Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.1 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹9.2 L+₹5,267 (0.58%)Rejected-Finance VILL ADHARMANIK P O BASUDEVKHALI P S BERHAMPORE DIST MURSHIDABAD | BERHAMPORE | MURSHIDABAD | WEST BENGAL | 742101 | L2 | Rejected-Finance 2nd Lowest | |
| 3 | L3₹9.2 L+₹10,975 (1.20%)Rejected-Finance | L3 | Rejected-Finance 3rd Lowest |
| Sl No | Description | Qty | Unit | JASODA REFRIGERATOR SERVICING CENTRE L1 | SRIDAM MONDAL L2 | BURDWAN REFRIGARATION SERVICE L3 |
|---|---|---|---|---|---|---|
| 1.00 | Replacement of Old Unserviceable AC Machineof 230V, 50Hz, 3 star , 2.0 TR capacity Inverter , type Split Air-conditioner with 7050 watt coolining capacity ( Make- O-General Model no - ASGG24CPAA-B & AOGG24CPAA-B) or equvalent model of Hitachi/Daikin/ PWD Appvd ) with Remote , fitting accessories etc. | 9 | Each | 70,500 ₹6,34,500 Lowest | 70,680 ₹6,36,120 | 71,200 ₹6,40,800 |
| 2.00 | Distribution wiring in 1.1 KV single core stranded 'FRLS' PVC insulated & unsheathed copper wire (Finolex / Havells/ KEI / Gloster /approved by EIC) in suitable size ( 40/32/25 mm ) PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required 2 x 4 sqmm + 1 x 2.5 sqmm [for AC ] | 250 | Mtr | 184 ₹46,000 Lowest | 189 ₹47,250 | 186 ₹46,500 |
| 3.00 | Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections. | 9 | Each | 150 ₹1,350 | 145 ₹1,305 Lowest | 147 ₹1,323 |
| 4.00 | S& F laying of -(i) gauge copper pipe 5/8" 0.7 mm thick for suction .(ii) copper pipe 1/4" 0.6 mm thick for discharge (OEM make) with 9 mm thick thermal insulation foam nitrile / rubber / K Flex / Accroflex with max saddling with max 1 mtr distance both for suction & discharge pipe and mending good the holes & damages as directed by EIC(extra length for distance of ODU & IDU exceed 3 mtr.) | 90 | Mtr | 832 ₹74,880 Lowest | 834 ₹75,060 | 837 ₹75,330 |
| 5.00 | S& Laying 3 core 4.0 sqmm PVC insulated & unarmoured copper wire (make-- Finolex/Havells/KEI) for 1.5/2 Tr. Split AC machine (extra length for distance of ODU & IDU exceed 3 mtr.) with max saddling with max 1 mtr distance as per direction of EIC. | 95 | Mtr | 274 ₹26,030 Lowest | 277 ₹26,315 | 280 ₹26,600 |
| 6.00 | S& Laying 3 core 1.5 sqmm PVC insulated & unarmoured copper wire (make-- Gloster/Finolex/Havells/KEI) as per direction of EIC. | 110 | Mtr | 124 ₹13,640 | 122 ₹13,420 Lowest | 125 ₹13,750 |
| 7.00 | S & F of flexible PVC high quality water carrying pipe of proper size for draining water from already installed AC to any available (nearest) drain water pipe or near to ground level and the pipe must be properly saddled with the wall incl. proper insertion of the flexible pipe to drain water pipe and sealing the entry with required materials like PVC tape, High quality sealing the entry with required materials like PVC tape, high quality sealing gum etc. as reqd. All these arrangement for fixing must be arranged by the agency itself as per direction of EIC. | 190 | Mtr | 113 ₹21,470 Lowest | 118 ₹22,420 | 116 ₹22,040 |
| 8.00 | Dismantling the existing Window / Split type AC machine carefully from its original location & including carrying & deposited to store as instructed by the EIC. | 11 | Each | 595 ₹6,545 Lowest | 632 ₹6,952 | 637 ₹7,007 |
| 9.00 | Enclosed Safety Cage for ODU : Supplying & erection fabrication of M.S Grill guard by 10 mm x 10 mm M.S Squre bar welded and fabricated by 6" gap in the side 25 x 25 x 5 mm MS angle four side of the grillside duly welded by Co's own tools &tackles, hing 2- palla door incl. S&F of 7 lever Godrej Lock & kEY And cutting by gas cutter including S&F of MS wire net (8 SWG) with 1"x1" gap to be fixed on the grill guard incl. with necessary painting with 02 coat of R.O. primer (Asianpaint / Shalimer / Berger) incl. fixing of ODU as pr direction of EIC. [size- 6' (L) x 3'x (D) x 4' (H)]. | 12 | Each | 7,380 ₹88,560 Lowest | 7,450 ₹89,400 | 7,550 ₹90,600 |
Tender Value
Refer Docs
EMD Value
₹9,900
Closing Date
2 Jul 2024, 10:55 amClosed
AE/BMCESD/PWD
Kenduadihi, Gobindanagar Hospital campus, Bankura-722102
Replacement of Old Unserviceable AC Machine on emergency basis by 2.0 TR single Phase AC Machine at Surgery OT of Main Building under BMC and H , Bankura.
2024_WBPWD_700027_1
WBPWDTE/ AE /BMCESD /NIQ-12/ Q of 2024-25
Open Tender
ELECTRICAL WORKS ORG
Item Wise
14 days
AE/BMCESD/BANKURA
Please refer Tender documents.
3 documents required · 3 mandatory
₹9,900
Yes
7 Jul 2026
25 Jun 2024
4 Jul 2024
25 Jun 2024
2 Jul 2024
25 Jun 2024
Amount
Replacement of Old Unserviceable AC Machineof 230V, 50Hz, 3 star , 2.0 TR capacity Inverter , type Split Air-conditioner with 7050 watt coolining capacity ( Make- O-General Model no - ASGG24CPAA-B & AOGG24CPAA-B) or equvalent model of Hitachi/Daikin/ PWD Appvd ) with Remote , fitting accessories etc.
Distribution wiring in 1.1 KV single core stranded 'FRLS' PVC insulated & unsheathed copper wire (Finolex / Havells/ KEI / Gloster /approved by EIC) in suitable size ( 40/32/25 mm ) PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required 2 x 4 sqmm + 1 x 2.5 sqmm [for AC ]
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections.
S& F laying of -(i) gauge copper pipe 5/8" 0.7 mm thick for suction .(ii) copper pipe 1/4" 0.6 mm thick for discharge (OEM make) with 9 mm thick thermal insulation foam nitrile / rubber / K Flex / Accroflex with max saddling with max 1 mtr distance both for suction & discharge pipe and mending good the holes & damages as directed by EIC(extra length for distance of ODU & IDU exceed 3 mtr.)
S& Laying 3 core 4.0 sqmm PVC insulated & unarmoured copper wire (make-- Finolex/Havells/KEI) for 1.5/2 Tr. Split AC machine (extra length for distance of ODU & IDU exceed 3 mtr.) with max saddling with max 1 mtr distance as per direction of EIC.
S& Laying 3 core 1.5 sqmm PVC insulated & unarmoured copper wire (make-- Gloster/Finolex/Havells/KEI) as per direction of EIC.
S & F of flexible PVC high quality water carrying pipe of proper size for draining water from already installed AC to any available (nearest) drain water pipe or near to ground level and the pipe must be properly saddled with the wall incl. proper insertion of the flexible pipe to drain water pipe and sealing the entry with required materials like PVC tape, High quality sealing the entry with required materials like PVC tape, high quality sealing gum etc. as reqd. All these arrangement for fixing must be arranged by the agency itself as per direction of EIC.
Dismantling the existing Window / Split type AC machine carefully from its original location & including carrying & deposited to store as instructed by the EIC.
Enclosed Safety Cage for ODU : Supplying & erection fabrication of M.S Grill guard by 10 mm x 10 mm M.S Squre bar welded and fabricated by 6" gap in the side 25 x 25 x 5 mm MS angle four side of the grillside duly welded by Co's own tools &tackles, hing 2- palla door incl. S&F of 7 lever Godrej Lock & kEY And cutting by gas cutter including S&F of MS wire net (8 SWG) with 1"x1" gap to be fixed on the grill guard incl. with necessary painting with 02 coat of R.O. primer (Asianpaint / Shalimer / Berger) incl. fixing of ODU as pr direction of EIC. [size- 6' (L) x 3'x (D) x 4' (H)].
SRIDAM MONDAL
BURDWAN REFRIGARATION SERVICE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .