Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.9 LAccepted-AOC 301 CHAMUNDA ENCLAVE PLOT NO 89 AIROLI SECTOR 8A NAVI MUMBAI 400 708 | THANE | MAHARASHTRA | 400708 | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹24.9 L+₹1.5 L (6.41%)Rejected-Finance | L2 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 3 | L3₹26.0 L+₹2.6 L (11.1%)Rejected-Finance | L3 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 4 | L4₹26.4 L+₹3.0 L (12.9%)Rejected-Finance | L4 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 5 | L5₹27.0 L+₹3.6 L (15.4%)Rejected-Finance RC MINTRI ROAD KALIMPONG 734301 WB | KALIMPONG | KALIMPONG | WEST BENGAL | 734301 | L5 | Rejected-Finance HIGHER THAN L1 BIDDER |
Tender Value
Refer Docs
EMD Value
₹42,000
Closing Date
3 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE
HQ 136 WORKS ENGRS
SPECIAL REPAIR TO BLDG NO P-34 AT ALGARAH UNDER GE 867 EWS
2020_MES_385788_1
CWE/136 WE/54/of 2020-21
Open Tender
Civil Works
Item Rate
182 days
KALIMPONG
Class E, Category a (i)
8 documents required · 8 mandatory
₹500
GE 867 EWS
₹42,000
Yes
9 Dec 2020
13 Oct 2020
4 Nov 2020
13 Oct 2020
3 Nov 2020
27 Oct 2020
13 Oct 2020 - 20 Oct 2020
60 days
Amount
Dismantling of plain or corrugated steel sheeting any gauge and thickness including Nanital or similar pattern roof covering complete all as specified and directed.
S&F pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws all as specified and directed.
S&F pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.4mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws all as specified and directed.
M&L prepration of old painted steel surfaces of any description, not otherwise described, over 10cm width and applying one coat of synthetic enamel paints all as specified and directed.
Preparation of new painted steel and iron surfaces of any description and in any position over 10 cm width or girth as in roof not other wise specially described and applying one coat of synthetic enamel paint over a coate of red oxide primer zinc chrome all as specified and as directed.
M&L prepration of old painted wooden surfaces of any description, not otherwise described, over 10cm width and applying one coat of synthetic enamel paints all as specified and directed.
Dismantling of wrought iron or mild steel work of any description not other wise specifically provided for complete all as specified and directed.
S&F roof trusses, framed trussed, purlins, crane gantries, rails and fastening and heavy brackets framing (Beam, tee, angle channel or flat section) incl distance pieces, cleats, nut and bolts conforming to FE-410w (grade 250-E quality A) all as specified and directed.
Dismantling timber scantlings 40 Sqcm and over in section, in any position (framed work) all as specified and directed.
M&L well seasoned second class hard wood timber scantling in timber framed work; fixed in clean sawn complete all as specified and directed.
M & L preparing surfaces of wood & wood based materials new or old of any dessiption & girth not other wise described and treated with two coats of creosote oil all as specified and directed.
Dismantling of wall and celling boards (fiber pulp insulation etc) or insulation boards/slabs/blankets any thickness, including cover fillets all as specified and directed.
S&F for GI frame work for seamless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall and screws at 450 mm centre/ intermediate channel 0.9mm th having two equal flanges of 15mm each and web of 450 mm suspended from soffit at approx 900mm centre to centre with GI cleats and steel steel expansion fasteners with and incl ceiling section (n.exc 1.2 mtr length) of 0.55mm thickness having kurled web of 50 mm and flange of 26 mm each eith lips of 10.5 mm fixed to intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre size of grid 605 x 605 mm incl using of 0.9 mm MS wires as hangers complete all as specified and directed.
S&F PVC insulation 10mm panels with EPS stuck 1mm printed sheet and thickness of PVC insulation panel is 10mm sutibley placed in false ceilin grid made of aluminum/GI/MS/Wooden all as specified and directed.
S&F Solid PVC Wall Lining consisting of 5mm thick wood grain printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per pecifications and drawing all as specified and directed.
Demolition of brick/ concrete block/ stone boulder masonery walling built in Cement mortar of any description complete all as specified and directed
M & L Brickwork with fly ash bricks,straight or curved on plan exc 6m mean radious, built in CM 1: 6 complete all as specified and directed.
Taking down cement plaster of any description from stone walls incl raking out joints hacking for key, scrubing down with water etc all as specified and directed.
M&L 15 mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:6 on internel wall all as specified and directed.
M & L 15mm thick rendering on fair faces of brick work concrete surface in CM 1:4 on externel wall with water proofing compound all as specified and directed. Note : WPC will be measured and paid separately.
Supply only integral water proofing compound all as specified and directed.
M&L for two coat of cement base paint over a coat of primer incl preparation of newly plastered surfaces all as specified and as directed.
M&L for two coats of old bound distemper over a coat of priming coat on newly prepared wall surfaces, including 3 mm thick layer of wall care putty all as specified and directed.
Taking down chowkats frames but with shutters (with out taking off shutter from the frames) exc 1.5 sqm but not exc 4.00 sqm each all as specified and directed.
Taking down chowkats frames but with shutters (with out taking off shutter from the frames) n.exc 1.5 sqm each all as specified and directed.
S&F steel window (with fly froof) with side hung shutter, incl projecting type hinges with steel handle, and steel peg stay, complete with glazing bars,dovetailed or welded all as specified and directed.
M&L for Mild steel work as in guard bars for window frames, L or T section supports for sheleves etc.and similar articals confirming to FE-290 GDE E-165 all as specified and directed.
S & F 3.0 mm thick sheet glass ordinary quality and glazing with oil putty in square n.exc 0.50 Sqm in each pane all as specified and directed.
S & F galvanished mild steel wire cloth 0.63 mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or galvanished wire staples as in any position all as specified and directed.
S&F Pressed steel frames of size 125x60 mm for door with one or more rebates including necessary fixing lugs, hings, lock strike plate etc., complete all as specified and directed.
S & F 30mm thick flush door shutters , solid core construction with black board core and plywood face panels,commercial type on both face complete all as specifiedhard & fitted to chowkats and as directed.
S & F 30 mm thick 2nd class hard wood glazed and skeleton shutters open rebated and prepared to receive glass gauge etc with cut and mitred beads for securing glass etc size of member of shutter as specified in SSR Pt-1 section 8 and clause 8.24 (a) and as directed.
S&F 200mm size aluminium anodised barrel tower bolts of extruded sections all as specified and directed.
S & F 150mm size aluminium handle cast type anodised all as specified and directed.
S & F 250 mm long aluminium alloy, anodised sliding door bolt with hasp and staple (bolt type ) and fixing clip of sheet cost or extruded section or cost aluminium alloy & fixed all as specified and directed.
S&F 20mm dia tubler towel rail / curtain rod brass chromium plated with fixing brackets, stops rollers etc complete all as specified and directed.
S&F 20mm dia brackets for towel rail/ curtain rod brass chromium plated etc complete all as specified and directed.
M&L prepration of newly wooden surfaces of any description and applying two coats of synthetic enamel paints over one coat of pink primer incl prepration of surfaces complete all as specified and directed.
Demolition of cement concrete(Unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level) all as specified and directed.
M & L 75mm thick PCC 1;3;6 type C-2 (40mm graded stone aggt) in plinth protection laid to slope of 1 in 12 and finishing cement concrete suraface even and smooth without using extea cement with and including all necessary form work to divide the area in panel, finishing exposed edges fair or rounding or chamfered of exposed edges and providing 6mm thick joints therough the thickness of plinth protection duly filled mastic filling of one part of hot bitumen 85/25 grade and three part of fine sand complete all as specified and directed.
Forming construction joint (dummy) joints 65mm deepx 10mm wide filled with sealing compound grade A all as specified and directed.
M&L 40 mm thick Plain cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in floors finished even and smooth using extra cement all as specified and directed.
M&L non skid ceramic coloured tiles 7 to 8 mm thick (Square/Rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in floors etc, set and jointed in neat cement slurry and pointed with coloured cement to match over and incl 15mm thick screed bed in cm 1:6 in flooring complete all as specified and directed.
M & L glazed ceramic coloured tiles 300 x 200 x 7 mm thick, in vertical surfaces set and jointed in neat cement slurry and pointed in coloured cement to match over and incl 10mm thick screed bed in cm 1:4 in dados/skirting complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 75 mm thick as in sub base complete all as specified and directed.
M&L chequred cement concrete tiles 300x300x 25mm thick with glosey finish set and jointed and pointed in neat cement slurry with gray cement and pigment over and incl 20 mm thick screed bed complete all as specified and directed.
Demolition of reinforced cement concrete of any descreption and in any position above or below ground level all as specified and directed.
M&L Reinforced cement concrete 1:2:4, typeB-1 (20mmgraded stone agg) in lintel bends, cill beams cantilever and similar works complete all as specified and directed
Formwork to sides and siffits of floor or roof beams beams hunching ,gireders, lintles, cantilevers, shelves incl supports overhung etc also splays between floor and beams, etc all as specified and directed.
M&L for mild steel deformed TMT bars 10 mm dia and over cut to length bent to shape required including cranking bending spirally etc and binding with M.S. wire (annealed) not less than 0.9 mm dia all as specified and directed.
M&L for mild steel deformed TMT bars 5 mm dia and over in stirrups, spacers and binders,cut to length bent to shape required including cranking bending spirally etc and binding with M.S. wire (annealed) not less than 0.9 mm dia all as specified and directed.
M&L for plain cement concrete (1:3:6) type C2 (using 40mm graded stone aggregates) as in surface channels & drain all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement,incl forms,moulds,mitred/stop ends etc all as specified and directed.
Taking down carefully copper/ aluminum point wiring (light, fan, socket or power) complete (fittings such as switches, ceiling roses, pendants, regulators, sockets etc to be measured separately) (except tube light fittings) removing the materials and making good disturbed surfaces of wall/floor etc.all as specified and as directed.
Taking down Aluminium sub main wiring and making good disturbed surfaces to match with the existing surface roof/wall/floor complete all as specified and as directed by the Engr-in-Charge.
M&L for point wiring with 1.5 Sqmm (nominal area) PVC insulated un - sheathed single core multi stranded copper conductor FRLS cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC casing and capping 25 mm size, medium grade with all necessary fittings, surface wiring , for one light point /bell point/fan point controlled by one switch including 1.5 Sq mm PVC insulated copper multi stranded conductor for earth continuity conductor including closed recessed with screws (openable) for mounting and housing switches", socket, fan regulator etc. with 3 mm thick laminated bakelite sheet cover for housing switches, socket outlet, regulator etc. complete all as specified or directed including testing on completion. Note:- Proper colour coding of PVC insulated copper wire should be maintained as Red/yellow/blue wires for phases, black wire for neutral and Green wire for earth.
One light/fan/bell/exhaust fan point controlled by one switch.
One 5 pin 5 Amp switch socket out let point on an independent board.
One 5 pin 5 Amp socket out let point controlled by one switch on same board.
All as per item 56.00 here in before but for one 15 Amp 6 Pin switch socket out let independent with 2.5 Sqmm FRLS unsheathed copper conductor single core multistranded complete all as specified and directed.
M&L for sub main wiring with two single core 4 Sqmm FRLS copper conductor PVC unsheathed cable medium grade including PVC casing caping 25 mm size with accessories for sub main connection including 4 Sqmm FRLS insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly all as specified and directed. ( Note :- Three runs of 4 sqmm FRLS copper conductor shall be measured as one unit length).
S&F switch piano flush type 5 Amp single pole one wayall as specified and directed.
S&F switch socket combination multipurpose 2 in one in 5 amp and controlled by one 5 amp switch flush type all as specified and directed.
S&F switch socket combination multipurpose 3pin 5 Amp and 3pin 15 Amp controlled by one 15 amp switch flush type all as specified and directed.
S&F Ceiling rose, PVC polycarbonate body surface bakelite, 65 x 50 mm, three terminals mounted on PVC rectangular box all as specified and directed.
M & L for replacement of lamp holder,PVC/ Polycarbonate type insulated body with back plate batten/ angle type for batten fittings complete all as specified and directed.
S & F in replacement Regal batten box type suitable for LED T-8 lamps , connector block, bipin holder,PVC square block etc. complete with all accessories internally pre wired and connecting up with PVC insulated , PVC sheathed twisted flexible copper conductor cable complete all as specified and directed. Make: (Crompton cat part No. IGP131LT8-16, or equivalent model of Philips/Wipro/Bajaj as approved by GE.
S & F in replacement energy efficent linerar LED tube light T8 tubular lamp with extruded aluminium body, PC diffuser and with inbuilt driver of 1 x 20 watt Ultra bright LED Tube light with very high efficacy suited for installation in box type batten complete all as specified and directed. ake: (Crompton cat part No.LTT8-20, or equivalent model of Philips/Wipro/Bajaj as approved by GE.
Disconnection and taking down main switch, DB’s any type of capacity including MCB, MCCB, Isolator etc.complete all as specified and directed.
S&F sheet metal enclosure factory fabricated for MCB distribution board SPN 240 Volt 8 way with 200 Amp rated bus bar having IP-42 protection and double metal door concealed in wall including connection with copper thimbles as required complete all as specified and directed.
S&F MCB SPN 40 Amp 240 volt complete all as specified and directed.
S&F MCB single pole 6 to 32 Amp 240 Volt 'B' curve 10 KA complete all as specified and directed.
Earhing complete with galvanized steel earth plate electrode 600X600X6.3mm buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5m below ground level, connected to galvanized earth lead wire 4 mm , by means of galvanized iron or steel bolts, nuts, check nuts and washers, and conneced to equipments as directed, including funnel with GI med grade watering pipe 20 mm bore, wire mesh charcoal or coke and common salt in alternate layers, of 15 cm compacted thickness all around the earth electrode, with factory made cast iron cover with frame and earth lead handle protection including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc.50m and necessary testing complete all as shown on electrical plate no.5 of MES SSR Part I and as directed.
Taking down house service brackets, any type and removing the materials and making good disturbed surfaces of wall/floor etc.all as specified and as directed.
Taking down Aluminium service cable complete all as specified and as directed by the Engr-in-Charge.
Supply, Laying, commissioning and testing of UG LT cable XLPE insulated screened PVC bedded, galvanized steel strip armored, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 sqmm 2 core all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and n.exe 1.5 mtr depth including getting out all as specified and directed.
Returning filling in including spreading, leveling ,and well ramming, in layers not exceeding 25 cm each layer of any kind of soil all as specified and directed.
Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point all as specified and directed.
M & L sand filling in-trenches with clean dry sand unwashed including gently punning around cables complete all as specified and directed. Note:-punned thickness only measured for payment.
Material and labour for old size brick well burnt, laid flat, for cable protection complete all as specified and directed.
Material and labour for of GI tubing Light grade, complete with all fittings as required for passing through cables under the floor ,along the wall or along the pole with suitable size M.S.flat iron clamps incl nut,bolt and washer of 40 mm bore complete all as specified and directed.
Note:- The contract sum shall be arrived at after deducting amount of schedule of credit from the total quoted amount.
SUNIL PRADHAN
GEETA CONSTRUCTION
SANJAY MITTAL
C. M. AGARWAL AND CO
KAMLESH ENTERPRISE
M/S S. S CHETTRI AND SONS
BIJAY MITTAL
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .