Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
Tender Value
₹12.8 L
EMD Value
₹25,600
Closing Date
19 Jan 2024, 3:00 pmClosed
XEN STD Kathua
Office of the XEN STD Kathua
Installation of Protection Devices at LIS Lakhanpur under Recapitalization/Rejuvenation of 05MVA, 66/6.6KV Power Transformer LIS Lakhanpur on Turnkey Basis
2024_PDD_241907_1
STD-III/e-NIT/2023-24/19 Dated 03.01.2024
Open Tender
Electrical Works
Turn-key
30 days
Kathua
A-Class Electrical Contractor, GST Clearance, PAN Card, Experience of Same works, tunover certificate
7 documents required · 7 mandatory
₹1,180
XEN STD Kathua
₹25,600
XEN STD Kathua
10 Feb 2024
3 Jan 2024
20 Jan 2024
3 Jan 2024
19 Jan 2024
3 Jan 2024
3 Jan 2024 - 8 Jan 2024
8 Jan 2024
Amount
Installation of Protection Devices at 66/6.6KV Receiving Station LIS Lakhanpur
66KV SF6 Breaker designed for 72.5 KV 1250 Amp, 31.5 KA 3-Phase, out door type circuit breaker along with support structures, marshalling box terminal connectors and required accessories complete as per technical specification, scope of work & approved drawings confirming to IS standards
SITC of new 66KV CT Set including dismantling of damaged 66KV CT Set
SITC of new 66KV LA Set including dismantling of damaged 66KV LA Set
SITC of new 66KV Post Insulator Set including dismantling of damaged 66KV Post Insulator Set
SITC of 12 core control cable
SITC of 06 core control cable
SITC of 02 core control cable
SITC of Lugs, Ferrules, etc.
SITC of ACSR Panther Conductor
SITC of T-Clamps
SITC of CT-Clamps
SITC of GI Nut and Bolt of sorts
SITC of Plate Earthing using GI strip of size 50x6mm welded with hot dipped Galvanised Plate of size (600x600x6)mm, to be connected to 11KV Panel, LA and outgoing structure through GI strip. The rate includes excavation of earthing Pit of 3 meter depth, disposal of excavated earth from site of earthing to outside to out side station. And backfilling should be using Good Earth, Charcoal Dust and Salt. Also. the rate should include provision of curing of earth plate using GI Pipe of size 50mm with length of 3 Mtr (ISI Marked) and making of chamber at the top with funnel and chamber cover (complete job).
SITC of 3 Over current & 1 Earth Fault Relay
SITC of Master Trip Relay
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .