Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.0 LAccepted-AOC VILL KADUA PO HARIATARA DISTT PASCHIM MEDINIPUR WB PIN 721304 | HARIATARA | PASCHIM MEDINIPUR | WEST BENGAL | 721304 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹49.9 L+₹1.2 L (2.44%)Rejected-Finance VILL GAIDUA PO HARIATARA P S KHARAGPUR LOCAL DIST PASCHIM MEDINIPORE ST WEST BENGAL PIN 721 304 | MEDINIPUR WEST | WEST BENGAL | 721304 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹55.7 L+₹7.0 L (14.3%)Rejected-Finance | L3 | Rejected-Finance Not being L1 |
Tender Value
₹49.4 L
EMD Value
₹98,800
Closing Date
24 Aug 2023, 6:00 pmClosed
MAJOR AJIT CHOUDHARY
GE (AF) Kalaikunda PO Kalaikunda Air Field Dist Paschim Medinipore State West Bengal Pin 721303
REPAIR/MAINTENANCE TO CERTAIN PLUMBING AND SANITARY WORKS, PLINTH PROTECTION AND INTERNAL PERIODICAL SERVICES AND CERTAIN MISC WORKS IN TECHNICAL AREA REPAIR AND MAINTENANCE OF ANY TYPE/SIZE PIPE LINES, VALVES, STARTER, PANELS, BORE WELL AND ALLIED W
2023_MES_600688_2
C/8872/E8
Open Tender
Civil Works
Item Rate
270 days
AF STN KALAIKUNDA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF KALAIKUNDA
₹98,800
Yes
6 Nov 2023
27 Jul 2023
25 Aug 2023
27 Jul 2023
24 Aug 2023
10 Aug 2023
Amount
Taking up or down of old 25mm bore galvanised steel water tubing medium grade in walls, floors or ceilings etc including all fitting cleaning of serviceable pipe and segregating for re-use and removing unserviceable pipes from site of work complete all as specified and directed by Engr-in-Charge.
Taking up or down of old 20mm bore galvanised steel water tubing medium grade in walls, floors or ceilings etc including all fitting cleaning of serviceable pipe and segregating for re-use and removing unserviceable pipes from site of work complete all as specified and directed by Engr-in-Charge.
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth in any type of soil and getting out for taking up/laying of GI/PPR/CI pipes all as specified and directed . Note : Manual excavation to be done. During excavation if any damage occured to existing cable any type/ water pipe line, it will be contractor responsibilty to get it repair and make functional by providing jointing kit etc without any extra cost. Contractor has to repair it within 24 hrs so that essential service can not be effected due to such damage.If contractor fails to repair it within 24 hrs penalty @ Rs 500/- will be charged to contractor. In this GE decision will be final, conclusive and binding.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick all as directed
Removal of surplus soil to a distance n.exc 50 mtrs and deposited where directed at a level n.exc1.5 mtr above the starting point all as specified and directed .
Material and labour for road cutting of WBM/PCC path/road and passing the pipe line below and making the disturbed surface as per existing pattern all as directed and specified.
Taking out old unserviceable GI/PVC/PPR pipes from trenches, walls, floors, ceiling and duct etc including all fittings of 80 mm bore complete all as specified and directed by Engr-in charge. Note: Excavation/earth work will be measured and paid separately under relevent item.
All as per item No 07.00 above herein before but of size 50 mm bore all as specified and directed .
All as per item No 07.00 above herein before but of size 40 mm bore all as specified and directed .
Material and labour for laying of GI tubing 80 mm bore, medium grade, ISI marked, conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 like elbow, socket, tee, reducer, nipple, short piece, union etc as required at site and laid in trenches incl connecting with existing lines all as directed by Engr-in-charge. Note:(i) Union or long screw have to provided at starting / end point of jointing pipe line . (ii) Contractor has to submit the test certificate and purchase voucher of pipes before claiming payment.
All as per item No 10.00 above herein before but of size 50 mm bore complete all as specified and directed .
All as per item No 10.00 above herein before but of size 40 mm bore complete all as specified and directed .
Material and labour for laying of GI tubing 25 mm bore, medium grade, ISI marked, conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 like elbow, socket, tee, reducer, nipple, short piece, union etc as required at site and fixed to walls and ceiling or laid in floor incl connecting with existing lines all as directed by Engr-in-charge. Note: (i) Union or long screw have to provided at starting / end point of jointing pipe line . (ii) Contractor has to submit the test certificate and purchase voucher of pipes before claiming payment. (iii) Contractor shall provide MS/GI clamp for fixing the pipe on wall on every 60 cm without any extra cost,
All as per item No 13.00 above herein before but of size 20 mm bore complete all as specified and directed .
M&L for refixing existing old GI tubing taking down under item No.7 above here in before in new or existing position after cleaning and providing including new all fittings conforming to IS 1239 (Part-2): 2011 all as specified and directed by Eng In Charge for 50 mm bore of pipe. Note: Union or long screw have to provided at starting / end point of jointing pipe line .
All as per item No 15.00 above herein before but of size 40 mm bore complete all as specified and directed .
All as per item No 15.00 above herein before but of size 25 mm bore complete all as specified and directed .
All as per item No 15.00 above herein before but of size 20 mm bore complete all as specified and directed .
M&L for refixing existing old GI tubing taking down under item No. 7 above here in before in new or existing position after cleaning and providing including new all fittings conforming to IS 1239 (Part-2): 2011 all as specified and directed by Eng In Charge for 80 mm bore of pipe. Note: Union or long screw have to provided at starting / end point of jointing pipe line .
Material and labour for fixing GM globe/gate valve 50 mm bore with iron wheel head, screwed both ends for iron/PPR pipes, ISI marked, conf to IS including taking down old unserviceable complete all as specified and directed by Engr in charge. Make : ZOLOTO / LEADER or equivalent make Note: Union or long screw have to provided before fixing of gate valve. (ii) Contractor has to submit the test certificate and purchase voucher of valves before claiming payment.
All as per item No 20.00 above but of size 40 mm bore complete all as specified and directed
All as per item No 20.00 above but of size 25 mm bore complete all as specified and directed
All as per item No 20.00 above but of size 20 mm bore complete all as specified and directed
All as per item No 20.00 above but of size 15 mm bore complete all as specified and directed
Taking down unserviceable sluice valve/NRV/foot valve and their fitments like gasket , bolt/nuts of size 80 to 300 mm bore without damaging the valve chamber and pipe line complete all as specified and directed by Engineer-In-charge
Supply and fixing sluice valve 300 mm bore, ISI marked, as per IS 14846: 2000 , with valid CMLNo. , Batch No. and Manufacturer Serial No., class PN 1.6 with brass spindle, brass check nut, with fiber board gasket, bolts, nuts and washers for fixing the valve in position, in valve pit chambers or location as directed and specified by Engr-in-charge. Make Uphadhya / Kirloskar/ Leader Note : Contractor has to submit the test certificate and Purchase Voucher of valves before claiming the payment..
Supply and fixing sluice valve 200 mm bore, ISI marked, as per IS 14846: 2000 , with valid CMLNo. , Batch No. and Manufacturer Serial No., class PN 1.6 with brass spindle, brass check nut, with fiber board gasket, bolts, nuts and washers for fixing the valve in position, in valve pit chambers or location as directed and specified by Engr-in-charge. Make Uphadhya / Kirloskar/ Leader Note : Contractor has to submit the test certificate and Purchase Voucher of valves before claiming the payment..
Supply and fixing sluice valve 150 mm bore, ISI marked, as per IS 14846: 2000 , with valid CMLNo. , Batch No. and Manufacturer Serial No., class PN 1.6 with brass spindle, brass check nut, with fiber board gasket, bolts, nuts and washers for fixing the valve in position, in valve pit chambers or location as directed and specified by Engr-in-charge. Make Uphadhya / Kirloskar/ Leader Note : Contractor has to submit the test certificate and Purchase Voucher of valves before claiming the payment..
Supply and fixing sluice valve 100 mm bore, ISI marked, as per IS 14846: 2000 , with valid CMLNo. , Batch No. and Manufacturer Serial No., class PN 1.6 with brass spindle, brass check nut, with fiber board gasket, bolts, nuts and washers for fixing the valve in position, in valve pit chambers or location as directed and specified by Engr-in-charge. Make Uphadhya / Kirloskar/ Leader Note : Contractor has to submit the test certificate and Purchase Voucher of valves before claiming the payment..
Supply and fixing sluice valve 80 mm bore, ISI marked, as per IS 14846: 2000 , with valid CMLNo. , Batch No. and Manufacturer Serial No., class PN 1.6 with brass spindle, brass check nut, with fiber board gasket, bolts, nuts and washers for fixing the valve in position, in valve pit chambers or location as directed and specified by Engr-in-charge. Make Uphadhya / Kirloskar/ Leader Note : Contractor has to submit the test certificate and Purchase Voucher of valves before claiming the payment..
S & F flanged reflux valve (non-return) of single door, swing check type nominal pressure (PN 1.6) of preferred materials as per IS 5312 (Part 1): 2004, nominal size 150 mm complete all as specified and as directed.
Supply and laying of Centrifugally Cast (Spun) Ductile Iron Pressure Pipes with Spigot & Socket end of dia 150 mm size, Class K-9 conforming to IS: 8329/2000 suitable for (push-on) rubber gasket jointing with centrifugally applied inside cement mortar lining with Sulphur Resistant Cement and external Metallic Zinc Coating with a finishing layer of Black Bitumen coating on external surfaces suitable for treated water supply and including rubber gasket joint in any length laid in trenches, complete all as specified and as directed by Engr-in-Charge.
Supply and laying of Centrifugally Cast (Spun) Ductile Iron Pressure Pipes with Spigot & Socket end of dia 100 mm size, Class K-9 conforming to IS: 8329/2000 suitable for (push-on) rubber gasket jointing with centrifugally applied inside cement mortar lining with Sulphur Resistant Cement and external Metallic Zinc Coating with a finishing layer of Black Bitumen coating on external surfaces suitable for treated water supply and including rubber gasket joint in any length laid in trenches, complete all as specified and as directed by Engr-in-Charge.
Material and labour for fixing of Ductile Iron special fittings(Bends any type, radius an angle Tapers any type,straight, bend, increasing, decreasing or double socket etc. Tee pieces single branch, `Y' junction, double branch, cross) all socket and spigot collars type, caps and plugs up to 200 mm dia as per site requirement, complete all as specified and as directed by Engr-in-Charge.
Material and labour for fixing of Ductile Iron special fittings (Bends Tapers Tee pieces (single & double branch) any type and angle /radius and straight connecting pieces) but all ends flanged upto bore 200mm dia complete all as specified and as directed by Engr-in-Charge.
S& F in repair replacement of gasket of MS /CI/GI pipe flange joint of 150 mm dia, with new rubber or fiber board gasket including replacement of nut bolts and washer complete all as specified and directed by Eng in charge.
S& F in repair replacement of gasket of MS /CI/GI pipe flange joint of 100 mm dia, with new rubber or fiber board gasket including replacement of nut bolts and washer complete all as specified and directed by Eng in charge.
S& F in repair replacement of gasket of MS /CI/GI pipe flange joint of 80 mm dia, with new rubber or fiber board gasket including replacement of nut bolts and washer complete all as specified and directed by Eng in charge.
S& F in replacement dosing pump roller assembly suitable for existing dosing pump complete all as specified and directed by EIC . Make of roller assembly :- Declibac / Ramco or equivalent as approved by GE Note :- (i) Contractor shall bring the new roller assembly as per existing model and make ,size for replacement of u/s.. (ii) Before procurement of Roller assembly for existing dosing pump contractor shall check the suitibility of model and make ,size of new to match with existing u/s.
S& F in replacement dosing pump tube suitable for existing dosing pump complete all as specified and directed by EIC . Make of Pump Tube :- Declibac / Ramco or equivalent as approved by GE Note :- (i) Contractor shall bring the new pump tube as per existing model and make ,size for replacement of u/s.. (ii) Before procurement of Pump tube for existing dosing pump contractor shall check the suitibility of model and make ,size of new to match with existing u/s.
S& F in replacement dosing pump weighted suction line strainer suitable for existing dosing pump complete all as specified and directed by EIC . Make of Injection check valve :- Declibac / Ramco or equivalent as approved by GE Note :- (i) Contractor shall bring the new weighted suction line strainer as per existing model and make ,size for replacement of u/s.. (ii) Before procurement of weighted suction line strainer for existing dosing pump contractor shall check the suitibility of model and make ,size of new to match with existing u/s.
S& F in replacement dosing pump Injection check valve suitable for existing dosing pump complete all as specified and directed by EIC . Make of Injection check valve :- Declibac / Ramco or equivalent as approved by GE Note :- (i) Contractor shall bring the new Injection check valve as per existing model and make ,size for replacement of u/s.. (ii) Before procurement of Injection check valve for existing dosing pump contractor shall check the suitibility of model and make ,size of new to match with existing u/s.
S& F in replacement rubber sheet of min 3 mm thickness for use in jointing sulice valves with flange etc complete all as specified and directed by Eng in charge.
Supply and fix MS nut bolt and washer of size as specified complete all as specified and directed by Eng in charge.
Supply and fix U clamp heavy duty for steel wire rope clamping all as specified by EIC.
S&F in repair 15mm size bib tap standard of PTMT any colour long body high pressure screwed for iron pipe and fixed (minimum weight 15mm – 90 gms) complete all as specified & as directed.
S & F in replacement LED street lights nominal power 60 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 6000, lumen efficacy of minimum 100 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hours as per catalogue No. LR02-671-XXX-57-XX of Wipro or equivalent of Make mentioned under Appendix "B" including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed.
Supply & Fix fully automatic star delta Submersible pump starter in sheet steel enclouser suitable for 20 HP pump set , 3 phase , 415 volt , 50 Hz , including making all electrical connection to run the pump and taking out old unserviceable complete all as specified and directed by Engr-In-Charge. Make:- C&S Cat Part No- BE3-SPSDDX254 322 or equivalent in L&T/BCH
Supply & Fix fully automatic star delta Submersible pump starter in sheet steel enclouser suitable for 15 HP pump set , 3 phase , 415 volt , 50 Hz including making all electrical connection to run the pump and taking out old unserviceable complete all as specified and directed by Engr-In-Charge. Make:- C&S Cat Part No- BE3-SPSDDX254 321X or equivalent in L&T/BCH
Supply & Fix DOL pump starter in sheet steel enclouser suitable for 7.5 HP pump set , 3 phase , 415 volt , 50 Hz including making all electrical connection to run the pump and taking out old unserviceable starter complete all as specified and directed by Engr-In-Charge. Make:- C&S, Cat part No - BE1SPSDDX204 321-HM or equivalent in L&T/BCH
Supply & Fix DOL pump starter in sheet steel enclouser suitable for 3 HP pump set, 3 phase , 415 volt , 50 Hz including making all electrical connection to run the pump and taking out old unserviceable all as specified and directed by Engr-In-Charge. Make:- C&S Cat Part No- BE1-SPSDDX204 310-HM or equivalent in L&T/BCH
S&F seamless MS pipe 100 mm dia bore for bore well column pipe, with flanged end (MS flanges screwed and welded on both ends), including joing and connecting by providing MS nuts, bolts, gasket etc. and lowering in bore well complete all as specified and directed by EIC. Note : (i) The pipe shall be heavy duty MS pipe not less than 6 mm thick of wall conforming to IS-1239 (Part - I) of 1979/3589: 2001. (ii) The flanges shall have 8 hole and grooves to accommodate the submersible cables and sling wires. Lath work required for drilling hole as per existing to be done by contractor without any extra cost. (iii) MS Flange thickness shall not be less than 8 mm. (iv) The length of pipe shall be of 3.0 mtr with MS flange screwed and welded at both the ends.
Supply and connection repairs column pipe 50 MM bore both and flanged made out of GI tubing heavy grade welded at end of column pipe cutting of groove to house submersible cables 3 core 6 sqmm (total length of each column pipe = 3.10 meter including flange at both end) complete all as specified and as directed.
Supply and fix PVC coated steel wire rope 10mm dia with U clamps of suitable size securing the submersible pump motor and taking out old unserviceable complete all as specified and as directed by Engr-in-Charge.
Material and labour for Joint with rubber or leather gasket for flanged pipes/Sluice Valve/NRV/ARV and any other type of valve and fittings of dia 100mm bore with incl nut, bolts, washers etc. and taking out old unservieable complete all as specified and Engr-in-Charge.
Material and labour for Joint with rubber or leather gasket for flanged pipes/Sluice Valve/NRV/ARV and any other type of valve and fittings of dia 150mm bore with incl nut bolts, washers etc and taking out old unserieable complete all as specified and Engr-in-Charge.
S & F MCCB, fixed thermal & fixed magnetic setting, 4 pole, 415 volts, 25 kA, 125 A complete all as specified and as directed.
M&L for PCC (1:4:8) type D2 using 40 mm graded stone aggregate as in motor foundation, filling and mass concrete including demolation of concrete of any description complete all as specified and directed by Engr-in-Charge.
Material and labour for plastering 15 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:4 finished even and smooth without using extra cement including taking down old plaster complete all as specified and directed
Taking out old lead from joint of pipe line and Material and labour in repair run lead joints for connecting of the CI pipes of 300 mm dia of pipe complete all as specified and directed.
Taking out old lead from joint of pipe line and Material and labour in repair run lead joints for connecting of the CI pipes of 250 mm dia of pipe complete all as specified and directed.
Taking out old lead from joint of pipe line and Material and labour in repair run lead joints for connecting of the CI pipes of 200 mm dia of pipe complete all as specified and directed.
Taking out old lead from joint of pipe line and Material and labour in repair run lead joints for connecting of the CI pipes of 150 mm dia of pipe complete all as specified and directed.
Taking out old lead from joint of pipe line and Material and labour in repair run lead joints for connecting of the CI pipes of 100 mm dia of pipe complete all as specified and directed.
Taking out old lead from joint of pipe line and Material and labour in repair run lead joints for connecting of the CI pipes of 80 mm dia of pipe complete all as specified and directed.
M&L for framed work for valve pit chamber cover made of Mild steel (MS) equal angle and MS sheet 2.8 mm thick including welding , cutting ,hinges , locking arrangments , painting including dismantling wrought iron or mild steel work of any description provided for valve pit chamber and for angle iron ladder of tank complete with and including two coat synthethic enamel paint high glossy finish, of Make Asian Apcolite rust shield , Anti rust shield PU enamel or equivalent make as catered in PS over and including a coat of primer and dismentaling of existing unservieable one complete all as specified and directed
Supply and fix water level indicator made of aluminium base, marked with white Radium paint connected with steel wire rope 4 mm dia to counter weight showing level of water containing in tank including 8" dia brass float ball , and greasing of revolving pully of as per site requirement as existing specification and fixed to pillar of water tank with safety measures complete all as specified and directed by Engr-in-Charge Note : All T&P required at site for fixing water level indicator on over head Tank at 18/21 mtr height shall be arranged by contractor . (ii) To remove the Bee Hives for fixing the guadge on water tank of height 18/21 mtr shall be contractor responsbility with any extra cost.
Material and Labour for complete removal of old painted steel surface of any description upto working height upto 25 mtr and painted one coat of red oxide primer after then two coat of synthethic enamel paint of SKY Blue / Red / Yellow colour, high glossy finish, rust shield , Anti rust shield PU enamel , having quick drying time complete all as directed as per engineer-in-charge. Make Asian Paints (Apcolite rust shield) or equivalent in Narolac/Berger
Supply and fix in repair short piece MS pipe heavy duty, min thickness 6 mm, of min length 1.0 mtr, 100 mm dia having one end welded and screwed with MS flange having 4 or 8 hole and grove for passing of submersible cable and wire ropeand other side with thread end having 8 pitch complete all as directed and specified by EIC.
Supply and fix in repair short piece MS pipe heavy duty, min thickness 6 mm, of min length 1.0 mtr, 100 mm dia having one end welded and screwed with MS flange having 4 or 8 hole and grove for passing of submersible cable and wire ropeand other side with thread end having 11 pitch complete all as directed and specified by EIC.
Supply and fix in repair MS reducer socket of size 150 mm x 100 mm dia having internal thread on 150 mm side and external thread on 100 mm side. complete all as directed and specified by EIC.
Supply and fix in repair MS reducer socket of size 100 mm x 80 mm dia having internal thread on 100 mm side and external thread on 80 mm side. complete all as directed and specified by EIC.
Supply and fix in repair MS reducer socket of size 100 mm x 50 mm dia having internal thread on 100 mm side and external thread on 50 mm side. complete all as directed and specified by EIC.
Supply and fix in repair MS reducer socket of size 80 mm x 50 mm dia having internal thread on 80 mm side and external thread on 50 mm side. complete all as directed and specified by EIC.
Supply and fix in repair MS reducer socket of size 150 mm x 80 mm dia having internal thread on 150 mm side and external thread on 80 mm side. complete all as directed and specified by EIC.
M & L for brick work with sub class ‘B’ bricks, straight or curved on plan to exceeding 6m mean radius, built in 1:4 cement mortar including demolation of brick work of any description complete all as specified and directed by Engr-in-Charge.
S & F in repairs submersible cable flat PVC insulation of type C and having PVC sheath of type ST2, flexible conductor, FR-LSH, 3 core of size 6 sqmm complete all as specified and as directed.
(a) Lifting of defective submersible pump set of any make and capacity 15 HP from after providing lifting tools , chain pulley etc. as required carefully, by disconnecting/dismantling all electric connections, column pipes, steel ropes/chain and keeping them under safe custody for reuse and Comprehensive maintenance as per Original Equipment Manufacturer's (OEMs) reccommendations installed at various locations through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies as approved by GE with replacement of oil seal, sand guard, bolt gasket, cable packing ring, circlip, bearing bush upper & lower etc.and applying two coats of synthetic enamel paint over a coat of red oxide primer after preparation of pump external surface complete all as specified and directed. all complete and (b) Lowering of repaired /overhauled/rewinded submersible pumping set of any make and capacity after proper coupling of pump and motor , fixing old/new chain with clamp, connecting/refixing existing/new column pipe lines with new rubber gasket 3 mm thick, nuts, bolts & washers carefully with the help of chain pulley etc. & carefully re-connecting all electric/water lines and testing on load to the entire satisfaction of Engineer-in-charge complete.
NOTE : (i) The cost of transportation of the defective submersible pumping set (pump or motor) from site to OEM workshop & back is deemed to be included in the quoted rates. (ii) Column pipe/ submersible cable/supporting chain required new will be measured and paid separately as supply only. (iii) Repair of motor and pump measured separately (iv) refixing of column pipe to be done after proper descaling . (v) Each maintenance job shall be covered period of 09 Months. (vi) All minor spares required for making the pump functional shall be provided by contractor without any extra cost.(vii) Breakdown Maintenance : The Authorised Service Engineer of OEM or OEM Certified Agencies will carry out all breakdown maintenance after receiving information (written or oral) from GE kalaikunda officials or their representatives.The OEM's authorised service representative or OEM certified agencies will carry out the required repairs of the units and appraise GE, Engineer-in-Charge and JE the status of the break down repair at site. No payment shall be made on account of any breakdown service to the machinary/equipments during comprehensive maintenence period. (viii) The Service Engineer will be called in case of any breakdown and the same shall be attended within 24 Hours of lodging of complaint, failing which a penal recovery of Rs.500.00 (Rupees Five Hundred Only) per day till such time the unit is attended and complaint is resolved,will be recovered from the outstanding dues to the Contract. ( viii) it is mandatory to submit vist report of OEM represenatative along with spare replaced/ serviceing carried out along his claim (ix) Cost of minor items like insulating tape,gland packing materials, metal washers, fibre/rubber washers, screws, small nuts & bolts and like shall be deemed to be inclusive of the quoated rate.
M & L for rewinding of burnt submersible pump set of any make and capacity up to 15 HP, 3 phase ,415 V, 50 Hz of any make with water proof insulated copper conductor of the same specification as per old one after dismantling / cutting out burnt windings from stator assembly, cleaning slots properly complete with insulating slots packing, sleeves, papers & reassembling stator and rotor after replacement of worn out spares/matching works as per Original Equipment Manufacturer's (OEMs) reccommendations through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies as approved by GE including painting with two coats of synthetic enamel paint over a coat of red oxide primer after preparation of motor external surface and water proof jointing for submersible cable 3 core, with replacement of oil seal, sand guard, bolt gasket, cable packing ring, circlip, bearing bush upper & lower etc. complete as specified and directed.
Supply & fix Rotor shaft with couplings and seals of submersible motor of capacity 15 HP as per Original Equipment Manufacturer's (OEMs) reccommendations through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies as approved by GE [Make: Calama/Kriloskar/CRI/KSB/Crompton Greaves/]
M&L for replacement of thrust bearing as per Original Equipment Manufacturer's (OEMs) reccommendations through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies as approved by GE for Submersible motor of capacity 15 HP complete as specified and directed [Make: Calama/Kriloskar/CRI/KSB/Crompton Greaves/]
Supply & fix Impeller of submersible motor of capacity of 15 HP as per Original Equipment Manufacturer's (OEMs) reccommendations through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies as approved by GE [Make: Calama/Kriloskar/CRI/KSB/Crompton Greaves/]
Supply & fix diffuser of submersible motor of capacity of 15 HP as per Original Equipment Manufacturer's (OEMs) reccommendations through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies as approved by GE [Make: Calama/Kriloskar/CRI/KSB/Crompton Greaves/]
Supply & fix neck ring of submersible motor of capacity 15 HP as per Original Equipment Manufacturer's (OEMs) reccommendations through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies as approved by GE [Make: Calama/Kriloskar/CRI/KSB/Crompton Greaves/]
Supply & fix stud nut of submersible motor of capacity of 15 HP as per Original Equipment Manufacturer's (OEMs) reccommendations through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies as approved by GE [Make: Calama/Kriloskar/CRI/KSB/Crompton Greaves/]
(a) Lifting of defective submersible pump set of any make and capacity 20 HP from after providing lifting tools , chain pulley etc. as required carefully, by disconnecting/dismantling all electric connections, column pipes, steel ropes/chain and keeping them under safe custody for reuse and Comprehensive maintenance as per Original Equipment Manufacturer's (OEMs) reccommendations installed at various locations through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies as approved by GE with replacement of oil seal, sand guard, bolt gasket, cable packing ring, circlip, bearing bush upper & lower etc.and applying two coats of synthetic enamel paint over a coat of red oxide primer after preparation of pump external surface complete all as specified and directed. all complete and (b) Lowering of repaired /overhauled/rewinded submersible pumping set of any make and capacity after proper coupling of pump and motor , fixing old/new chain with clamp, connecting/refixing existing/new column pipe lines with new rubber gasket 3 mm thick, nuts, bolts & washers carefully with the help of chain pulley etc. & carefully re-connecting all electric/water lines and testing on load to the entire satisfaction of Engineer-in-charge complete.
NOTE : (i) The cost of transportation of the defective submersible pumping set (pump or motor) from site to OEM workshop & back is deemed to be included in the quoted rates. (ii) Column pipe/ submersible cable/supporting chain required new will be measured and paid separately as supply only. (iii) Repair of motor and pump measured separately (iv) refixing of column pipe to be done after proper descaling . (v) Each maintenance job shall be covered period of 09 Months. (vi) All minor spares required for making the pump functional shall be provided by contractor without any extra cost.(vii) Breakdown Maintenance : The Authorised Service Engineer of OEM or OEM Certified Agencies will carry out all breakdown maintenance after receiving information (written or oral) from GE kalaikunda officials or their representatives.The OEM's authorised service representative or OEM certified agencies will carry out the required repairs of the units and appraise GE, Engineer-in-Charge and JE the status of the break down repair at site. No payment shall be made on account of any breakdown service to the machinary/equipments during comprehensive maintenence period. (viii) The Service Engineer will be called in case of any breakdown and the same shall be attended within 24 Hours of lodging of complaint, failing which a penal recovery of Rs.500.00 (Rupees Five Hundred Only) per day till such time the unit is attended and complaint is resolved,will be recovered from the outstanding dues to the Contract. ( viii) it is mandatory to submit vist report of OEM represenatative along with spare replaced/ serviceing carried out along his claim (ix) Cost of minor items like insulating tape,gland packing materials, metal washers, fibre/rubber washers, screws, small nuts & bolts and like shall be deemed to be inclusive of the quoated rate.
M & L for rewinding of burnt submersible pump set of any make and capacity up to 20HP, 3 phase ,415 V, 50 Hz of any make with water proof insulated copper conductor of the same specification as per old one after dismantling / cutting out burnt windings from stator assembly, cleaning slots properly complete with insulating slots packing, sleeves, papers & reassembling stator and rotor after replacement of worn out spares/matching works as per Original Equipment Manufacturer's (OEMs) reccommendations through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies as approved by GE including painting with two coats of synthetic enamel paint over a coat of red oxide primer after preparation of motor external surface and water proof jointing for submersible cable 3 core, with replacement of oil seal, sand guard, bolt gasket, cable packing ring, circlip, bearing bush upper & lower etc. complete as specified and directed.
Supply & fix Rotor shaft with couplings and seals of submersible motor of capacity 20 HP as per Original Equipment Manufacturer's (OEMs) reccommendations through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies as approved by GE [Make: Calama/Kriloskar/CRI/KSB/Crompton Greaves/]
M&L for replacement of thrust bearing as per Original Equipment Manufacturer's (OEMs) reccommendations through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies as approved by GE for Submersible motor of capacity 20HP complete as specified and directed [Make: Calama/Kriloskar/CRI/KSB/Crompton Greaves/]
Supply & fix Impeller of submersible motor of capacity of 20HP as per Original Equipment Manufacturer's (OEMs) reccommendations through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies as approved by GE [Make: Calama/Kriloskar/CRI/KSB/Crompton Greaves/]
Supply & fix diffuser of submersible motor of capacity of 20 HP as per Original Equipment Manufacturer's (OEMs) reccommendations through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies as approved by GE [Make: Calama/Kriloskar/CRI/KSB/Crompton Greaves/]
Supply & fix neck ring of submersible motor of capacity 20 HP as per Original Equipment Manufacturer's (OEMs) reccommendations through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies as approved by GE [Make: Calama/Kriloskar/CRI/KSB/Crompton Greaves/]
Supply & fix stud nut of submersible motor of capacity of 20 HP as per Original Equipment Manufacturer's (OEMs) reccommendations through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies as approved by GE [Make: Calama/Kriloskar/CRI/KSB/Crompton Greaves/]
(a) Lifting of defective submersible pump set of any make and capacity 7.5 HP from after providing lifting tools , chain pulley etc. as required carefully, by disconnecting/dismantling all electric connections, column pipes, steel ropes/chain and keeping them under safe custody for reuse and Comprehensive maintenance as per Original Equipment Manufacturer's (OEMs) reccommendations installed at various locations through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies as approved by GE with replacement of oil seal, sand guard, bolt gasket, cable packing ring, circlip, bearing bush upper & lower etc.and applying two coats of synthetic enamel paint over a coat of red oxide primer after preparation of pump external surface complete all as specified and directed. all complete and (b) Lowering of repaired /overhauled/rewinded submersible pumping set of any make and capacity after proper coupling of pump and motor , fixing old/new chain with clamp, connecting/refixing existing/new column pipe lines with new rubber gasket 3 mm thick, nuts, bolts & washers carefully with the help of chain pulley etc. & carefully re-connecting all electric/water lines and testing on load to the entire satisfaction of Engineer-in-charge complete.
NOTE : (i) The cost of transportation of the defective submersible pumping set ( pump or motor ) from site to OEM workshop & back is deemed to be included in the quoted rates. (ii) Column pipe/ submersible cable/supporting chain required new will be measured and paid separately as supply only. (iii) Repair of motor and pump measured separately (iv) refixing of column pipe to be done after proper descaling . (v) Each maintenance job shall be covered period of 09 Months..(vi) All minor spares required for making the pump functional shall be provided by contractor without any extra cost.(vii) Breakdown Maintenance : The Authorised Service Engineer of OEM or OEM Certified Agencies will carry out all breakdown maintenance after receiving information (written or oral) from GE kalaikunda officials or their representatives.The OEM's authorised service representative or OEM certified agencies will carry out the required repairs of the units and appraise GE, Engineer-in-Charge and JE the status of the break down repair at site. No payment shall be made on account of any breakdown service to the machinary/equipments during comprehensive maintenence period. (viii) The Service Engineer will be called in case of any breakdown and the same shall be attended within 24 Hours of lodging of complaint, failing which a penal recovery of Rs.500.00 (Rupees Five Hundred Only) per day till such time the unit is attended and complaint is resolved,will be recovered from the outstanding dues to the Contract( viii) it is mandatory to submit vist report of OEM represenatative along with spare replaced/ serviceing carried out along his claim (ix) Cost of minor items like insulating tape,gland packing materials, metal washers, fibre/rubber washers, screws, small nuts & bolts and like shall be deemed to be inclusive of the quoated rate.
M & L for rewinding of burnt submersible pump set of any make and capacity up to 7.5 HP, 3 phase ,415 V, 50 Hz of any make with water proof insulated copper conductor of the same specification as per old one after dismantling / cutting out burnt windings from stator assembly, cleaning slots properly complete with insulating slots packing, sleeves, papers & reassembling stator and rotor after replacement of worn out spares/matching works as per Original Equipment Manufacturer's (OEMs) reccommendations through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies as approved by GE including painting with two coats of synthetic enamel paint over a coat of red oxide primer after preparation of motor external surface and water proof jointing for submersible cable 3 core, with replacement of oil seal, sand guard, bolt gasket, cable packing ring, circlip, bearing bush upper & lower etc. complete as specified and directed.
Supply & fix Rotor shaft with couplings and seals of submersible motor of capacity 7.5 HP as per Original Equipment Manufacturer's (OEMs) reccommendations through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies as approved by GE [Make: Calama/Kriloskar/CRI/KSB/Crompton Greaves/]
M&L for replacement of thrust bearing as per Original Equipment Manufacturer's (OEMs) reccommendations through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies as approved by GE for Submersible motor of capacity 7.5HP complete as specified and directed [Make: Calama/Kriloskar/CRI/KSB/Crompton Greaves/]
Supply & fix Impeller of submersible motor of capacity of 7.5HP as per Original Equipment Manufacturer's (OEMs) reccommendations through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies as approved by GE [Make: Calama/Kriloskar/CRI/KSB/Crompton Greaves/]
Supply & fix diffuser of submersible motor of capacity of 7.5HP as per Original Equipment Manufacturer's (OEMs) reccommendations through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies as approved by GE [Make: Calama/Kriloskar/CRI/KSB/Crompton Greaves/]
Supply & fix neck ring of submersible motor of capacity 7.5HP as per Original Equipment Manufacturer's (OEMs) reccommendations through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies as approved by GE [Make: Calama/Kriloskar/CRI/KSB/Crompton Greaves/]
Supply & fix stud nut of submersible motor of capacity of 7.5HP as per Original Equipment Manufacturer's (OEMs) reccommendations through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies as approved by GE [Make: Calama/Kriloskar/CRI/KSB/Crompton Greaves/]
Comprehensive maintenance as per Original Equipment Manufacturer's (OEMs) reccommendations for a period of nine months for 7.5 HP capacity 3- phase, 415 volts, 50 Hz Openwell submersible /Monoblock pump sets installed at various locations through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies as approved by GE,and including rewinding of burnt Openwell submersible /Monoblock motor 5 HP , 3 phase ,415 V, 50 Hz of any make with water proof insulated copper conductor of the same specification as per old one after dismantling / cutting out burnt windings from stator assembly, cleaning slots properly complete with insulating slots packing, sleeves, papers & reassembling stator and rotor after replacement of worn out spares/matching works including painting with two coats of synthetic enamel paint over a coat of red oxide primer after preparation of motor external surface complete all as specified and directed. [Make: Calama/Kriloskar/CRI/KSB/Crompton Greaves/]Note spare part required to replaced repair upto Rs 2000 deemed to be inluded in quoated rates
Comprehensive maintenance as per Original Equipment Manufacturer's (OEMs) reccommendations for a period of nine months for 5 HP capacity 3- phase, 415 volts, 50 Hz Openwell submersible /Monoblock pump sets installed at various locations through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies as approved by GE,and including rewinding of burnt Openwell submersible /Monoblock motor 5 HP , 3 phase ,415 V, 50 Hz of any make with water proof insulated copper conductor of the same specification as per old one after dismantling / cutting out burnt windings from stator assembly, cleaning slots properly complete with insulating slots packing, sleeves, papers & reassembling stator and rotor after replacement of worn out spares/matching works including painting with two coats of synthetic enamel paint over a coat of red oxide primer after preparation of motor external surface complete all as specified and directed. [Make: Calama/Kriloskar/CRI/KSB/Crompton Greaves/]Note spare part required to replaced repair upto Rs 2000 deemed to be inluded in quoated rates
Comprehensive maintenance as per Original Equipment Manufacturer's (OEMs) reccommendations for a period of nine months for 3 HP capacity 3- phase, 415 volts, 50 Hz Openwell submersible /Monoblock pump sets installed at various locations through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies as approved by GE,and including rewinding of burnt Openwell submersible /Monoblock motor 3 HP , 3 phase ,415 V, 50 Hz of any make with water proof insulated copper conductor of the same specification as per old one after dismantling / cutting out burnt windings from stator assembly, cleaning slots properly complete with insulating slots packing, sleeves, papers & reassembling stator and rotor after replacement of worn out spares/matching works including painting with two coats of synthetic enamel paint over a coat of red oxide primer after preparation of motor external surface complete all as specified and directed. [Make: Calama/Kriloskar/CRI/KSB/Crompton Greaves/]Note spare part required to replaced repair upto Rs 2000 deemed to be inluded in quoated rates
Comprehensive maintenance as per Original Equipment Manufacturer's (OEMs) reccommendations for a period of nine months for 1 HP capacity 3- phase, 415 volts, 50 Hz Openwell submersible /Monoblock pump sets installed at various locations through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies as approved by GE,and including rewinding of burnt Openwell submersible /Monoblock motor 3 HP , 3 phase ,415 V, 50 Hz of any make with water proof insulated copper conductor of the same specification as per old one after dismantling / cutting out burnt windings from stator assembly, cleaning slots properly complete with insulating slots packing, sleeves, papers & reassembling stator and rotor after replacement of worn out spares/matching works including painting with two coats of synthetic enamel paint over a coat of red oxide primer after preparation of motor external surface complete all as specified and directed. [Make: Calama/Kriloskar/CRI/KSB/Crompton Greaves/]Note spare part required to replaced repair upto Rs 2000 deemed to be inluded in quoated rates
M&L for earthing complete with galvanised steel earth plate electrode size 600 x 600 x 6 mm thick, burried directly in ground, (Earth pit not less than 3.25 m deep below ground level) with top edge of the plate not less than 2.5 m below ground level connected to galvanised iron strip 32 x 6 mm as earthin lead wire by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion, surrounded from all sides by mixture of charcoal and common salt and electrode by means of steel and GI pipe light grade 20mm dia bore for watering funnel with wire mesh. CI cover with frame, PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 3 connected to earthing test point all as specified NOTES 1. The unit rate includes for protection pipe and GI strip dia from top of earth plate upto 7.5 meter above ground level. NOTE:- 1. The unit rate includes for protection GI pipe of 40 mm and watering pipe of 20 mm bore including excavation for earth pit in any type of soil/ disintegrate rock. 2. Contractor has to bring agriculture soil from outside of defence land and fill in earth pit to achieve desired result as the soil resistiviy is very high. 3.The cost of GI strip of size 25 X 4 mm from top of earth plate upto 7.5 meter above ground level is deemed to be included in the unit rate of above item.and copper strip beyond 7.5 RM will be measured seperately. 4. All the joints in GI strip and connection with Earth Plate to be welded through brazing and in addition by providing double brass nut bolt and washer. 5. Cost of welding and nut bolts are deemed to be included in the unit rate.
Demolition of PCC in ground floors & pavings n exc 15 cm thickness (below or above ground level) (unreinforced) complete all as specified and as directed.
Taking down cement plaster from brick or concrete surfaces of any description including raking out joints, hacking for key, scrubbing down with water etc complete all as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises complete all as directed.
Taking up or down 15 mm bore of steel tubing and connections, including cleaning for refixing or removal to store complete all as specified.
Taking up or down 20 mm bore of steel tubing and connections, including cleaning for refixing or removal to store complete all as specified.
Taking down SWR pipes (any size or pattern), including all fittings, 'T', bends,etc., including removal to store for taking credit (measured overall as fixed along the centre line over fittings and accessories), complete all as directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 sqm each complete all as specified and as directed
Taking down chowkats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 sqm but not exceeding 4.00 sqm each complete all as specified and as directed
M & L 50 mm thick plain cement concrete M15(Nominal Mix) using 20 mm nominal size graded stone aggregates finished surface even and fair as in plinth protection all as specified and as directed.
Materials and Labour for 40 mm thick plain cement concrete M15(Nominal Mix), using 20 mm graded aggregate as floor/paving/hardstanding, complete all as specified and directed.
Materials and Labour for, Digital Non - skid Ceramic tiles, coloured, 9 to 10mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm,conforming to IS 15622, Grade B II, in riser of steps, skirting, dado and pillar laid over cement screed base including 20 thick rendering Cement mortar (1:4) complete all as specified and directed
Materials and Labour for, Digital glazed ceramic coloured tiles, 450 X 300 X 8mm thick, conforming to IS 15622, Grade B III, on vertical surface of wall such as dados,skirting etc, set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10 mm thick screed bed or bedding layer of cement mortar (1:4), complete all as specified and directed.
Materials and Labour for rendering 15 mm thick, cement plaster, in cement mortar (1:6) on surface fair face of brickwork in walls and finishing surface even and smooth without using extra cement, complete all as specified and directed.
Material and labour for plastering 5 mm thick on fair faces of brick work or concrete surfaces (on ceiling surfaces) in cement mortar 1:3 finished even and fair complete all as specified and as directed.
Material and Labour for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel and iron surface not exceeding 10 cm in width or girth including preparation of surfaces complete all as specified and directed.
M&L for preparation of old painted wood or wooden surfaces, of any description, over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
M&L for preparation of old painted on brick, stone,concrete, asbestos cement or plaster surfaces, of any description, over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
M&L for preparation of old painted steel and iron surface, of any description, over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
M&L for preparation of old painted steel and iron surface, of any description, not exc 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of walls, and applying two coats acrylic distemper on wall ,over and including with a coat of 2 mm thick white wall care putty premium quality over and including a coat of primer new plastered or unplastered surfaces on wall, complete all as specified and as directed.Make;Berger (Bison)/J&N(Jensolin)/Asain Piants(Tractor)/Nerolac(Beauty)
M&L for preparation of newly plastered surfaces of ceiling, and applying two coats acrylic distemper on ceiling ,over and including with a coat of 1 mm thick white wall care putty premium quality over and including a coat of primer new plastered or unplastered surfaces on wall, complete all as specified and as directed.Make;Berger (Bison)/J&N(Jensolin)/Asain Piants(Tractor)/Nerolac(Beauty)
M&L for complete removal of existing treatment from walls, and applying two coats acrylic distemper on walls,over and including a coat of 1.5 mm thick white wall care putty premium quality over and including a coat of primer old plastered on walls complete all as specified and as directed.Make;Berger (Bison) / J&N (Jensolin)/ Asain Piants (Tractor) /Nerolac (Beauty)
M&L for preparing old decorated plastered or unplasterd surfaces of wall including cornices, pilasters and other wall features etc by brooming down or steel wire brushing/sand paper, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and removing extra wall papdi ,peel off wall papdi by sand paper and making good with putty as per existing thickness and applying one coat acrylic distemper on old surfaces complete all as specified Make;Berger (Bison)/J&N(Jensolin)/Asain Piants(Tractor) /Nerolac (Beauty)
All as per item No : 129.00 here in before but on ceiling surfaces omplete all as specified Make;Berger (Bison)/J&N(Jensolin)/Asain Piants(Tractor)/Nerolac(Beauty)
M&L for preparing old decorated plastered or unplasterd surfaces of wall including cornices, pilasters and other wall features etc by brooming down or steel wire brushing/sand paper, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and removing extra wall papdi ,peel off wall papdi by sand paper and making good with putty as per existing thickness and applying two coat acrylic distemper on old surfaces complete all as specified Make;Berger (Bison)/J&N(Jensolin)/Asain Piants(Tractor) /Nerolac (Beauty)
Supply and Fix, factory made rigid lam PVC door frame of size 100 mm x 50 mm, with wall thickness of extruded 5mm PVC sheet of density 600 kgs/cum , made by joining 3 Nos. heat bent PVC sheet sections. The inside section of size 90mm x 30 mm shall be made from colour PVC sheet of 5 mm thickness.The inside section shall be covered by sticking two sections of size 35mm and 6 x 45 mm made from 5mm thick plain sheet. The frame shall be mitred cut at two corners and jointed by inserting 4 Nos. 150 mm long brackets of 15mm x15 mm MS square tube. The two vertical members of door frame shall be reinforced with 40mm x 20 mm MS tubes of 19 SWG duly filled with 2nd class hardwood throughout the frame. The door frame shall be fixed to the wall using 100 mm long nikel coated dry wheet screws through the frame by using PVC fastener. Minimum 04 Nos. of screws shall be provided for each vertical member and minimum 02 Nos.for horizontal members etc. as per manufacturers specifications, fixed in opening, complete all as specified and directed.
Materials and Labour , Factory Made Solid PVC Moulded Door designer Shutter, with particle board core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm prelam PVC sheet on back face, supplying & fixing in frame at site as per specification and drawing, complete all as specified and directed.
S & F in repair double action concealed type floor springs (hydraulically regulated) made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel top cover, governing pivot made of brass, other parts made of mild steel heavy duty complete all as specified and as directed.
S&F aluminium barrel tower bolts with barrel and bolt of extruded sections of aluminium alloys, 150 mm long, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and as directed.
S & F 100 mm medium weight stainless steel butt hinges made out of cold reduced low carbon steel or hot rolled carbon steel as per IS 1341: 1992 complete all as specified and as directed.
S&F 150mm aluminum extruded aluminium alloy handles (fabricated type) anodised of mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
S & F PVC-U, type B as per IS 13592: 2013 single socketed soil waste pipes in any length with rubber ring joints, 110 mm dia, fixed to walls incuding mild steel clamp not more than 1metre C/C complete all as specified and directed by Engineer- in- charge .
All as per No.138.00 above item but fixing only including all new fitting complete all as specified and directed by Engineer- in- charge .
S & F UPVC bends with inspection door (any angle), 110 mm dia conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge
S & F PVC-U, type B as per IS 13592: 2013 single socketed soil waste pipes in any length with rubber ring joints, 75 mm dia, fixed to walls incuding mild steel clamp not more than 1metre C/C complete all as specified and directed by Engineer- in- charge .
S & F UPVC bends with inspection door (any angle), 75 mm dia conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge
Supply and fix PVC SWR Nahani/ Floor trap, multi inlet connection, plain with grating including jointing with solvent cement, dia of outlet 75 mm, water seal minimum 50 mm, complete all as specified and directed by Engineer in charge.
S&F in repairs health faucet brass chromium plated suitable for 15mm dia pipe with 1.25 meter long flexible tube and wall 1.25 m long flexible tube and brass wall hook including making connection and fixed in position complete all as specified & as directed.
S&F in repairs toilet paper holder with flat recessed type stainless steel complete all as specified and directed
S & F in repairs wash basins, vitreous china, white, flat back, size 550 mm X 400 mm with and including cast iron brackets (embedded in wall upto 110 mm depth with and including cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate or fixing on wall with and including rawl plug and screws), 32 mm nominal size, copper alloy, nickel chromium plated finish waste fittings, including painting of fittings and brackets, sealing gap between wall and basin with silicone sealant, cutting and making good the walls wherever required and connecting to supply pipes, waste pipes, waste fittings etc. with silicone sealant complete all as specified and as directed.
S & F flexible (coil shaped) PVC waste pipe for sink and wash basin 32 mm dia with length not less than 900 mm connected to PVC waste fittings complete all as specified and as directed.
Supply and Fix, pillar taps, cast copper alloy, with capstan heads, fancy type, chromium plated, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nuts, screwed for iron pipe, 15 mm bore, including taking down existing unserviceable one complete all as specified and directed.
S & F in repairs vitreous china wash down water closet (pedestal pattern), white including thermoplastic seats and covers of grade 2 type, flat with hinging device of bronze or brass with nickel chromium plating, fixing bolt, connector to flush pipe and making connections to flush pipe, connector to branch soil pipe and anti syphonage pipes etc. including sealing the joints and making leak proof using sealant complete all as specified and as directed by Engineer-in-Charge.
S & F in repairs in repairs thermoplastic seats and covers of grade 2 type, flat with hinging device of bronze or brass with nickel chromium plating complete all as specified and as directed.
S & F in repair Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern to squatt pattern all as specified and as directed.
S&f in repair vitreous China Urinal, Half stall type, white of size (380x405x590mm) (excluding flushing cistern, flush pipe and waste pipe) with brass chromium plated spreader complete all as per of Make Parryware Cat C0583 (Combo Set) complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe complete all as specified and as directed.
S&F in repair Urinal spreader of PTMT any colour for fixing with 15mm dia pipe (min. weight 60gms) complete all as specified and as directed
S & F in repairs PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and as directed.
S & F flexible (coil shaped) PVC waste pipe for sink and wash basin 32 mm dia with length not less than 700 mm connected to PVC waste fittings complete all as specified and as directed.
Supply and Fix, brass chromium plated, towel rail, 20mm dia, , 60cm long between flanges, complete all as specified and directed.Make Cat no.ACN-1111NM of Jaquar or equivalent of Marc/Kohler
Supply and fixing of Grating round 125 mm size of PTMT. (Minimum weight 50gms) complete including jointing with solvent cement, all as specified & as directed.
S & F in repairs 15 mm nominal size, screw down bib taps, cast copper alloy body and body components with crutch handle, nickel-chromium plated finished complete all as specified and as directed.
S & F in repairs 15 mm nominal size, nonrising spindle type fancy concealed stop valves as per IS 8931: 1993 made of cast brass including Knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed
S&F in repair Waste coupling 40mm bore of PTMT (half or full threaded) min. weight 40mm-60 gms) complete all as specified and directed
S&F in repair Waste coupling 32mm bore of PTMT (half or full threaded) suitable for urinals (min. weight 32mm-45gms) complete all as specified and directed
S & F in repair brass chromium plated shower rose 125 mm size with or without swivel joints with shower arm, any size, including fixing to steel pipe or union complete all as specified and as directed.
S&F in repair Ball brass valves 20mm bore, high pressure, with polythene float & flynut complete, screwed for iron pipe or brass ferrule complete all as specified and as directed.
S&F 500 ltrs IS marked multilayer rotational moulded polythytene water storage tanks (cylindrical vertical with closed top) as per IS 12701: 1996hoisted and fixed in position with and including 20mm brass ball valves high pressure with polythene float and nut with and including provision of 20 mm /15 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes including dismantling exsiting one complete all as specified and directed .
S&F 1000 ltrs IS marked multilayer rotational moulded polythytene water storage tanks (cylindrical vertical with closed top) as per IS 12701: 1996 hoisted and fixed in position with and including 25mm brass ball valves high pressure with polythene float and nut with including provision of 20 mm /15 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes including dismantling exsiting one complete all as specified and directed .
M&L for disconnecting existing tank setting aside for repairs, including cleaning of service PVC tank by rubbing vertical wall and bottom of with bleaching powder and allowed ½ hour to react and then washing down with water to get free from deposits and bleaching inside the tank of capacity and mouth of circulating pipes and hoisting, reconnecting and refixing in position capacity exc.300 and not exc. 500 ltrs complete all as specified & as directed. Note : Spare part required to be replaced up to Rs 200 deemed to be included in quoated rates.
M&L for disconnecting existing tank setting aside for repairs, including cleaning of service PVC tank by rubbing vertical wall and bottom of with bleaching powder and allowed ½ hour to react and then washing down with water to get free from deposits and bleaching inside the tank of capacity and mouth of circulating pipes and hoisting, reconnecting and refixing in position capacity exc.500 and not exc. 1000 ltrs complete all as specified & as directed.Note : Spare part required to be replaced up to Rs 200 deemed to be included in quoated rates.
Supplying & fixing to walls , ceiling and laid in trenches 20 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Supplying & fixing to walls , ceiling and laid in trenches 15 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Refixing of old steel tubing and connection with new fittings ISI Marked in new or old position (wall, ceiling, floors, etc) of 15 mm bore complete all as specified and as directed.
Refixing of old steel tubing and connection with new fittings ISI Marked in new or old position (wall, ceiling, floors, etc) of 20 mm bore complete all as specified and as directed.
S & F in repair 10 litres capacity, low level, syphonic type, white, plastic flushing cistern as per IS 7231: 1994 with inlet, ball valve, float and handle including brackets and 40 mm nominal dia high density polyethylene pipes for flush pipe complete all as specified and as directed.
M/s Tekcon International
Dilip Enterprise
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .