Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.5 LAccepted-Finance 103 1A RAJA DINENDRA STREET KOLKATA 700 005 | KOLKATA | KOLKATA | WEST BENGAL | 700005 | L1 | Accepted-Finance Lowest bidder | |
| 2 | L2₹5.0 L+₹46,600 (10.4%)Rejected-Finance 103 1A RAJA DINENDRA STREET KOLKATA 700 006 | KOLKATA | KOLKATA | WEST BENGAL | 700006 | L2 | Rejected-Finance 2nd lowest bidder | |
| 3 | L3₹5.2 L+₹75,100 (16.7%)Rejected-Finance | L3 | Rejected-Finance 3rd lowest bidder |
| Sl No | Description | Qty | Unit | NATIONAL AIRCON L1 | UNIVERSAL SALES L3 | S.R. REFRIGERATION AND APPLIANCES L2 |
|---|---|---|---|---|---|---|
| 1.00Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). [CPWD(DSR) /32.2] (O-General/Mitsubishi Heavy Duty/Daikin/ Carrier/Voltas/Mitsubishi electric/Bluestar). | ||||||
| 1.01 | 2.0 TR with 5 Star BEE Rating (Inverter Type - Cooling only) | 7 | nos. | 60,000 ₹4,20,000 Lowest | 66,000 ₹4,62,000 | 64,000 ₹4,48,000 |
| 2.00Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :[CPWD(DSR) /31.14] | ||||||
| 2.01 | 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm | 49 | Mtr | 150 ₹7,350 Lowest | 380 ₹18,620 | 300 ₹14,700 |
| 2.02 | 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm | 49 | Mtr | 150 ₹7,350 Lowest | 420 ₹20,580 | 300 ₹14,700 |
| 3.00 | Supply & Laying of 4core 1.5sq.mm 1.1 KV insulation grade sheathed Cu cable with gas line as per direction of EIC for making interconnection/communication between Indoor to Outdoor unit of Split type AC m/c.(Make- Havells/Finolex/Polycab as approved by E.I.C) | 60 | Mtr | 150 ₹9,000 Lowest | 200 ₹12,000 | 180 ₹10,800 |
| 4.00 | Supply & Laying 20 mm hard PVC pipe (heavy type) for water drainage. | 70 | Mtr | 70 ₹4,900 Lowest | 150 ₹10,500 | 100 ₹7,000 |
Tender Value
Refer Docs
EMD Value
₹9,127
Closing Date
6 Nov 2026, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AE/KLESD/PWDte
Office of the Assistant Engineer, P.W.D. Kolkata Lok BhavanElectrical Sub-Division 2, Larkin Lane, Kolkata
Replacement of old window type air conditioning machines into split ac at ADC(IPS) residence at Sri Aurobindo Kaksh of Lok Bhavan,Kolkata
2026_WBPWD_5081674_1
WBPWD/AE-KLESD/NIQ-47/2026-27
Open Tender
ELECTRICAL WORKS ORG
Item Rate
Lok Bhavan Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹9,127
27 Nov 2026
29 Oct 2026
9 Nov 2026
29 Oct 2026
6 Nov 2026
29 Oct 2026
120 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). [CPWD(DSR) /32.2] (O-General/Mitsubishi Heavy Duty/Daikin/ Carrier/Voltas/Mitsubishi electric/Bluestar). | |||||
| 1.01 | 2.0 TR with 5 Star BEE Rating (Inverter Type - Cooling only) | 7 | nos. | - | - |
| 2Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :[CPWD(DSR) /31.14] | |||||
| 2.01 | 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm | 49 | Mtr | - | - |
| 2.02 | 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm | 49 | Mtr | - | - |
| 3 | Supply & Laying of 4core 1.5sq.mm 1.1 KV insulation grade sheathed Cu cable with gas line as per direction of EIC for making interconnection/communication between Indoor to Outdoor unit of Split type AC m/c.(Make- Havells/Finolex/Polycab as approved by E.I.C) | 60 | Mtr | - | - |
| 4 | Supply & Laying 20 mm hard PVC pipe (heavy type) for water drainage. | 70 | Mtr | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.13 MB
BOQ_5193071.xls
BOQ • 0.27 MB
2911.pdf
Tender Documents • 0.50 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .