| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹24.6 LAccepted-AOC | ₹24.6 L | L-1 | Accepted-AOC Due to L-1 |
| 2 | L-2₹27.1 L+₹2.6 L (10.4%)Rejected-Finance | ₹27.1 L+₹2.6 L (10.4%) | L-2 | Rejected-Finance Due to L-2 |
| 3 | L-3₹28.3 L+₹3.7 L (15.1%)Rejected-Finance B 30 JEEVAN VIHAR SHASTRI NAGAR GHAZIABAD UTTAR PRADESH 201001 | GHAZIABAD | UTTAR PRADESH | 201001 | ₹28.3 L+₹3.7 L (15.1%) | L-3 | Rejected-Finance Due to L-3 |
| 4 | Rejected-Technical | - | - | Rejected-Technical Online papers are not uploaded on CPP portal as per NIT |
Tender Value
₹34.6 L
EMD Value
₹69,200
Closing Date
8 Feb 2020, 5:30 pmClosed
Head, CSIR-HRDC
Sector-19, Kamla Neharu Nagar, Ghaziabad-201002
AMC for operation and routine maintenance of 11 KV substation, DG Sets, Pump house i/c internal and external electrification, HT LT panels, DB, internal telephone wiring and maint. and servicing for A.C. Units etc. in CSIR-HRDC Campus, Ghaziabad
2020_CSIR_41751_1
9-1(1)/2019-20/Elect./AMC/HRDC
Open Tender
Electrical Works
Item Rate
365 days
CSIR-HRDC
Please refer tender documents
4 documents required · 4 mandatory
₹500
HRDC, GHAZIABAD
₹69,200
13 Mar 2020
31 Jan 2020
11 Feb 2020
1 Feb 2020
8 Feb 2020
1 Feb 2020
Amount
Sub Head- I:Operation and routine maintenance of 11 KV Substation , D.G.Sets,PumpElectrical panel and distribution boards etc. 1.01 :Operation and day to day routine maintenance of 11 KV Sub-Station,DG Sets ,Pump house, starter panels, tube well, water storage Tank, internal & external electrification and telephone wiring including following accessories : - 630 KVA Transformer - 02 no., 11 KV HT Panel with 6nos VCB - 01 no. , LT Panel - 01 no., Capacitor bank panel - 02no.,180 AH, 12 Volt Battery/65AH,12V,battry- 04 no. , DG Set 380 KVA with Alternator- 02 no.,DG set AMFPanel - 02 no.,Inveters 3KVA/850 VA - 04 no., D.B. in Office building & Colony. L.S, 7.5 HP monoblock pump Set -03 no.,10 HP monoblock pump Set - 02 no.,5 HP monoblock pump Set - 03 no. ,3 HP monoblock pump Set - 03 no.,3 HP sum pump Set - 01 no.,7.5 HP Sumbersible pump Motor Set -01 no.,10 HP Sumbersible pump Motor Set- 02 no. The item includes repair/replacement of essential consumable like cleaning material viz cotton waste, greese, distel water, nut bolt, screw, PVC insulation tape, soap, gland and detergent etc.and maintaining the log book day to day work. Required tools provided by contractor . Details as per annexure-I
Operation and day to day routine maintenance/sevicing and repairing work of following Air conditioning units etc. complete as per direction of engineer incharge:- a) Window A.C. 1.5/2.0 TR with stablizers - 78 Nos. b) Split A.C. 1.5/ 2.0 TR with stablizers - - 47 Nos. c) Tower A.C. 2 TR with stablizers - --08 Nos. d) Water cooler up to 120 Ltrs. - - 02 Nos. e) Water dispenser up to 60 Ltrs. - -04 Nos. f) Refrigerator up to 500 ltrs capecity - --01 Nos. The item includes repair/replacement of essential consumable like cleaning material viz cotton waste, greese,lubricant oil, thimbls, nut bolt, screw, PVC insulation tape, soap and detergent etc.and maintaining the log book day to day work. Required tools provided by contractor Details as per annexure-II
Sub-Head-II Repair/ Replacement of following Electrical,mechanical components and accessories. 2.01 :GLS lamp up to 100 W,250V
Tube light 40 W
LED Tube light 16 W for 2feet fitting
Tube light 20 W
LED Tube light 20 W for 4 fitting
CFL 18 W Essential
Halogen 500 W
Halogen 1000 W
Choke copper K-20
Choke copper K-40
Starter for 1x20 W FTL, 110V
Starter for 20/40/80 W FTL, 240V
Ignitors for 70-400 W SON lamp
Metal clad Industrial plug 2 pole + Earth 250V , 20A
Metal clad Industrial Socket 2 pole + Earth 250V , 20A
Contactor MNX550,240 Volt, 50 Hz , Make- L&T
PVC insulated copper conductor, single core multistrend wire/cable 1.5 sqmm
PVC insulated copper conductor, single core multistrend wire/cable 2.5 sqmm
FRLS PVC insulated annealed copper conductor, unarmored telephone cable ,four pair, 0.5mm dia
SP 5/6 Amps.one way switch piano type ISI Marked
SP 15/16 Amps.one way switch piano type ISI Marked
6 Pin 15/16 & 5/6 A socket outlet piano type ISI Marked
SP 5/6 Amps.one way modular switch ISI Marked
SP 15/16 Amps.one way modular switch ISI Marked
6 Pin 15/16 & 5/6 A modular socket outlet ISI Marked
GI modular Box 3 module
GI modular Box 6 module
Modular base & cover plate 3 module
Modular base & cover plate 6 module
Call bell/buzzer suitable for D.C./A.C. single phase, 230 volts
Single pole MCB 5 to 32 Amps ,B series, 240 volts
Fly cacher tube light 18 W
Driver for 30W LED street light for Wipro make
32A,DP main switch with key ring tag 2modul
Hermetically sealed Rotary compressor for 1.5 Ton A.C. Unit for all branded AC
Hermetically sealed Rotary compressor for 2.0 Ton A.C. Unit for all branded AC
Refrigerant R-22/410
Runing capecitor 36/45 MFD
Starting capeciter 80 MFD
Fan motor doublr shaft for 1.5/2 Ton window A.C.
PCB card for 1.5/2.0 ton Split AC unit
Relay for 1.5/2.0 Ton AC
Split AC fan motor for outdoor unit 1.5 / 2 ton
Split AC fan motor for indoor unit 1.5 / 2 ton
Sub-Head-III Overhauling, servicing and rewinding of work. Rewinding and overhauling of following mono block pump motor including replacement of bearings water seal rusted nut & bolt, repairing of shaft & impeller etc. after disconnecting and reinstallation of the same complete in all respect. 3.01 : 10 HP
The labour charges for taking out and lowring in same of sumbersible pump set up to 10 HP from borewel including charges of chain pulley and tripol stand etc . Complete in all respect.
Rewinding and assembling of following submersible pump motor with oil seal and including replacement of all necessary spares required for smooth functioning of moter complete in all respect. 5.01 : 7.5 H.P.
Rewinding and overhauling of following exhaust fan replacement of bushes bearing shaft including capacitor etc. complete as required 6.01 : 9" Exhaust fan
12" Exhaust fan
18" Exhaust fan
Rewinding and overhauling of following ceiling fan including Bushes, Bearing, bearing, shaft and capecitor, etc. complete as required. 7.01 : 48" Ceiling fan
56" Ceiling fan
Repairing & maintenance charges of all makes 4/5 KVA A.C. Units voltage stabilizer including PCB and relay etc. complete as required.
Chanchal Eelctricals
B S ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .