Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.0 LAccepted-AOC SHOP NO 259 LOHOGAON ROAD KALWAD KHANDVE NAGAR PUNE 411032 | PUNE | MAHARASHTRA | 411032 | L1 | Accepted-AOC AOC | |
| 2 | L2₹44.3 L+₹3.3 L (7.93%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹46.3 L+₹5.2 L (12.8%)Rejected-Finance NO 439 AHIV ADAN 11ND FLOOR 2RD STAGE INDIRA NAGAR BANGALORE 560 075 | BENGALURU URBAN | KARNATAKA | 560075 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹47.4 L+₹6.4 L (15.6%)Rejected-Finance 101 1ST FLOOR JASOL RESIDENCY 14TH CROSS KANAKANAGAR R T NAGAR POST BANGALORE 560032 | BANGALORE | BANGALORE | KARNATAKA | 560032 | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹49.0 L+₹7.9 L (19.4%)Rejected-Finance SITE NO 29 30 1ST CROSS NAGAPPA REDDY LAYOUT KAGGADASPURA CV RAMAN NAGAR BANGALORE 560093 | BENGALURU URBAN | KARNATAKA | 560093 | L5 | Rejected-Finance Not Lowest |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
5 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NORTH BANGALORE
GARRISON ENGINEER NORTH BANGALORE T 64 MEANEE LINESMEG AND CENTRE BANGALORE 560042
REPAIRS REPLACEMENT OF EXTERNAL SERVICES ELECTRIFICATION SUPPLY DISTRIBUTION SYSTEMS AND CONNECTED ALLIED WORKS AT MEG N CENTRE FMME TOC TOP ASSAYE LINE OFFRS MESS OLD TB III AND NEW TB III AND ENHANCEMENT OF CMD FROM 150 KVA TO 200 KVA FOR RR NO
2023_MES_626217_1
8430
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
BANGALORE
Class D Category b(i)
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER NORTH BANGALORE
₹88,000
Yes
15 Jan 2024
1 Nov 2023
12 Dec 2023
1 Nov 2023
5 Dec 2023
21 Nov 2023
1 Nov 2023 - 21 Nov 2023
Amount
Excavation in trenches in hard/dense soil not exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying of cables/errection of pole etc complete all as specified and as directed.
Excavation in trenches in hard/dense soil not less than 1.5 mtr deep and not exc 3 mtr in deep for pole foundation etc complete all as specified and as directed.
Returning, filling in trenches incl spreading leveling watering and well ramming in layers with hard/dense soil not exc 25 cm thick in each layer complete as specified and as directed
Removing excavated soil to a distance not exc 1.5 mtr above the starting point complete all as specified and as directed
M&L for sand cushioning with a layer of M sand 23 cm thick under and above the cable complete all as specified and as directed Note:- Punned thickness will be measured for payment.
S & L sub class burnt bricks for cable protection complete as specified as directed
Supply and laying cable XLPE insulated screened PVC bedded galvanised steel strip or wire armored, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor connected with suitable legs including neccessary roadcrossing if applicable including taking out the existing unserviceable cable for following size :- 2 C x 10 Sqmm Note: Earthwork, sand cushioning and cable cover will be measured and paid separately.
All as per item No 7 above but for 4 C x 10 Sqmm
All as per item No 7 above but for 4 C x 16 Sqmm
All as per item No 7 above but for 3.5 C x 25 Sqmm
All as per item No 7 above but for 3.5 C x 35 Sqmm
All as per item No 7 above but for 3.5 C x 50 Sqmm
All as per item No 7 above but for 3.5 C x 70 Sqmm
All as per item No 7 above but for 3.5 C x 95 Sqmm
All as per item No 7 above but for 3.5 C x 120 Sqmm
M&L MS work of any type for cross arms, supports, bracing MS clamps etc made out of MS channel/angle iron/flat iron/ round section of any size and bolt nuts and washer incl painting with two costs of aluminium paint over a coat of red oxide including dismantling and taking down old unserviceable work complete all as specified and as directed
M&L of pin type porcelain, vitreous white or brown insulator incl one galvanized mild steel spindle two galvanized iron washer and galvanized iron nut 100 mm height and 65mm dia for 1100 volts grade fixed in repairs complete all as specified and as directed
M & L shackle type porcelain, vitreous white or brown insulator incl one galvanized mild steel spindle two galvanized iron washer and galvanized iron nut 75 mm height and 90mm dia for 1100 volts grade fixed in repairs complete all as specified and as directed
M&L for GI tubing light grade 40mm dia with all accessories for cable protection fixed on poles / bldgs / road and laid in trenches incl necessary MS clamps, bolts and nuts etc all as specified and as directed.
M&L for GI tubing light grade 50mm dia with all accessories for cable protection fixed on poles / bldgs / road and laid in trenches incl necessary MS clamps, bolts and nuts etc all as specified and as directed.
M&L for GI tubing light grade 80mm dia with all accessories for cable protection fixed on poles/bldgs/road and laid in trenches incl necessary MS clamps, bolts and nuts etc all as specified and as directed.
M & L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.5 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to and incl galvanized iron strip 25x4mm as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I 1991 and as specified or indicated and testing on completion incl earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways incl funnel with watering pipe wire mesh and lugs, incl test point complete all as specified and as directed
M & L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to galvanized earth lead wire 4 mm dia as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I 2010 and as specified or indicated and testing on completion incl earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways incl funnel with watering pipe wire mesh and lugs, incl test point complete all as specified and as directed.
M & L for tightening of ACSR (Aluminium conductor steel reinforced) conductor of any size between two poles 06 runs of conductor incl binding wire of appropriate size complete incl clearing of path and branch cutting etc all as specified and as directed
S & F MCCBs 4 pole 415 Volts 50HZ incl complete connections with incoming cable and out going cable with suitable thimbles and crimping the thimbles with crimping tools insulating the naked portion with insulation tape fixed in repairs. MCCB 100 Amps,16 KA with adjustable Thermal setting
All as per item No 25 above but for MCCB 200 Amps 36 KA with adjustable Thermal setting.
All as per item No 25 above but for MCCB 250 Amps 36 KA with adjustable Thermal setting .
All as per item No 25 above but for MCCB 315 Amps 36 KA with adjustable Thermal setting .
All as per item No 25 above but for MCCB 63 Amps, 25 KA with adjustable Thermal setting
M & L for replacement of LT 2 line separator 230 volts 50 Hz all as specified as directed
M & L for replacement of LT 4 line separator 415 volts 50 Hz all as specified as directed
M&L for taking down old cable joint and Supply and fix new cable jointing kit for 1.1KV grade cable for straight through joint complete with jointing material and accessories suitable for 3.5 core / 4core XLPE armoured aluminium conductor cable for following sizes:- 3.5 C x 25 to 35 Sqmm
All as per item No 32 above but for 3.5 C x 50 to 120 Sqmm
M&L for painting of steel tubular/PCC poles of any height and type, incl security light mounting brackets with one coat of aluminium paint/two coat of cement base paint incluing painting black and yellow strip or as ordered by engineer-in-charge on poles up to 1.5 mtr high above coping level and numbering of pole complete all specified and as directed.
Dismantling of ACSR (Aluminium conductor steel reinforced) conductors
M&L of ACSR (Aluminium conductor steel reinforced) conductor of any size on poles incl binding wire of appropriate size complete incl clearing of path and branch cutting etc all as specified and as directed
Refixing of ACSR conductor connected with new existing wire tightening to insulator incl line clearance by pruning of tree branch approx 1 m apart from conductor tightening side.
S&F Stay assembly complete with all accessories as shown in elect plate No 1 of SSR Part-I consisting of stay rod 20mm dia 1.8 mtr long,size of stay plate 230 x 230 x 6 mm with nuts,bolts,insulator stay clamps etc. complete all as shown on drawing and as directed Note:- Excavation and stay wire shall be measured and paid separately
M&L for galvanized iron stay strand 7/4 mm complete all as specified and as directed
Dismantling the damaged unservicable pole of any type.
Supply and errect steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410SP-31, 9 mtr long. Note: Earthwork and PCC will be measured and paid separately.
M&L for PCC 1:3:6 type C1 with 20mm graded stone aggregate for coping of pole,filling and mass concrete of pole, make good to road surface, hard standing etc incl necessary form work all as specified and as directed
M&L for PCC 1:4:8 type D2 with 40mm graded stone aggregate in foundation of poles all as specified and as directed
M&L for outdoor type, double door sheet metal enclosure/Junction box of size 80x80x30 cm with aluminium bus bar 250 Amps for 3 phase & neutral including MCCB 4 pole 415 volts 160 Amps 36 KA including removing old unserviceable junction box complete all as specified and as directed
Supply and fix Timeline distribution board 32 A 3 pole / 230V analog time switch including complete accessories relay contactor, timer fixed in repairs etc, all as specified and as directed. Make:- Indoasian Cat No. TL032AB0 or its equivalent in L&T / Sirmens / BAJAJ.
M&L for finding cable fault in LT cables any sizes complete all as specified and as directed
Supply & Fix on pole/ wall etc GI pipe bracket made of 40mm bore light grade GI pipe1.5 mtr long suitably bent to shape and fixed on wall/ pole for fixing street light fitting with 2 Nos suitable MS clamps of size 25 x 3 mm size incluiding bolts, nuts, washers all as specified and as directed fixed in repairs.
Supply and fixing moulded (FRP) junction box with IP 65 protection of size 300x200x80mm with 32 Amp 4 way heavy duty terminal block with 6 Amp MCB SP and two number of cable entry gland of standard size with suitable MS bracket to fix with pole fixed in repairs complete all as directed
Supply and fixing 60 W LED street light fitting with pressure die cast housing along with prismatic polycarbonate modular secondary lens optics with IP 66 ingress protection and impact resistance of IK 08. 4kV inbuilt and 10 kV external surge protection with top opening driver cover for easy maintenance .including taking down old unserviceable street light fittings from pole. Make:- Bajaj, Cat No.:- ENXT P 72 L WH CR PC SD or its equivalent in CG / Philips / Havells
Supply and fixing 90 W LED street light fitting with pressure die cast housing and toughened glass and individual LEDs with secondary lens optics with IP 66 ingress protection and impact resistance of IK 07. 5kV inbuilt and 10 kV external surge protection with top opening driver cover for easy maintenance .including taking down old unserviceable street light fittings from pole. Make:- Bajaj, Cat No.:- BRTFG 90W LED CR or its equivalent in CG / Philips / Havells
S&F submain wiring of 2 runs of PVC insulated 2.5 sqmm single core multistranded copper conductor cable and one run of 2.5 sqmm copper wire as earth continuity conductor drawn through and incl rigid non metalic conduit 20 mm external dia fixed on poles & connecting up all as specified and as directed including taking down old unserviceable submain complete. Note: Two runs of cable and one run of earth wire and one run of conduit shall be measured as one length.
Supply & fix on load Change over switch 4 pole in sheet metal enclosure compact design rating 63 Amps suitable for isolation and prevent leakage current/ flush over between phases, handle lock feature in off position with three padlocks fixed in repairs. Make :- INDOASIAN Cat No. ITAS0063 or Havells / L&T / Standard.
Supply & fix on load Change over switch 4 pole in sheet metal enclosure compact design rating 100 Amps suitable for isolation and prevent leakage current/ flush over between phases, handle lock feature in off position with three padlocks fixed in repairs. Make :- INDOASIAN Cat No.ICAS0100 or Havells/L&T/Standard.
Dismantling and taking down old unserviceable CFL type street light fittings from Pole, removing the unserviceable CFL and replacement with new LED bulb 40 watt with suitable size holder and refixing in the existing/new location all as directed at site by Engineer-in-charge.
Dismantling and taking out the LED street light fittings any make from Pole and removing the burned out /unserviceable LED driver 25 W to 60W and replacement of new drive to make the fitting serviceable and refixing the existing/new location all as directed at site Engineer-in-charge.
Dismantling and taking out the LED street light fittings any make from Pole and removing the burned out /unserviceable LED driver 90 W and replacement of new drive to make the fitting serviceable and refixing the existing/new location all as directed at site Engineer-in-charge.
Dismantling and taking out the flood light from high mast pole and removing the burned out/unserviceable LED driver 200 W and replacement of new drive to make the fitting serviceable and refixing the existing/new location all as directed at site Engineer-in-charge.
Supply & Fix 200W LED flood light luminaries with innovative die-cast aluminium flood light with highly efficient LEDs as light source, suitable for highmast lighting with complete accessories including taking down old unserviceable flood lights from high mast pole all as specified and as directed. Make:- HAVELLS, Code No. : JETAVALOURFL200WLED757PINTNBLTG or Equalvalent in Phillips / CG / Bajaj
M&L for painting of outdoor type Feeder pillar panel upto the size of 1100 x 450 x 1200 mm (approx), incl replacement of door hinges with new one and applying one coat of smoke grey colour paint including base angle with black paint complete or as directed by Engineer-in-charge complete all specified and as directed.
M&L for painting of outdoor type LT panel upto the size of 2500 x 600 x 3000 mm (approx), incl replacement of door hinges with new one and applying one coat of smoke grey colour paint including base angle with black paint complete or as directed by Engineer-in-charge complete all specified and as directed.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 63 mm dia bore suitable for 0.4 mpa working pressure. Note: Quoted rate is inclusive of obtaining permission from load bodies if required.
Supply, testing and commissioning in replacement of weather and vermin proof LT feeder pillar box factory fabricated outdoor cubical/kiosk type CPRI approved and confirming to IS 5036 totally enclosed made out of 3 mm thick sheet metal enclosure with angle iron frame of M.S. angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel centre opening front and rear opening doors (covers) with handles, each control switch to be fixed in each compartment with hinged door, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly with powder coated, painted one coat of red oxide primer and two coats of synthetic enamel paint of gray or any other approved Contd/---63
M&L in replacement of outdoor type Lt panel front opening door upto the size of 2500 x 3000 mm (approx), incl replacement of door hinges with new one and duly with powder coated, painted one coat of red oxide primer and two coats of synthetic enamel paint of smoke grey colour as directed by Engineer-in-charge complete all specified and as directed.
Cutting of road crossing / PCC hard standing for laying of pipe/ cable including making good the existing surface with same finish ( PCC 1;3;6 type C2 40 mm graded stone aggregate / Bitumen) to match the original finish all as specified and as directed.
(a) S&F Grounding Materials for RMUs and Transformers with good quality salt for grounding purposes packed in 50 kg gunny bags complete all as specified - 02 Bags (b) S&F Grounding Materials for RMUs and Transformers with good quality well burnt charcoal for grounding purposes packed in non returnable containers - 02 Nos (c) S&F Grounding Materials for RMU's and Transformers : GI Grounding Pipe, B-Class, 40 mm dia, 2.5 mtrs long, 2.9 mm thick with bolts nuts, GI strips and washers complete -2 Nos (d) S&F Three phase 4 wire static meter (CT, PT operated) 3 X 63.5 V, 5 Phase or 1 Amps class 0.2 s with RS-485 and ABT features - 01 Each (e) S&F 11 KV metering cubicle of different CT ratio, both side cable entry type with 3CT and 3 PTs with transparent cover TTB, with 30 X 8 mm Cu bus bars, Modem and 2 Nos of meters for 3 Ph 4 Wire Metering without load break Switch (HT Metering Box Fabricated out of 3 mm MS Sheet duly epoxy powder coated) as per revised Specification (Dwg No BESCOM/GM/QS&S/ dated 24.11.2018 complete all as specified - 1 Each (f) M&L for fixing of grounding connection complete all as directed - 2 Each Contd/---66
Contd/--65 (g) Erection of HT metering cubicle on platform (Releasing 2 CT and 2 PT HT Metering Cubicle) (1+0.90%)- 1.9 Each (h) M&L construction of platform with size stone, cement concrete for erection of 500 KVA Transformer/Heavy Equipment. Construction of platform (1.5 X1.5 X 2) mtr in size stone, for erection of transformers/Heavy equipment including all materials, labour. Excavation of (1.5 X1.5X1) mt pit for foundation laid in 1 cm thick layers, well compacted curing etc, complete providing and construction of stone masonary 0.9 m below ground level and 1.2 m above ground level neatly hammer dressed in cement mortar 1:3 after racking joint and nicely lining curing etc, plastering the concrete surfaces in cement mortar 1:4 including smooth rendering curing etc curing at every stages completely - 01 Each Note: The quoted rates deemed to include complete testing and commissioning of HT Metering Cuibcle by BESCOM MRT team, submission of revised agreeement of HT Connection after enhancement and all documentation with BESCOM office by the contractor.
RAMSON TRADERS
Shiva Shakthi Electrical Enterprises
Vasavi Electricals
Aavani BUILDERS AND CONTRACTORS
GS TRADERS
JAIHIND ENTERPRISES
M S K CONSTRUCTION
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .