| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.8 LAccepted-AOC | L1 | Accepted-AOC L1 accepted | |
| 2 | L2₹12.2 L+₹48,481 (4.12%)Rejected-Finance C O OPPOSITE MH MANDA POONCH ROAD AKHNOOR 181201 J K | JAMMU | JAMMU AND KASHMIR | 181201 | L2 | Rejected-Finance Other than L1 after deducting Sch of Credit for Rs 23511.00 | |
| 3 | L3₹12.3 L+₹53,092 (4.51%)Rejected-Finance | L3 | Rejected-Finance Other than L1 after deducting Sch of Credit for Rs 23511.00 | |
| 4 | L4₹12.4 L+₹65,948.40 (5.61%)Rejected-Finance | L4 | Rejected-Finance Other than L1 after deducting Sch of Credit for Rs 23511.00 | |
| 5 | L5₹16.1 L+₹4.3 L (36.5%)Rejected-Finance | L5 | Rejected-Finance Other than L1 after deducting Sch of Credit for Rs 23511.00 |
Tender Value
Refer Docs
EMD Value
₹27,600
Closing Date
8 Jun 2021, 6:00 pmClosed
GE North Akhnoor
GE North Akhnoor CO 56 APO
PROVN OF SECURITY LIGHTS WITH ALLIED INFRA AND SPECIAL REPAIR OF INTERNAL EXTERNAL ELECTRICAL WIRING SYSTEM OF OT AT MH AT AKHNOOR UNDER GE NORTH AKHNOOR
2021_MES_441850_1
GE(N)/AKH-09/2021-22
Open Tender
Civil Works
Item Rate
180 days
Akhnoor
CLASS E CATEGORY b i
8 documents required · 8 mandatory
₹500
Yes
GE North Akhnoor
₹27,600
Yes
24 Jun 2021
10 May 2021
10 Jun 2021
10 May 2021
8 Jun 2021
25 May 2021
Amount
Excavation in trenches not exc. 1.5m wide and not exc. 1.5m deep in soft/loose soil for laying of underground cable, foundation of poles & stays etc., and getting out, complete all as specified & directed.
Excavation in trenches exc. 1.5m deep in soft/loose soil for foundation of poles & stays etc., and getting out, complete all as specified & directed.
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25cm, complete all as specifed & directed.
Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified & directed.
Brick well burnt locally available sub class 'B' laid over sand cushioning for mechanical cable protection in trenches with width of brick perpendicular to the length of cable, complete all as specified & directed by Engineer-in-Charge.
Sand cushioning to under ground cable, laid in trenches 8cm thick below the cable and 15cm thick above the cable after laying and stretching the cable complete punned to 18cm, complete all as specified and directed. Note:- Punned thickness of sand will be measured and paid.
Supply, laying and testing XLPE insulated, electric cable (heavy duty) with stranded aluminium conductor, 1100 volts grade, heavy duty cable, cross-sectional area 25 Sqmm 4 core laid in trenches or passing through pipes complete all as specified and directed. (Earth work, brick protection and sand cushioning shall be measured and paid for separately)
Supply, laying and testing XLPE insulated, electric cable (heavy duty) with stranded aluminium conductor, 1100 volts grade, heavy duty cable, cross-sectional area 16 Sqmm 4 core laid in trenches or passing through pipes complete all as specified and directed. (Earth work, brick protection and sand cushioning shall be measured and paid for separately)
Supply, laying and testing XLPE insulated, electric cable (heavy duty) with stranded aluminium conductor, 1100 volts grade, heavy duty cable, cross-sectional area 70 Sqmm 3.5 core laid in trenches or passing through pipes including taking down old existing unserviceable cable complete all as specified and directed. (Earth work, brick protection and sand cushioning shall be measured and paid for separately)
S&F in repair for 50mm bore Tubes, 'light grade', galvanised, for cable protection fixed on poles or laid in trenches under floor,/under road, ducts etc with fixing clamps, nuts, bolts etc complete all as specified and directed.
M&L for 40mm bore Tubes, 'light grade', galvanised, for cable protection fixed on poles or laid in trenches under floor,/under road, ducts etc with fixing clamps, nuts, bolts etc complete all as specified and directed.
Steel tubular swaged poles in vertical position/as strut poles swaged type 410-SP-31, 9 Mtr long, ISI marked complete with cast iron base plate, finial taper plug, bolts, nuts washers and screws as required duly painted with two coats of aluminium paint over a coat of red oxide primer above ground level including painting below GL (externally) with two coats of bituminous paint, numbering of poles with cut stencil lettering in size 6mm thick and 50mm high and white and black strips of size 30cm width each with synthetic elamel paint upto 1.5m above coping etc, complete all as specified and directed. Note:- 1. Earth work and PCC will be measured and paid seperately under appropriate items.
M&L for PCC (1:2:4) type B1 using 20 mm graded stone aggregates as in coping of poles etc including weathering, slightly rounded or chamfered angle and throating, necessary form work finishing all exposed faces of concrete etc complete all as specified and directed by Engr-in-Charge.
M&L for PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in foundation of pole, bed concrete of poles incl necessary form work , fair finished to exposed surfaces without using extra cement complete, all as specified and directed by Engr-in-Charge.
Supply and fixing weather proof flat twin core PVC insulated & sheathed Aluminium stranded conductor cables 2.5 sqmm drawn through street light pole duly making the hole upper and down both place and connection the street light to DB Box all as specified and directed by Engr-in-Charge.
S&F new generation energy saving and environmental friendly long life LED street light of 60W made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP65 protection and impact resistance of IK07 including GI bracket made of 40mm dia light grade GI tube 1.2 metre bend to shape with 02 nos FI clamp of 32x4mm with nuts, bots, washers, making connection with PVC copper conductor cable of appropriate size, complete all as specified & directed. Make : Havells Cat Part No.ENDURAPEARLNEOSL60WLED757PASYTOPC or equivalent of Philips/ Crompton Greaves/ Bajaj or equivalent.
M & L for manufacture Sheet metal enclosure connection box of size 300mmx250mm x150mm made out of GI sheet of 3mm thick and powder coated water proofing including arrangement and providing MCB 40 amp TP (one No) with netural bus bar 200 Amp and MCB SP 6 Amp-(one No). including fixing arrangement to steel tubular pole complete all as specified and directed.
Suppy and fixing of bracket made out of 40mm dia GI medium grade tubing 2 metre long and bent to shape at 120 degree angle at one metre from bottom (as per sample), including M & L for MS clamps, back plates fabricated from structural steel section 50 x 6mm , including nuts, bolts, washers, welding cold or hot, drilling of holes for bolts, in any shape or size including two coats of Aluminium paint over a coat of Red oxide primer after preperation of steel surfaces complete all as specified and directed by Engr-in-Charge.
S&F Earthing of galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr depth below normal ground level) with top edge of earth not less than 1.5 metre below normal ground level, surrounded on all sides by 150mm thick charcoal & common salt starting from ground below earth plate upto 150mm above GI plate in alternate layers connected to and including earth lead wire 4.0mm (8SWG) by means of steel bolts, nuts, check nuts and washers, test point made of GI strip 40x8mm, 10cm long PCC 1:2:4, type B-1 in pit with precast RCC 1:2:4 type B-1 in cover reinforced with XPM not less than 4 Kg per Sqm with 15mm bore GI light grade protection pipe, 20mm bore GI medium grade watering pipe with funnel including charcoal, dust, salt, all as shown in electrical plate No 3 of SSR Part-I (2009) with necessary earth work in any type of soil, removal to a distance not exceeding 50 mtr, including testing on completion, complete all as specified & directed. Note : (a) The cost of earth work, PCC pit of size shown in electrical plate No.3, funnel, watering pipe, wire mesh, charcoal, dust, common salt, 20mm bore medium grade watering pipe & 15mm bore light grade GI pipe as protection to earth lead wire etc shall be deemed included in the unit rate for earthing. (b) After completion, during testing, if the earth resistance equal or less 2 ohms is not obtained, earthing will be regenerated at no extra cost till the desired earth resistance is obtained.
Taking down carefully, copper / aluminium conductor unserviceable / perished point wiring (any type) for light/ fan/ light socket or power socket etc complete with fittings such as switches, sockets, ceiling roses, pendant holders, bracket holder, light fittings, regulators etc, including making good to disturbed surfaces of wall/floor etc, complete, all as specified & directed.
M & L for sub main wiring complete with 2 run of 4 sqmm single core copper conductor (ISI marked)cable 1100 volts grade,FRLSH type, PVC insulated, unsheathed, flexible,multi stranded colour coded cables drawn through and including rigid PVC conduit of size 25 mm dia medium grade(MMS) with all connected accessories such as Bend,Tee,Elbow,Short peices etc concealed in wall/roofs/floors and including one run of 4 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade,FRLSH type as earth continuity conductor connected to common earth dolly and including making good the disturbed surfaces to match with existing surface including cutting and cheasing including taking down existing old and unserviceable sub main wiring complete all as specified and directed. Make of Cable Havells, KEI, Anchor Note : - Two run of4 sqmm single core copper conductor cable and one run of 4 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit.
M & L for sub main wiring complete with 2 run of 6 sqmm single core copper conductor (ISI marked)cable 1100 volts grade,FRLSH type, PVC insulated, unsheathed,flexible,multi stranded colour coded cables drawn through and including rigid PVC conduit of size 25 mm dia medium grade(MMS) with all connected accessories such as Bend,Tee,Elbow,Short peices etc concealed in wall/roofs/floors and including one run of 6 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade,FRLSH type as earth continuity conductor connected to common earth dolly and including making good the disturbed surfaces to match with existing surface including cutting and cheasing including taking down existing old and unserviceable sub main wiring complete all as specified and directed. Note : - Two run of 6 sqmm single core copper conductor cable and one run of 6 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit.
Material and labour for point wiring complete with 1.5 sqmm PVC insulated, FRLS type, ISI marked,conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through including PVC Conduit 20 mm dia medium grade and including cutting, chasing work at any height and all accessories are concealed in walls / roofs / floors / ceiling etc. flush mounting MS box with top,bottom,side/back wall knockout for conduit entry from any direction made out of 1.60mm thick suitable for fixing of modular top cover plate as per numbers of switch modules for modular switches,sockets,fan regulators,red colour indicator, blank plates etc as approved coloures and including 1.5 Sqmm PVC insulated multistranded FRLS type unsheathed(Green colour),single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providing putty and white cement for smooth finishing of existing surface) for One light point/fan/bell point controlled by one switch complete all as specified and directed. Make of Cable Havells,KEI,Anchor (Note:-All necessary accessories such as modular steel box,top cover plate, blank plate, screws,washers and all modular electrical fixtures are to be used same make/brand only and shall be deemed in to included in quoted rate only.)
All as per Srl item No. 23 here-in-above but for One 5 pin 6 amps socket point controlled by one 6 amps switch on independent board .
All as per Srl item No. 23 here-in-above but for One 5 pin 6 amps socket point controlled by one 6 amps switch on same board .
All as per Srl item No.23 here-in-above,but point wiring with 2.5 sqmm and earth conductor of size 2.5 sqmm for One 6 pin 16/6 amps socket outlet point controlled by one 16 amps switch on independent board complete all as specified and directed. Make of Cable Havells, KEI, Anchor
Supply & fixing modular type switch 6 Amps, single pole,1 way, 1 module,240V, ISI Marked complete all as specified and directed. Make : Indoasian Glint, Crabtree, Anchor
Supply & fixing modular type switch 16 Amps, single pole, 1way, 1 module,240V, ISI Marked Complete all as specified and directed. Make : Indoasian Glint, Crabtree, Anchor
Supply & fixing modular type socket shuttered type 6 Amps, 2/3 Pin combined 2 module,240V,AC ISI Marked Complete all as specified and directed. Make : Indoasian Glint, Crabtree, Anchor
Supply & fixing modular type socket 6 A/16 Amps, 2/3 Pin combined shuttered socket 2 module with light indication ,240V,AC ISI Marked Complete all as specified and directed . Make : Indoasian Glint, Crabtree, Anchor
Supply & fix fan regulator modular type electronic, stepped type, 100 Watts, 2 module, 240Volts, AC, ISI marked complete all as specified and directed. Make : Indoasian Glint, Crabtree, Anchor
Supply & fix angle lamp holder, insulated body with back plate for batten fittings complete all as specified and directed. Make : Indoasian Glint, Crabtree, Anchor
Supply & fixing LED lamp B22 base type complete all as specified and directed. Make : Havells/ Anchor/C&S
Supply & fix ceiling rose, 3 terminal ,PVC/polycarbonate body ISI marked, complete all as specified and directed
Supply and fixing buzzer, ding dong AC, 230 volts single pole. Make : Havells/ Indoasian/Anchor
S & F modular bell push 6A , 1 module, complete all as specified and directed. Make : Indoasian Glint, Crabtree, Anchor
Supply and fixing VTPN verticle loadline double door distribution box (DB) are fitted with Bus bar neutral link, blanking plates of 4 way with suitable for incomming MCCB 'I/C' frame, having isolated neutral bar, mechanical impact strength IK09, door earthing suitable for MCCB upto 125 Amp. Make -Indoasian part No- 811888 or its equivalent in Havells ,Legrand, L & T etc.
Supply and fixing sheet metal enclosure double door type for DBs single pole and neutral 8 way 240 V complete all as specified and directed. Make -Indoasian , Havells ,Schnieder etc.
Supply and fix MCCB TPN 415 volts 16 KA, 63 Amp suitable for TPN vertical loadline DB mentioned at Srl Item No 37 here in before. Make -Indoasian part No- 811220 or its equivalent in Havells ,Legrand, L & T etc.
Supply & fix MCB SP 6 to 32 Amps 10 KA,"C" series, AC, 240Volts,50Hz , ISI marked complete all as specified and directed. (In accordance with IS/IEC 60898-1) 240 V/, 50 Hz, 10 kA Suitable ) Make -Indoasian part No- 811114 to 811129 or its equivalent in Havells ,Legrand, L & T etc.
Supply & fix MCB SPN 32 Amps 10 KA,"C" series, AC, 240Volts, 50Hz, ISI marked complete all as specified and directed. (In accordance with IS/IEC 60898-1) 240 V/, 50 Hz, 10 kA Suitable ) Make -Indoasian part No- 811132 or its equivalent in Havells ,Legrand, L & T etc.
Material and labour for Earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directely in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipe of 15 mm dia from earth electrode up to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber 1:3:6 type C1, of size 45X 45X 45 CM, RCC cover 1:2:4 type B1 of size 45X45X6 CM, excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required value including dismantling of existing earthing complete all as specified and directed. Note:- The required resistance of Earthing shall be less than 3 ohm, if found to the required resistance, the contractor has to re earthing for required resistance and the cost for the same included in the quoted rate and no extra shall be paid on failure of getting required resistance.
S& F in replacement of Energy saving 10 Watt LED Bulk head luminaries, 230V, 50Hz with oval shape, surface mounted, comprising high brightness LEDs complete all as specifed and directed. Make- Havells, Cat part No RUGBYNEONFT10WLED760SSYMBOPC or its equivalent in Bajaj, Philips, Crompton Greaves etc.
Taking down unserviceable flourescent fitting and M & L for LED batten Regal suitable for T8 LED tube including T8 LED tube crystal glass with very high efficacy suitable for installation in existing T8 fitting with G13 lamp 20Watt 4 ft white all as specified and directed. Make : Havells Part No for batten- REGALBATTENT8UPTO1X22W DSBSWH, Cat Part No- LED Tube T8 : CRYSTAL1213T8DSTL20WLED865SGLASS or equivalent in CG, Philips, Bajaj etc. Note :- Rate quoted include the cost of both batten and Tube rod T8 and shall match with the batten.
Supply and fix in replacement of 34 watt LED light fitting, size 2' x2' environmental friendly, new generation, aesthetically designed, ultra modern recess mounting luminaire with high brightness SMD LEDs as light source, suitable for Armstrong/Grip ceiling. Make- Havells, Cat No-PLUTONEO2X2PLR34WLED857S or its equivalent in CG, Philips, Bajaj etc.
Taking down the existing ceiling fan and hanging the same and connecting upto including provision of cable from ceiling rose or connector to fan.
Preparation of old surfaces of ceiling fans by scrapping old existing paint with the help of emery paper/wire brush including filling the cavities and painting in situ with two coats of white synthetic paint over a coat of red oxide primer with the help of spray machine including rewriting MES SL No all as specified and directed.
M&L for sheet metal enclosure box single pole and neutral enclosure with 2 pin & earth plug & socket complete with one single pole MCB 20 Amp, 240 volt all as specified and directed. Make : Indoasian,Havells, Anchor
Usha Engineering Co.
Jiwan Singh
Ankush Gupta
M/S KAPIL KUMAR KHATTAR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .