Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.8 LAccepted-AOC NEAR SATSANG GARACHARMA BASTI GARACHARMA PORT BLAIR 744 105 | PORT BLAIR | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744105 | L1 | Accepted-AOC L1 | |
| 2 | L2₹49.3 L+₹2.4 L (5.01%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹51.8 L+₹4.9 L (10.4%)Rejected-Finance | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹52.6 L+₹5.6 L (12.0%)Rejected-Finance | L4 | Rejected-Finance Not Being L1 | |
| 5 | Rejected-Technical 956 2 CHANDERSEKER ENTERPRISE OPP MARICAR HOSPITAL OLD CCS JUNGLIGHAT SOUTH ANDAMAN ANDAMAN NICOBAR 744103 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | - | Rejected-Technical Residual work load not submitted |
Tender Value
₹43.5 L
EMD Value
₹87,000
Closing Date
14 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Minniebay
GE Minniebay Junglighat Post Minniebay Port Blair 744103
ADDN ALTN OF COMMAND SWIMMING POOL AT MINNIEBAY UNDER GE MINNIEBAY PORT BLAIR
2023_MES_615082_1
8291/E8
Open Tender
Civil Works
Item Rate
180 days
Minniebay Port Blair
AS PER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
Yes
GE Minniebay
₹87,000
Yes
18 Oct 2023
22 Aug 2023
16 Sept 2023
23 Aug 2023
14 Sept 2023
8 Sept 2023
Amount
Demoliton of Plain cement concrete and mortar of any description and in any position not otherwise specifically provided for,complete all as specified and directed by Engineer-in-Charge.
Demoliton of Reinforced cement concrete and mortar of any description and in any position not otherwise specifically provided for, complete all as specified and directed by Engineer-in-Charge. Note : The cost for removing old rusted steel bars shall be deemed to be included in this quoted rate.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
Material and labour for 40mm thick, Plain Cement Concrete 1:2:4, Type B-0, using 12.5mm graded aggregate as in sub base for flooring/levelling coarse etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for Vitrified Chequered cement concrete tiles 30cm x 30cm x 10mm thick, set, jointed and pointed in near cement slurry in floors/skirtings with grey cement and pigments and including 15mm thick in CM 1:4 screed bed complete all as specified and directed by Engineer-in-Charge.
Demolition of precast concrete block walling built in cement mortar including all quoins arches pillars etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for Precast cement concrete block masonry with solid block, exc 10cm in width in PCC type C-1, 1:3:6 (using 20mm graded stone aggregate) set in CM (1:6) complete all as specified and directed by Engineer-in-Charge.
Taking down Cement Plaster of any description on brick or stone walls or concrete surfaces, ceiling including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge.
M & L for 10mm rendering in cement mortar 1:6 to concrete or block masonry surfaces or surfaces other than fair faces of brick surfaces, finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Material and labour for rendering 5 mm thick in cement mortar 1:4 over a backing coat of 10mm thick in CM 1:6 (Total 15 mm thick) on concrete or brick masonry surfaces including mixing water proofing compound as per manufacurers instruction in top layer and finishing the surface even and fair complete all as specified and directed by Engineer-in-Charge. Note: Water proofing compound will be measured and paid separately under repective item.
M&L for providing and laying 20 mm thick POLYMER MODIFIED MORTAR over identified R.C.C. members in layers of requisite proportion by weight of polymer of approved make, cement and filler material of approved make, blended to a required consistency and applying and finishing even and smooth, curing, complete as manufacturer instruction including providing necessary formwork, mild steel shear key wherever required, bonding slurry, etc complete all as specified and as directed by Engineer-in-Charge.
Supply only Integral water proofing compound.
M&L for cutting out existing cracks in concrete surfaces/ masonry wall/ RCC slab, forming a 'V' Groove of 25mm x 40mm size, cleaning the groove thoroughly with air blower, priming the groove with mixture of polymer of approved make as specified using spray gun/ brush, filling the groove with putty of Crack filler mixed in proportion as per manufacturer instructions and finally applying a seal coat of approved make as specified of same as of primer coat with brush complete all as per manufacturer's instructions complete all as specified and as directed by Engr-in-Charge.
M & L for non shrink, cementitious Micro concrete mixed with 12.5mm graded crushed stone aggregate in the ratio by weight 18kg aggregate: 25kg micro concrete respectively or as per manufacturer's instructions, as in sides and soffits of beams, jacketing of columns, roof slab and similar structural members including necessary form work for fair finished surfaces. The formwork shall be water tight to facilitate pouring of micro concrete complete all as per manufacturer's instructions complete all as specified and as directed by Engr-in-Charge. NOTE FOR ITEM NO.10 to 14 : (i) The successful contractor shall execute the structural repair and rehabilitation work through the Manufacturer's authorised applicator only and the copy of the agreement/certification for the same shall be submitted to the Accepting officer for approval before the execution of the work. During Pre & post execution, a structural test report shall be submitted by the contractor against the actual /enhanced strength of the concerned building where works to be carried out from IIT/NIT/NABL approved lab. An amount of 5 % of the quoted amount subject to a minimum Rs.50,000/- shall be retained against security deposit against the structural repair work under the respective items and gurantee bond for the same shall be also submitted in Non Judicial stamp paper duly notarized along with the deposit amount. The contractor shall quoted accordingly and no claim shall be entertained later.
Material and labour for complete removal using mechancial sander and applying one coat of white cementitious putty on wall and making the surfaces smooth by rubbing with appropriate sand paper to achieve smooth finished surface complete all as specified and as directed by Engineer-in-Charge.
Material and labour for preparing newly plastered surfaces of wall and applying two coats of oil emulsion distemper over a coat of primer using Airless spray technology with max working pressure of 22.8 Mpa/3300 psi and capable of operating single spray gun with a max material hose length of 30m complete all as specified and as directed by Engineer-in-Charge.
M&L for applying one or two coats of damp proof primer (primer coat) using Airless spray technology with max working pressure of 22.8 Mpa/3300 psi and capable of operating single spray gun with a max material hose length of 30m and Applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm Anti algal weather coat 100% acrylic smooth emulsion paint using Airless spray technology with max working pressure of 22.8 Mpa/3300 psi and capable of operating single spray gun with a max material hose length of 30m on newly plastered surfaces Note for item No.15 to 17 : (1) Work shall be executed only through authorised applicator duly approved by Manufacturer of Paint and certificate in this connection shall be submitted by the Contractor. (ii) The affected area of the wall due to dampness shall be ascertained by moisture meter of power input 9v Display 60 LEDs using colour code scale and Moisture measurement of each location shall be submitted along with RAR. (iii) The contractor shall upload MOU letter with any one of Paint manufacturer within 28 days of receipt of acceptance copy failing which contract shall be liable for cancellation. Authorised applicator shall have valid authorisation letter from the manufacturer The authorisation letter needs to be valid for the complete period of execution of the painting work. (iv) After preparation of the surface, Engr-in-Charge shall inspect and approve the same before applying primer and finishing coats. (v) Building wise stage passing register shall be maintained & submitted alongwith RAR/FB duly signed by Engr-in-Charge and contractor. (vi) The equipments to be used in the work shall be certified by the manufacturer with whom the MOU been entered into. The specification and details of the equipments and tools pertaining to this item is denoted on Particular Specification.Manual method of paint application is not allowed and also Penalty shall be levied if appropriate tools & equipments pertaining to smart periodicals not used. (viii) Proper masking arrangement shall be carried before the application of primer or paint. (ix) The other coat of Primer and Paint shall be applied only after the completion of drying time and comply with recoating period as per manufacturer instructions. (x) Cost of scaffolding shall be included in the quoted rate.
Supply and fix in repair swimming pool spring (Diving) board Anti slippery blue colour made up of polyester fiber glass and teakwood heavy duty with fiber coating of thickness 40 to 60 mm, upto length 3.5 metre and width 500 mm constructed with stainless steel fulcrum stand including necessary fixing arrangement as per manufacturer's instruction complete all as specified and as directed by Engineer-In-Charge.
Supply and fix glass mosaic tiles of size 247mm x 122mm x 8mm thick on wall and floors as in fountain, swimming pools or any water retaining structures using approved adhesive/chemical or sealed mix mortar of 15mm backing coat etc complete all as specified and as directed by Engineer-In-Charge.
S&F glass mosaic pool fittings external angle of size 250 mm x 50 mm thick on walls as infountain, swimming pool or any water retaining structures complete over and including approved chemical / sealed mix mortar including 15mm thicj backing coat etc complete all as specified and as directed by Engineer-in-Charge
S&F glass mosaic pool fittings internal cove of size 244 mm x 40 mm thick on walls as in fountain, swimming pool any water retaining structures complete over and including approved chemical / sealed mix mortar including 15mm thicj backing coat etc complete all as specified and as directed by Engineer-in-Charge
S&F glass mosaic pool fittings angle of wall floor, junction of size 40 mm x 40 mm thick on walls as in fountain, swimming pool any water retaining structures complete over and including approved chemical / sealed mix mortar including 15mm thicj backing coat etc complete all as specified and as directed by Engineer-in-Charge
S&F glass mosaic pool fittings junction of three external angle of size 40mm x 40m thick on walls as in fountain, swimming pool any water retaining structures complete over and including approved chemical / sealed mix mortar including 15mm thicj backing coat etc complete all as specified and as directed by Engineer-in-Charge
S&F glass mosaic pool fittings external angle of wall floor junction size 72 mm x 72 mm thick on walls as in fountain, swimming pool any water retaining structures complete over and including approved chemical / sealed mix mortar including 15mm thicj backing coat etc complete all as specified and as directed by Engineer-in-Charge
Supply and fix of PVC interlocking tiles of thickness 5-6 mm anti skid for resistance made from high quality 100% virgin PVC material with fabric backing or insert, plain coloured laid in floors or in wall cladding by using approved adhesives/chemicals as per manufacturer instructions complete all as specified and as directed by Engineer-in-Charge. Note for item No 19 to 25 : (i) These specialized work shall be executed adhering the installation procedures as specified by manufacturer employing skilled labourers. (ii) if any defect/ issues regarding poor workmanship shall be rectified by the contractor on free of cost.(iii) An amount of 5 % on total executed amount of specified items shall be retained against the performance of water tightness subject to a minimum of Rs 25000/- and gurantee bond on Non judicial stamp paper shall need to be submitted duly notarized for 2 years from date of completion.
Material & Labour for providing and fixing stainless steel (Grade SS-316) ISI marked railing dul polished with buffing machine made of hollow tubes, channels, plates etc., including welding, grinding , buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts complete all as specified and directed by Engineer-in-Charge.
Material and labour for cutting holes in brick/block masonry walls in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or Plain cement concrete (Nominal mix) 1:2:4 Type B-1 as required exc one brick but n exc 2 brick width complete all as specified and as directed by Engr-in-Charge.
M&L for CRS grade TMT bars 10mm dia and over cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking end and binding with and including mild steel wire not less than 0.9mm dia or securing with clip quality confirming to deformed or twisted bars complete all as specified and as directed by Engr-in-Charge.
Material & Labour for removing and cleaning of the concrete surfaces by wire brushes and applying anticorrosive epoxy coating as per manufacture's instructions on prepared surface to receive guniting, supply and tying welded IRC stainless steel wire fabric 100mm x 100 mm x 10 gauge, binding with GI wire 22 gauge to reinforcement , applying cementitious slurry (mixture of cement, sand, water and polymer based additive) uniformly to exposed surfaces and guniting using CM 1:3 average thickness of guniting not less than 40mm and at a pressure not less than 6Kg/Sqm and finishing the surfaces with 10mm thick rendering in CM 1:4, trowled even & smooth finish, without using extra cement, including necessary scaffolding and necessary safety arrangements and removing debris out side MD land complete all as specified and as directed by Engr-in-Charge.
M&L for Reinforced cement concrete (Design mix) M-30 graded using 20mm size coarse aggregate in chajjas etc including formwork complete all as specified and as directed by Engineer-in-Charge.
M&L for Reinforced cement concrete (Design mix) M-30 graded using 20mm size coarse aggregate in spiral staircases (including landings) etc including formwork complete all as specified and as directed by Engineer-in-Charge.
M&L for Reinforced cement concrete (Design mix) M-30 graded using 20mm size coarse aggregate in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like including formwork complete all as specified and as directed by Engineer-in-Charge.
M&L for Reinforced cement concrete (Design mix) M-30 graded using 20mm size coarse aggregate in columns, pillars, piers, post and struts etc including formwork complete all as specified and as directed by Engineer-in-Charge.
M & L for taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fittings such as conduits, switches, ceiling roses, pendants, regulators sockets etc, removing materials and making good of disturbed surfaces of walls, floors, etc complete all as specified and directed by Engineer-in-Charge.
M & L point wiring with 2 runs of 1.5 Sq.mm (nominal area) PVC unsheathed multi strandard FRLSH copper conductor pvc insulated 1100 volt single core cable drawn through concealed/surface mounted and including rigid steel conduit medium grade ISI marked minimum 25mm dia and its accessories complete along with 1.5 Sqmm PVC unsheathed multi strandard FRLSH copper conductor pvc insulated 1100 volt single core cable but in green colour as continuous earthing wire and connecting to common earth dolly completely concealed ,ceiling/roofs with and including 1.2 mm thick MS sheet terminal boxes duly fabricated flush mounting in the wall for mounting switches,switch socket combinations fan regulators etc., as required with 3 mm CRCA sheet Metal enclosure box as per required size complete all as specified and directed by Engineer-in-Charge.
One light /fan point controlled by one way 5/6 amps switch complete all as specified and directed by Engineer-in-Charge.
All as per item No.30 here in before but with 2 runs of 2.5 Sqmm single core multi standard unsheathed FRLSH copper conductor for one three pin socket 15/16 Amps on independent board including continuous earth wire 2.5 Sqmm PVC unsheathed multi strandard FRLSH copper conductor pvc insulated 1100 volt single core cable to common earth dolly complete all as specified and directed by Engineer-in-Charge.
M&L for Sub main wiring complete with 2 runs of 6 sqmm, single core, multi stranded copper conductor FRLSH PVC insulated and sheathed cable 1100 volts grade, drawn in 25mm enamelled steel conduit on surface/concealed (as required) along walls roofs etc including 6 sqmmm size 6.0Sqmm PVC unsheathed multi strandard FRLSH copper conductor pvc insulated 1100 volt single core cable to common earth and connecting to earth dolly complete all as specified and directed by Engineer-in-Charge. Note (i) All three wire/cable (phase, neutral and earth) should be run through for each individual circuit from the DBs. (ii) Two run/four runs of cable and one run/two runs of earth conductor and PVC Conduit/Casing Caping be measured as one length.
S&F flameproof LED tube light 2x16W flame proof type FLP-WP, CMRI certified recommended for gas/vapour group of IIA & IIB, Zone 1 & 2 and IP 65 protection with die cast alluminum hosing with heat resistant toughened glass with LED tupe light fixture driver, holders, connectors etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable drawn through steel enamelled flexible conduit with suitable size complete all as specified and directed by Engineer-in-Charge.
Supply & Fix flame proof Exhaust fan , 380 mm Sweep 240 volt,1440 RPM,Opal. White/brown.CMRI certified recommended for gas/vapour group of IIA & IIB, Zone 1 & 2 and IP 65 protection with die cast alluminum hosing including making hole suitable size for fixing 380 mm sweep exhaust fan making good distribution and after fixing exhaust fan flap cover tobe fixing on behind exhut fan hole , louvers, wiremesh, nut bolts, metalic conduit, capacitors including all acessories complete all as specified and directed by Engineer-in-Charge.
Supply & Fix flame proof ceiling fan , 1200 mm Sweep 240 volt, Single Phase. CMRI certified recommended for gas/vapour group of IIA & IIB, Zone 1 & 2 and IP 65 protection with die cast alluminum hosing, jerk free oscillation & smooth running comprising of high performance high speed motor for higher air delivery incl connecting up to the ceiling rose(flame pfoof) including all accessories, metallic conduit complete all as specified and directed by Engineer-in-Charge.
Supply & Fix flame proof regulator 240 volt. CMRI certified recommended for gas/vapour group of IIA & IIB, Zone 1 & 2 and IP 65 protection complete all as specified and directed by Engineer-in-Charge.
S & F switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed by Engineer-in-Charge.
S & F flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth complete all as specified and directed by Engineer-in-Charge.
S&F Flameproof junciton box 4 way complete all as specified and directed by Engineer-in-Charge.
S&F metal ceiling rose, surface Mild Steel/Cast Aluminium 65 mm x 30 mm, 3 terminals complete all as specified and directed by Engineer-in-Charge.
S&F Flame proof Distribution box SPN 8 Way with category of protection double door type IP-42 factory made with tinned copper 200 Amps rated bus bar suitable for MCBs and earth link connector, fixed in all as specified and directed. Note : SPN distribution board shall be fixed in the wall such that front cover shall be seen flush with the wall surface,complete all as specified and directed by Engineer-in-Charge.
Supply and fix flame proof MCB DP (Incomer) 63 Amps, 415 volts, 10 KA 'C' Curve CMRI certified recommended for gas/vapour group of IIA & IIB, Zone 1 & 2 and IP 65 protection with die cast alluminum hosing, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing 240V, 10 KA 'C' curve flame proof miniature circuit breaker (MCB) of double poles and current carrying capacity upto 25 A. CMRI certified recommended for gas/vapour group of IIA & IIB, Zone 1 & 2 and IP 65 protection with die cast alluminum hosing complete all as specified and directed by Engineer-in-Charge.
M&L for earthing complete with copper earth plate electrode 600 x 600 x 3 mm thick buried directly in ground (earth pit not less than 2.25m deep below GL) with top edge of earth plate not less than 1.5m below normal ground level, earth plate surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using copper earth strip 20x3 mm size connected by means of bolts, nuts, check nuts and washer of galvanized iron or steel, provision of 15 mm dia GI pipe medium grade for protection and 40mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6), type CI chamber. MS funnel, wire gauge. 50 mm thick RCC 1:2:4, type B1 earth pit cover with 6 Nos. 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 3 of schedule Part-I complete all as specified and as directed by Engineer-in-Charge. Note: (i) Cost of copper earth strip and GI protection pipe upto 7.5m length shall be deemed to be included in the rate quoted for this item. (ii) The unit rate shall also includes for Wire mesh, funnel, excavation, returning & filling, PCC chamber pit, RCC cover & test point.(iii) All accessories required for Copper plate electrode required, as specified and as directed.(iv) If the desired earth resistance is not achieved during testing as per IS , the complete earthing shall be replaced / repaired by the contractor at his own cost and no extra claim shall be admissible. (v) Earth test report shall be submitted to Accepting Officer for the payment of RAR / FB
Usha Builders
ANITA VARMA ENTERPRISES
BISAKHA PLUMBING WORKS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .