiling fan regulator electronic, step type, 240 V, AC 50 Hz, single pole, 100 watts, flush type complete all as specified and directed.
S&F in repairs switch piano, 5 Amps, single pole, one way, flush type complete all as specified and directed.
S&F in replacement ceilling fan down rod of 15 mm bore GI pipe, medium grade (ISI marked) of 600 mm length complete all as specified and directed.
S&F of 1200/ 1400 mm sweep ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 Volts, min air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current motor (BLDC) complete all as specified and directed. Make: Usha/ Orient/ Havells as approved by GE.
S&F of 300 mm sweep exhaust fan, steel body, single phase, 230 Volts AC with blades, frame and louvers complete all as specified and directed. Make: Usha/ Orient/ Havells as approved by GE.
S&F of 250 mm sweep exhaust fan made of sturdy engineering plastic complete with louvers shutter, 230 Volts, 50 Hz, RPM 1200 of copper winding complete all as specified and directed. Make: Usha/ Orient/ Havells as approved by GE.
S&F of 300 mm sweep exhaust fan made of sturdy engineering plastic complete with louvers shutter, 230 Volts, 50 Hz, RPM 1200 of copper winding complete all as specified and directed. Make: Usha/ Orient/ Havells as approved by GE.
S&F of 400 mm sweep wall mounted fan, 240 Volts, 50 Hz, 1350 RPM with copper winding, energy efficient etc. complete all as specified and directed. Make: Usha/ Orient/ Havells as approved by GE.
Taking out existing compressor unit from the water cooler of capacity 40/ 80/ 120/ 150 Ltrs of any type/ make including removal of all unserviceable spare parts such as strainers, filter, capillary tubes suction / discharge pipe, thermostat switch, float valve, push cock, running/ starting capacitor, over load relay etc. complete all as specified and directed.
S&F of new hermitically sealed unit compressor for 40/ 80 Ltr capcity water coolers including necessary welding the same with existing refrigerant pipe with and including supply and charging refrigerant gas and testing complete all as specified and directed. Make: Whirl pool/ Kelvinator/ Hitachi/ Electrolux as approved by GE.
S&F of new hermitically sealed unit compressor for 60/ 120 Ltr capcity water coolers including necessary welding the same with existing refrigerant pipe with and including supply and charging refrigerant gas and testing complete all as specified and directed. Make: Whirl pool/ Kelvinator/ Hitachi/ Electrolux as approved by GE.
S&F of new hermitically sealed unit compressor for 150 Ltr capcity water coolers including necessary welding the same with existing refrigerant pipe with and including supply and charging refrigerant gas and testing complete all as specified and directed. Make: Whirl pool/ Kelvinator/ Hitachi/ Electrolux as approved by GE.
Taking out water cooler of any make and capacity from position and cleaning the complete condenser coil & storage tank with chemical base solution and soda water including servicing, oiling of FHP motor checking of electrical & water supply connection and re-fixing the same on its original position after testing complete all as directed.
M&L for charging of water cooler with R-22/ 134A gas including replacement/ filling of compressor oil of approved make after leakage test and testing of water cooler on full load for 24 hrs continuously at site of any type/ make of capacity upto 150 ltrs complete all as specified and directed.
M&L for shifting of air conditioner split type of any make from its original position to another position with and including making good disturbed surfaces and making electric connection at new location complete all as specified and directed.
M&L for shifting of air conditioner window type of any make from its original position to another position with and including making good disturbed surfaces and making electric connection at new location complete all as specified and directed.
Taking out existing unserviceable fan motor of capacity 1/8 HP from water cooler, dismantling the motor and taking out old burnt copper winding wire, rewinding of fan motor with similar size super enamelled copper winding wire of Make of HTP/ Devidayal after providing 'E' class insulation material including replacement of unserviceable pads, MS clamps, nut and bolt, varnishing & refixing the motor in the water cooler after testing complete all as specified and directed.
S&F in replacement new fan motor of water cooler capacity 1/8 HP, 230 Volt, 50 c/s of make MIE/ Khaitan/ Crompton Greaves complete all as specified and directed.
S&F in replacement of fan blades of fan motor of water cooler of capacity 150 ltr made out of GI sheet as per existing shape and size complete all as specified and directed.
S&F of running capacitor, 36 MFD suitable for water cooler of capacity 120/ 150 Ltr complete all as specified and directed.
S&F of starting capacitor 80-100 MFD suitable for water cooler complete all as specified and directed.
S&F of over load protector as per sample suitable for water coolers complete all as specified and directed.
S&F of starting relay 1/8 HP as per sample suitable for water coolers complete all as specified and directed.
S&F of plunger type relay as per sample suitable for water coolers complete all as specified and directed.
S&F of thermostat switch for water cooler as per sample complete all as specified and directed.
S&F of 15 mm bore float valve, brass with ball complete all as specified and directed.
S&F of rubber hose pipe of 1½” dia and 1.5 m long for drain pipe complete all as specified and directed.
S&F of over load relay complete box type Y-412 complete all as specified and directed.
Taking out existing compressor unit from the refrigerator of any capacity/ make including removing all unserviceable parts/ spares such as over load relay, bulb, strainer, thermostate switch, bulb holder, capillary tubes, freezer door etc. complete all as specified and directed.
Taking out existing compressor unit from the deep freezer of any capacity/ make including removing all unserviceable parts/ spares such as over load relay, bulb, strainer, thermostate switch, bulb holder, capillary tubes, freezer door etc. complete all as specified and directed.
S&F of new compressor to refrigerator of 310/ 280/ 180/ 165 ltrs capacity including jointing capillary tubes and testing the compressor complete all as specified and directed.
S&F of new compressor to deep freezer of capacity 310 ltrs including jointing capillary tubes and testing the compressor complete all as specified and directed.
M&l for charging of deep freezer/ refrigerator with R-22/ R-32/ R-134a gas of capacity 400/ 200/ 310/ 165 Ltrs of any make complete including replacement of compressor oil of approved make and testing complete all as specified and directed.
S&F of plunger type relay, 1/6 HP for refrigerator of approved make complete all as specified and directed.
S&F of over load protector, 1/6 HP for refrigerator of approved make complete all as specified and directed.
S&F of thermostat switch with knob for refrigerator of approved make complete all as specified and directed.
S&F of freezer door for whirlpool refrigerator of capacity 310 ltrs complete all as specified and directed.
S&F in replacement existing damaged choked evaporator tubes from the refrigerator of capacity 310 Ltrs of approved make complete all as specified and directed.
S&F in replacement existing damaged choked evaporator tubes from the refrigerator of capacity 180/ 190/ 165 Ltrs of approved make complete all as specified and directed.
Taking out existing unserviceable fan motor of capacity 1/8 HP from the cooler/ Deep freezer/ Refrigerator by dismantling the motor and taking out old burnt copper winding with and including M&L for rewinding the blower motor with similar size of super enameled copper winding wire of make: HTP/ Devidayal after providing 'E' class insulation material including replacement of bushes, name pad and varnishing including refixing the motor and testing complete all as specified and directed.
S&F in replacement new fan motor of capacity 1/8 HP of cooler/ Deep freezer/ Refrigerator and making necessary connections complete all as specified and directed.
Dismantling/ taking out existing unserviceable window type air conditioner of capacity 1.5/ 2 Ton of any make and refixing the same to its position after complete serviceing with anti-scaling solution and cleaning complete all as specified and directed.
Dismantling/ taking out existing unserviceable split type air conditioner of capacity 1.5/ 2 Ton of any make and refixing the same to its position after complete serviceing with anti-scaling solution and cleaning complete all as specified and directed.
S&F in replacement new compressor to window type air conditioner of 1.5 / 2.0 Ton capacity including jointing compressor, capillary, replacement of reverse valve, copper tubing as required and testing the compressor complete all as specified and directed.
S&F in replacement new compressor to split type air conditioner of 1.5 / 2.0 Ton capacity including jointing compressor, capillary, replacement of reverse valve, copper tubing as required and testing the compressor complete all as specified and directed.
S&F in replacement copper tubing for split type air conditioner of 3/8" dia of required length complete all as specified and directed.
M&L for charging of air conditioner of capacity 1.5/ 2.0 TR with R-22/ R-32 gas on site including replacement/ filling of compressor oil of approved make and testing on full load for 24 hrs continuously complete all as specified and directed.
Taking out existing unserviceable fan motor of capacity 1/8 HP from the window/ split type air conditioner by dismantling the motor and taking out old burnt copper winding with and including M&L for rewinding the blower motor with similar size of super enameled copper winding wire of make: HTP/ Devidayal after providing 'E' class insulation material including replacement of rubber pad, MS clamps, nuts, bolts and varnishing including refixing the motor and testing complete all as specified and directed.
S&F in repairs switch piano type, 240 volts, singe pole, one way, 5 Amps and fixed in desert coolers complete all as specified and directed.
S&F in repairs single pole and neutral enclosure with two pin and earth, plug and socket, single phase, 240 V with & including 1 No single pole MCB, capacity 20 Amps, `C` charactristic, breaking cap 10 KA and industial plug top complete all as specified and directed.
S&F in replacement PCB unit of window type AC of existing make complete all as specified and directed.
S&F in replacement PCB unit of split type AC of existing make complete all as specified and directed.
S&F in replacement condensor coil of window type AC of 1.5 TR capacity of any make complete all as specified and directed.
S&F in replacement condensor coil of split type AC of 1.5 TR capacity of any make complete all as specified and directed
S&F of running capacitor, 36 MFD suitable for AC's complete all as specified and directed.
S&F of over load protector for AC's complete all as specified and directed.
S&F of starting capacitor, 100 - 120 MFD suitable for AC's complete all as specified and directed.
S&F of starting relay box type 1/8 HP suitable for AC's complete all as specified and directed.
S&F of plastic front show grill with air filter suitable for AC's complete all as specified and directed.
Taking out existing unserviceable fan motor of capacity 1/8 HP from the desert coolers by dismantling the motor and taking out old burnt copper winding with and including M&L for rewinding the blower motor with similar size of super enameled copper winding wire of make: HTP/ Devidayal after providing 'E' class insulation material including replacement of bushes, name pad and varnishing including refixing the motor and testing complete all as specified and directed.
S&F in replacement new tulu pump (water pump), 1/20 HP, 230 Volts, 50 C/S, single phase and making necessary connections complete all as specified and directed.
S&F in replacement new fan motor, 1/8 HP, 230 Volts, 50 C/s, single phase for desert coolers complete with MS clamps and rubber pads and making necessary connections complete all as specified and directed.
S&F in replacement of front show grill made of PGI sheet of 20 gauge duly spray painted for desert coolers complete all as specified and directed.
S&F in replacement of side shutters (set of 3) made of PGI sheet of 20 gauge with pad sporting frame duly spray painted for desert coolers complete all as specified and directed.
S&F in replacement of capacitor 4 MFD, 230 volts 50 c/s of desert coolers complete all as specified and directed.
S&F in replacement of 3 way PVC distributer of desert coolers complete all as specified and directed.
S&F in replacement new steel blades of standard quality as per existing size for desert coolers complete all as specified and directed.
Taking out existing serviceable fan motor and tulu pump from the deteriorated body of desert cooler carefully with and including S&F of new desert cooler body made out of PGI sheet 18 gauge duly spray painted including shutters, front show grill made out of GI sheet, wooden wool pad and refixing the fan motor and tulu pump therein and testing complete all as specified and directed.
M&L for cleaning of dust, rust etc. and preparation of both inside and out side surfaces of old painted desert cooler body at site and applying one coat of approved quality synthetic enamel paint with spray gun complete all as specified and directed.
S&F of PVC water pipe 15 mm dia and 3 mtr in length for water coolers complete all as specified and directed.
S&F in replacement new supporting legs as per existing size of fan motor and fixed with screws complete all as specified and directed
S&F in replacement of wood wool pad with supporting wire mesh (set of three) and fixed in pads of water coolers complete all as specified and directed.
S&F in repairs PVC sheathed copper cable, 3 core of size 70/ 00.0076 and making connections complete all as specified and directed.
M&L for servicing/ maintenance of reverse osmosis (RO)/ Aqua guard with and including repair work as required, renewal/ replacement of all filters and defective spare parts if required for its smooth functional complete all as specified and directed.
Deduct Schedule of credit (calculation will be done off line) Rs.123715.00
UMESH ENTERPRISES (BID ID -3482557)
Shri Sai Enterprises (BID ID -3485837)
MODI CORPORATION (BID ID -3485101)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.20 MB
TENDER_DOCU_8458.pdf
Tender Documents • 0.83 MB
CREDIT8458.pdf
Additional Documents • 0.16 MB
BOQ_827356.xls
BOQ • 0.65 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .