Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.9 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹5.3 L+₹9,898.68 (1.92%)Rejected-AOC E 73 FF GALI NO 17B SADH NAGAR PALAM COLONY NEW DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | L2 | Rejected-AOC Other than lowest bidder | |
| 3 | L3₹5.4 L+₹25,727.72 (4.99%)Rejected-AOC TP 117 2ND FLOOR MAURYA ENCLAVE PITAMPURA DELHI 110034 | DELHI | DELHI | DELHI | 110034 | L3 | Rejected-AOC Other than lowest bidder | |
| 4 | L4₹5.5 L+₹30,586.52 (5.93%)Rejected-AOC | L4 | Rejected-AOC Other than lowest bidder | |
| 5 | L5₹6.5 L+₹1.4 L (26.3%)Rejected-AOC INDEX NO E 108 HQ CWE NO 2 DELHI CANTT J 636 SECTOR 23 SANJAY NAGAR GHAZIABAD UTTAR PRADESH 201002 | GHAZIABAD | UTTAR PRADESH | 201002 | L5 | Rejected-AOC Other than lowest bidder |
Tender Value
₹8.5 L
EMD Value
₹17,000
Closing Date
4 Sept 2024, 6:00 pmClosed
AGE I CG
AGE I CG Noida
REPAIR OF PUMP MOTOR, STARTER PANEL, PUMP CLEANING AND OTHER ALLIED WORKS UNDER AGE (I) CG NOIDA
2024_MES_663384_1
AGE I CGN 16 24 25
Open Tender
Electrical and Maintenance Works
Item Rate
AGE I CG NOIDA
E b i
8 documents required · 8 mandatory
₹500
AGE I CG
₹17,000
12 Dec 2024
2 Jul 2024
6 Sept 2024
2 Jul 2024
4 Sept 2024
17 Jul 2024
Amount
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 m in depth and getting out in soft/loose soil for laying of pipe , all complete as specified and directed.
Returning, filling in trenches including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil compete all as specified and directed.
Removal of excavated surplus soil to a distance not exc 50 m and depositing where directed at level not exc 1.5 m above the starting point all as directed by Engineer-in-Charge.
Taking up or down galvanised water tubing (medium grade) with all fitting from trenches/ walls/ floors/ ceilings and separating serviceable pipes and fittings for reuse in the work and removing unserviceable pipes and fittings from site of 15 to 20 mm bore tubing including removing rusted MS clamps from walls etc.(where necessary),complete all as specified and directed.
All as per item No 4.00 here-in-before but 25 mm bore tubing.
All as per item No 4.00 here-in-before but 40 mm bore tubing.
All as per item No 4.00 here-in-before but 50 mm bore tubing.
All as per item No 4.00 here-in-before but 65 mm bore tubing.
Taking up or down galvanised water tubing (medium grade) with all fitting from trenches/ walls/ floors/ ceilings and separating serviceable pipes and fittings of dia 80 mm bore tubing.
All as per item No 9.00 here-in-before but 100 mm bore tubing.
Supplying and laying galvanised steel water tubing (medium grade) complete with all fittings, laid in trenches, including testing for 20 mm bore tubing, complete all as specified and directed. Make :- TATA/JINDAL/PRAKASH/ZENITH
All as per Srl item No 11.00 here-in-before, but 25 mm bore tubing.
All as per Srl item No 11.00 here-in-before, but 40 mm bore tubing.
All as per Srl item No 11.00 here-in-before, but 50 mm bore tubing.
All as per Srl item No 11.00 here-in-before, but 80 mm bore tubing.
All as per Srl item No 11.00 here-in-before, but 100 mm bore tubing.
Supplying and laying galvanised steel water tubing (medium grade) complete with all fittings, fixed to wall and ceiling or laid in floors, including testing for 15mm bore tubing, including replace the rusted MS clamps on walls/ ceilings etc. complete all as specified and as directed. Make : TATA/JINDAL/PRAKASH/ZENITH
All as per Srl item No 17.00 here-in-before, but 20mm bore tubing.
All as per Srl item No 17.00 here-in-before, but 25mm bore tubing.
All as per Srl item No 17 here-in-before, but 40 mm bore tubing.
All as per item Srl No 17.00 here-in-before, but 50mm bore tubing.
All as per item Srl No 17.00 here-in-before, but 65 mm bore tubing.
All as per item No Srl 17.00 here-in-before, but 80mm bore tubing.
Fixing only after cleaning steel water tubing (galvanized) and connections with new GI fittings fixed to wall ceiling or laid in floor after cleaning, washing or removing old screw thread as required and providing new fittings wherever required for 15mm bore tubing, complete all as specified and directed.
All as per Srl item No 24.00 here-in-before, but 20mm bore tubing.
All as per Srl item No 24.00 here-in-before, but 25mm bore tubing.
S&F in repair/replacement ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe & fixed, of dia 25 mm (min wt. 455 gms), complete all as specified and directed. Make : PRAYAG/ POLYTUF
S&F in repair/replacement ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe & fixed, of dia 20 mm (min wt. -210 gms), complete all as specified and directed Make : PRAYAG/ POLYTUF
M&L for cutting existing steel tubing for alterations or additions (Each cut measured) for 15mm bore tubing, complete all as specified and directed.
All as per Srl item No 29.00 here-in-before, but 20mm bore tubing.
All as per Srl item No 29.00 here-in-before, but 25mm bore tubing.
All as per Srl item No 29.00 here-in-before, but 40mm bore tubing.
All as per Srl item No 29.00 here-in-before, but 50mm bore tubing.
Screwing existing steel tubing for alterations or additions (or lengthening screw on pipe to form connector) for 15mm bore tubing, complete all as specified and directed.
All as per Srl item No 34.00 here-in-before, but 20mm bore tubing.
All as per Srl item No 34.00 here-in-before, but 25mm bore tubing.
All as per Srl item No 34.00 here-in-before, but 40mm bore tubing.
All as per Srl item No 34.00 here-in-before, but 50mm bore tubing.
Dismantling of old unserviceable water tanks of capacity exceeding 250 ltrs and not exceeding 500 ltrs and removing from site, and deposited to store, complete all as specified and directed.
Dismantling of old unserviceable water tanks of capacity exceeding 500 ltrs and not exceeding 1000 ltrs and removing from site,and deposited to store, complete all as specified and directed.
Supplying, hoisting and fixing of multilayer, rotational moulded polyethylene water storage tank of capacity 500 ltrs (cylindrical vertical with closed top) in existing position including necessary connections of pipes, complete all as specified in SSR Part-I and as directed. Make: SINTEX/POLYCON/ROTAX.
All as per Srl item No 41.00 here-in-before, but of 1000 ltr capacity.
M&L for PCC 1:3:6 type C2 (using 40 mm graded crushed stone aggregate) as in base foundation of pillar etc, complete all as specified and directed.
M&L for rendering 10 mm thick in CM (1:4) on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement, complete all as specified and directed.
Cleaning and removing all scales and dirt etc. from tanks of capacity exc. 1000 litre and n.exc 2000 litre and also from mouth of circulating pipes, etc. complete all as specified and as directed.
Cleaning and removing all scales and dirt etc. from tanks of capacity exc. 500 litre and n.exc 1000 litre and also from mouth of circulating pipes, etc. complete all as specified and as directed.
S&F in repairs sluice valve of type PN-1.6 and size 80mm dia with gun metal raising spindle, both ends flanged, with iron wheel head conforming to IS-14846-2000, and drilled with necessary holes for bolts including jointing material viz nuts, bolts,rubber gaskets etc , complete all as specified and directed. Make : Kirloskar/ Venus/ RMCO/ Leader/HAZRA & other ISI Marked
All as per Srl item No 47.00 here-in-before, but 100 mm dia tubing.
All as per Srl item No 47.00 here-in-before, but 150 mm dia tubing.
S&F in repairs Non return valves with screwed both ends for Galvanised iron pipe and fixed for 80 mm dia, complete all as specified and directed. Make : SCUD/SHAKTI/LEADER/ZOLOTO Note: The quoted rate is deemed to be inclusive of cutting, threading, insertion of union joint, nipple etc for the required size of pipe.
S&F in repairs Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixing 20mm dia, complete all as specified and directed. Make : SCUD/SHAKTI/LEADER/ZOLOTO Note: The quoted rate is deemed to be inclusive of cutting, threading, insertion of union joint, nipple etc for the required size of pipe.
All as per Srl item No 51 here-in-before, but 25mm bore tubing.
All as per Srl item No 51 here-in-before, but 40mm bore tubing.
All as per Srl item No 51 here-in-before, but 50mm bore tubing.
S&F butterfly Valve Lever operated CI 65 m bore tubing.
M&L for construction of brick masonry valve pit with sub-class 'B' brick built in cement mortar (1:6), of size (100 x 100 x 100) cm (internal dimension) with one brick walling and 150 cm x 150 cm x 10 cm base foundation with PCC (1:3:6), type C2 with cement plastering 10 mm thick with cement mortar (1:4) on internal & exposed surfaces, including MS cover of size 01 mtr x 01 mtr made out from 3 mm thick MS sheet including (40 x 40 x 5) mm angle iron framing on MS cover as well as on top wall of the valve pit & painting of the steel surfaces with two coats of synthetic enamel paint (first quality) over a coat of red oxide primer, including necessary earth work and demolition of the existing old valve pit, complete all as specified and as directed.
All as per Srl Item No 56 but here in before size90X90x90 CM
All as per Srl Item No 56 but here in before size 60X60x60 CM
S&F in repairs GI flange (02 Nos), jointing with 04 Nos nuts, bolts washer, rubber or leather gasket including screwing and fixing for 80mm bore, etc, complete all as specified and directed.
All as per Srl item No 59.00 here-in-before, but 100 bore tubing.
S&F in repairs gate valves (Gun metal globe valve) with iron wheel head, screwed both ends for iron pipe and fixed for 15 mm dia, complete all as specified and directed. Make : SCUD/SHAKTI/LEADER/ZOLOTO Note: The quoted rate is deemed to be inclusive of cutting, threading, insertion of union joint, nipple etc for the required size of pipe.
All as per Srl item No 61 here-in-before, but 20mm bore tubing.
All as per Srl item No 61 here-in-before, but 25mm bore tubing.
All as per Srl item No 61 here-in-before, but 40mm bore tubing.
M&L for Collecting water sample in sealed 1 ltrs bottle and writing the location in presence of MES Rep from UG sump, over head tank, RO plant etc located at different sectors under AGE(I) CG Noida every month or as directed and testing for colour, Odour, PH, Taste, Turbuidity, TDS, Copper, Flouride, Free residual chlorine, Calcium, Iron, Magnesium, Sulphate , Total Alkalinity, Zinc,total hardness etc from Govt Approved Labs And Submit the report complete all as specifed and directed
Taking down the defective electric induction motor 50 HP capacity of Kirloskar make 415 Volt, 3 phase after disconnecting the electrical connections, removing the motor from bed, by decoupling with pump, transporting to workshop, dismantling rotor/ stator, bearing , oil seal etc and re-assembling the same after heating varnishing and , replacement of unserviceable spares eg bearing, oil seal etc and transporting back to site and refixing with proper aligment with the pump along with electrical connections including testing and commissioning, complete all as specified and as directed by the Engineer-in-Charge. Note: 1. Rewinding if required will be measured and paid seperately under relevant items of Sch 'A'. 2. Bearings/oil seal/other spares will be measured and paid sepately under relevant items of Sch 'A'.
All as per Srl item No. 66 above but electric motor of 2-3 HP capacity.
Dismantling and removing the burnt out winding from rotor/ stator and rewinding the rotor or stator with same type super enameled copper wire of same gauge and with necessary insulating material ,cotton tape etc .
S&F in replacement terminal board for 15 HP capacity motors complete all as specified.
S&F in replacement oil seal for induction motor 50 HP capacity
S&F in replacement oil seal for induction motor 2-3 HP capacity
S&F in replacement bearing for induction motor 50 HP capacity
S&F in replacement bearing for induction motor 2-3 HP capacity
M&L for overhauling of centrifugal pump set 50 HP capacity of make Kirloskar, by dismantling completely and replacing unserviceable ball bearing, shaft sleeve, gland, neck ring gland rope shield, unserviceable nut, bolt, washer etc. and reassembling the pump and fixing alignment to the original position and coupling with pump complete all as specified and as directed by the Engineer-in-Charge.
All as per Srl item No. 74 above but 2-3 HP capacity centrifugal pump set.
Supply only in repairs Ball bearing for pump 50 HP Capacity of make – SKF / NBC/ TATA
Supply only in repairs Ball bearing for pump 2-3 HP Capacity of make – SKF / NBC/ TATA /Toyo
Supply only stainless steel studs nut bolt for gland packing / motor bearing housing suitable for 50 HP capacity multi-stage centrifugal pump, complete all as specified and directed.
All as per Srl item No.78 above but pump of 2-3 HP capacity.
Supply only in repairs mechanical seal for pump 50 HP Capacity
Supply only in repairs mechanical seal for pump 2-3 HP Capacity
S&F in repairs, rubber flexible joy type coupling for 50 HP capacity motors/pumps complete all as specified and as directed by the Engineer-in-Charge. Model :- KWC 228
S&F in repairs, rubber gasket 3 to 6mm thick suitable for submersible/mono block pump sets & motors complete all as specified and as directed by the Engineer-in-Charge.
Supply only CI gland plate for centrifugal/mono block pumps 50 HP capacity.
M&L for painting to 50 HP capacity mono block/centrifugal pump and motor with two coats of synthetic enamel paint over one coat of red oxide primer including cleaning and degreasing the surface complete all as specified and as directed by the Engineer-in-Charge.
M&L for overhauling of existing star delta starter, cleaning of all power contactor terminals replacement if required and renewal of unserviceable perished copper wiring, aluminium/ copper lugs, push buttons and indication lamps etc, including necessary electrical connections and testing the motor with load complete all as specified and as directed by the Engineer-in-Charge.
S&F in replacement Contactor Coil suitable for MNX 25. Make : L&T/ABB/Havells
S&F in replacement Contactor Coil suitable for MNX 50. Make : L&T/ABB/Havells
S&F in replacement Contactor MNX 25 complete all as specified and directed. Make : L&T/ABB/Havells
S&F in replacement Contactor MNX 50 complete all as specified and directed. Make : L&T/ABB/Havells
S&F in replacement Relay rating 45 to 75 sec. complete all as specified and directed. Make : L&T/ABB/Havells
S&F in replacement Timer ST-100 rating 01 to 45 sec. complete all as specified and directed. Make : L&T/ABB/Havells
Disconnecting carefully old unserviceable Ammeter from panel board and S&F new 96 mm size square / circular digital type ammeter of range 0-30 Ampere or 0-100 Ampere, size of letters 25 mm, with set of CTs of suitable rating, necessary connecting / fixing arrangement and testing complete all as specified and directed. Make AE or Equivalent
Disconnecting carefully old unserviceable Voltmeter from panel board and S&F new 96 mm size square / circular digital type Voltmeter of range 0-500 Volt, size of letters 25 mm, Make – AE (ISI Marked), necessary connecting / fixing arrangement and testing complete all as specified and directed. Make AE or Equivalent
M&L for cleaning of water supply under ground sump of capacity 40,000 gallons capaity by balling out the accumulated water at the bottom and removing the complete silt and disposing levelling as directed and cleaning with bleaching powder and wire brush after scrapping the walls and bottom of the sump complete including white washing inside and one coat of cement based paint on out side surface of sump without disturbing the water supply to the area and painting for the capacity and date of cleaning of sump in dd/mm/yyyy in bold capital letters of and including painting to air vent pipes, ladders, valve pit covers and covering mosquitoes proof complete all as specified and as directed by the Engineer-in-Charge.
S&F in repairs CI flanged foot valve suitable for 100 mm dia pipe complete with necessary bolts, nuts, gasket etc. all as specified and directed by Engineeer-in-Charge. Make: KIRLOSKAR / L&T / VENUS
S&F in replacement gasket washer suitable for 80/100 mm dia all as specified and directed by Engineeer-in-Charge.
S&F in replacement gland packing 6mm/8mm/10mm, complete all as specified and as directed.
M&L for preparation of old steel surface & applying one coat of synthetic enamel paint (first quality), complete all as specified and directed.
Supply only PVC insulated single core stranded copper conductor conforming to IS: 694 (1990) 1100 volts grade 16 Sqmm, complete all as specified and directed. Make : FINOLEX/HAVELLS/PLAZA/NICCO/L&T
Repairing, servicing and overhauling of chlorine dosing pump model RM-11, make RMCO including disconnecting and refixing of Suction and delivery pipe, and transporting to work shop for necessary repairs and replacement of unserviceable spare parts, with new spare parts and testing, complete all as specified and directed. NOTE: Spares required for repairing of the dosing pump shall be measured and paid separately under respective item here-in-after.
S&F in replacement non return valve for dosing pump of model RM 11 complete all as specified and as directed.
S&F in replacement LDPE pipe as per sample, for dosing pump of model RM 11 complete all as specified and as directed. Make: KISAN/SUPREME/PRINCE/FINOLEX
S&F in replacement discharge valve Assembly, for dosing pump of model RM 11 complete all as specified and as directed.
S&F in replacement diaphragm, for dosing pump of model RM 11 complete all as specified and as directed.
S&F in replacement suction valve assembly, for dosing pump of model RM 11 complete all as specified and as directed.
S&F in replacement pressure relief valve, for dosing pump of model RM 11 complete all as specified and as directed.
S&F in replacement foot valve assembly, for dosing pump of model RM 11 complete all as specified and as directed.
S&F in replacement ball ceramic, for dosing pump of model RM 11 complete all as specified and as directed.
S&F in replacement Manual Motor controller Supernova MOG -S1-2000, 3 Ph, suitable for 15 Hp Moter Strter panel complete all as specified . Make: L&T /ABB/Havells
M&L for overhauling of centrifugal pump set 15 HP capacity of make Kirloskar,replacing unserviceable ball bearing, shaft sleeve, gland, neck ring gland rope shield, unserviceable nut, bolt, washer etc. and reassembling the pump and fixing alignment to the original position and coupling with pump complete all as specified and as directed by the Engineer-in-Charge.
All as per item Srl No.111.00 above but rewinding of electric motor of 15 HP capacity.
S&F in replacement Foot valve 80mm Dia with washer , gasket nut bolt strainer complet all as directed and specified by the Engr- in - Charge
S&F in replacement Foot valve 63 mm Dia with washer, gasket nut bolt strainer complet all as directed and specified by the Engr- in - Charge
S&F in replacement 3 pole Contactor MNX 32 Make : L&T/ABB/Havells
S&F in replacement 3 pole Contactor MNX 18 Make : L&T/ABB/Havells
S&F in repair Contactor Front mounting add on aux contct block 2NO+ 2NC complete Make : L&T/ABB/Havells
S&F in replacement single phase preventor (Minilec-VSP-2/3) for starter panels at diffrents locations complete all as specified and directed.
S&F 3 core 4 Sqmm PVC flexible copper cable for suction sweeper pump suitable length complete all as specified and directed.
M&L for overhauling of non closing centrifugal Sewage pump set 5 HP capacity installed at sec -52 , replacing unserviceable ball bearing, shaft sleeve, gland, neck ring gland rope shield, unserviceable nut, bolt, washer etc. and reassembling the pump and fixing alignment to the original position and coupling with pump complete all as specified and as directed by the Engineer-in-Charge.
S&F in replacement PVC suction hose pipe round of required size dia and length approx 5-7 mtr from sewage sump to sewage pumpset including arrangment of nipples flanges, Rubber gasket, reducers at suction end and nut bolt clamps, and PVC strainer/ footvalve at last end complete all as specified by Engr in Charge.
PRASAD ELECTRICALS (BID ID -3081641)
GLIBS CONSTRUCTION (BID ID -3072811)
V.V CONSTRUCTIONS (BID ID -3083499)
KRISHANA ELECTRIC WORKS (BID ID -3071201)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .