Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹22.4 LAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | 2₹23.8 L+₹33,565 (1.43%)Rejected-Finance 274 A 5TH LANE NISHATGANJ LUCKNOW UP PIN 226007 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226007 | 2 | Rejected-Finance Not L1 | |
| 3 | 3₹24.4 L+₹90,055 (3.83%)Rejected-Finance NEAR AVON PUBLIC SCHOOL DABHANW POST DANDI NAINI PRAYAGRAJ 211008 | PRAYAGRAJ | PRAYAGRAJ | UTTAR PRADESH | 211008 | 3 | Rejected-Finance Not L1 | |
| 4 | 4₹24.6 L+₹1.1 L (4.89%)Rejected-Finance SA 15 144 S 1 CHANDAN HERITAGE HAVELIA CHAURAHA SARNATH VARANASI U P 221007 | VARANASI | VARANASI | UTTAR PRADESH | 221007 | 4 | Rejected-Finance Not L1 | |
| 5 | 5₹25.9 L+₹2.4 L (10.1%)Rejected-Finance 361 D SHAKTI NAGAR NEAR KHAN DAIRY INDIRA NAGAR LUCKNOW 226016 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226016 | 5 | Rejected-Finance Not L1 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
11 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE LUCKNOW
HQ CWE Lucknow, 229 MG Road, Lucknow Cantt, Lucknow-226002
REPAIR /MAINT OF STREET LIGHTS AND CONNECTED ITEMS AT AMC C ANDC AND CONNECTED AREA UNDER AGE E/M EXT (ELECT) UNDER GE E/M LUCKNOW
2023_MES_633794_1
CWE/LKO/EM/T-81 OF 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Lucknow
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE EM Lucknow
₹60,000
Yes
21 Feb 2024
21 Dec 2023
18 Jan 2024
21 Dec 2023
11 Jan 2024
4 Jan 2024
21 Dec 2023 - 4 Jan 2024
Amount
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft/loose soil for laying / taking up/ taking down of cables and getting out and levelling of bottom suface to required level all as specified and directed by Engineer- in- Charge.
Returning filling in,. Including spreading, levelling,. Watering and well ramming soil in layers not exceeding 25 cm thick all as specified and directed.
Removing excavated material (ie soil) from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point all as specified and directed by Engineer-in-Charge.
Sand cushioning for protection of cable complete all as specified and as directed by Engineer-in-Charge. Note :- Local approved tibba dry sand after removal of vegetations; grass and other deleterious substances shall be used for sand cushioning.
M&L laying well burnt old size bricks, sub class "B" bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection complete all as specified & directed by Engr-in-Charge.
All as per srl item No 5 here-in-before but using old bricks obtained under srl item No 1 here in before.
M&L for demolition /cutting of road/ path/hardstading/ concrete in floor, etc for laying of cable complete all as directed at site by Engr-in-charge
Material and labour for PCC 1:2:4 type B-2 using 40 mm graded stone aggregates for filling of cutting of roads/path/hardstanding etc complete all as specified and as directed by Engineer-in-Charge.
Boring of hole under road/pavement/hard standing or any other situation by manual means and suitable for passing of GI pipe 40 to 80 mm bore and making good both ends all specified and directed
S&F in replacement GI Pipe (light grade) with necessary accessories/ fittings for cable protections/pole for crossing of culverts/nallah of 50 mm bore
All as per item No 10 above but 40 mm bore
Material & Laying, jointing and testing in replacement of LT under ground electric power cable crossed linked polyethylene ( XLPE) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of size 10 sqmm cross sectional area, 2 core ,complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc. with and including MS Clamps, nuts , bolts, washers complete all as specified and directed. Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles/ block and pipe shall be measured and paid separately under appropriate items.
All as per item No 12 above but of size 16 Sqmm 2 core
All as per item No 12 above but of size 16 Sqmm 4 core
All as per item No 12 above but of size 25 Sqmm 4 core
Earthing in replacement complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by mean of GI wire 4 mm dia by means of bolts, nuts check nuts and washers of GI or steel and connecting to earthing test point, main switch board, testing on completion including PCC cover and frame, PCC (1:3:6) type C-2 as in earthing pit, MS funnel with wire mesh GI pipe 20 mm dia light grade for watering and GI pipe 15 mm dia light grade for the protection of GI wire from earth pit to earth point complete including necessary excavation and earth work in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance n.exc 50 m all as specified as shown in electrical plate No 5 SSR Part-I. PCC chamber shall be constructed at least one metre away from the earth pit and GI pipe fittings for watering shall be provided up to chamber and cost of the same is deemed to be included in the rate of earthing. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Supply & Fixing in replacement twin core, 6 sqmm nominal cross sectional area multistranded aluminium conductor cable, over all PVC sheathed, 1100 Volts grade heavy duty cable PVC insulated and PVC sheathed complete all as specified.
Supply & Fixing in replacement twin core, 10 sqmm nominal cross sectional area multistranded aluminium conductor cable, over all PVC sheathed, 1100 Volts grade heavy duty cable PVC insulated and PVC sheathed complete all as specified.
Supply drawing, connecting and testing in replacement 3 core, 1.5 Sqmm PVC insulated and PVC round sheathed` copper conductor (flexible ) industurial cable, 1100 Volts conforming to IS 694 in steel tubular poles from Junction box to street light fitting including providing suitable copper lugs all as specified and directed by Engr-in-charge.
S&F in replacement wheather proof pole mounting PVC junction box, base and door of junction box made out of SMC having outside dimention 333x233x120mm, inside dimention 300x200x105mm , single door front openable provided with hinged cover and locking arrangements with 4 Nos aluminium bas bar 63 Amps, mounted on porcelin insulator including M&L for MCB SP 10 Amp -1No, fixed on box in Din rail complete with electrical connection fixed to pole with suitable size FI clamp nut bolts and washer including embossing/painting of danger notice of size not less than 10cm x 7.5cm with letters, figures and conventional skull and bones in signal red colour on front face of junction box body Complete all as directed by Engr-in-Charge
Supply & fixing in replacement GI brackets made of 40 mm nominal bore GI pipe medium grade of required length not less than 1.5 M long, mounting brackets made out of Mild steel FI 40x6 mm of required shape ( two Nos) duly fitted with Mild steel nuts, bolts and washers and painting with two coats of synthetic enamelled paint over one coat of red oxide Zn chrome primer and fixed to pole / walls etc complete all as specified & directed by Engr-in-Charge.
Preparation of old painted surfaces and painting of LT steel tubular pole 9 mtrs long from bottom to top with aluminium paint and painting to bottam up to 1.5 mtr height from top of PCC coping with synthetic enamel paint 2 coats in black and Yellow alternate strip including numbering in 8 cm height of number with white paint both paint aluminium /synthetic duly approved by engineer –in-Charge and complete all as directed and specified .
Cleaning the existing painted surface of LT panel by scrapping, making good distrubed surfaces by applying putties on uneven surface to make it even and M&L for spray painting to LT panel of any size with two coat of synthetic enamel paint with desired colour over one coat of red oxide primer complete all as specified and directed.
Material and labour disconnecting faulty /burnt end or portion of cable from LT panel/LT pole /main switch/changeover etc by removing the cable from loop including necessary excavation & earth work , cleaning the surface area not less than 1 mtr surrounding the panel/pole , provision of suitable size of thimble, LT tap , relaying and reconnecting the cable by removing faulty/burnt portion of cable and preparing fresh terminals for 16 Sqmm 3.5/4 core to 240 Sqmm 3.5 core of LT cable to LT Panel/pole/main switch/changeover complete all as directed.
Supply and errection in replacement 07 mtr continuously tapered hot dip galvanised Octagonal cross sectional pole with single dipping method having bottom 130 mm A/F and top 70 mm A/F 3 mm thick confirming to ASTM A 572 Gr with yield 450 mpa cut and folded to form an octagonal section and welded in accordance with AWS for wind loading as per IS 875 part 3 1987.Poles shall be provided with base plate of size 225x225x12 mm which shall be free from any lamination or incursion with no cutting or welding on the pole after hot dip galvanising with single arm 1000 mm long bracket tilted to 150 degree from horizontal toward vertices suitable for mounting on the octagonal pole, of company recommendation and one no TPN Connecton 3 phase 4 wire 100 Amps, and one number MCB SP 6 Amps. A triangular flat MS plat of 6mm thick duly coated with GI shall be welded between cap of the octagonal pole and bracket. Welding work shall be done 250mm on bracket and 150 mm on pole's cap including all RCC work type (1:2:4) type B-1 including 04 Nos foundation nut bolt and plate as per pole manufacturer's drawing and earth work all as per requirement complete all as specified and directed. Note Cost of construction of RCC foundation including construction material, necessary earth work and excavaton as per manufacturer design for above pole complete all as required at site and as directed by Engr-in-charge are deemed to be included in the quoted rate.
Supply & fixing in replacement automatic street light timer panel 5 KW switch using Infrared Sensor based for automatic switching of street lights based on LUX level of natural light. Required illuminance for switching ON is < 30 Lux and for switching OFF > 10 Lux level. The sensor (nature switch) alongwith suitable power contactors, Input (supply) MCB and output (load) MCB(s), support terminals should be enclosed in pole/ wall mountable enclosure made of rust proof, electric shock proof, termite proof and FR graded SMC junction box conforming to IP-54 degree of protection including mounting bracket, cable glands, openable doors with lock complete all as specified & directed by Engr-in-Charge.
Supplying, transporting, erecting in replacement Steel tubular swaged poles type 410 SP-31 ( 9.0 metres long) complete with cast iron base plate, finial, taper plug, bolts, nuts and screws as specified, including necessary excavation and earth work , PCC 1:4:8 type D2 in foundations below pole, PCC 1:3:6 type C2 around poles and PCC 1:3:6 type C1 as in plinth block , disposal of surplus soil to a distance not exceeding 50 m and depositing where directed, the exposed surface of steel tubular poles shall be painted with two coat of aluminum paint over a coat of red oxide, embaded portion of the pole shall be painted with one coat of bituminous paint. 05 Nos black and Yellow alternate strip with two coat of synthetic enamel paint shall be painted up to the the height of 1.5 M from copping of the pole including numbering on pole in black colour synthetic enamel paint complete all as specified and directed.
Supplying and fixing in replacement 3 pole power contractor AC 3 rating 40 Amp, 240 Volt AC complete all as specified and directed by Engr-in charge
Supplying and fixing in replacement 3 pole power contractor AC 3 rating 70 Amp, 240 Volt AC complete complete all as specified and directed by Engr-in charge
Supplying and fixing in replacement Astronomical Digital Timer Switch 240 V AC complete all as specified and directed by Engr-in charge
Supply and fixing in replacement 60 W LED street light fitting with mandatory driver set having pressure die cast aluminium housing with high efficiency LEDs as lighting source and lens embaded PC cover /IP lens, street light should have IP 66 protection, impact resistance of IK 07 , Lumen efficiency of LED not less than 110 lumen per watt system efficency ,power factor >0.95, THD<10% at Full load CRI> 70% ,street light should have built in potted electronic LED driver with , lower THD, open circuit protection , over voltage protection , surge voltage protection , and provided with company LOGO ingraved on housing of the street light complete including taking down of old UNSV fittings all as specified and directed by Engr -in-Charge. Note :-The contractor should take approval of techincal specification of luminaries and driver from department before procurement .
Supply and fixing in replacement of 200 W LED flood fitting having epoxy powder coated die cast aluminium housing ADC12 in grey finish with elegantly designed heat sink for efficient thermal management , sturdiness & excellent corrosion resistant. PG9 gland is used for cable entry and provision for loopin -loopout , PC lens/IP lens with narrow /wide beam distribution and toughened glass fixed to housing with screws , flood light should have IP 66 protection and impact resistance of IK 07 , Lumen efficiency of LED not less than 120 lumen per watt system efficency ,power factor >0.95, THD<10% at Full load CRI> 70% ,flood light should have built in potted electronic LED driver with , lower THD, open circuit protection , over voltage protection , surge voltage protection , and provided with company LOGO ingraved on housing of the flood light complete including taking down of old UNSV fittings all as specified and directed by Engr -in-Charge. Note :-The contractor should take approval of techincal specification of luminaries and driver from department before procurement .
All as per item Ser No 32 above but 120 Watt & Lumen efficiency of LED not less than 110 lumen per watt system efficiency
All as per item Ser No 32 above but 100 Watt & Lumen efficiency of LED not less than 110 lumen per watt system efficiency
All as per item Ser No 32 above but 50 Watt & Lumen efficiency of LED not less than 100 lumen per watt system efficiency
Supply & fixing in replacement electronic LED Driver suitable for LED flood light 50 Watt to 100 Watt of existing make and model.
Supply & fixing in replacement electronic LED Driver suitable for LED flood light 120 Watt to 150 Watt of existing make and model.
Supply & fixing in replacement electronic LED Driver suitable for LED flood light 200 Watt of existing make and model.
Supply & fixing in replacement electronic LED Driver suitable for LED Street light fittings 45 Watt to 70 Watt of existing make and model.
Supply & fixing in replacement electronic LED Driver suitable for LED Street light fittings 90 Watt to 100 Watt of existing make and model.
M/S S.B. Singh and Sons
NEXT POWER ENTERPRISES
M/s A.K Construction
Eco Creations
Prime power system
OM NAMAH SHIVAY ENTERPRISES
M/S SHIVA CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .