| 1 | L-1₹7.0 CrAccepted-AOC F 31 INDUSTRIAL AREA PHASE VIII SAS NAGAR MOHALI 160071 | S A S NAGAR | PUNJAB | 160071 | ₹7.0 Cr | L-1 | Accepted-AOC Accepted |
| 2 | Not Admitted-Fee/PreQual/Technical WHITE VILLAH VPO KALCHIYAN AMRITSAR | AMRITSAR | PUNJAB | 143001 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹6.6 Cr
EMD Value
₹7 L
Closing Date
4 Jan 2020, 5:00 pmClosed
Executive Engineer
Executive Engineer Water Supply and Sanitation Division No 2 Amritsar
CONSTRUCTION OF MAIN PUMPING STATION 9.0 MLD and STP 2.80 MLD BASED ON ANY SUITABLE SUTAINABLE AND PROVEN TECHNOLOGY INCLUDING O and M FOR 5 YRS AFTER COMMISSIONING IN VILLAGE BUDHA THEH BEAS and ABADI GURUNANAKPURA BLOCK RAYYA Distt. Amritsar
2019_WSS_41692_1
STP BUDHA THEH 5238-68 dated 9.12.2019
Open Tender
Civil Works
Item Wise
365 days
Amritsar
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
TIA
₹7 L
Chief Engineer North
12 Mar 2020
10 Dec 2019
6 Jan 2020
10 Dec 2019
4 Jan 2020
10 Dec 2019
17 Dec 2019
Amount
Excavation in trenches with straight or open cutting in streets, lanes or in open area with 3D/JCB or excavator including manually dressing bed, trimming sides and side slopes for sewers and manholes to full depths as shown in drawings,including, dressing to correct sections and dewatering, provision for diversion for traffic, protection of existing services i.e. telephone cables, electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, watching, etc., fixing and maintenance of caution boards, fencing, refilling trenches, watering, ramming and restoration of surface to original level and removal of surplus spoil from the site of works, upto one chain (15m) complete in all respects. a) For depth not exceeding 3.0 mt. below ground level for all kind of soil except rocky.
For depth exceeding 3.0 mt. bot not exceeding 4.5 Mt. BGL for all kind of soil except rocky.
Providing & fixing timbering on face of trenches if required for sewer & manholes for item no.29.4 and 29.5 irrespective of depth measuring each timbered surface of trench on which timbering is done Type-I simple type timbering
For trench having width up to 1.0 Mtr.
For trench having width above 1.0 Mtr. up to 2.0 Mtr.
Exra for filling earth in 15 cm layers and compaction.for item 29.1 & 29.2
Extra for disposal of surplus spoils/ earth earth if any beyond 15 metre as covered in item No. 29.1 to 29.5 (Lead up to 1 Km)
Cement Concrete 1:8:16 with 40 mm gauge stone aggregate using concrete mixing volumetric type
Cement Concrete 1:6:12 with 40 mm gauge stone aggregate using concrete mixing volumetric type
Cement Concrete 1:2:4 with stone ballast or shingle using concrete mixing volumetric type
Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure.
First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level.
12.5 mm thick cement plaster in 1:2
Cement Plaster 20 mm (1:2)
Cement rendering on plaster 1mm thick.
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
Centring and shuttering for faces of walls, partitions, retaining walls and the like (vertical or bartering including attached pillasters buttersses etc
Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
Providing, lowering, in trenches to correct gradient ande alighnments ,joining with tyton rubber joint and cutting of RCC S&S pipes having inside HDPE linning ISI marked as per ISI 458-2003 into trenches for all depths and laying out the same to correct alighnment , gradients, levels etc. cutting of concrete beds and joints hole ,supporting the pipes & specials in correct position in asuitable rigid manner while the same are being jointed and untill the surrounding benching,haunches and envelops are completed. Pipe shall rest on the beds at all joints through their lengths and to ensure this, testing the pipe for leakage and making good the same leakage & all defects to the entire satisfaction of the engineer- in- charge including all cartage etc. complete in all respects RCC pipes with inside HDPE linning Class NP3
400 mm i/d pipes
Providing & fixing 560 mm, 500 mm and 450 mm internal diametre circular or 450 mm x 600 mm clear inside opening rectangular RCC manhole cover and frame ISI marked as per IS:12592-2002 including carriage from the stores of the Engineer-in-charge to site of work, loading, unloading including stacking and setting the same to correct lines over manholes including cement concrete copping (M:20) around the frame etc. Dia of steel for lifting hook is 16mm. (for EHD and HD).
560 mm i/d (heavy duty)
Providing orange colour safety footrest of minimum 6mm thick plastic encapsulated as per IS:10910 on 12mm dia steel bar confirming to IS: 1786 having minimun cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruted legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacturer's permanent identification mark to be visible even after fixing, including fixing in manholes with 230x150x75cm cement concrete block 1:2:4 (1 cement: 2 sand: 4 stone aggragate) complete as per design.
Cold twisted detormed (Ribbed/ ToR s teel Bar) Bars (Fe 500 grade as per IS 1786-1985) , for R.C.C works, where not including in the complete rate of RCC including bending and biding placing in position complete
Floating coat of 1.5 mm thick neat cement laid in one operation to the topping
40mm thick c:conc 1:2:4 with 3mm neat cement coat
Add difference of rate of bricks in Amritsar Dist. Distt.
Add difference of rate of Steel (From Primary Producer e.g SAIL/Jindal/Tata Etc
Carriage of Material such as sand (Lead 128Km)
up to 40 K.M.
41 K.M. to 60 K.M.
61K.M. to 128 K.M.
Carriage of Material such as Bajri (Lead 128Km)
up to 40 K.M.
41 K.M. to 60 K.M.
61K.M. to 128 K.M.
Providing and fixing Indef make electric operated Gantry Crane of 3.0 MT capacity
Prov. & Fixing elect. Driven Non clog centrifugal pump set capable of delivering 1610 LPM at 10.0 Mtr head Complete in all respect.
Prov. And fixing sluice gate for screening chamber a per specifications of size 400m x 600 mm complete in all repects (of Aluminium)
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer in-charge). Special quality Sluice Valve (PN 1.0/1.6) of premium range such as make kirlosker as approved by Engineer-in-Charge.
200 mm i/d Sluice Valves flanged
300 mm i/d Sluice Valves flanged
Supplying and laying D.I. specials/fittings as per IS:9523-2000 (ISI marked with the prior approval of Engineer-in-Charge), class K-12 suitable for tyton joint with external bitumen coating and inside cement mortar lining, scaffolding, tools and plants, ropes, guys, etc. Complete in all respects. (Up to 300 mm i/d)
Providing, Stringing out, cutting, Jointing and testing of ISI Marked D.I. Double Flanged pipes with screwed flanged as per IS:8329-2000, Class-K9 and laying the same in trenches to correct alignment and gradients,jointed with nut bolts and rubber insertion joints fitted complete including all cartage.
200mm i/d pipe line laid complete
300mm i/d pipe line laid complete
Providing, Stringing out, cutting, Jointing and testing of ISI Marked D.I. Pipe (S&S) as per IS 8329 and laying the same in trenches to correct alignment and gradients, jointed with rubber tyton joints fitted complete including all cartage. D.I. Pipe as per IS 8329 DI-K9
200mm i/d pipe line laid complete
Embedding100 mm dia CI rain water non pressure ISI mark pipe in cement mort during masonery work.
Earth work in excavation in Foundations Trenches etc., for storage and sedimentation tanks, high level tanks, filter
50mm thick ironite (Metallic Floor Hardener to be mixed with Granolithic topping for heavy duty floors)
115 mm thick brick wall laid in cement sand mortar 1:4 without reinforcement in super structure
12.5 mm thick cement plaster in 1:4
Cement pointing (1:2) deep variety
Supplying and fixing rolling shutters, of approved make, made of 80mmx1.25mm, M.S. Laths, interlocked together through their entire length and jointed together , at the end, by and locks, mounted on specially designed pipe shaft, with brackets, side guides, 27.5cm long wire spring grade No. 2 and arrangement for inside and outside locking with push and pull operation complete, including top cover 0.80mm thick (payment is to be made for the exect size of opening where rolling shutter is to be fixed)
Supplying and fixing of Pressed steel sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiveing tower bolts and finished with 2 coats of ready mixed painted lead non setting primer of approved quality, fixed in position including the cost of cement concrete 1:3:6 for fillings in the frame and cement concrete 1:2:4 for lugs comple
Supplying openable steel windows, of standard rolled steel Z sections, joints mitred and Electrically flash-welded, with iron fittings incluidng necessary iron handles, Peg-stay catchers bolts, iron plugs and pressed steel projected hinges and glazing clips, complete (Excluding glazing ) and finished with two coats of ready mixed paint red lead non setting primer
Terracing consiting of tiles 22.86x11.43x 3.83cm laid in Cement sand morter (1:3) including 6mm thick cement plaster (1:4)on top with two coats of hot bituman with 10 cm mud and two layers of 25mm mud plaster asper item of CSR
Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make. Glass panes 4mm thick above 0.40 sqm area.
Providing and fixing stair case railling made out of M.S. Square bars 20x20m as vertical cost 0.70 metre high fixed with M.S. Base plate of 40mx40mmx6mm and flat iron 40mmx6mm as hand rail complete in all respects.
Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars rivetted of molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position
Finishing walls with exterior decorative cement based paint such as snowcem, robbiacem etc. two or more coats to give an even shade
White washing (Three coat)
Applying priming coat with metal primer on new steel or iron work including preparation of surface.
Nuts and Bolts of all sizes for fixig flat. & Specials
Top Khurra of 0.60xo.60 m for rain water pipe as per item of CSR
Bottom Khurra of 1.20x0.60 m consisting of brick on edge in C.S (1:3), 75mm c.conc. (1:8:16) including 12.5 mm thick cement plaster (1:3)
Wiring in insulated copper conductor single core FRLS cable ( ISI MARKED) 1100 volts grade to be laid in heavy guage ewlded conduit pipe 20mm/25mm dia (1.6 mm thick ISI marked ercessed in wall etc. complete with powder coated/anodized concealed metal box asper Item of CSR . i) Fan point
Wiring in insulated copper conductor single core FRLS cable ( ISI MARKED) 1100 volts grade to be laid in heavy guage ewlded conduit pipe 20mm/25mm dia (1.6 mm thick ISI marked ercessed in wall etc. complete with powder coated/anodized concealed metal box asper Item of CSR (i).Wiring light points
Wiring in insulated copper conductor single core FRLS cable ( ISI MARKED) 1100 volts grade to be laid in heavy guage ewlded conduit pipe 20mm/25mm dia (1.6 mm thick ISI marked ercessed in wall etc. complete with powder coated/anodized concealed metal box asper Item of CSR (i) Wiring 3 Pin 6 Amp wall sockets
Wiring in insulated copper conductor single core FRLS cable ( ISI MARKED) 1100 volts grade to be laid in heavy guage ewlded conduit pipe 20mm/25mm dia (1.6 mm thick ISI marked ercessed in wall etc. complete with powder coated/anodized concealed metal box asper Item of CSR (i) Wiring 3 Pin 16/20 Amp power plug control
Proving & fixing ISI Marked Non-return valves flanged end class PN-1.0 as per IS:5312/2004 in pipe lines including jointing & cost of Nut Bolt , rubber insertion etc. complete.
Extra for mech. Vibrator used by contractor at his cost
Providing, lowering in trenches to correct gradient and alignment, jointing with tyton rubber joint and cutting of reinforced cement concrete spigot and socketed pipes and specials with rubber ring ISI marekd as per IS code IS 458-2003 into trenches for all depths and laying out the same to correct alignment, gradients, levels etc. cutting of concrete beds and joints holes, supporting the pipes and specials in correct position in a suitable rigid manner while the same are being jointed and until the surrounding benchings, haunches and envelopes are completed. The pipes shall rest on the beds at all joints through their lengths and fixing of rubber ring, facing, testing the pipes for leakage and making good the same leakage and all defects to the entire satisfaction of the Engineer-in-charge including all cartage etc. (e) 300mm i/d
Structual steel work in angles, tees, flats, rivited, including cutting, fixing all guset plates, bolts, nuts, rivets etc. with hoistng and erecting in position.
For roof Trusses,well currbs,plates & trussed girders,etc of any spanfor building and bridges upto 15 m span
Survey, Soil testing, Design, Supply and construction, Installation, Commissioning of STP (2.80 Mld) based on any suitable, sustainable and proven technology including other appurtenant works on turnkey basis . (As per scope, terms, Condtions & specifications attached) including installation of Transformer, Gen.set of suitable capcity for STP & MPS, SOLAR ENERGY BASED POWER PLANT (50 KW capacity)., Operation & Maintenance of Main Pumping Station (9.0 Mld) & Sewage Treatment Plant of 2.8 Mld for 5 years after commissiong Complete
Extra for Structural design of MPS
Construction Of Hatch Box of size 0.90x0.90 M x1.5M complete in all respect
Less difference of rate of sand in Amritsar Dist..
Less difference of rate of bajri in Amritsar Dist..
Less difference of rate of Cement
Credit of Sludge
Average Daily Guaranteed power consumption for MPS ( 9.0 MLD) & STP (2.80 MLD) Both
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .