Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹6.2 CrAccepted-AOC | ₹6.2 Cr Quoted ₹6.3 Cr | L-1 | Accepted-AOC L-1 bidder |
| 2 | L-2₹7.3 Cr+₹1.0 Cr (16.1%)Rejected-Finance | ₹7.3 Cr+₹1.0 Cr (16.1%) | L-2 | Rejected-Finance Not Validated |
| 3 | L-3₹7.4 Cr+₹1.2 Cr (18.5%)Rejected-Finance | ₹7.4 Cr+₹1.2 Cr (18.5%) | L-3 | Rejected-Finance Not Validated |
| 4 | L-4₹8.0 Cr+₹1.7 Cr (26.9%)Rejected-Finance JAIN TEMPLE ROAD DIMAPUR 797112 NAGALAND | DIMAPUR | DIMAPUR | NAGALAND | 797112 | ₹8.0 Cr+₹1.7 Cr (26.9%) | L-4 | Rejected-Finance Not Validated |
| 5 | L-5₹10.0 Cr+₹3.7 Cr (58.9%)Rejected-Finance A 153 HQ CE EC KOLKATA LEKHAPANI POST TINSUKIA DIST ASSAM STATE | ₹10.0 Cr+₹3.7 Cr (58.9%) | L-5 | Rejected-Finance Not Validated |
Tender Value
Refer Docs
EMD Value
₹3.5 L
Closing Date
16 Jul 2021, 6:00 pmClosed
HQ CE SILIGURI ZONE
HQ CE SILIGURI ZONE, PO SALUGARA, DIST JALPAIGURI 734 008 WB
COMPLETION OF INCOMPLETE WORK OF PROVN OF OTM ACCN FOR INF BN NO 2 (PH-I) AT TENGA
2021_MES_439297_1
89290/TENGA/RandC/SZ/E8
Open Tender
Civil Works
Lump-sum
365 days
TENGA
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,000
GE 859 EWS
₹3.5 L
Yes
7 Sept 2021
29 Apr 2021
19 Jul 2021
29 Apr 2021
16 Jul 2021
28 Jun 2021
29 Apr 2021 - 20 May 2021
Amount
BUILDINGS / WORKS (Sch 'A' PART-I)
Lump sum price worked out by the Contractor for “BUILDINGS / WORKS” as listed in Schedule ‘A’ Part-I Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 88,28,310.00 inserted by the MES in Schedule ‘A’ Part-I.
SITE CLEARANCE, SITE DEVELOPMENT, EXCAVATION AND EARTH WORK (Sch 'A' PART-II)
Lump sum price worked out by the Contractor for “SITE CLEARANCE, SITE DEVELOPMENT, EXCAVATION AND EARTH WORK” as listed in Schedule ‘A’ Part-II. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 4,79,330.52 inserted by the MES in Schedule ‘A’ Part-II.
INTERNAL WATER SUPPLY (Sch 'A' PART-III)
Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part-III. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 42004.01 inserted by the MES in Schedule ‘A’ Part-III.
INTERNAL ELECTRIFICATION (Sch 'A' PART-IV)
Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION ” as listed in Schedule ‘A’ Part-IV. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 53328.15 inserted by the MES in Schedule ‘A’ Part-IV.
EXTERNAL WATER SUPPLY (Sch 'A' PART-V)
Lump sum price worked out by the Contractor for “(EXTERNAL WATER SUPPLY)” as listed in Schedule ‘A’ Part-V. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 2,18,368.57 inserted by the MES in Schedule ‘A’ Part-V.
EXTERNAL ELECTRIFICATION (Sch 'A' Part-VI)
Lump sum price worked out by the Contractor for “(EXTERNAL ELECTRIFICATION)” as listed in Schedule ‘A’ Part-VI. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 4,05,103.72 inserted by the MES in Schedule ‘A’ Part-VI.
SEWAGE DISPOSAL (Sch 'A' Part-VII)
Lump sum price worked out by the Contractor for “(SEWAGE DISPOSAL)” as listed in Schedule ‘A’ Part-VII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 7,15,245.67 inserted by the MES in Schedule ‘A’ Part-VII.
AREA DRAINAGE (Sch 'A' PART-VIII)
Lump sum price worked out by the Contractor for “(AREA DRAINAGE)” as listed in Schedule ‘A’ Part-VIII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 4,72,441.75 inserted by the MES in Schedule ‘A’ Part-VIII.
ROAD, PATH, CULVERT (Sch 'A' Part-IX)
Lump sum price worked out by the Contractor for “(ROAD, PATH, CULVERT)” as listed in Schedule ‘A’ Part-IX. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 8,68,805.86 inserted by the MES in Schedule ‘A’ Part-IX.
FENCING / GATE (Sch 'A' Part-X)
Lump sum price worked out by the Contractor for “(FENCING / GATE)” as listed in Schedule ‘A’ Part-X. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 1,25,826.68 inserted by the MES in Schedule ‘A’ Part-X.
RETAINING WALL (Sch 'A' Part-XI)
Lump sum price worked out by the Contractor for “(RETAINING WALL)” as listed in Schedule ‘A’ Part-XI. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 4,79,663.10 inserted by the MES in Schedule ‘A’ Part-XI.
LIGHTNING PROTECTION (Sch 'A' Part-XII)
Lump sum price worked out by the Contractor for “(LIGHTNING PROTECTION)” as listed in Schedule ‘A’ Part-XII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 30,285.31 inserted by the MES in Schedule ‘A’ Part-XII.
MISCELLANEOUS ITEMS REQUIRED FOR B/R & E/M SERVICES (Sch 'A' Part-XIII)
INTERNAL ELECTRIFICATION M&L point wiring with 1.5 Sqmm (nominal area) fire retardant, PVC insulated 1100 volts grade multi stranded copper conductor single core cable drawn through and including PVC concealed conduits of adequate size with all fittings and accessories including sunk mild steel terminal boxes with 3mm thick plastic laminated sheet top cover complete including PVC insulated multi stranded copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly for:- Item continued as 13.02 to 13.04 NOTE : Cost of cutting chases for laying concealed conduit and making good is deemed to be included in the lump sum cost of the respective buildings.
One light point controlled by one, one way switch
One fan point controlled by one way switch
One socket outlet point 5 A on independent board
All as per item No. 13.01 but with 2.5 sqmm cable for 15 Amp socket on independent board and 1.5 Sqmm for earth continuity conductor.
All as per item No. 13.01 but with 4 sqmm cable for 15 Amp industrial socket and 1.5 Sqmm for earth continuity conductor on independent board.
S & Fix telephone jack RJ11. Make Havells / Anchor
M & L for point wiring of telephone line concealed with PVC conduit suitable for telephone wire twin core superior quality including all accessories. NOTE : Cost of cutting chases for laying concealed conduit and making good is deemed to be included in the lump sum cost of the respective buildings.
Fixing only box type luminaire fitting for single 1x 36/40 watt fluorescent lamp comprising of choke, capacitor, lamp holders, starter, starter holder, connector block etc„ prewired suspended from ceiling by providing double stiff pendant of 20 mm dia all as specified and directed including electrically connecting with and including twisted three core PVC insulated flexible cord of 0.5 Sqmm copper conductor from ceiling rose to light fitting complete all as specified. NOTES:- (a) Stiff pendant shall be measured and paid separately under appropriate item of this schedule. b) Fluorescent tube fitting and fluorescent tube will be issued under sch 'B' as 'free for fixing'.
Fixing only on wall/ ceiling box type luminaire fitting for single 1 x 36 watt flourescent lamp comprising of choke, capacitor, lamp holders, starter, starter holder, connector block etc.. prewired including provision of PVC round block and electrically connecting with and including twisted three core PVC insulated flexible cord of 0.75 Sqmm copper conductor from ceiling rose to light fitting complete all as specified. (NOTE : Fluorescent lamp and fitting will be issued under sch 'B' free for fixing).
Fixing only on ceiling, mirror optics luminaire fitting for single 2 x 36/40 watt fluorescent lamp comprising of choke, capacitor , lamp holders, starter, starter holder, connector block etc. prewired including provision of PVC round block and electrically connecting with twisted three core PVC insulated flexible cord of 0.50 Sqmm copper conductor from ceiling rose to light fitting complete all as specified. NOTE :- Fluorescent lamp and mirror optic fitting shall be issued under Sch 'B' free for fixing.
S & F surface mounting CFL lamp suitable for 2 X 36 Watts CFL lamp incl yellow colour lamps, complete with all standard accessories and electrically connected complete all as specified. (Model No BLWS236 of Bajaj or eqv in Crompton Greaves/Philips/Havells).
S&F for mirror light fitting/surface mounting suitable for 11W CFL as per Cat Part No BJC 111 of Bajaj Make or equivalent in Crompton Greaves/Philips. (Notes : CFL 11 W will be issued under Sch 'B" as free for fixing )
S&F bulk head luminaire suitable for 1 x 18 Watt CFL including lamp. (Make : CBH 18 of Cromton Greaves or equivalent in Philips)
S&F circular luminaire suitable for 1 x 25 watt CFL lamp incl all connected accessories end, CFL lamp, Model No CDL BCS 1901 of Philips or eqv in Havell's/ Crompton Greaves/Bajaj.
Supply, fix, test and commissioning building security luminaire complete with lamp, lamp holder, and all standard fittings / accessones suitable for CFL 1 x36 Watts. The cost includes fixing by 25 mm bore medium grade GI pipe (as per the opening in luminaire) bracket of adequate length, clamped to building and incl electrical connection from connector to light fitting. Clamp shall be fabricated out of MS flat of 25 x 3 mm with nut & bolt. Model No BJSLA 136 CFL of Bajaj make or equivalent in Crompton GreaveslPhilips
Supply and fix epoxy powder coated distribution box TPN 4 way, double door, grouted flush to walls vertical system.
Supply and fix epoxy powder coated distribution box SPN 12 way for MCBs grouted flush to wall double door.
Supply and fix epoxy powder coated distribution box SPN 8 way for MCBs grouted flush to wall double door.
Supply and fix sheet metal enclosure double pole for fixing MCB. Model No. 01356 of Legrand or eqv.
S&F MCBs of min 10 KA rupturing capacity of the following rating and to be housed in DBs catered here in before complete all as specified :- Item Continued as 13.22 to 13.29
(a) Isolator 4 pole, 63 Amps, 440 Volts.
(b) Isolator 4 pole, 32 Amps, 440 Volts.
(c) SPN 63 Amps, 240 Volts.
(d) SPN 40 Amps, 240 Volts.
(e) SPN 6-32 Amps, 240 Volts.
(f) SP 40 Amps, 240 Volts.
(g) SP 6 - 32 Amps, 240 Volts.
(h) Blanking plate
M&L sub main wiring with two runs of single core fire retardant PVC insulated and unsheathed multistranded, copper conductor cable of size 6.0 sq mm LT 1100 volts grade drawn through and including adequate sizes PVC concealed conduit (not less than 20 mm bore) accessories and fittings and one run of 2.5 sqmm single core multistranded copper conductor cable as earth continuity conductor. (NOTE : Two runs of cable, one run of earth wire and one run of conduit shall be measured as one run length Cable required for connection to DBs shall deemed to be included and shall not be measured separately. Earth wire shall run inside the conduit. (Extra length of cable rewired for connection to MCB's shall deemed be included in unit rate.)
All as per above item No 13.30 here-in-before but cable of size 4 Sq mm and 2.5 Sqmm as earth continuity.
All as per above item No 13.30 here-in-before but cable of size 2 5 Sq mm and 1.5 Sq mm as earth continuity.
S & F for double stiff pendant comprising of galvanised steel chromium plated brass bell mouth connectors 2 Nos with back plate and 2x 0.75 metre long paralled 20mm dia stove enamelled black screwed steel conduit with two check nuts for fixing tube light fittings complete all as specified and as directed
M & L for sheet metal enclosure with socket and plug top single pole & neutral with a two pin & earth plug & socket complete with one single pole MCB 16 Amps, 240 volts.
INTERNAL WATER SUPPLY Supply & fix Shower rose chromium plated with or without swivel joints 70 mm dia and fixing to steel pipe or union 15 mm bore complete all as specified and as directed.
Supply and fix 3 layered (outer green coloured UV stabilized, middle black coloured UV stabilized and innermost layer white coloured with antimicrobial property) fusion welded PP - R (Polypropylene Random Co - Polymer) pipes and fittings including plain PP - R fittings and brass threaded PP - R fittings and clamping, cutting and making good to the damages of grade PN - 16, SDR - 7.4 of following sizes:- Item Continued as 13.37 to 13.39
(a) 20 mm outer dia of pipe
(b) 25mm outer dia of pipe
(c) 32 mm outer dia of pipe
Supply and fix 3 layered (outer green coloured UV stabilized, middle black coloured UV stabilized and innermost layer white coloured with antimicrobial property) fusion welded PP - R (Polypropylene Random Co - Polymer) stop valve, screwed both ends for PP - R pipes or for unions fixed all as specified of grade PN - 16, SDR - 7.4 light weight complete all as specified and as directed.
(a) 20 mm outer dia of pipe
(b) 25mm outer dia of pipe
(c) 32 mm outer dia of pipe
EXTERNAL WATER SUPPLY S&F CI Sluice valve with SS spindle double flange conforming to IS-14846 both end flanged class PN 1.0 of size 80 mm dia including necessary nuts, bolts, washer and gasket complete all as specified and directed.
Supply, install, test and commissioning Pressure Filter of capacity 22000 Ltr/hrs made out of MS sheet steel conforming to IS-2062, duly painted with one coat of red oxide primer and two coats of rubberised paint inside the cylindrical tank and one coat of red oxide primer and two coats of synthetic enamel paint on outer surface of the cylindrical tank. The cylindrical tank shall have opening for inspection on the top of the tank with MS ladder to reach inspection chamber including PCC foundation connecting to inlet and out let pipe lines with flanged joints, with foundation legs/ channels, pressure gauge, in built back washing and rinsing arrangement, air vent, all other safety devices, including media comprising of pebbles, gravels and special white quartz sand as per standard specification and PVC strainer of suitable size including inlet and outlet wash out valve gate type complete duly connected to pumps The design of filter shall conform to IS -2825. The filter shall have suitable underdrain system and shall have the capacity to withstand double the working pressure on test complete all as specified and as directed.
EXTERNAL ELECTRIC SUPPLY Supply, lay, testing and commissioning UG cable XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor earthed 11KV grade of size120 Sqmm 3 core earthed complete all as specified and directed.
Laying only including testing, jointing and commissioning of LT under ground cable, 1100 volts grade, PVC insulated and PVC sheathed heavy duty armoured with multistranded aluminium conductor laid in pipes, trenches/ducts, on poles etc of the under mentioned type and sizes complete all as specified. Item Continued as 13.48 to 13.54 NOTE : 1. Clamps, sand cushioning, PCC/Brick protection, GI pipes for cable protection, excavation/ earthwork are out of the scope of this item and shall be measured and paid under separate items catered for in this schedule. 2. Cables will be issued under Sch 'B' as free for fixing/laying.
(a) 16 Sqmm 2 Core
(b) 16 Sqmm 4 Core
(c) 25 Sqmm 4 Core
(d) 35 Sqmm 3.5 Core
(e) 70 Sqmm 3.5 Core
(f) 6 Sqmm 2 Core
(g) 10 Sqmm 2 Core
S&F Time Switch 250 V single phase of 20 Amps rating with contactor fitted inside steel enclosure complete.
Supply, install, testing and commissioning step down transformer, outdoor type, plinth mounted HT 11 KV, 3 phase 433 volts, 4 wire, 50 Hz, delta/star connected, vector group DYN -11 double copper wound, ONAN, manual type off load tap changing facility on HT side to vary secondary voltage from minus 7.5% to plus 7.5% in steps of 2.5 %, continuous rating of capacity 160 KVA incl bushing on HT end cable box on LT side. The transformer shall be complete with all standard fittings and accessories, gauges, first fill of transformer oil, etc, and conforming to IS 2026 duly mounted on plinth and all as specified and as directed. (NOTE :- The cost of PCC plinth shall be measured & paid separately)
Supply & fix HT lightning arrestors for out door use metal oxide filled non-linear zinc oxide type complete with all fittings, station class III, 10 Kilo amps rupturing capacity suitable for 12 KV grade conforming to IS 3070 complete all as specified and directed.
Supply and fix cable jointing kit for 11 KV grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 120 Sqmm to 185 Sqmm complete all as specified and directed.
Supply, fix, test and commission flood light luminaires, complete with lamp, lamp holder, control gear standard fittings/ accessories suitable for 1 x 400 Watts MH lamp including electrical connection to the light fitting complete all as specified.
Supply, fix, testing and commissioning street light luminaires complete with lamp, lamp holder, choke, ignitor (as applicable) acrylic diffuser and standard fittings / accessories suitable CFL 1 X 36 Watts, The cost includes fixing by 40 mm bore 'medium grade' GI pipe bracket of adequate length bent to shape clamped to poles, Clamp,nuts & bolts arid washers and electrically connected from junction box to street light luminaire. Clamp shall be fabricated out of MS flat of 40 x 3mm including nut & bolt, complete all as specified and as directed.
Supply & fix triple pole, switches, air break, gang operated, arching horn type mechanically operated, mounted on insulator and steel frame complete with operating mechanism worked from ground level for current rating upto 200 Amps for 11000 volt complete all as specified.
Supply & fix double compression copper stainless steel gland for fixing armoured cables in panel of following size complete all as specified and directed :- Item Continued as 13.66 to 13.69
(a) 3.5 core 70 Sqmm
(b) 4 core 25 to 35 Sqmm
(c) 4 core 16 Sqmm
(d) 2 core 6 to 16 Sqmm
S&F Post top lantern fitting suitable for 125 Watt SV lamp complete with all lamp, alloy cylindrical spigot, decorative acrylic bowl supported by spun aluminium top cover and other connected accessories, electrical connections etc complete all as specified and directed. (NOTE : Excavation, earth work, PCC, GI pipe will be measured and paid separately.)
S&F Junction box made out of 3.15 mm thick MS sheet of size 120 mm X 160 mm with locking arrangement including MCB SPN 6 to 32 Amps of suitable size duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and fixing arrangement with MS clamp etc complete all as specified and as directed
SEWAGE TREATMENT PLANT Supply install, testing and commissioning of Central Sewage Plant of capacity 150 Cum/assembled all- in - one package Model No FMR 150 of ION Exchange or eqv in Thermax, consisting of following equipment and making all necessary electric connection from existing source, pipe line etc complete as per manufacturer's specification and all as directed by Engr -in Charge:- Eqpt details:- (a) RCC FMR Tank, Inside epoxy painted, all fittings inside i.e. Lamella plate settler should be MS, FRP coated. (b) Sludge transfer Pump - 02 Nos of adequate capacity as per manufacturer design (c) Air blowers - 02 Nos as per manufacturer's specification (d) Lamella Plate Clarifier - as per manufacturer's specification (e) Chemical dozing system - 01 No as per Manufacturer's specification (f) Equalization tank of size 4.50 x 4 50 x 2.50 Mtr with RCC foundation, walls, cover slab including excavation complete- 01 Job (g) Sludge drying bed in combination of 4 Nos of drying beds of size 2.25 x 2.25 x 1 5 Mtr with RCC foundation, walls, cover slab including excavation complete - 01 Job (h) All civil works as per manufacturers instruction.
NOTE for Srl Item No. 13.72 :- 1. Cost of PCC platform and all other relevant Civil works is deemed to be included in the unit rate. 2. Installation, testing and commissioning of plant to be carried out in presence of authorised rep of Manufacturers. 3. 90.55% work has been completed at site. Bidder to ascertain the quantum of balance work to be carried out before quoting.
EXTERNAL WATER SUPPLY S&F Galvanised steel water tubing 100 mm bore medium grade with all fittings and laying in trenches/ fixed to structral steel staging including MS clamps, bolts and nuts complete etc
Supply and fix aviation obstruction light neon spiral with built in step up transformer 75 VA and all standrad accessories complete including all electrical connections. Make: Bajaj, Model - BJAOL-1 or equivalent in Crompton Greaves/Phlips. NOTE:- Cable for electrical connections will be measured and paid separately under relevent items.
SEWAGE TREATMENT PLANT Supply and install Non Clog sewage centrifugal electric driven pump incl 3 phase 415 volts motor of suitable rating of 10 HP for sewage containing solids upto 2.5" size including all necessary electrical and piping connections.
Supply & fix fully automatic star-delta starter 3 phase, 50 Hz, 415 V of relay range 9-14 Amp rating on LT panel with necessary arrangement and connection of the U/G cable to pump motor of 12.5 HP complete as per direction of Engr-in- Charge
Supply & fix MCB SPN-16 Amps rating with 2 way DB fixed to wall with wooden box and necessary arrangement for connection of Air blower for chlorination plant with 2 core 6 Sqmm U/G cable complete. (NOTE : Cable shall be measured,and paid separately against item No. 13.47 here-in-before.
Supply and lay ductile iron pipe centrifugally cast (Spun) with spigot and socket ends conforming to IS 8392 /2000 in standard length for classification K9 100 mm nominal dia suitable for push on joints (Rubber Gasket D jointing) with cement mortar lining inside the pipes without side zinc coating including masonary support wherever required.
All as per item No 13.80 above but 150mm dia.
S&F CI sluice valve double flange conforming to IS 14846 both end flanged class PN 1.0 of size 150 mm dia incl necessary nuts, bolts, washer and gasket all as directed by Engineer in charge and all as specified.
All as per item No. 13.82 here-in-before but 100mm dia.
S&F pressure meter with valve ranges from 0 Kg per square mm to 500 Kg per sqmm on outlet of transfer pumps including 15mm dia Gate valve complete all as specified and as directed.
M&L Providing precast PCC (1:2:4) Type B-1 solid block of size 200 x 100 x 100mm as in continuous road edging with width equal to the length of PCC block laid dry on end vertically including excavation and earth work complete all as specified and directed.
Fixing only heater water storage type electric geyser 50 Ltr capacity including fixing arrangement and including supply and fix PVC connection pipe of suitable length for hot and cold water complete all as specified and directed. (Note : Geyser 50 Ltr will be issued under Sch 'B' as free for fixing).
Supply only refrigerator electric driven (single phase) capacity 263 Ltr. Make: Blue Star / Voltas.
Sub total
DISMANTLING / DEMOLITION (Sch 'A' Part-XIV)
Lump sum price worked out by the Contractor for “(DISMANTLING / DEMOLITION)” as listed in Schedule ‘A’ Part-XIV. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 14,643.44 inserted by the MES in Schedule ‘A’ Part-XIV.
M/S P.K. THUNGON BUILDERS
M/S TSERING DHONDUP
H P CONSTRUCTIONS
M/s Singh enterprises
AIEN MEREN ENTERPRISES
B D Raizada Projects Pvt Ltd
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .