Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.6 LAccepted-AOC | L1 | Accepted-AOC Awarded being lowest bidder | |
| 2 | L2₹21.1 L+₹2.0 L (10.2%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹21.2 L+₹2.1 L (10.9%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹21.4 L+₹2.3 L (11.8%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹23.4 L+₹4.3 L (22.5%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
₹31 L
EMD Value
₹62,000
Closing Date
14 Mar 2020, 6:00 pmClosed
Garrison Engineer NorthAhmdnagar
Military Engineer Service Garrison Engineer North Nagar-Pathardi Road Opp Ahmednagar Fort Ahmednagar - 414 002
Repair Replacement of exinstering LT Electrical System including LT UG cables MCCBs LT panel change over switches in Bldg under GE (N) Ahmednagar
2020_MES_322609_1
8404 / E8
Open Tender
Miscellaneous Works
Item Rate
270 days
Ahmednagar
Class D Cat b (i)
8 documents required · 8 mandatory
₹500
Yes
Garrison Engineer North Ahmdnagar
₹62,000
Yes
20 Mar 2020
7 Feb 2020
16 Mar 2020
7 Feb 2020
14 Mar 2020
22 Feb 2020
Amount
Dismantling carefully the existing LT overhead line ACSR conductor of any size from its position by necessary disconnecting of conductor and removing complete all as specified and as directed
Dismantling of unserviceable insulator of any type complete from its position and removing all as specified and as directed
Dismantling of unserviceable existing cross arms made from channels, angles and unserviceable FI clamps, nuts, bolts etc from OH line and removing complete all as specified and as directed
Dismantling of existing LT poles carefully of any size and type from its position carefully and removing from the site and necessary excavation and earth work in any type of strata, demolition of concrete, disconnecting of conductor etc all as specified and as directed .
S&F stay assembly complete with accessories as shown in Electrical Plate No 1 of SSR 2009 (Part I) using stay rod 20mm dia, including clamps made out of 50 x 6mm MS flat, MS galvansied stay plate 300mmx 300mm x 6mm and galvanised thimble including insulator 90x140mm all as specified and as directed. (loop type insulator, stay clamps, excavation and concrete shall be measured and paid separately
M&L for prunning and removing of tree branches touching to electric over head lines wild growth around LT /HT over head lines and around pole and stay complete to make clear span of 2 Mtr of tree both side of the OH line with JCB, Cutter and all tools, plants etc all as directed by Engineer-in-Charge. Note : (i) Distance between pole to pole will be measured and paid. (ii) Contractor has to take upmost care to avoid damage to existing lines/structures if Any breakdown of line caused during punning shall be made good without any extra cost. (ii) Prunning of tree to be done twice a year (before & after rainy season) (iii) The contractor has to ensure the proper safety of the tradesmans to avoid any mishappening. If any mishappening occures the contractor will be solely responsible for it.
Supply, erecting and fixing in replacement of true vertical position of steel tubular swaged pole, 9 mtr long complete with cast iron base plate, finial taper plug, bolt, nuts and screws as specified and of type 410 SP-31, conforming to relevant IS, including one primer coat of red oxide and two coats of aluminium paint and two coats of bituminous paint inside and outside of botton portion up to 1.8 mtr length all as specified and provide circular bend 1 No of length 2 m complete all as specified and directed. (Excavation and earth work , foundation concrete and PCC coping shall be measured and paid separately)
M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers etc welding bending cold or hot, drilling holes for bolts , in any shape or size as indicated or directed and inclusive of one coat of red oxide primer, one under coat and one inishing coat of aluminium paint all as specified and as directed.
M & L for replacement of Pin type, porcelain, vitreous, white,brown or green insulator including one galvanised mild steel spindle,two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade
M & L for replacement of shackle Type, Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers,insulator bolts, washers and nuts, 100mm height and 115mm dia including two nos of galvanised steel strap of size 31x5mm fitted with 14mm dia bolts and nuts all as per directed.
Labour for restringing of LT over head line consisting of 4/5/6 conductors retrive from ser item no-01 by dismantling taking down,unserviceable , damged ACSR conductor, repairing wherever required including cutting, re-joining and restringing in, with proper sag, binding to insulator with and including aluminium binding wire complete all as specified and directed. Note : (i) Only good and serviceable conductors are used, unserviceable conductors will be credited to contractor under schedule of credit. (ii) Rate of Transporting of conductor from one site to another site is included this rate.
Supply, fixing and stringing ACSR conductor (Weasel/ Ferret) for over head line securing on pole complete including binding wire, jointing sleeves aluminium tap and PG clamp etc of any size all as specified and as directed. (Note :- (a)jumper on cutout point/2 pole structer/4 pole structure shall be provided with PVC insulated sleeve. (b) Rate is inclusive of jumpers materials & tree branch cutting to make a safe distance from over head line.)
Excavating in trenches n exc 1.5 mtr wide and n exc 1.5m in depth , for foundation ,etc or for shafts, wells , cesspits, main holes etc.n exc 10 sqm on plan and n exc 1.5 mtr depth and getting out on soft/ lose soil and added additional 1.5 m or part thereof in depth beyond the first 1.5 mtr.
All as per ser item no 13 above but hard/ dense soil
Returning, filling in, including spreading , levelling , watering and well ramming in layers not exc 25cm of any soil.
Removing excavated materials(soils) n exc 50m and depositing where directed at a level n exc 1.5m above the starting point.
Supply & lay HDPE pipe 65mm bore for laying of LT cables etc complete with all accessores all as specified and directed
Supply and Laying in trenches or drawn through pipe or fixed on wall / poles , LT UG cable 1100 Volts, heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium conductor after removing old one of following size:-
(a) 10 Sqmm 2 core, Make: Polycab/CCI/Havells/ RR Kabel
(b) 16 Sqmm 2 core, Make: Polycab / CCI / Havells / RR Kabel
(c ) 10 sqmm 4 Core, Make: Polycab / CC I/ Havells / RR Kabel
(d) 16 sqmm 4 core, Make: Polycab / CC I / Havells / RR Kabel
(e ) 25 Sqmm 4 core, Make: Polycab / CC I / Havells / RR Kabel
(f) 35 Sqmm 31/2 core, Make: Polycab / CCI / Havells / RR Kabel
(g) 50 Sqmm 31/2 core, Make: Polycab / CCI / Havells / RR Kabel
(h) 70 Sqmm 31/2 core, Make: Polycab / CCI / Havells / RR Kabel
(j) 95 Sqmm 31/2 core, Make: Polycab / CCI / Havells / RR Kabel
(K)120 Sqmm 31/2 core, Make: Polycab / CCI / Havells / RR Kabel
M/L for GI pipe light grade 40 mm dia Tubes, with all fitting and fixed complete to walls and ceilings or laid in floors complete for protection of cables
All as item No 19 above but 50mm dia tubes.
All as per Item No 19 above but 80 mm dia tubes
M & L for making good the damaged Tar Road by using additional stone metal, PCC etc
Demolation of u/s cement concrete in coppings all as directed.
M&L cement concrete (1:3:6 ) type D2 using graded stone aggregate as in Copping of pole including necessary form work all as specified & directed.
M & L for PCC(1:4:8) type D-2 using 40mm grade stone aggregates as foundation of pole and similar work all as specified and directed.
M & L for repair of LT Panel board of any size with replacing the unserviceable MCCB,MCB,switch fuse unit , change over ,Busbar,etc jointig cable with proper lugs ,nut , bolt and washers, cleaning the panel by using of CRC Soluation and repairing thhe panel door by using hinges and repairing the lock system, welding etc painting the LT Panel wit one coat of primer & two coat of synthetic enamel paint as approved or as per direction of Engr-in-Charge. Note:(i) MCCB,MCB,Switch fuse unit and change over switch measured and paid separately. change over switch measured and paid separately. (ii)Rate of new Busbar, lugs,CRC Solution,nut,bolt, painting etc and washers are deemed to be included in quoted rates.
Supply and fixing in replacement of MCB TPN 63 Amps with breaking cap 16 KA and connecting all as directed . Make : Legrand Cat Part No DPX3 160,420003 of its equvalent in L&T/Siemens.
All as per item No 27 here in above but 40 Amps MAKE: Legrand Cat Part No DPX3 160 420002 of its equvalent in L&T/Siemens / Standard
Supply and fixing in replacement of MCB DP, 40 Amps with 10 KA breaking / rupturing capacity including neccssary connection complete all as directed. MAKE: Legrand Cat Part No DX3MCBs 408637 of its equvalent in L&T/Siemens./ Standard
All as per item No 29 here in above but 20 Amps MAKE: Legrand Cat Part No DX3MCBs 408634 of its equvalent in L&T/Siemens / Standard
Supply and fix in replacement MCB, SP, 6 to 32 Amps 10 KA breaking / rupturing capacity capacity including necessary connection with suitable size of copper cable complete all as directed. MAKE: Legrand Cat Part No DX3MCBs 408636 of its equvalent in L&T/Siemens / Standard
Supply and fix in for replacement rewirable switch fuse unit,of sheet metal , triple pole and neutral, 415 Volts grade, 32 Amps capcity including neccssary connection with suitable size of copper cable complete all as directed. MAKE: CAT No#DTPN032 OF Indoasian .or its Equvalent.in L&T/Legrands/Siemens / Standard
All as Per item No 32 above but 63 Amps capcity . MAKE: CAT No #DTPN063 OF Indoasian or its Equvalent.in L&T/Legrands/Siemens / Standard
All as Per item No 32 above but 100 Amps capacity. MAKE: CAT No #DTPN100 OF Indoasian or its Equvalent.in L&T/Legrands/Siemens / Standard
Supply and fix in existing panel board for replacement of Switch Disconnector fuse (Cubical with HRC Fuse) Tripple pole and neutral 100 Amps ,415Volt,50HZ,AC 23A, conforms to IS:13947-3, fixed in existing Panel and connecting all as directed. MAKE: CAT No SK95571 of L&T its Equvalent.in L&T/Legrands/Siemens / Standard
Supply and fix in in existing panel board for replacement of Switch Disconnector fuse (Cubical with HRC Fuse) Tripple pole and neutral 200 Amps ,415Volt,50HZ,AC 23A, conforming to IS:13947-3, fixed in existing Panel and connecting all as directed. MAKE: CAT No SK95607 of L&T its Equvalent.in L&T/Legrands/Siemens / Standard
Supply and fixing in existing panel board for replacement MCCB, 4 Pole, 400 Amps , with breaking capacity 36 KA , fixed type(HBC Series),adjustable type thermal setting 70-100% and magnetic adjustable 5-10 times AC 415 volt ,50 HZ conforming to IEC:60947-II/IS:13947-II and connecting all as directed. MAKE: CAT No Legrand Cat Part No DPX3 630, 422007 ofr its equvalent in L&T/Siemens / Standard
All as per item No 47 here in above but 200 Amps 25 KA breaking capacity. MAKE: CAT No Legrand Cat Part No DPX3 250, 420218 of its equvalent in L&T/Siemens. / Standard
All as per item No 47 here in before but 100 Amps 25 KA breaking capacity. MAKE: CAT No Legrand Cat Part No DPX3 250, 420215 of its equvalent in L&T/Siemens / Standard
All as per item No 47 here in before but 63 Amps 25 KA breaking capacity. MAKE: CAT No Legrand Cat Part No DPX3 160, 420053 of its equvalent in L&T/Siemens / Standard
Supply and fix in repairs/replacement of GI continous earth wire 4mm dia on cross arms of poles for guarding including binding and dismentling of old broken guarding complete all as specified and directed / Standard
Supply and fix in repairs change over switch existing panel, wall or LT pole of any size and any type on load type, triple pole and neutral, 63 Amps, 415 V, 50 Hz front handle operated, including connecting and testing all as directed. MAKE: CAT No CO10630OOOD of L&T or its equivalent in Legrands/Seimens / Standard
All as per Item No 42 above but off load type and side handle operated,Conforms IS/IEC 60947 including connecting and testing all as directed. MAKE: CAT No OFFPOO63 of Indoasian OR ITS EQUIVALENT IN HAVELLS / Standard
All per item No 42 above but , off load type, 100 Amps, front handle operated, MAKE: CAT No OFFPO100 Of Indoasian OR ITS EQUIVALENT IN HAVELLS / Standard
All as per item No 42 above but off load type, 125A side handle operated, MAKE: CAT No OFFPO125 of Indoasian OR ITS EQUIVALENT IN HAVELLS / Standard
Supply and fix in replacement of surface mounted SMC street light control box of external dimensions 250 X 175 X 100 mm, fixed on pole with FI clamps of size 25 X 3 mm all as directed. MAKE : SINTEX/National
M & L for replacement of existing Amp meter (0-300Amp) along with CTs from existing LT Panel of any size
M & L for replacement of existing Volt meter 0 to 600 volt , digital type from existing LT Panel of any size, Make" L&T, CG, AE
Material and labour for spray painting the LT Steel tubular pole,9 mtr long with two coats of synthetic enamel paint including prepartion of surfaces,Scraping the old paint and writing pole No in Black letter under yellow circle all as directed.
Material and labour for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick, buried vertically in ground (Each pit not less than 2.25 mtrs deep below normal ground level with top edge of plate not less than 1.50 M below normal ground level) connected to GI strip 32 x 6 mm , by means of bolts, nuts, and check nuts and washers etc encased in GI protection pipe 40 mm dia light grade pipe for protection of GI earth strip both to be provided to the extet of 7.5 meters, all as shown on electrical plate No 3 of MES SSR - 2004 Part - I, GI protection pipe buried in ground, laid under floors / plinths or mixed on walls / pole etc or concealed in walls etc; with provision of mixture of charcoal dust and common salt packed upto minimum 150 mm all around the earth plate, including PCC 1:2:4 type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with GI 20 mm dia medium grade pipe and MS funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of soil / strata and testing on completion complete all as specified and directed. Note:- i) Cost of GI strip 32 x 6 mm and protection pipe 40 mm dia is deemmed to be included in rate quoted ii) Excavation and returning filling of Soil any type is deemed to be included in rates.
S&F in replacement of drop out fuse unit, explusion type for out door air break gang oprated switch, single pole mounted on and including insulators for 11 KV working pressure fixed to and including MS channel with nuts, bolts and washer etc synthetic bounded fuse tube complete with line capcity suitable for current carrying capacity upto 100 Amps all as directed including taking down old one all as specified and as directed
Repair / Overhauling of air break switch by replacing stationary and moving contacts, flexible copper chord, GI nuts, bolts etc including alingment for smooth functioning from ground level all as required at site and all as specified & directed.
Supply & fix LT line seperator 3/4 lines made of high quantity PVC material to provide 300 mm distance between phase to phase and neutal or as per sit reuirement as directed by Engineer-in-Charge Make: Supreme & Co Pvt Ltd Sanjay casting and Engineers, Mahalaxmi cable & Conductor.
Material and labour for brick protection with sub class B bricks using old size bricks, laid dry, flat over cable, longer length of brick laid perpendicular to the cable in trenches all as directed
An amount of Rs 55,188.00 shall be deducted rom BOQ on account of schedule of credit
Maruti Abhiyantriki
R. T. Saluji
OM SAI ASSOCIATES
KAMINS CARE
Divate Babasaheb Ramchandra
T.H.ASSOCIATES
Mahindra Electric Stores
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .