Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.6 LAccepted-AOC 37 222 BUNDU KATRA AGRA UP | AGRA | UP | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹14.2 L+₹2.0 L (16.3%)Rejected-AOC H NO 279 SHAHEED NAGAR AGRA | AGRA | L2 | Rejected-AOC Not lowest | |
| 3 | L3₹14.5 L+₹2.3 L (18.6%)Rejected-AOC | L3 | Rejected-AOC Not lowest |
Tender Value
₹13.5 L
EMD Value
₹27,000
Closing Date
23 Jul 2020, 6:00 pmClosed
GE Bharatpur
GE Bharatpur
REPAIR/MAINTENANCE OF DG SET, PUMP SETS, CLEANING OF O/H TANKS, U/G TANKS, OPEN WELL AND AT GUNDRAI PUMP HOUSE, NEW AND OLD CAMPUS AREA, KESHARBAGH OF RMS DHOLPUR UNDER GE BHARATPUR
2020_MES_337649_3
8931/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
RMS Dholpur
Class E category a(I) b(I)
7 documents required · 7 mandatory
₹500
Yes
GE Bharatpur
₹27,000
Yes
31 Jul 2020
29 Jun 2020
25 Jul 2020
29 Jun 2020
23 Jul 2020
11 Jul 2020
Amount
Taking out submersible pump set of capacity 40HP 3 Phase 415 volt AC supply alongwith column pipes from the bore well by disconnecting electric connection, disconnecting the motor from pump dismantling the motor & over hauling the same by repairing/ replacing defective part as ordered & re-assembling including M&L for replacing worn- out nuts bolts washers complete, connecting /coupling the motor with pump & with column pipes & lowering the same after repairing, making the connecion complete all as directed by Engr-in-Charge. Note: Spares shall be measured & paid separately for dismantling of pump set partly or full shall be paid accordingly.
Supply only spare parts for above 40HP submersible pump at item No 01: (a) Hook bolt
Motor Bush
Rubber Bush
SS Bush
Stud with nuts & bolts
Neck Ring
Impeller
Top/Bottom bearing bush
SS Rooter sleeves
Thrust Plate
SS shaft
Bowl Bush
Diffuser CI/Steel
M&L for rewinding the submersible Motor 40HP with super enamaled copper winding wire of suitable gauge & superior class of insulation including insulation paper sleeves thimbles etc & testing.
Taking out submersible pump set of capacity 20HP 3 Phase 415 volt AC supply alongwith column pipes from the bore well by disconnecting electric connection, disconnecting the motor from pump dismantling the motor & over hauling the same by repairing/ replacing defective part as ordered & re-assebmling including M&L for replacing worn out nuts bolts washer complete connecting /coupling the motor with pump & with column pipes & lowering the same after repairing, making the connecion complete all as directed by Engr-in-Charge. Note: Spares shall be measured & paid separately for dismantling of pump set partly or full shall be paid accordingly.
Supply only spare parts for above 40HP submersible pump at item No 01: (a) Hook bolt
Motor Bush
Rubber Bush
SS Bush
Stud with nuts & bolts
Neck Ring
Impeller
Top/Bottom bearing bush
SS Rooter sleeves
Thrust Plate
SS shaft
Bowl Bush
Diffuser CI/Steel
M&L for rewinding the submersible Motor 20HP with super enamaled copper winding wire of suitable guage & class of insulation including insulation paper sleeves including dismantling & fixed in position after repair including cable connection with thimbles etc & complete testing
Cleaning of RCC overhead reservoir of 75,000 GLN capacity of 18 Mtr staging including draining out water. Removing, Mud, Slit/dust from Tank. Washing & rubbing with gunny bags & cleaning with fresh water & Bleaching powder including writing the date of cleaning etc by synthetic enamal paint all as directed by Engr-in-Charge. (a) All necessary ladder and scaffolding arrangement shall be made by the contractor. (b) All kind of safety equipments shall be arranged at site by the contractor. (c) In case of damage of any outlet pipeline/control valves during operation shall be borne by the contractor (d) Disturbed portion if any shall be made good as per existing by the contractor
Cleaning of Masonry /RCC under ground sump of 50 Kilo Gallon capacity, Located at Gundrai pump house No 1, including the following works: (i) draining out water with the help of monoblock pumpset (pumpset shall be managed by the contractor) (ii) Removing, Mud, Slit/dust from sump by manually & rubbing & cleaning with gunny bags etc (iii) washing with fresh water & Bleaching powder twon times (iv) writing the date of cleaning etc by synthetic enamel paint (v) applying two coat of light blue colour synthetic enamel wall paint internally upto 84SQM on inside of floor and all walls all as directed by Engr-in-Charge.
Cleaning of Masonry /RCC under ground sump of 25 Kilo Gallon capacity loacted at Cadets hostel area including the following works: (i) draining out water with the help of monoblock pumpset (pumpset shall be managed by the contractor) (ii) Removing, Mud, Slit/dust from sump by manually & rubbing & cleaning with gunny bags etc (iii) washing with fresh water & Bleaching powder twon times (iv) writing the date of cleaning etc by synthetic enamel paint (v) applying two coat of white wash.
Cleaning of Masonry /RCC under ground sump of 55 Kilo Gallon capacity loacted at Kesarbagh Sump House area including the following works: (i) draining out water with the help of monoblock pumpset (pumpset shall be managed by the contractor) (ii) Removing, Mud, Slit/dust from sump by manually & rubbing & cleaning with gunny bags etc (iii) washing with fresh water & Bleaching powder twon times (iv) writing the date of cleaning etc by synthetic enamel paint (v) applying two coat of white wash.
Cleaning of Shallow wells at Gundrai by cutting the MS sheet of 10mm thick by gas cutter in rectanglur shape approx 10 to 12 RM, welding the MS sheet of 10 mm thick by gas welding with the help of copper rod in rectangular shape approx 10 to 12 RM after completing cleaning work, Lowering the non clog pump set of 5 HP to 40HP capacity in shallow wells and running until well gets empty during the cleaning work is on including transportation expenditure, pipe arrangement etc., Making angle iron fabrication work at site over both shallow wells to rest/fixing chain pully set to draw bucket filled with mud, sludge, dust, fungus, useless stone pieces continuously till all the waste material removed from bottom of shallow well, Cleaning all pores/ Sources of water yield inside well's wall by brooming, brushing, rubbing, clothing until all rubbish material removed from well's wall and cleaning the wall with the help of water jet of sufficient pressure including cleaning of wall by disinfection chemical like bleaching powder properly or as directed by Engineer in Charge.
Dismantling electric motor of centrifugal pump 3 phase for 440 volt 30 HP and rewinding of motor with super enameled copper wire of same guage & turn including material, varnishing, re-assembling, testing & commissioning /complete all as directed by Engr-in-Charge
Dismantling of centrifugal booster pump 30 HP over hauling including machine work welding replacement of unserviceable parts , re-assembling, aligning & testing complete Note: Spares shall be measured & paid separately for dismantling of pump set partially or complete shall be paid accordingly.
Supply only spare parts for above Centrifugal Pump of 30 HP at item No 13 : (a) Ball bearing SKF/NBC (6309)
Pump shaft with Key
Coupling Key
Gland Plate (Set of two)
Suction/Discharge stud/Nuts/ Bolts
Gland Bush (Gun metal)
Coupling rubberised
Foot valve 80mm GI or CI heavy grade as per existing
M&L for rewinding the Submersible pump Motor 5HP with super enamaled copper winding wire of suitable guage & class of insulation including insulation paper sleeves thimbles etc & testing.
Supply & fixing MCCB 125Amp Four Pole (25KA) in existing panel board Make: Havells/CS/L&T/Legrand
Opening of DG set 82.5KVA water/air cooled (Kirloskar) by unscrewing nuts, bolts and servicing of DG set with checking, draining and changing of Engine oil and Coolant, checking and changing of V-belts, greasing and oiling of all relevant parts and topping up, Cleaning the inner body of Fuel tank and Radiator etc by removing sludge etc and reassembling the DG set after repair and replacement of unserviceable parts of DG set including repair of control panel, opening of alternator, water pump, starter motor for cleaning, servicing and refixing. Checking and servicing of Battery and testing complete in all respect all as directed by Engr-in-charge. Note: Spares shall be measured & paid separately for dismantling of DG set partly or full shall be paid accordingly.
Supply only following spare parts for item above DG Set item No. 17 :- (a) Air cleaner element
Water hoses including clamps complete all as specified.
Fuel filter element.
Lubrication oil filter
Fuel Pipe
Piston & Rings
Fan belt.
Head Gasket
RC Joint, Set of O Rings, Set of Joints
Valve Pair, Valve seal and Valve guide
Battery 150 AH (Type Flat Bed, Maintenance Free) Make :- Exide/ Amaron/ Luminous
Oil Pipes including clamps complete all as specified
Supply only coolant in one/two ltrs packing complete all as specified and directed by Engineer-in-Charge.
Supply only distilled water in one/two ltrs packing.
Supply & filling oil of recommended grade (DF-4, 15 W 40) Make Servo.(in 5 Litres Can) Required 20 Litres all as specified and directed by Engineer-in-Charge.
Supply and fixing of the following spare parts of FASD starters: (a) Contactor switch 25Amp capacity, with 380-415V coil, ML model of L&T or equivalent
Contactor switch 25Amp capacity, with 380-415V coil, ML model of L&T or equivalent
Contactor switch 40Amp capacity, with 380-415V coil, ML model of L&T or equivalent
Contactor switch 70Amp capacity, with 380-415V coil, ML model of L&T or equivalent
Start/Stop push button toggle switch
Starter relay 415V, 40Amp or above upto existing capcity range
Multi controller/single phase preventer & timer switch relay in single box capacity ranging from 7.5HP to 40HP make L&T, cat part No CS94824D000
GI Foot valve 40mm heavy type
Copper lugs of size 16 to 25sqmm
Aluminium lugs of size 50 to 120sqmm
M&L for rewinding of monoblock pumpset installed at Cadets hostel area after dismantling all connections and transporting to workshop and replaceing spares, cutting burnt out winding and rewinding suitable copper super enamelled conductors on primary stator and re-installing at existing loaction all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement of old unsv Direct Online Starter of capacity 7.5HP suitable for monoblock pumpsets installed at cadets hostel area complete all as specified and as directed by Engineer-in-Charge. Make L&T, cat part No SS96211
Replacement in Repair fully automatic star delta starter comprising of voltmeter 0-500 V and ammeter 0-100 Amps, single phase preventor, over load relay and timer housed in single MS sheet powder coated enclosure suitable for up to 40 HP (Rating / Capacity of starter should be 1.5 times more than that of Submersible Motor pump of capacity 40HP) submersible motor pump including first filling of oil in oil chamber (If Required) and testing complete (Make : L&T, Cat Part no CS90908)
Replacement in Repair fully automatic star delta starter comprising of voltmeter 0-500 V and ammeter 0-100 Amps, single phase preventor, over load relay and timer housed in single MS sheet powder coated enclosure suitable for up to 10 HP (Rating / Capacity of starter should be 1.5 times more than that of Submersible Motor pump) submersible motor pump including first filling of oil in oil chamber (If Required) and testing complete (Make :L&T, Cat Part No SS95983)
Labour only for servicing APFC panel board and cochecking all the contact terminals and capacitors, repairing the terminal wire circuits, tightening all kind of nuta sn bolts, screws atc, cleaning inside the chamber, enclosure etc, checking the connection of CT coil from panel to main incoming source and repairing in case of any fault in connections all as specified and as directed by Engineer-in-Charge. Note: Replacement of Spares shall be measured and paid separately.
Supply and replacement and testing at site of the following accessories of APFC panel: (a) Cylidrical series capacitors, KVAr rating 2, 440V, 3Ph, heavy duty, make L&T, Cta part No LTCOH or equivalent
Cylindrical series capacitors, KVAr rating 5, 440V, 3Ph, heavy duty, make L&T, Cta part No LTCOH or equivalent
Cylidrical series capacitors, KVAr rating 10, 440V, 3Ph, heavy duty, make L&T, Cta part No LTCOH or equivalent
VAF + PF meter accuracy class 1.0. 0.5, input voltage measurement range 50 - 520 VAC (P-P), Aux supply 80-300 VAC/DC, CT secondary side 1A/5A, Flush mounting 96x96, CT/PT programmable, Para meters VLL, VLN, A, F, PF, On Hrs, RPM, Apeak etc with RS485, Cl-1, Make L&T, Cat Part No WL4110110000
Replacement of DI (Ductile Iron) flanged end on both sides of 150 mm dia , K-9 complete with rubber gasket nuts, bolts and washers (Make : Jindal/ Electrosteel/ Tata).
S&F DI fittings such as tail piece, Socket and flange end, DI reducer socket 150 x 100 or any other size, Equal tee of any size and type, reducer Tee of any size and type etc all as specified and as directed by Engineer-in-Charge
Painting of motor and pumpset centrifugal type 30HP after preparation and one x sigle coat primer and applying spray painting of two coat synthetical enamel paint of approved colour etc without disturbing anyother parts of the complete set all as specified and as directed by Engineer-in-Charge.
Painting of monoblock pumpset type 5HP after preparation and one x sigle coat primer and applying spray painting of two coat synthetical enamel paint of approved colour etc without disturbing anyother parts of the complete set all as specified and as directed by Engineer-in-Charge.
Painting of mounting channels of pumpset of any size, type and length after preparation and one x sigle coat primer and applying spray painting of two coat of black colour synthetical enamel paint etc without disturbing anyother parts of the complete set all as specified and as directed by Engineer-in-Charge.
Painting of MS sheet cover fabricated on open well No 1, 2 and 3 at Gundrai after preparation and one x sigle coat primer and applying spray painting of two coat of black colour synthetical enamel paint etc without disturbing anyother parts of the complete set all as specified and as directed by Engineer-in-Charge.
M&L for providing angle iron support under the NRV at Well No 2 including, cutting, bending, fabrication, welding, and one coat anti corrosive primer and one coat synthetic enamel paint all as specified and as directed by Engineer-in-Charge.
M&L for painting of sluice valve/NRV/Air Release valve etc after preparation of surface with sand paper and one x coat of anticorrosive primer and one x synthetic enamel paint of black colour complete without damaging other parts all as specified and as directed by Engineer-in-Charge.
M&L for painting of GI/CI pipeline of any size and type at Kesarbagh sump house, pump house No 1, 2 and 3 at Gundrai, bore well pump house at India lake, delivery pipe of UG sump monoblock pumpsets located in 6 x hostels etc after preparation of surface with sand paper and one x coat of anticorrosive primer and one x synthetic enamel paint of black colour complete without damaging other parts all as specified and as directed by Engineer-in-Charge.
M&L for replacing gland packing by dismantling Gland plate and stud, cleaning inside the packing house etc for suitable size of 150mm sluice valve, leakage testing and obtaining OK result from Engineer-in-Charge all as specified and as directed.
M&L for greasing on motor and pumpset nipples , replacing burnt gland packing of any size and of centrifugal/monoblock pumspset of any size and capacity including leakage and damiging testing and obtaining OK result all as specified and as directed by Engineer-in-Charge.
M&L for sevicing, cleaning and testing of chlorination plant , removing blocked delivery hose, servicing, oiling/greasing/rewinding of 2 x 0.5HP motors all as specified ans directed by Engineer-in-Charge
Nuprine rubber / Leather gasket minimum thickness 8mm suitable for tightening the GI flange or any othe joints of 100mm dia with nuts and bolts,
Demolition of old PCC foundation any type and size including removal of anchor bolt and removing debris from site at safe place as eco friendly manner all as specified and as directed by Engineer-in-Charge
M&L for PCC work for pumpset platform and other misc pedestal supports, type C1, mixing ratio 1:3:6 using 20mm gradded aggregate complete including form work etc all as specified and directed by Engineer in Charge
S&F display board of Pumpsets, DG sets, Motors, Open well, Bore well, starter panels, monoblock pumpsets, chlorination plants etc of size 60cm x 30cm x 20mm thick made of two laye acrylic sheet including relevent letter of size 7cm height and 1.5cm thick of white colour on blue layer sandwitched between two acrylic layers, including fixing, revetin or screwing on the wall all as specified and as directed by Engineer in Charge.
Calcium based high strength granular Chlorination chemical water disinfectant, a white free flowing granular material which is free of Foreign materials, concentration of Chlorine content should be between 60 to 70 percentage stability, Make-Declibac or equivalent
Taking out Serviciable/unserviciable GI/CPVC column pipe 40/50 mm dia x 3 mtr long both end flanged or threaded any type and stored at one place and re-installig after repairing or devolpment of bore well all as directed by Engr-in-Charge.
Development of tube well with compressed air and after with 25% extra capacity pump by pumping muddy water with the help of suitable pneumatic boring compressor at Gundrai and Kesarbagh whereever directed.
Supply,connect,fix and test submersible cables copper conductor PVC insulated over all sheathed flat flexible, ISI marked - Conforming to IS 694,1100 volts grade complete of sizes (a) 10 sqmm 3 core
All as per Srl item No 48 here in before but 16 sqmm 3 core
M & L for dismantling existing broken valve pit complete with corroded MS sheet cover including removal of all material and construction of valve pit chamber, brick masonry all as specified in drg No TD/2004/26 sheet 1/3 to 3/3 for sluice valve including plastering, PCC in foundation excavation and earth work, MS sheet cover (3mm thick) with locking arrangement, painted with two coats of anticorrosive paint over one coat of primer of following sizes:- (a) 1000mmx 950mm x 1000mm
All as per Srl item No 49 here in before but 16 sqmm 3 core
Labour only to attend break down of motor pumpsets & CI/GI pumping and distribution line any size and type including excavation , taking out of pipes, valves, replacement of damaged portion, repair of pipeline leakages, including welding if required, replacement of joints/gasket/packings and all kind of water supply related complaints on daily basis as per the directions from the beginning and upto the completion of contract complete all as specified and as directed by Engr-in- charge. Note: (i) Each Breakdown in pumping line of size 50mm dia to 150mm shall be counted as one job (ii) Breakdown of any three in distribution line below the size of 50mm shall be counted as one job. (iii) 01 x Pipe fitter skilled and 02 x helpers able to excavation and removal of pipeline shall be provided by the contractor on daily basis till the completion of contract. (iv) Welding , jointing and refixing/addn/altn of size and length shall be included in rate. (v) No vehicle shall be provided by the MES for conveyance of the pipe ftr and helpers. (vi) Items replaced in each breakdown shall be measured and paid separately.
abhinav and company
M/S MAKHIJA TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .