GEMC-511687774403112
Awarded to RADHA ELECTRICALS
₹9.1 Cr
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| Supply of Prefabricated E-House Container | SCHNEIDER ABB / E-HOUSE CONTAINER | 9954 | 1 JOB | 9,000,000 | 9,000,000 |
| Installation of E-House Container | INSTALLATION | 9954 | 1 JOB | 584,100 | 584,100 |
| Supply of 6.6kV HT VCB GIS Switchgear Panel | SCHNIEDER ABB / 6.6 KV VCB | 9954 | 1 JOB | 14,100,000 | 14,100,000 |
| Installation Testing Commissioning of HT Switchgear Panel | INSTALLATION | 9954 | 1 JOB | 610,650 | 610,650 |
| Supply of 24V DC SMF VRLA Battery Bank | EXCIDE BATTERY / 24V DC SMF BATTERY BANK | 9954 | 1 SET | 324,500 | 324,500 |
| Installation Testing Commissioning of Battery Bank | INSTALLATION | 9954 | 1 JOB | 61,065 | 61,065 |
| Supply of Float and Float Cum Boost Charger | CHHABI / float cum boost charger | 9954 | 1 SET | 1,103,300 | 1,103,300 |
| Installation Testing Commissioning of Float Cum Boost Charger | INSTALLATION | 9954 | 1 JOB | 33,925 | 33,925 |
| Supply of Indoor LT Switchgear Panel | SCHNIEDER ABB / LT PANEL | 9954 | 1 SET | 16,500,000 | 16,500,000 |
| Installation Testing Commissioning of LT Switchgear Panel | INSTALLATION | 9954 | 1 JOB | 339,250 | 339,250 |
| Supply of 1000KVA Dry Type Transformer 2 Sets | VOLTAMP / 1000KVA Dry type trasformer | 9954 | 2 SETS | 4,543,000 | 9,086,000 |
| Installation Testing Commissioning of Dry Type Transformer | INSTALLATION | 9954 | 2 JOBS | 400,000 | 800,000 |
| Supply of Smart Local Monitoring HMI System | SCHNIEDER ABB / smart Local Monitoring HMI System | 9954 | 1 SET | 3,900,000 | 3,900,000 |
| Installation Testing Commissioning of Smart Monitoring System | INSTALLATION | 9954 | 1 JOB | 678,500 | 678,500 |
| Supply of APFC Panel 200 KVAr 2 Sets | SCHNIEDER ABB / APFC Panel 200 KVAr | 9954 | 2 SETS | 900,000 | 1,800,000 |
| Installation Testing Commissioning of APFC Panel | INSTALLATION | 9954 | 2 JOBS | 135,700 | 271,400 |
| Supply of Fire Alarm Detection System | SCHNIEDER ABB / fire alarm detector | 9954 | 1 SET | 767,000 | 767,000 |
| Installation Testing Commissioning of Fire Alarm System | INSTALLATION | HSN not specified by seller | 1 JOB | 339,250 | 339,250 |
| Supply of Fire Extinguishers | SCHNIEDER ABB / Fire Extinguisher | 9954 | 1 SET | 3,374 | 3,374 |
| Installation of Fire Extinguisher | INSTALLATION | 9954 | 1 JOB | 339 | 339 |
| Supply of Split Air Conditioners with Controller | voltas / split AC | 9954 | 1 SET | 507,388 | 507,388 |
| Installation Testing Commissioning of Air Conditioners | INSTALLATION | 9954 | 1 JOB | 81,420 | 81,420 |
| Supply of HT LT Touch Proof Termination Kits | Raychem / HT LT Termination Kit | 9954 | 1 SET | 713,900 | 713,900 |
| Installation Testing Commissioning of Termination Kits | INSTALLATION | 9954 | 1 JOB | 33,925 | 33,925 |
| Supply of UPS with Battery | APC / UPS WITH BATTERY | 9954 | 1 SET | 129,800 | 129,800 |
| Installation Testing Commissioning of UPS | INSTALLATION | 9954 | 1 JOB | 20,355 | 20,355 |
| Supply and Making of Chemical Earthing Pits | FASTRACK / Chemical Earthing pits | 9954 | 16 SET | 29,854 | 477,664 |
| GI Earthing Flat 50mm x 6mm for Substation Equipment | GI Patti / GI Earthing Patti | 9954 | 350 MTRS | 393 | 137,550 |
| Copper Earthing Flat 50mm x 6mm for Transformer Neutral | Copper Earthing / Copper Earthing Flat | 9954 | 100 MTRS | 5,204 | 520,400 |
| Supply of HT XLPE Cable 3Cx240sqmm to Tank Bunder SS | Polycab / HT XLPE 240 | 9954 | 300 MTRS | 3,185 | 955,500 |
| Supply of HT XLPE Cable 3Cx240sqmm to PV Dock SS | Polycab / HT XLPE 240 sq.mm | 9954 | 300 MTRS | 3,185 | 955,500 |
| Supply of HT XLPE Cable 3Cx240sqmm to Central SS | Polycab / HT XLPE 240 sq.mm cable | 9954 | 300 MTRS | 3,185 | 955,500 |
| Supply of HT XLPE Cable 3Cx240sqmm to RO-RO PAX SS | Polycab / HT XLPE 240 sq.mm cable | 9954 | 125 MTRS | 3,185 | 398,125 |
| Tracing and Cutting of Existing Buried HT Cable Feeder | Cable Tracing / testing & cutting | 9954 | 4 NOS | 58,410 | 233,640 |
| Supply of Straight Through HT Cable Joint Kit | Raychem / straight Through Joint Kit | 9954 | 4 NOS | 53,771 | 215,084 |
| Making of HT Cable Straight Through Joint | Raychem / straight Through Joint | 9954 | 4 NOS | 10,177 | 40,708 |
| High Potential Testing of HT Cable Joints | HT Agency / Cable Joints | 9954 | 4 JOBS | 7,463 | 29,852 |
| Phase Sequence Testing and Commissioning of HT Cable | Testing Agency / HT Cable | 9954 | 4 JOBS | 6,106 | 24,424 |
| Supply of Straight Through Transition HT Cable Joint Optional | Testing Agency / HT Cable Joint | 9954 | 2 NOS | 53,771 | 107,542 |
| Making of HT Cable Transition Joint PILC to XLPE Optional | Raychem / Joint PILC TO XLPE | 9954 | 2 NOS | 8,820 | 17,640 |
| Excavation of HT Cable Trench in Soft Soil or Asphalt | CIVIL JOB / Soft Soil or Asphalt | 9954 | 360 CUM | 2,478 | 892,080 |
| HT Cable Trench Excavation in Concrete Road Optional | CIVIL JOB / cable trench | 9954 | 102 CUM | 2,239 | 228,378 |
| Laying of HT XLPE Cable 3Cx240sqmm in Excavated Trench | INSTALLATION | 9954 | 925 MTRS | 1,363 | 1,260,775 |
| Laying of HT Cable in RCC Pipe or Existing Duct | INSTALLATION | 9954 | 270 MTRS | 649 | 175,230 |
| Supply of 200mm Dia RCC Pipe NP2 Class with Collars | RCC Pipe / 200 mm RCC Pipe | 9954 | 300 MTRS | 434 | 130,200 |
| Laying of RCC Pipe and Fixing of Collars | INSTALLATION | HSN not specified by seller | 300 MTRS | 271 | 81,300 |
| Supply of LT XLPE Cable 3.5Cx400sqmm to FP 6A | Polycab / LT XLPE CABLE | 9954 | 150 MTRS | 3,020 | 453,000 |
| Supply of LT XLPE Cable 3.5Cx400sqmm to FP 11 | Polycab / LT XLPE CABLE | HSN not specified by seller | 400 MTRS | 3,020 | 1,208,000 |
| Supply of LT XLPE Cable 3.5Cx300sqmm to FP 1A | Polycab / LT XLPE CABLE | 9954 | 125 MTRS | 2,400 | 300,000 |
| Supply of LT XLPE Cable 3.5Cx300sqmm to FP 3 | Polycab / LT XLPE CABLE | 9954 | 400 MTRS | 2,400 | 960,000 |
| Supply of LT XLPE Cable 3.5Cx300sqmm to FP 4 | Polycab / LT XLPE CABLE | 9954 | 325 MTRS | 2,400 | 780,000 |
| Supply of LT XLPE Cable 3.5Cx300sqmm to FP 5 | Polycab / LT XLPE CABLE | 9954 | 125 MTRS | 2,400 | 300,000 |
| Supply of LT XLPE Cable 3.5Cx300sqmm to FP 6B | Polycab / LT XLPE CABLE | 9954 | 125 MTRS | 2,400 | 300,000 |
| Supply of LT XLPE Cable 3.5Cx300sqmm to FP 6C | Polycab / LT XLPE CABLE | 9954 | 125 MTRS | 2,400 | 300,000 |
| LT Cable Trench Excavation in Asphalt Paver Area | CIVIL JOB / Asphalt Pavel area | 9954 | 504 CUM | 1,674 | 843,696 |
| Laying of LT Cable 3.5Cx300 or 400sqmm in Excavated Trench | INSTALLATION | 9954 | 1,575 MTRS | 1,560 | 2,457,000 |
| Laying LT Cable 3.5Cx300 or 400sqmm in Pipe or Duct | INSTALLATION | 9954 | 200 MTRS | 1,560 | 312,000 |
| Supply of LT XLPE Cable 3.5Cx70sqmm to Old CME Building | Polycab / LT XLPE CABLE | 9954 | 250 MTRS | 631 | 157,750 |
| Excavation of LT Cable Trench for 70sqmm Cable | CIVIL JOB / LT XLPE CABLE | 9954 | 108 CUM | 1,438 | 155,304 |
| Laying of LT Cable 3.5Cx70sqmm in Excavated Trench | INSTALLATION | 9954 | 160 MTRS | 1,153 | 184,480 |
| Laying of LT Cable 3.5Cx70sqmm in RCC Pipe or Duct | INSTALLATION | 9954 | 90 MTRS | 1,153 | 103,770 |
| Cable Termination Material for 3.5Cx70sqmm LT Cable | commet / INSTALLATION | 9954 | 2 NOS | 3,935 | 7,870 |
| Cable Termination Installation for 3.5Cx70sqmm LT Cable | cosmos / glanding & termination | 9954 | 2 NOS | 2,103 | 4,206 |
| Cable Termination Material for 3.5Cx300sqmm LT Cable | cosmos / glanding & termination | 9954 | 6 NOS | 5,292 | 31,752 |
| Cable Termination Installation for 3.5Cx300sqmm LT Cable | cosmos / glanding & termination | 9954 | 6 NOS | 2,510 | 15,060 |
| Cable Termination Material for 3.5Cx400sqmm LT Cable | cosmos / glanding & termination | 9954 | 2 NOS | 7,198 | 14,396 |
| Cable Termination Installation for 3.5Cx400sqmm LT Cable | cosmos / glanding & termination | 9954 | 2 NOS | 3,657 | 7,314 |
| E-House Foundation Civil Work | CIVIL JOB / INSTALLATION | 9954 | 1 JOB | 2,135,859 | 2,135,859 |
| E-House Shed Supply and Installation | INSTALLATION | 9954 | 1 JOB | 2,135,859 | 2,135,859 |
| Rubble Packing 250mm Thick for Cable Trench Reinstatement | CIVIL JOB / reinstatement | 9954 | 690 SQR MTR | 624 | 430,560 |
| Stone Metal 40-90mm Layer for Trench Reinstatement | CIVIL JOB / reinstatement | 9954 | 71 CUM | 7,276 | 516,596 |
| Water Bound Macadam WBM Layer for Trench Reinstatement | CIVIL JOB / reinstatement | 9954 | 185 SQR MTR | 556 | 102,860 |
| M10 Grade RMC Concrete Levelling Course | CIVIL JOB / RMC concrete | 9954 | 38 CUM | 11,811 | 448,818 |
| M40 Grade RMC Concrete Road Pavement | CIVIL JOB / RMC concrete | 9954 | 29 CUM | 16,367 | 474,643 |
| Interlocking Paver Blocks 100mm Thick | CIVIL JOB / Pever Block | HSN not specified by seller | 95 SQ MTR | 973 | 92,435 |
| Asphaltic Macadam Bitumen Grade 60 70 Regulating Course | CIVIL JOB / INSTALLATION | 9954 | 135 MT | 10,324 | 1,393,740 |
| Asphaltic Concrete Wearing Course Bitumen Grade 60 70 | CIVIL JOB / INSTALLATION | 9954 | 150 MT | 14,496 | 2,174,400 |
| Transporting Surplus Excavated Material Outside MbPA Estate | CIVIL JOB / trasportation | 9954 | 100 CUM | 1,882 | 188,200 |
| Dismantling of Existing Workshop Substation Equipment | CIVIL JOB / Dismentling | 9954 | 1 JOB | 2,419,023 | 2,419,023 |