| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.6 LAccepted-AOC 179 URBAN ESTATE RAM TIRATH ROAD NR GURUDAWARA DARSHAN SINGH AMRITSAR PUNJAB 143001 | AMRITSAR | PUNJAB | 143001 | ₹10.6 L Quoted ₹10.9 L | L1 | Accepted-AOC lowest bidder |
| 2 | L2₹12.6 L+₹1.6 L (14.8%)Rejected-Finance | ₹12.6 L+₹1.6 L (14.8%) | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 3 | L3₹13.0 L+₹2.1 L (18.8%)Rejected-Finance | ₹13.0 L+₹2.1 L (18.8%) | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 4 | L4₹13.3 L+₹2.4 L (21.6%)Rejected-Finance | ₹13.3 L+₹2.4 L (21.6%) | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 5 | L5₹13.4 L+₹2.4 L (22.2%)Rejected-Finance | ₹13.4 L+₹2.4 L (22.2%) | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| Sl No | Description | Qty | Unit | Pyramid constructions L2 | ASHOKKUMAR SURI L4 | M/S RAJ ENGINEERS L5 | ANIKET TRADERS L6 | G M ENGINEERING SERVICES L7 | M/S VIDYA ENTERPRISES L3 | Mahajan Construction Co L1 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | EXTERNAL ELECTRIC SUPLLY
Taking out of old unserviceable PVC under ground LT cable of any size and type fixed on pole, wall or laid in floors, trenches, across road crossing etc ,including taking out of cable covers of precast PCC / RCC slab or brick cover etc setting aside serviceable materials in safe custody for reuse and or unserviceable materials consider as schedule of credit complete all as specified and as directed.
Note:-
i). Dismantling of clamps nuts bolts etc, taking out of GI pipe in cable protection shall be measured and paid seperately under respective item of this schedule.
ii).Cost for making good the disturbed surfaces of floors / walls in cement mortar 1:3 shall deemed to be included in the unit rate quoated . However cost for making good the disturbed surfaces of roads with PCC and hard core filling is out of scope of this work and shall be measured and paid separetely | 750 | RM | 30 ₹22,500 | 5 ₹3,750 | 5 ₹3,750 | 5 ₹3,750 | 2 ₹1,500 Lowest | 5 ₹3,750 | 5 ₹3,750 |
| 2.00 | Supply , laying , commissioning UG cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm, 4 core cable complete all as specified and directed by Engr-in-Charge.(Make Havells /Polycab/Gloster/KEI) | 150 | RM | 130 ₹19,500 | 150 ₹22,500 | 120 ₹18,000 | 90 ₹13,500 | 150 ₹22,500 | 80 ₹12,000 | 75 ₹11,250 Lowest |
| 3.00 | dito as per item No-02 but size 16 sq mm, 4 core. | 150 | RM | 150 ₹22,500 | 170 ₹25,500 | 140 ₹21,000 | 130 ₹19,500 | 170 ₹25,500 | 105 ₹15,750 | 85 ₹12,750 Lowest |
| 4.00 | dito as per item No-02 but size 25 sq mm, 3.5 core. | 150 | RM | 160 ₹24,000 | 198 ₹29,700 | 190 ₹28,500 | 190 ₹28,500 | 198 ₹29,700 | 180 ₹27,000 | 110 ₹16,500 Lowest |
| 5.00 | dito as per item No-02 but size 35 sq mm, 3.5 core. | 100 | RM | 220 ₹22,000 | 245 ₹24,500 | 290 ₹29,000 | 230 ₹23,000 | 245 ₹24,500 | 220 ₹22,000 | 150 ₹15,000 Lowest |
| 6.00 | dito as per item No-02 but size 50 sq mm, 3.5 core. | 100 | RM | 550 ₹55,000 | 300 ₹30,000 | 340 ₹34,000 | 300 ₹30,000 | 340 ₹34,000 | 400 ₹40,000 | 210 ₹21,000 Lowest |
| 7.00 | dito as per item No-02 but size 70 sq mm, 3.5 core. | 100 | RM | 600 ₹60,000 | 400 ₹40,000 | 410 ₹41,000 | 400 ₹40,000 | 420 ₹42,000 | 500 ₹50,000 | 250 ₹25,000 Lowest |
| 8.00 | Supply and laying of DWC (Double wall corrugated) HDPE pipe, ISI marked, IS-14930 Part-II, having outer dia as 90 mm and inner dia as 76 mm, with smooth internal surface and profiled external surface for non pressure under ground cable including all connected accessories/fittings such as coupler, 'O' ring, etc. for protection of under ground cable complete all as specified and directed by Engr-in-Charge.
MAKE: Rex-Polyextrusion/Gemini or E-in-C's approved make. | 375 | RM | 120 ₹45,000 | 90 ₹33,750 | 80 ₹30,000 | 89 ₹33,375 | 90 ₹33,750 | 60 ₹22,500 Lowest | 98 ₹36,750 |
| 9.00 | Supply and laying of DWC (Double wall corrugated) HDPE pipe, ISI marked, IS-14930 Part-II, having outer dia as 77 mm and inner dia as 63 mm, with smooth internal surface and profiled external surface for non pressure under ground cable including all connected accessories/fittings such as coupler, 'O' ring, etc. for protection of under ground cable complete all as specified and directed by Engr-in-Charge.
MAKE: Rex-Polyextrusion/Gemini or E-in-C's approved make. | 375 | RM | 130 ₹48,750 | 90 ₹33,750 | 70 ₹26,250 | 80 ₹30,000 | 90 ₹33,750 | 50 ₹18,750 Lowest | 85 ₹31,875 |
| 10.00 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in any type of soil for laying of LT UG cables complete.
Note:- The Rate quoted deemed to including cutting and removal of PSP Sheets wherever occured during excavation and the same shall be staged at desired location as directed at site | 192.4 | Cum | 100 ₹19,240 | 120 ₹23,088 | 90 ₹17,316 Lowest | 200 ₹38,480 | 120 ₹23,088 | 120 ₹23,088 | 100 ₹19,240 |
Tender Value
₹17.5 L
EMD Value
₹35,000
Closing Date
3 Jul 2025, 6:00 pmClosed
GE AF Jammu
GE AF Jammu
REPAIR/REPLACEMENT OF LT UG CABLE, STREET LIGHT, OVER HEAD LINE, PANEL BOARD FEEDER PILLARS JUNCTION BOXES, EXTERNAL WATER SUPPLY, SERVICING OF DG SETS, TRIMMING OF TREES AND MISC WORKS AT PCDA (ARMY) COMPLEX UNDER GE (AF) JAMMU
2025_MES_712425_1
CA NO GE/AFJ-16/2025-26
Open Tender
Civil Works
Item Rate
180 days
JAMMU
pls refer tender document
8 documents required · 8 mandatory
₹500
GE AF JAMMU
₹35,000
Yes
29 Aug 2025
4 Jun 2025
9 Jul 2025
4 Jun 2025
3 Jul 2025
19 Jun 2025
Amount
EXTERNAL ELECTRIC SUPLLY Taking out of old unserviceable PVC under ground LT cable of any size and type fixed on pole, wall or laid in floors, trenches, across road crossing etc ,including taking out of cable covers of precast PCC / RCC slab or brick cover etc setting aside serviceable materials in safe custody for reuse and or unserviceable materials consider as schedule of credit complete all as specified and as directed. Note:- i). Dismantling of clamps nuts bolts etc, taking out of GI pipe in cable protection shall be measured and paid seperately under respective item of this schedule. ii).Cost for making good the disturbed surfaces of floors / walls in cement mortar 1:3 shall deemed to be included in the unit rate quoated . However cost for making good the disturbed surfaces of roads with PCC and hard core filling is out of scope of this work and shall be measured and paid separetely
Supply , laying , commissioning UG cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm, 4 core cable complete all as specified and directed by Engr-in-Charge.(Make Havells /Polycab/Gloster/KEI)
dito as per item No-02 but size 16 sq mm, 4 core.
dito as per item No-02 but size 25 sq mm, 3.5 core.
dito as per item No-02 but size 35 sq mm, 3.5 core.
dito as per item No-02 but size 50 sq mm, 3.5 core.
dito as per item No-02 but size 70 sq mm, 3.5 core.
Supply and laying of DWC (Double wall corrugated) HDPE pipe, ISI marked, IS-14930 Part-II, having outer dia as 90 mm and inner dia as 76 mm, with smooth internal surface and profiled external surface for non pressure under ground cable including all connected accessories/fittings such as coupler, 'O' ring, etc. for protection of under ground cable complete all as specified and directed by Engr-in-Charge. MAKE: Rex-Polyextrusion/Gemini or E-in-C's approved make.
Supply and laying of DWC (Double wall corrugated) HDPE pipe, ISI marked, IS-14930 Part-II, having outer dia as 77 mm and inner dia as 63 mm, with smooth internal surface and profiled external surface for non pressure under ground cable including all connected accessories/fittings such as coupler, 'O' ring, etc. for protection of under ground cable complete all as specified and directed by Engr-in-Charge. MAKE: Rex-Polyextrusion/Gemini or E-in-C's approved make.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in any type of soil for laying of LT UG cables complete. Note:- The Rate quoted deemed to including cutting and removal of PSP Sheets wherever occured during excavation and the same shall be staged at desired location as directed at site
Returning, filling in, including spreading levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed by Engr-in-Charge.
Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engr-in-Charge.
M & L for Cutting through existing road surfaces i.e. surfacing PCC soling etc, and making trench of minimum 500mm wide 100cm in depth along the cross section of road for laying of pipes or UG cables, including returning filing in, well ramming & removal of surplus soil to a distance not exc. 50 mtrs & repairs to road surfaces to match with existing including bitumin as required at site all as specified and directed by Engineer-in-charge.
S & F LT cable joint kit straight through heat shrinkable complete with jointing materials suitable for LT Armoured cable 4 core of size 10 to 50 Sqmm all as directed.
S & F LT cable joint kit straight through heat shrinkable complete with jointing materials suitable for LT Armoured cable 4 core of size 70 to 120 Sqmm all as directed.
Labour only for cutting of existing burnt/damaged cable after disconnecting from existing position ,extending the cable from cable loop including neccesory earth work and reconnecting the same all as specified and directed by Engineer-in-charge.
S&F Al thimbles in replacement for LT cables of size 16 to 25 Sqmm
S&F Al thimbles in replacement for LT cables of size 70 to 90 Sqmm
S&F PVC insulated sheathed service wire twin core 10 Sqmm aluminium solid conductor 1100 volts grade incl taking down old unserviceable one complete all as specified and directed by Engr-in-Charge.
S&F in replacement change over switches off-load 630 Amps 4 pole sheet metal enclosure complete all as specified and directed.
S&F MCCB 400 Amps 4 pole 36 KA with adjustable thermal and fixed magnetic setting, fixed in repairs complete all as specified and directed.
S&F MCCB 250 Amps 4 pole 36 KA with adjustable thermal and fixed magnetic setting, fixed in repairs complete all as specified and directed.
S&F MCCB 200 Amps 4 pole 36 KA with adjustable thermal and fixed magnetic setting, fixed in repairs complete all as specified and directed.
S&F in replacement MCCB 160 Amps 4 pole 36 KA adjustable thermal and fixed magnetic setting, complete all as specified and directed.
S&F in replacement MCCB 3 pole of capacity 63 Amps AC 415 Volts Confirms to IS/IEC 60947-2, Breaking capacity 16 KA, positive isolation, thermal magnetic release, adjustable overload 70-100%, adjustable short circuit 5-10 In all as specified and directed.
S&F in replacement MCCB 3 pole of capacity 100 Amps AC 415 Volts Confirms to IS/IEC 60947-2, Breaking capacity 16 KA, positive isolation, thermal magnetic release, adjustable overload 70-100%, adjustable short circuit 5-10 In Make : as per existing panel or its equivalent in Siemens/Legrand/ Schineder/ Hegar/ ABB all as specified and directed.
S&F in replacement MCCB 3 pole of capacity 125 Amps AC 415 Volts Confirms to IS/IEC 60947-2, Breaking capacity 16 KA, positive isolation, thermal magnetic release, adjustable overload 70-100%, adjustable short circuit 5-10 In all as specified and directed.
M & L for Servicing of DG sets of capacity 63 kVA and 320 kVA including carrying out maintenance and check alongwith following repairs :- (i) Drain out the lubricating oil from sump and refilling after proper cleaning of sump. (ii)Replace Engine Oil filter cartridge with New one. (iii)Replace fuel filter cartridge with New one. (iv)Check tightness of all nuts and bolts. (v) Check adjustment of V belt for driving engine water pump and alternator. (v) Cleaning of fuel tank as required (vi) Assembling complete old serviceable parts and replacement of old unserviceable parts by new one as per direction of Engineer-in-Charge (vii)Testing of DG set after servicing as per Engineer-in-Charge. (viii) Cleaning of air cleaner filter and renew after period two hundred hrs run of DG Set or as recommended by Engineer-in-Charge and contractor shall be responsible to carry out the maint/servicing where require time to time and for which no extra payment shall be permitted. (ix) Any parts/Engine oil required to be replaced during servicing of engine shall be measured and paid for separately. (Note : Service of DG Sets 63 KVA and 320 KVA - 2 Nos. All spare required for replacement shall be supplied under following items).
Note:-(i) Any minor parts such as screws, washers , split pin , circlip, cotton waste, etc shall be supplied by the firm, rate for the same shall be deemed to be included in the unit rate quoted. (ii)The Job shall be carried out after two hundred hrs run of DG Set or as recommended by Engineer-in-Charge and contractor shall be responsible to carry out the maint/servecing where require time to time and for which no extra payment shall be permitted. (iii) Any parts required to be replaced during servicing of engine shall be measured and paid for separately.
Supply Only the following parts suitable for 63 kVA and 320 KVA DG sets: -
Oil filter Cartridge Make of DG set : Kirloskar/Greaves/ Cummins/Ruston/Micco/Fleet Guard
Fuel filter Cartridge pre and fine both as required at site. Make of DG Set-Kirloskar/Greaves/Cummins/Ruston/Micco/Fleet Guard
Air cleaner filter Cartridge, Make of DG Set: Kirloskar/Greaves/ Cummins/Ruston/Micco/Fleet Guard
Radiator hose pipe, Make of DG Set: Kirloskar/ Greaves/ Cummins/ Ruston
Fan belt complete for DG set Make- Kirloskar/ Greaves/Cummins/Ruston/Fenner
Turbo oil pipe, DG Set makeMake: Kirloskar/ Greaves/Cummins/ Ruston
Fuel pipe heavy duty, DG Set Make: Kirloskar/Greaves/ Cummins/ Ruston
Battery terminal of brass heavy duty type as per existing sample
Solenoid Switch, DG Set Make: Kirloskar/ Greaves/TVS Lucas
Oil drain pipe heavy duty, DG set Make: Kirloskar/ Greaves/Cummins/ Ruston
Water pump assy, DG Set Make: Kirloskar/ Greaves/Cummins/ Ruston
Copper battery lead 3 mtr long 16mm dia multi stranded, DG Set Make: Kirloskar/ Greaves/Cummins/ Ruston
DG set rubber coupling for 63/320 KVA, DG set Make: Kirloskar/Greaves/ Cummins/Dunlop
Supply only Coolant Make- Castrol or As per the recommendation of Kirloskar/Greaves/Cummins
Supply only Turbo lubricant oil 15W-40 Make: Castrol or as per the recommendation of Kirloskar/Greaves/ Cummins
Repair/servicing Self startor 12/24 volts incl replacement of wornout part such as carbon brush, bentex pinion, bushes, carbon brush holder, solinoid and refixng complete set to work of 63 to 320 KVA DG sets
Repairng of battery terminals complete including opening connection ,transportation and re-fixing the in orginal position .
S&F in repair LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including making electric connections using two run of 1.5 sqmm single core unarmoured wire from junction box, fixed in repairs,CA No also engaved on street light complete all as specified and as directed by Engr-in-Charge. Make: Crompton or eql in Phillips/Wipro
S&F in repair LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including making electric connections using two run of 1.5 sqmm single core unarmoured wire from junction box, fixed in repairs,CA No also engaved on street light complete all as specified and as directed by Engr-in-Charge.
S&F LED Flood light fitting 120 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including making electric connections using two run of 1.5 sqmm single core unarmoured wire from junction box, fixed in repairs,CA No also engaved on street light complete all as specified and as directed by Engr-in-Charge.
Taking out burnt winding with allied insulation materials of servo stabilizer (50 to 200 KVA) including M&L for rewinding of stabilizer of above capacity with super enamelled copper winding wire of appropriate gauge and cleaning of rust, carbon deposit etc. complete all as spd and dir by EIC
Supply and Replacement of electronic sensing control card circuit plate as per sample
Replacement of dimmer stat 350 Amp Suitable stabilizer
Supply and replacement of Servo motor of capacity 10 Kg-cm.
Replacement of Carbon Bushes
Replacement of Copper leads size 02 No from Stablizer to main panel
Reassembling of voltage stabilizer complete including provn of new gasket making all connections including proper thimbles of appropriate size and testing complete of voltage stabilizer by using out side dimmer unit for low and high out protection
Supply and pouring transformers oil for transformer 63 to 500 KVA topping with the die electric strength of 45 KV complete including dehydration of old used oil all as specified and directed.
M&L for top cover gasket as per required size of 63 to 500 KVA transformer
M&L for LT bushing gasket as per required size of 62 to 500 KVA transformer
Aluminium conductor, steel reinforced of any size on LT Poles including straining, binding with insulators with Al/copper binding wire with insulators as in OH conductors, providing PVC Sleeves for jumper and entire satisfaction of Engnr-in-Charge complete all as specified and directed .
Cutting wild grasses,bushes,creepers,unwanted vegetations, etc. from surrounding poles/stays including cleaning cripper climbed on poles as and when directed and removing the spoil and deposit where directed (size of cutting 90x90 cm around pole/stay) entire satisfaction of Engnr-in-Charge complete all as specified and directed . Note:-The Item shall be operated maximum three times in the entire period of the contract.
Trimming of tree branches to clear the HT/LT OH lines girth of tree branches exc 25 mm and not exc 50 mm and stacking the materials where directed to a distance not exc 50 mtr and clearing the site upto entire satisfaction of Engnr-in-Charge complete all as specified and directed .
All as per Item No-64 here-in-before ,but girth of tree branches exc. 51mm and not exc.100 mm.
Supply and fix in repair HT 11 KV, out door type gang operated air-break switch suitable for horizontal or vertical mounting fixed type complete with 09 insulators of rating upto 200 Amps all as specified and directed.
Dismantling air break gang operated switches vertical/horizontal mounted including insulators and operating mechanism for repair/ replacement of broken/worn out components and insulators etc. or carrying to MES store (spare/components for replacement to be provided under item-66)
Supply and fix in repair Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp HT 11 KV all as specified and directed by Engineer-in-charge.
Supply and errect in replacement steel tubular swaged poles complete with MS base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11 metres long) conforming to IS 2713 including applying two coats of aluminium paint over a coat of red oxide zinc chrome primer over the exposed surface and applying two coats of black bituminous paint over the embeded portion of pole, errecting in truly vertical position complete including taking down old U/S pole all as specified and directed. Note-Required cement work and PCC to be done as specified in SSR Part-1 and shall be included in quoted rate.
M&L for Earthing complete with GI earth plate 600 x 600 x 6 mm thick buried directly in ground (earth pit not less that 2.25mtr deep below ground level ) with top edge of the plate not less than 1.5 m below normal ground level connected to 32x6 mm GI strip as earthing lead by means of brazing after tighten by bolts, nuts, check nuts and washers from earth pit to test point with protection GI pipe of size 50mm dia light grade and providing masonry enclosure including watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 20 mm GI pipe light grade for earth strip protection complete with earth pit in PCC 1:2:4 type B0 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work in any type of soil, returning filling in and removal of surplus soil complete all as specified and as directed. Note: GI strip 7.5 mtr included in the quoted rate from earth pit to test point.
EXTERNAL WATER SUPPLY
M& L for removing bore well column pipes upto 150 mm dia with submersible flat cable of any type and dismantling and taking up/down Submersible Pump and Motor assembly of capacity 20 HP, shifting to workshop and removing unserviceable spares, replacing with new spares such impeller, bushes distance bush, seal etc of same specifications / type / model. removing burnt copper winding from motor and rewinding with same guage and type of insulation copper conductor winding wires and insulation sheets , applying insulating varnish over the complete winding , drying up by heating , assembling back and testing for proper function including necessary machining works as required , bringing back and reinstalling into the bore well all as specified and as directed.
Supply,laying 15mm bore steel water tubing medium grade galvanised with all fittings including short lengths, laid in trenches, complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) including taking down old unserviceable pipe any type complete all as specified and as directed by Engr-in-Charge.
Supply,laying 20 mm bore steel water tubing medium grade galvanised with all fittings including short lengths, laid in trenches, complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) including taking down old unserviceable pipe any type complete all as specified and as directed by Engr-in-Charge.
Supply, Laying 25 mm bore steel water tubing medium grade galvanised with all fittings including short lengths, laid in trenches, complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) including taking down old unserviceable pipe any type complete all as specified and as directed by Engr-in-Charge.
S&F 40 mm bore steel water tubing medium grade galvanised with all fittings including short lengths, laid in trenches, complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) including taking down old unserviceable pipe any type complete all as specified and as directed by Engr-in-Charge.
S&F 50 mm bore steel water tubing medium grade galvanised with all fittings including short lengths, laid in trenches, complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) including taking down old unserviceable pipe any type complete all as specified and as directed by Engr-in-Charge.
S&F 100 mm bore steel water tubing medium grade galvanised with all fittings including short lengths, laid in trenches, complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) including taking down old unserviceable pipe any type complete all as specified and as directed by Engr-in-Charge.
Note for item no. 73 to 78 : Excavation and earth work shall be measured and paid seperately under relevant items
Supply , laying, jointing & testing of DI Type K-7 pipe, 100mm dia, with socket & spigot ends, with cement morter zinc coated out side as per IS 8329/2000 in standard length suitable for and including push on tyton joints with rubber rings, laid in trenches, including taking up or down old unserviceable water mains (including all fittings) complete all as specified and directed by Engr in charge.
Supply , laying, jointing & testing of DI Type K-7 pipe, 150mm dia, with socket & spigot ends, with cement morter zinc coated out side as per IS 8329/2000 in standard length suitable for and including push on tyton joints with rubber rings, laid in trenches, including taking up or down old unserviceable water mains (including all fittings) complete all as specified and directed by Engr in charge.
Note for Item No. 80 & 81: Excavation and earth work shall be measured and paid seperately under relevant items
M& L for MS/CI/DI fittings such as collar, bends, any type, any dia, any radius, any angle, double end socketted or double flanged or spigot & socket, tail pieces, all socketed or all flanged with an equal & other end tapering bellmouth or flanged plates, connecting pieces straight, both end flanged or socketed of socket & flanged & spigot ends or bellmouth tailpieces, one end flanged & other end spigot or socket or tatering as bell mouth or flanged, caps blank flanges heavy duty suitable for mechanical joint/flanged joint with and including taking down old fitting of any type and any size all as specified & directed by Engineer In Charge Note: Certifiacte for Weight of fitting by the manufacturere shall be submitted before payment.
M & L for mechanical type joint made of MS sheet of size 6/8 mm thick along with rubber gasket nuts bolts and washers suitable for 100 mm bore dia of CI/DI pipe complete all as specified and as directed.
M & L for mechanical type joint made of MS sheet of size 6/8 mm thick along with rubber gasket nuts bolts and washers suitable for 150 mm bore dia of CI/DI pipe complete all as specified and as directed.
S&F Gun-metal, globe or gate valves, IS:778 marked, with iron wheel head, screwed both ends for iron pipe of size 20mm, fixed in repairs, complete all as specified and as directed by Engr-in-Charge
S&F Gun-metal, globe or gate valves, IS:778 marked, with iron wheel head, screwed both ends for iron pipe of size 25mm, fixed in repairs, complete all as specified and as directed by Engr-in-Charge
S&F Gun-metal, globe or gate valves, IS:778 marked, with iron wheel head, screwed both ends for iron pipe of size 50mm, fixed in repairs, complete all as specified and as directed by Engr-in-Charge
S&F Bib taps , fancy type cast copper alloy, chromium plated, with crutch or butterfly handle screwed down for iron pipe or for brass ferrule for bore of pipe 15 mm, fixed in repairs, complete all as specified and as directed by Engr-in-Charge
Attending day to day emergency breakdowns / complaints of damaged water supply lines of 15 mm to 150 mm bore in distribution system and restoration of water supply by stopping the leakage occured by deputing skilled /semi skilled man power for smooth functioning of water supply, complete all as specified and directed by Engineer-in-Charge.
Note for serial item No. 90 : - (a) Up to 0.50 Cum of the earth work shall be included in the job & more than 0.50 Cum shall be measured and paid separately. (b) The complaint / breakdown shall be rectified by the contractor within 24 Hours. Any delay thereafter, recovery at double the rate quoted per job shall be deducted from the dues of contractor by the Enginer-in-charge without any notice. (c) A proper record of complaint slip shall be maintained by the Engineer-in-Charge for making the payment against these items and recovery if any in case of failure of attending and rectifying the complaint within 24 hours. (d) Two pipe fitter and two helper with required T&P shall always be made available for attending complaints. (e) All material such as bends, unions, nipple, tees, sockets of suitable size and all other items rate includes each job. MES not given any material and not paid seperately
S&F and testing CI sluice valves, 150 mm dia, both ends flanged and drill in with brass spindle and brass check nuts, hand wheel made out of CI complete suitable for tested hydrostatic pressure 15 Kg/Sqcm. (PN 1.6) and confirming to IS 780, including taking out of existing unserviceable valve complete all as specified and directed by Engineer-in-Charge.
S&F and testing CI sluice valves, 100 mm dia, both ends flanged and drill in with brass spindle and brass check nuts, hand wheel made out of CI complete suitable for tested hydrostatic pressure 15 Kg/Sqcm. (PN 1.6) and confirming to IS 780, including taking out of existing unserviceable valve complete all as specified and directed by Engineer-in-Charge.
S&F cast iron non return valve heavy duty ISI marked, 150 mm bore, with jointing material flanged joint rubber gasket 6mm thick nuts,MS nuts, bolts, washers including taking out of existing unserviceable complete all as specified and directed by Engineer-in-Charge.
M & L for carry out water quality anyalsis for bacterial , chemical and biological analysis including for collection of water samples from Pump house PCDA (NC) as specified by Engineer-in-charge and testing from Govt approved testing laboratory , submitting of report from minimum following parameters. (a) Free chlorine (b) pH (c) Total Hardness (d) Total Alkalinity (e) Bacterological standards (f) Chemica standars (g) physical standards (h) copper (i) chloride . Notes: 1. Saperate water samples should be collected & tested for Each location as specified above 2. No payment shall be made to contractor till submission of water test report for the water samples of locations mentioned above
M&L for cleaning of valve pit chamber removing sludge deposited inside chambers,removing sliuce valve changing packing rope and also spindle,clearing of all leakages from chamber complete all as specified and directed by Engineer In Charge
SCHEDULE 'A' PART-II (Schedule of credit) Credit amount of Rs (Refer schedule of credit) for retrieved material mentioned in Sch 'A' Part-II of Tender documents in PDF form will be deducted offline during acceptance of tender of lowest bidder.
Pyramid constructions (BID ID -3337773)
M/S VIDYA ENTERPRISES (BID ID -3337105)
ASHOKKUMAR SURI (BID ID -3337923)
M/S RAJ ENGINEERS (BID ID -3337263)
ANIKET TRADERS (BID ID -3341284)
G M ENGINEERING SERVICES (BID ID -3338211)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .