Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.6 LAccepted-AOC HOUSE NO 108 WARD NO 08 SHAKTI NAGAR DHAR ROAD UDHAMPUR UDHAMPUR JAMMU KASHMIR 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹12.7 L+₹15,455 (1.23%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹12.8 L+₹16,025 (1.27%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹12.8 L+₹22,290 (1.77%)Rejected-Finance 135 CHAKRANA TIWARI CHAKA NAINI PRAYAGRAJ 211008 UTTAR PRADESH | PRAYAGRAJ | UTTAR PRADESH | 211008 | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹15.6 L
EMD Value
₹31,300
Closing Date
10 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sh A K Dubey, IDSE , SE CWE
Military Engineer Services, Commander Works Engineer, Udhampur, PO - Garhi, Udhampur-182121
REPAIR / MAINT TO VARIOUS ACCESSORIES OF 33 KV SUB STN AT CHETRI AND KALIMATA UNDER GE(U) UDHAMPUR
2022_MES_538487_1
CWE/U(U)-48/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Udhampur
AS PER TENDER
7 documents required · 7 mandatory
₹500
GE (U) Udhampur
₹31,300
Yes
3 Oct 2022
15 Jul 2022
12 Aug 2022
15 Jul 2022
10 Aug 2022
28 Jul 2022
Amount
Taking down the 33 KV circuit breaker from the system decarbenising the complete circuit system with CTC( carbon) Tetra chlride) .Checking the complete moving/fixed contracts for any loose & retighney. The bus chamber should be inspected for loose joints.
(a) Panel side: 33 KV panel side the circuit sprouts /Bus sprouts has to be checked. Proper closing of sprouts to be checked. Any mechanical imblance is found to be rectified. Proper DC system has to be checked for functioning indication system & tripping & closing system has to be prop checked and mentioned.
(b) Breaker side: The trowlley to be checked for mechanical fitment inside the chamber,Proper checking of tripping/closing system application of greasing to complete mechanism. Minor repair related to mechanism to be rectified . Are chector. SF-6 punty test to be done on interruptors to maintain dielectric properly of are quenching in breakers.
(c) Relay calibration : Relay calibration shall be done by primary injector kit . Necessary plug setting and injector shall be done ( wind) load.
Following routes test are to be performed on breaker a) SF-6 gas leakage test. b) Tightness test. c) Design/Visuel test. d) Mechanical operaton test. e)Measurement of resistance of main circuit(or) contract resistant test. f) Dielectric test on auxiliary circut & control circut. g) Power frequency over voltage with starter test.
Servicing, repairing and overhauling of 33 KV isolator including cleaning of complete moving and fixed contracts oiling/ greasing operating mechanismtightening connections and replacement of unserviceable parts including reassembling the isolator after complete repair, routine and periodical testing complete all as specified and directed.
S&F in repair post insulator of 33 KV air break switch isolator rotating type complete all as specified and directed.
S&F in repair terminal pad of 33 KV air break switch isolator rotating type complete all as specified and directed.
S&F in repair arching horn of 33 KV air break switch isolator rotating type complete all as specified and directed.
S&F in repair connector of 33 KV air break switch isolator rotating type complete all as specified and directed.
S&F in repair operating down pipe of 33 KV air break switch isolator rotating type complete all as specified and directed.
S&F in repair operating box of 33 KV air break switch isolator rotating type complete all as specified and directed.
S&F in repair fixed contact assembly of 33 KV air break switch isolator rotating type complete all as specified and directed.
S&F in repair moving contact assembly of 33 KV air break switch isolator rotating type complete all as specified and directed.
Supplying and fixing in repair/replacement of HT out door type Gang operated rotating type, triplepole,mechanically operated Air Break Switch Volts rating, 400 Amp capacity, horizontal mounting, double break, mounted on insulation and steel frame, GI operating rod of suitable length to be worked from ground level. including Taking down complete as specified and as directed.
Maintenance of 33 KV yard comprising of painting the yard with one coat of synthetic enamel paint as required and writing the designation of equipments in english albhabets/ letters as specified & as directed by Engr-in-charge and mainly the following:- (i) Transformer 33/11 KV of capacity 6.3 MVA-01 No (ii) Structure - 01 No (iii) Duct cover - 30 Mtrs OLTC boxes- 01 No Mast conductor-
M&L for complete draining out the transformer oil from radiators after closing the inlet valve from main body of 6.3 MVA power transformer including filling transformer oil of good quality having not less than 70 KV dielectric strength, having low viscosity all as specified and directed by Engr-in-Charge. Make: Savita/Power oil as per IS 335 of 1983 all as specified and testing of Transformer after filling new oil complete upto 10 Hrs minimum as per entire satisfaciton of Engr-in-Charge.
Labour only for dehydration & filtration of transformer oil in existing transformers installed at site with portable plant to improve the dielectric strength 70 KV including testing of dielectric strength after dehydration & filteration at site. Note:- a) Pre-heated oil shall be topped up as required at site before the process; oil will be measured and paid seperately under respective item. b) Qualified technician for filters of transformer shall be deputed. c) Transforaton of filhates mechine from 132 KV sub station to 33 KV S/S is demmed to be including of rate quoted.
Supply & Fix in replacement silica gel breathers assembly filled complete suitable for transformer cap 6.3 MVA (As per Sample) complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of current transformer CT Ratio150/75/1-1A of 33 KV, 15VA, Core 1, class-0.5, STC 20 KA for 1 sec complete all as specified and directed by Engr-in-charge. Make:-AREVA, ABB & L&T
Supply & fixing testing and commissioning feeder protection and control relay REF615,50,51 N, 46,49,95 measurement for 3I,I0,4DI+6DO, One Rear RJ 45 port for IEC-61850 protocol, draw out type with CT shorting feature. Graphical LCD display, uaux48-250VDC/100-240 VAC all as specied and directed by Engr-in-charge. Make:- ABB & L&T, Simens, Schneider or equqlent
S&F of Chequr plates/GI sheet/ cross arms of MS fabricated complete with all accessories viz nut, bolts, washer etc. Including Taking down complete all as specified and directed by Engineer-in-Charge.
Supply and fixing pin insulator porcelain viterous brown including 01 galvanized M.S.spindle, two galvanised iron washers and one gal. iron nut suitable for HT 33000 Volts complete all as specified and directed by Engineer-in-Charge.
Supply, laying, commissioning and testing XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable (Heavy Duty) with aluminium conductor 33000 volts grade cross sectional area 185 sq mm, 3 core including taking down of U/S Cable complete all as specified and directed by Engineer-in-Charge
M&L for Cable jointing kit for 33 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm complete, all as specified and directed by Engineer-in-Charge.
M&L for Cable jointing kit for 33 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 sqmm to 240 sqmm complete, all as specified and directed by Engineer-in-Charge.
M&L for Cable jointing kit for 33 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 sqmm 240 Sqmm complete, all as specified and directed by Engineer-in-Charge.
M&L for Separator sheet sheet for 33 KV Breaker complete with material and accessories complete, all as specified and directed by Engineer-in-Charge.
M&L for Space heat 36 watt for 33 KV breaker complete with material and accessories complete, all as specified and directed by Engineer-in-Charge.
M&L for Bus bar suitable Sleeves for 33 KV breaker complete with material and accessories complete, all as specified and directed by Engineer-in-Charge.
M&L for HT insulation empire tape yellow colour of width 25mm 10 mtr long ISI marked complete all as specified and directed.
Supply and fixing in replacement lightning arresters for non linear resistance type for 33 KV normal discharge count 5 Amps and high current impulse withstand 65 Kilo Amps conforming to IS-3070 Part-I for OH line including bracket, clamps, nuts and washers. Including Taking down complete all as specified and directed by Engineer -in-Charge.
Cutting/ trimming of tree branches not exc 10cm girth touching/approaching the HT overhead lines upto 3 metre width on each side with hacksaw/axe to clear the HT line including disposal of trimmed branches 100 Metre away inside the cantonment area & clearing site complete all as specified and directed by Engr-in-Charge.
M&L for Removing of existing stone aggregates from 33 KV sub station upto 15cm deep including unwanted grass and refilling the same after complete cleaing ( 20 Sqm per day) entire satisfaction of Engr-in-charge complete all as specified and directed.
Supply and spreading stone aggregates of size 20mm evenly at outdoor 33/11 KV sub stations after removing uprooting of tiny trees, bushes, beeds, grass, elephant grass, removing poly bags, brick bats, stone pebbles and other debris etc complete all as specified and directed by Engr-in-charge.
M/S Builders Indias
proach associates
vijay builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .