Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.4 LAccepted-AOC | ₹31.4 L Quoted ₹31.7 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹40.8 L+₹9.1 L (28.6%)Rejected-Finance 403 GH MANSADEVI COMPLEX PANCHKULA 134109 HARYANA | PANCHKULA | HARYANA | 134109 | ₹40.8 L+₹9.1 L (28.6%) | L2 | Rejected-Finance Rejected due to bidder not L1 |
| 3 | L3₹41.1 L+₹9.4 L (29.7%)Rejected-Finance HOUSE NO 49 SECTOR 28 FARIDABAD 121008 HR | FARIDABAD | FARIDABAD | HARYANA | 121008 | ₹41.1 L+₹9.4 L (29.7%) | L3 | Rejected-Finance Rejected due to bidder not L1 |
| 4 | L4₹41.4 L+₹9.7 L (30.6%)Rejected-Finance | ₹41.4 L+₹9.7 L (30.6%) | L4 | Rejected-Finance Rejected due to bidder not L1 |
| 5 | L5₹41.5 L+₹9.8 L (31.1%)Rejected-Finance | ₹41.5 L+₹9.8 L (31.1%) | L5 | Rejected-Finance Rejected due to bidder not L1 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
26 Mar 2020, 6:00 pmClosed
GE 865 EWS
GE 865 EWS
REPAIR REPLACEMENT OF FILTERS V BELT AND SERVICING OF DG SETS AT SECTOR A UNDER GE 865 EWS LEH
2020_MES_330247_2
865/EWS-123/2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 865 EWS
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE 865 EWS
₹80,000
Yes
25 Apr 2020
4 Mar 2020
28 Mar 2020
4 Mar 2020
26 Mar 2020
18 Mar 2020
Amount
Disconnecting electric connections from alternator and fuel connection from engine decoupling of engine and alternator for repair, strip opening and de-assembling of engine for repair including dismantling of radiator, radiator fan, water pump assembly, air cleaner, rocker cover housing rocker, taking out piston and piston assembly, CR bearing, inlet and exhaust valve by opening nuts bolts including wiring of stare assembly if required, of DG set 280 KVA, engine Make: Greaves and replacement of old defective spare parts with new spare parts under serial under item No-18 here in after, including any type of machine work required at site/ workshop to compete the repair including complete servicing the engine all as required at site, re-assembling the engine in existing position complete and testing on completion all as specified and as directed by Engineer-In-Charge. Note: (a) New spare parts will be measured and paid separately as supply only under the respective items. (b) Cost of cleaning, welding, minor repair and special tools and plants required for dismantling engine will deemed to be included in quoted rates.
Supply only following new spare parts required for repair of DG Set 280 KVA :-
Piston assembly.
Piston ring set.
Valve exhaust.
Valve seat exhaust.
Valve inlet.
Valve seat inlet.
Valve guide.
Valve steam seal.
Set of fuel pipe.
Set of hose pipe.
Oil seal.
Coupling assembly (FIP).
Connecting rod bush.
Connecting rod bearing.
Cam bush.
Tecko cable for meter.
Turbo charger assembly.
Cylinder liner assembly.
Hose pipe set complete with clamps.
Main bearing
Thrust ring.
Piston cooling nozzle.
Cylinder head gasket.
Cogged belt.
V- Belt.
Cylinder head.
Big end bearing.
Oil pressure gauge.
Hour cum RPM metre.
Calibration of PT pump of 280 KVA DG Set including replacement of PT pump kit, gear gasket etc and other required spare parts, for smooth functioning of DG set, complete all as specified and as directed by Engineer-In-Charge.
Repair, calibration, checking and pressure testing of fuel injectors assembly including replacement of damaged/ defective parts, cups, barrel and washers and testing whole assembly after necessary repair and fixing in engine of 280 KVA DG Set, complete all as specified and as directed by Engineer-In-Charge.
Repair to Head assembly by cutting, grinding, polishing and facing of cylinder head including replacement of cylinder head sets and minor repairs to cylinder head of 280 KVA DG Set, complete all as specified and as directed by Engineer-In-Charge.
Cleaning of radiator using ‘K’ oil and radiator cleaning solution hydraulic acid by pressure of pump and brush and necessary welding whichever is required for cleaning of 280 KVA DG Set, complete all as specified and as directed by Engineer-In-Charge.
Repair to Crank Shaft assembly by grinding, polishing including required material, tools and plant of 280 KVA DG Set, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable self starter assembly with new self starter assembly, suitable for DG set of 280 KVA, complete all as specified and as directed by Engineer-In-Charge.
Supply and Replacement of Oil seal front and rear suitable side for following Capacity DG Sets Make Kirlosker/ cummins/Greaves complete all as specified and directed by Engr-in-Charge.
500 KVA Kirloskar complete all as directed.
280 KVA Kirloskar complete all as directed.
160/140/125/110 KVA Greaves complete all as directed.
Supply and Replacement of CR bearing of following DG Sets make Kirlosker/ cummins/Greaves complete all as specified and directed by Engr-in-Charge.
500 KVA Greaves complete all as directed.
280 KVA Kirloskar complete all as directed.
160/140/125/110 KVA Greaves/kirloskar complete all as directed.
63 KVA Kirloskar complete all as directed.
Supply and Replacement of battery terminal for DG Sets complete all as specified and directed by Engr-in-Charge.
Supply and Replacement of Exhaust Spring Belowfor the following DG Sets complete all as specified and directed by Engr-in-Charge :-
750 KVA cummins complete all as directed.
500 KVA Kirloskar complete all as directed.
500 KVA Greaves complete all as directed.
280 KVA Greaves complete all as directed.
160 KVA Kirloskar complete all as directed.
140/125/110 KVA Greaves complete all as directed.
Supply and Replacement of rubber Hose pipe with suitable size of clamps both side for the following DG Sets complete all as specified and directed by Engr-in-Charge :-
750 KVA cummins complete all as directed.
500 KVA Kirloskar complete all as directed.
500 KVA Greaves complete all as directed.
280 KVA Greaves complete all as directed.
160 KVA Kirloskar complete all as directed.
140/125/110 KVA Greaves complete all as directed.
63 KVA Kirloskar complete all as directed.
Supply and Replacement of oil pump for the following DG Sets complete all as specified and directed by Engr-in-Charge :-
750 KVA cummins complete all as directed.
500 KVA Kirloskar complete all as directed.
500 KVA Greaves complete all as directed.
280 KVA Greaves complete all as directed.
160 KVA Kirloskar complete all as directed.
140/125/110 KVA Greaves complete all as directed.
63 KVA Kirloskar complete all as directed.
Supply and Replacement of Oil sensor for the following DG Sets complete all as specified and directed by Engr-in-Charge :-
750 KVA cummins complete all as directed.
500 KVA Kirloskar complete all as directed.
63 KVA Kirloskar complete all as directed.
M & L for Rewinding of burnt windings of Exhaust fans from DG Sets of size 400-450 mm size including dismantling from loc and removing the burnt out winding , cleaning the stator with CTC solution to remove the burnt slots. Rewinding the same with new super enamelled copper wire same gauge and size /number of turns , varnishing the winding completely and reassembling completely.
Servicing of primary coolent circulating pump for 500 to 750 KVA make:Kirloskar/Cummins/Greaves/Perkins all as specified and directred by Engr-in-Charge.
Repair and servicing of scilensor/exhaust manifold for 500 to 750 KVA make:Kirloskar/Cummins/Greaves/Perkins all as specified and directred by Engr-in-Charge.
Repair and servicing of scilensor/exhaust manifold for 280 to 500 KVA make:Kirloskar/Cummins/Greaves/Perkins all as specified and directred by Engr-in-Charge.
Repair and servicing of scilensor/exhaust manifold for 160 to 62.5 KVA make:Kirloskar/Cummins/Greaves/Perkins all as specified and directred by Engr-in-Charge.
Supply and fixing battery cable of copper conductor multistranded RED and BLACK colour 2mtr long 21sqmm for connection to self starter unit to Battery unit complete.
Supply, Laying, jointing and testing PVC insulated armored heavy duty electric cable with aluminum conductor, 1100 volt grade, cross sectional area 120 Sqmm 3.5 Core. Make- Gloster/Paragon/Havells
Supply, Laying, jointing and testing PVC insulated armored heavy duty electric cable with aluminum conductor, 1100 volt grade, cross sectional area 185 Sqmm 3.5 Core. Make- Gloster/Paragon/Havells
Material & labour for Chemical earthing complete with copper plate electrode 900mm x 600mm x5mm burried directly in ground vetically to a depth not less than 4.70 mtr below normal ground level (with top edge of earth plate not less than 3.60 mtrs below ground level ) connected to copper strip 32 mm x 6 mm as main earthing lead by means of tinned copper/ brass bolts nuts checknuts, and washers besides brazing ( copper strip shall be 0.5 M overlaped with copper plate by brazing) at all joints all as directed and connected to earth test point all as specified and testing on completion with and including necessary excavation and earth work in any type of soil earth,GI pipe medium grade 50 mm bore for protection of copper strip from earth electrode to and including the earth test point of galvanised Iron/steel , adequate quality of charcoal dust, common salt and magnesium sulphate in alternate layers of 100 mm thick x 6 layers all around the plate , and RCC cover of size 54x54x50 mm (1:2:4) type B1 using 20 mm graded crushed stone aggregate reinforced with 8 mm dia TMT bars @ 75mm C/C both ways with mild steel handle 12 mm dia, PGI funnel with wire mesh, 20 mm dia GI pipe light grade for watering all as shown in drawing Note - 1. Cost of copper strip and GI protection pipe up to a distance 7.5 M shall be included in quated rate of above Items. 2. On testing,after completion of job ,if desired earth resistence is not found i.e. below 1.00 Ohms ,the earthing shall be redone on no extra cost to govt.
Replacement of 'V' belt for water pump suitable for following capacity DG Sets make Kirloskar/Cummins/Greaves complete all as specified and directed by Engr-in-Charge.
750 KVA cummins complete all as directed.
500 KVA Kirloskar complete all as directed.
500 KVA Greaves complete all as directed.
280 KVA Greaves complete all as directed.
160 KVA Kirloskar complete all as directed.
110/125/140 KVA Kirloskar complete all as directed.
63 KVA Kirloskar complete all as directed.
(h) 62.5 KVA Ruston complete all as directed.
Supply and fixing in replacement off load changeover switch 630 Amps, 4 pole in sheet metal enclosure, side /front handle operated, cat No IHCFFE0630 Make-Havells or equivalent of L&T/Legrand complete all as secified and directed
EESSI
M/S Behl Sons
M/S AMCO INDUSTRIES AND EXPORT CORPORATION
H R CONSTRUCTION
ASHOK KUMAR SHARMA
M/S MALIK CHAND SIRI RAM
MEDHI ALI GRONGPA
M/S STANZIN NOBROO
HONY CAPT RIGZIN SAMPHEL
N K Gupta Builders Pvt. Ltd.
ESS AAR ENTERPRISES
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .