Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC C 11 SITE IV INDUSTRIAL AREA SAHIBABAD GHAZIABAD GHAZIABAD UTTAR PRADESH 201010 | GHAZIABAD | UTTAR PRADESH | 201010 | ₹1.2 Cr | L1 | Accepted-AOC as per evaluation and award |
| 2 | L2₹1.4 Cr+₹27.6 L (23.6%)Rejected-AOC 2ND ROSHAN TOWER S B SHOP BISTUPUR AREA EAST SINGHBHUM JHARKHAND | BISTUPUR | EAST SINGHBHUM | JHARKHAND | 831001 | ₹1.4 Cr+₹27.6 L (23.6%) | L2 | Rejected-AOC as per evaluation and award |
| 3 | L3₹1.6 Cr+₹37.6 L (32.1%)Rejected-AOC 96 ELECTRONIC CITY COMPLEX BANGALORE KARNATAKA 560100 | BENGALURU URBAN | KARNATAKA | 560100 | ₹1.6 Cr+₹37.6 L (32.1%) | L3 | Rejected-AOC as per evaluation and award |
| 4 | L4₹1.7 Cr+₹52.0 L (44.3%)Rejected-AOC DOOR NO 48 50 PRAKASAM STREET SKCL HARMONY SQUARE T NAGAR T NAGAR CHENNAI TAMIL NADU 600017 | CHENNAI | TAMIL NADU | 600017 | ₹1.7 Cr+₹52.0 L (44.3%) | L4 | Rejected-AOC as per evaluation and award |
| 5 | L5₹2.2 Cr+₹99.2 L (84.5%)Rejected-AOC 56 57 HADAPSAR INDUSTRIAL ESTATE HADAPSAR PUNE MAHARASHTRA 411013 | PUNE | PUNE | MAHARASHTRA | 411013 | ₹2.2 Cr+₹99.2 L (84.5%) | L5 | Rejected-AOC as per evaluation and award |
Tender Value
Refer Docs
Closing Date
27 Nov 2019, 3:00 pmClosed
Dhanesh Parekh
Praj Tower 274 and 275 Bhumkar Chowk Hinjewadi Road Hinjewadi Pune411057
Distributed Control System as per MR no. S-17047-4-IMR1001
2019_REFHQ_105472_1
S-17047/4/CIII/MR/1046-DCS
Limited
Instrumentation-Goods
Supply
180 days
PANIPAT HARYANA
Not Applicable
6 documents required · 6 mandatory
Exempted
Pune
8 Aug 2022
25 Sept 2019
28 Nov 2019
25 Sept 2019
27 Nov 2019
16 Oct 2019
3 Oct 2019
Design, Engineering, Supply , Manufacture, Procurement , Inspection, Testing, Documentation , Packing , Delivery of Distributed Control System & communication interface network system as complete package, meeting the intent and of this specification including required Accessories, Mandatory Spares, Commissioning Spares ,Third party Inspection of the system as specified in Material Requisition (MR)/tender.
Four ( 4) man month system expert Engineer visit charges for installation supervision , commissioning , site training as specified in Material Requisition (MR)
Training charges for Training at Vendors / Bidder works as specified in Material Requisition (MR).
Post Warranty Comprehensive Annual Maintenance ( PWCAMC) Contract for 5 Years as per Material Requisition (MR)/Tender
PWCAMC-1st Year
PWCAMC-2nd Year
PWCAMC-3rd Year
PWCAMC-4th Year
PWCAMC-5th Year
Site supervision for installation, testing and commissioning for DCS system & communication interface network system as per MR/tender ( This is optional price in case of service is required in addition to site work as mentioned in S.I. No. 1.02
Per Diem charges for up to 8 hours on normal working days
Overtime rate/ hour beyond normal 8 hour work on normal working days
Per Diem charges for up to 8 hours on weekly off days/holidays(as applicable to site)
Overtime rate/ hour for work on weekly off days/ holidays ( as applicable to project site)
Applicable Hardware, Software Unit rate for Addition / Deletion for DCS system and Communication Interface Network system as per MR/tender specifications.
Set of redundant controller CPU module with redundant power supply module ,redundant communication interface module with Data highway & IO bus ,mounting chassis ,connectors & all other required accessories (specify make & model )
Analog Input Module with all accessories like terminal board , pre-fabricated cable etc. (specify make & model )
Analog Output Module with all accessories like terminal board , pre-fabricated cable etc. (specify make & model )
Digital Input Module with all accessories like terminal board , pre-fabricated cable etc.(specify make & model )
Digital Output Module with all accessories like terminal board , pre-fabricated cable etc. (specify make & model )
Power supply Module for Controller Rack (specify make & model )
power supply module for IO Rack (specify make & model )
communication Interface Module with Data highway & IO bus (specify make & model )
I/O rack communication interface module (specify make & model )
DCS System Modbus TCP/IP communication interface module (specify make & model )
DCS controller CPU Memory card (specify make & model )
Processor memory Backup Battery (specify make & model )
Industrial grade, managed, layer-2 Network Switch -8 port (specify make & model )
Industrial grade, managed, layer-2 Network Switch -16 port (specify make & model )
Industrial grade, managed, layer-2 Network Switch -32 port (specify make & model )
Industrial grade, managed, layer-2 Network Switch -64 port (specify make & model )
Analog Input IS ( Intrinsic Safe ) barrier (specify make & model )
Analog Output IS (Intrinsic Safe ) barrier (specify make & model )
Digital Input IS ( Intrinsic Safe ) barrier as per MR/tender specifications (Specify make & model)
Digital Output IS ( Intrinsic Safe ) barrier as per MR/tender specifications (Specify make & model)
24 V DC Bulk power supply : rating-10 A (specify make & model )
24 V DC Bulk power supply : rating-20 A (specify make & model no.)
24 V DC Bulk power supply : rating-40 A (specify make & model no.)
Operator Work Station ( with dual display monitor) (specify make & model )
Operating Work Station ( OWS) application software's and licenses
Engineering Work Station ( EWS) application software's and licenses
Network Printer with required accessories (specify make & model )
24”( inches) Wide , color display monitor with required accessories (specify make & model )
Interposing Relay Board (specify make & model )
19" rack mounted Light Interface Unit ( LIU) with fully loaded suitable type of connectors and accessories (specify make & model )
Fiber Optic (FO) media converter ( specify make & model)
SFP( Small Form-factor Pluggable) optical trans-receiver module of suitable type ( specify make & model)
Fiber Optic patch cord of suitable type of three (3)meter length ( specify make & model)
Fiber optic Pigtail of suitable type, connector and length ( specify make & model)
Industrial , armoured Ethernet Cat 6 / Cat 6a STP ( Shielded Twisted Pair) type network Cable ( specify make & model)
Industrial Ethernet RJ45 connector suitable for Cat 6 / Cat 6a STP cable ( specify make & model)
Optical Fiber Communication Cable: 6 no's Fibers, Multi-Mode, Armoured, Loose Tube corrugated steel tape Outdoor Cable ( specify make & model)
Floor standing Network cabinet with 19 " Rack mountable and 42 U height inclusive of required accessories & as per MR/tender specifications ( specify make & model)
System IO module pre-fabricated cable ( specify make & model)
Push button ( specify make & model)
Indicator lamp ( specify make & model)
Emergency Button ( specify make & model)
Digital Voltmeter ( specify make & model)
Digital Ammeter ( specify make & model)
Terminal Board ( specify make & model)
Fused Terminal Block ( specify make & model)
Non-Fused Terminal Block ( specify make & model)
Glass fused of each type and rating ( specify make & model)
Blank system cabinet (Rittal make) with power socket, receptacle and lighting along with required accessories of size 2000 ( H) x 800 ( W) x 800 ( D) ( specify make & model)
Work station mounting console with power socket and receptacle ( specify make & model)
Fan Failure and Temperature Detection Unit ( FFTDU) ( specify make & model)
72” Large Video Screen ( LVS) display ( specify make & model)
Cabinet cooling fan with mounting accessories ( specify make & model)
Cabinet illumination lamp assembly with mounting accessories ( specify make & model)
Cabinet filter and louver ( specify make & model)
System interconnecting cable ( specify make & model)
GPS clock for time synchronization with required accessories ( specify make & model)
Hardware Network Firewall with required accessories ( specify make & model)
1- Pole Miniature Circuit Breaker (MCB) of rating 2 A - 16 A ( specify make & model)
2- Pole Miniature Circuit Breaker (MCB) of rating 2 A - 16 A ( specify make & model)
2-Pole Miniature Circuit Breaker (MCB) of rating 16 A - 32 A ( specify make & model)
2-Pole Miniature Circuit Breaker (MCB) of rating 64 A ( specify make & model)
Molded Case Circuit Breaker (MCCB) of rating 50-100 A ( specify make & model)
Bus powered Portable Hard Drive 2 TB ( specify make & model)
Hooter ( specify make & model)
35 mm, 24 V DC Intrinsic Safe Barrier backplane power DIN rail bus ( specify make & model)
DCS controller CPU module with memory module and backup battery ( specify make & model)
Optical Fiber Communication Cable: 8 no's Fibers, Multi-Mode, Armoured, Loose Tube corrugated steel tape Outdoor Cable & as per MR\tender specifications. ( specify make & model)
Optical Fiber Communication Cable: 12 no's Fibers, Multi-Mode, Armoured, Loose Tube corrugated steel tape Outdoor Cable & as per MR\tender specifications. ( specify make & model)
Wall mount Network cabinet with 19 " Rack mountable and 6 U height inclusive of required accessories ( specify make & model)
Wall mount Network cabinet with 19 " Rack mountable and 9 U height inclusive of required accessories ( specify make & model)
Diode 'OR'ing module for 24 V DC redundant power supply module with accessories ( specify make & model)
DIN Rail mounted Relay 2 NO/NC ( specify make & model)
DIN Rail mounted Relay 4 NO/NC ( specify make & model)
12" Color , Touch screen HMI display screen with accessories ( specify make & model)
Unit rate required for engineering,installation, wiring, & testing services for addition /deletion per IO count for Analog Input ( AI). Specify activity name, type .
Unit rate required for engineering,installation, wiring, & testing services for addition /deletion per IO count for Analog Output ( AO). Specify activity name, Type-Qty-Unit .
Unit rate required for engineering,installation, wiring, & testing services for addition /deletion per IO count for Digital Input ( DI). Specify activity name, Type-Qty-Unit .
Unit rate required for engineering,installation, wiring, & testing services for addition /deletion per IO count for Digital Input ( DO). Specify activity name, Type-Qty-Unit.
DCS RS485 Modbus RTU Communication interface module
RS485 Modbus interface cable as per MR Tender Specification
RS485 repeater Module
Unit rate for addition / Deletion for any other item which is not covered above ( Mention the item name, Type-Qty-Unit in unpriced BOQ)
Unit rate for addition / Deletion for any other item which is not covered above ( Mention the item name, Type-Qty-Unit in unpriced BOQ)
Unit rate for addition / Deletion for any other item which is not covered above ( Mention the item name, Type-Qty-Unit in unpriced BOQ)
Unit rate for addition / Deletion for any other item which is not covered above ( Mention the item name, Type-Qty-Unit in unpriced BOQ)
Unit rate for addition / Deletion for any other item which is not covered above ( Mention the item name, Type-Qty-Unit in unpriced BOQ)
Unit rate for addition / Deletion for any other item which is not covered above ( Mention the item name, Type-Qty-Unit in unpriced BOQ)
Unit rate for addition / Deletion for any other item which is not covered above ( Mention the item name, Type-Qty-Unit in unpriced BOQ)
Unit rate for addition / Deletion for any other item which is not covered above ( Mention the item name, Type-Qty-Unit in unpriced BOQ)
Unit rate for addition / Deletion for any other item which is not covered above ( Mention the item name, Type-Qty-Unit in unpriced BOQ)
Unit rate for addition / Deletion for any other item which is not covered above ( Mention the item name, Type-Qty-Unit in unpriced BOQ)
Unit rate for addition / Deletion for any other item which is not covered above ( Mention the item name, Type-Qty-Unit in unpriced BOQ)
Unit rate for addition / Deletion for any other item which is not covered above ( Mention the item name, Type-Qty-Unit in unpriced BOQ)
Unit rate for addition / Deletion for any other item which is not covered above ( Mention the item name, Type-Qty-Unit in unpriced BOQ)
Unit rate for addition / Deletion for any other item which is not covered above ( Mention the item name, Type-Qty-Unit in unpriced BOQ)
Unit rate for addition / Deletion for any other item which is not covered above ( Mention the item name, Type-Qty-Unit in unpriced BOQ)
Unit rate for addition / Deletion for any other item which is not covered above ( Mention the item name, Type-Qty-Unit in unpriced BOQ)
Unit rate for addition / Deletion for any other item which is not covered above ( Mention the item name, Type-Qty-Unit in unpriced BOQ)
Description of Work / Item(s)
Spares
Description of Work / Item(s)
Cost Component
Direct Material Cost
Direct Labour Cost
Factory Overhead
SIemens Ltd.
ABB India Limited
Yokogawa India Limited
Honeywell Automation India Limited
Honeywell Automation India Limited
Yokogawa India Limited
Rockwell Automation India Pvt Ltd
ABB India Limited
ABB India Limited
Yokogawa India Limited
Honeywell Automation India Limited
SIemens Ltd.
US Dollar
European Euro
British Pound
Japanese yen
Singapore Dollar
Portion of Quoted Rate in Currency
US Dollar
US Dollar
US Dollar
US Dollar
US Dollar
US Dollar
European Euro
British Pound
Japanese yen
Singapore Dollar
Portion of Quoted Rate in Currency
US Dollar
European Euro
British Pound
Japanese yen
Singapore Dollar
Description of Work / Item(s)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .