Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 LAccepted-AOC | L1 | Accepted-AOC 1st lowest | |
| 2 | L2₹1.9 L+₹5,074.34 (2.68%)Rejected-Finance | L2 | Rejected-Finance 2nd Lowest | |
| 3 | L3₹2.2 L+₹27,989.76 (14.8%)Rejected-Finance | L3 | Rejected-Finance 1st Lowest | |
| 4 | L4₹2.2 L+₹28,034.60 (14.8%)Rejected-Finance | L4 | Rejected-Finance 4th Lowest | |
| 5 | L5₹2.3 L+₹37,556.59 (19.8%)Rejected-Finance CAMP AT SHADIPUR SRI VIJAYA PURAM | L5 | Rejected-Finance 5th Lowest |
Tender Value
₹2.3 L
Closing Date
24 Feb 2022, 11:00 amClosed
Deputy Conservator of Forests
Silva Complex, Horticulture Road, Haddo
Construction of permanent watchman shed at the entrance of Silva Complex at Haddo under Silviculture Division Haddo.
2022_DCFSL_5195_1
Silva/G-392/660
Open Tender
Construction Works
Works
30 days
Silva Complex, Horticulture Road, Haddo
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
Exempted
28 Apr 2022
17 Feb 2022
24 Feb 2022
17 Feb 2022
24 Feb 2022
18 Feb 2022
Amount
Earth work in excavation by mechanical means (Hydraulic Excavator)/ Manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m. All kind of soil for Foundation & Plinth Beam
Filling available excavated earth (excluding rock) in trenches plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50m and lift upto 1.5m for foundation
Suppling and filling in plinth with local sand under floors including, watering, ramming consolidating and dressing complete. (Footing, plinth beam & Floor)
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering all work upto plinth level: 1:4:8 (1cement: 4coarse sand : 8 graded stone aggregate 40mm nominal size) for footing, plinth beam & Floor
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering all work upto plinth level: 1:2:4 (1cement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size) for footing, pedestal, short column & Plinth beam
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering all work upto plinth level: 1:3:6 (1cement: 3 coarse sand(zoneIII) : 6 graded stone aggregate 20mm nominal size)
Reinforced cement concrete in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc upto floor five level excluding cost of centring, shuttering, finishing & reinforcement: 1:1.5:3(1cement: 1.5 coarse sand(zoneIII) : 3 graded stone aggregate 20mm nominal size) for Column & Tie Beam
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement with 1:2:4 (1cement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size) for Lintel beam & Sill beam
Centring and shuttering including strutting, propping etc and removal of form for: Foundations, footings, bases of columns etc. for mass concrete of footing and pedastal
Centring and shuttering including strutting, propping etc and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers of Sill beam, Lintel beam & Tie beam
Centring and shuttering including strutting, propping etc and removal of form for Columns, Pillars, Piers, Abutments, Posts & Struts
Providing and fixing up to floor five level precast cement concrete hollow block including hoisting & setting in position with cement mortar 1:3 (1cement :3 coarse sand), cost of required centring, shuttering complete 1:3:6 (1cement: 3 coarse sand(zoneIII) : 6 graded stone aggregate 20mm nominal size) for (400 x 200 x 150) Front wall , back & Side wall, Back wall
Steel reinforcement fo RCC work including straightening , cutting, bending, placing in position and binding all complete upto plinth level: Thermo- Mechanically Treated bars of grade Fe 500D or more for Jali 10mm dia 100 mm c/c, 4 No- 12mm dia (plinth + Tie Beam), 8mm dia stirrups, 100mm c/c, 12mm dia column & 8mm dia stirrups, 100 mm c/c
Providing and fixing aluminium work for doors, windows and partitions withtextured built up standard tubular section/ appropriate Z section and other section of approved make confirming to IS: 733 & IS:1285, fixing with dash fastenders of required dia and size, including necessary filling up the gap at junctions, i.e at top bottom and sides with required EPDM rubber/neoprene gasket etc, wih smooth aluminium section and jointed mechanically with cleat angle, C. P. brass/ stainless steel screws fitted with the float glass pans of 4mm thickness for window (sliding) and Door
Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete Window 7mm (100X 100 mm Gap)
Providing and fixing powder coated aluminium work (minimum thickness of powdre coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS:733 in frames of false ceiling including aluminium angle cleats with necessary C.P. Brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I level adjusting hangers 6mm dia. with necessary cadmium plated machine screws all complete as per approved drawing "L" angle (2.5mm thick 1 1/2" x 1 1/2" ) and "T" angle (2.5mm thick 1 1/2" x 1" )
Providing and fixing plain Multipurpose Cement board (High Pressure steam cured) as per IS; 14862, with suitable screws for fibre cement board in ceiling etc complete 6mm thick cement board
Providing and laying rectified Glazed Ceramic floor tiles of size 300 X 300 mm or more (thickness to be specified by the manufacturer) of 1st quality conforming to IS: 15622, of approved make, in colours White, Ivory Grey, Fume red Brown, laid on 20 mm thick cement mortar 1:4 (1cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc complete.
12mm cement plaster of mix 1:4 (1 cement : 4 fine sand) for Outer front wall, Both side wall , back wall , inner front wall, Both side wall & back wall
Making plinth protection 50mm thick of cement concrete 1:3:6 (1cement : 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) over 75 mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.
Steel work in built up tubular (round, square or rectangular hollow tubes etc) trusses etc including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc complete Hot finished welded type tubes for main truss top rafter 50mm dia Bottom tie beam 50 mm dia , 32mm dia vertical & cross, Main bottom runner 32mm dia, Top Tie runner 32mm dia, 12mm thick plate, above column , Jointing Truss Tie runner, Nut & Bolt 10" & 3"
Providing and fixing precoated galvanised iron profile sheets 0.50mm + 0.05%, total coated thickness with zinc coating 120 gsm as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyster top coat 15-18 microns. Sheet should have protective guard film of 25micron minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre. The sheet shall be fixed using self drilling/ self tapping screws of size (5.5 x 55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 0.05% total coated thickness, Zinc coating 120 gsm as per IS:277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete for Ridges plain (500-600 mm)
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: water thinnable cement primer for outer front wall, Both side wall , back wall , inner front wall, Both side wall & back wall
Finishing walls with textured exterior paint of required shade; New work (Two or more coats applied @ 3.28ltr/ 10 sqm) over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm for outer front wall, Both side wall , back wall , inner front wall, Both side wall & back wall
Painting on G. S Sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade, New work (two or more coats) including a coat of approved steel primer but excluding a coat of mordant solution
B S ENGINEERING
M/S SUNDARAM CONSTRUCTION
SONA MONA TRADERS
Shri S K Biswas
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .