XEX Electrical division No. 1 shimla
Executive Engineer Electrical Division No-1 HPPWD Shimla-9
SH Providing wiring for additional Lights in ceiling cove light down lighter etc in various floor of blocks LT panel with phase corrector in lift machine room thereof
2019_PWD_31459_1
Electrical Div.No-1PWDShimla 19-20-2098-2103dt4
Open Tender
Electrical Works
Item Rate
180 days
SHIMLA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
E.E.Electrical Division No-I Shimla-9
₹19,600
8 May 2020
12 Sept 2019
10 Oct 2019
12 Sept 2019
9 Oct 2019
12 Sept 2019
Amount
Supply installtion testing & commissioning of -LT control Panelwith PHASE CORRECTOR MB panel board fabricated from 2 mm thick CRCA steel sheet seven tank process powder coated floor mounted sectionlised cubical type with 3 phase 100Amp cu bus bars i/c making the interior connections painting etc. comprising as per following specification. The panel shall be cubical typewall/ floor mounted & shall complete with ALL PETTY MATERIAL and followig accessories as incomer & out going
INCOMER;- 100 Amp MCCB four pole thermal megnetic with O/L & S/C protection, spreder link,and providing 1 no phase corrector i.e.complete with 50A TP contactor, coil voltage - 2 no,Add On block 1NO+1NC, Phase corrector relay,On Delay Timer,control SP MCB
Outgoing;- MCB 32 A TPN - 2N0
Providing and fixing 25mm x 5mm copper strip on surface or in recess for earth connections etc. as required.
Supplying & fixing LED STRIP warm white for cove light 5 watt non-integral, suitable for input voltage: AC 220-240 V, 50/60Hz per site of superior quality making connection testing with driver and other accessories as required. Make: LEDLEUM( NO-LSL-043) or any other equivalent make any other approved by Engineer-in-Charge.
Supplying and fixing of LED electronic driver; non-integral, suitable for input voltage: AC 220-240 V, 50/60Hz complete with all accessories, connections, testing and commissioning etc. as required. Make:- LEDLEUM,Pain Sonic, Syska any other Equivalent make approved by Engineer-in-Charge.
Providing and installation of following typeLED 12 watt ceillingmounted censor controlled light in white finish with anti glare polycarbonate diffuser and energy efficient constant current, non-integral, electronic driver; suitable for input voltage: AC 220-240 V, 50/60Hz, complete with all accessories, connections, testing and commissioning etc. as required. Make: Philips,Jaguar, Syska, GE, Bajaj, C&S, Panasonic or any other approved by Engineer-in-Charge.
Name of item:- Providing and installation of following typeLED 3 watt down lighter in white finish with anti glare polycarbonate diffuser and energy efficient constant current, non-integral, electronic driver; suitable for input voltage: AC 220-240 V, 50/60Hz, complete with all accessories, connections, testing and commissioning etc. as required. Make: Philips,Jaguar, Syska, GE, Bajaj, C&S, Panasonic or any other approved by Engineer-in-Charge.
Providing and installation of following type of recess mounting slim square type LED panel in white finish with anti glare polycarbonate diffuser and seprated energy efficient constant current, non-integral, electronic driver; suitable for input voltage: AC 220-240 V, 50/60Hz, complete with all accessories, connections, testing and commissioning etc. as required. Make: Philips, Syska, GE, Bajaj, C&S, Panasonic or any other approved by Engineer-in-Charge.
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required.Group C.
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No. HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required.
2x1.5 Sq. mm.
Providing and installation of stationary storage type Electric water heater ( Geyser) of various sizes by means of Expansion-Bolts with nuts and washers, including embedding of expansion-bolts in the wall, Providing and fixing of Non-return valve, Dead weight safety valve, 2 No. C.P connection rods 18" long, making good the damages, electrical connections, safety valve connections, testing and commissioning etc. as required:-
50 Liter capacity water heater (Cat-A).
D.S Ranta Electrical Contractor
Rakesh Kumar
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_45292.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .