| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹89.7 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹95.0 L+₹5.1 L (5.62%)Rejected-AOC | L2 | Rejected-AOC Other than Lowest Bidder | |
| 3 | L3₹96.3 L+₹6.4 L (7.07%)Rejected-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L3 | Rejected-AOC Other than Lowest Bidder | |
| 4 | L4₹99.3 L+₹9.4 L (10.5%)Rejected-AOC VILL CHOMON ADAMPUR JALANDHAR PUNJAB 144103 UDYAM PB 10 0011450 | JALANDHAR | PUNJAB | 144103 | L4 | Rejected-AOC Other than Lowest Bidder | |
| 5 | L5₹1.1 Cr+₹19.7 L (22.0%)Rejected-AOC GP RAM COLONY AMRITSAR JALANDHAR 144103 | AMRITSAR | AMRITSAR | PUNJAB | 144103 | L5 | Rejected-AOC Other than Lowest Bidder |
Tender Value
Refer Docs
Closing Date
7 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) CHANDIGARH
HQ CWE (AF) CHANDIGARH PIN-160003
PROVISION OF OTM ACCOMMODATION AT AF STN ADAMPUR
2021_MES_496881_1
CWE/AF CHD/ADM/T-26/2021-2022
Open Tender
Civil Works
Lump-sum
180 days
Adampur
As per NIT
8 documents required · 8 mandatory
₹1,000
GA (AF) Adampur
Exempted
2 Mar 2022
23 Dec 2021
14 Feb 2022
23 Dec 2021
7 Feb 2022
24 Jan 2022
60 days
Amount
GENERAL SUMMARY
Schedule 'A' Part XIV "MISC ITEMS OF WORKS" Note:- This Schedule is not pre priced by MES and Pre-Priced rate as "Rs 0.00" under Column 5 signifies this fact only
CHAIN PULLEY BLOCK
Provn of Triple spur Gear Chain Pulley block capacity 3 tonnes with 3 mtrs lift complete all as specified and directed. Prod code 31713 Make HIRA
FIRE FIGHTING
Supply, installation, testing & commissioning Network Repeater Panel, each Repeater Panel shall work as node and communicate Peer to Peer with other panels, each repeater panel shall display information of all panels in network on LCD display, the LCD shall display all events/ detectors, devices srttus of complete systems in the network, complete all as specified and directed. Make- Morley by Honeywell or equivalent.
Material and Labour for DC Power Supply 24 Volts 10 Amp, complete all as specified and directed. Make- Morley by Honeywell or equivalent.
Material and Labour for Supply of Battery 7.2 mah, 12 Volts, complete all as specified and directed. Make- Morley by Honeywell or equivalent.
Supply, installation, tesing and commisioning copper armoured cable 2 core 1.5 sqmm laying on surface along with required accessories, complete all as specified and directed.
Supply, installation, tesing and commisioning copper armoured cable 4 core 1.5 sqmm laying on surface along wirh required accessories , complete all as specified and directed.
Supply and fixing PVC conduit pipe 25 mm heavy duty pipe, complete all as specified and directed.
AIR CONDITIONING
Supply and fixing Voltage stabilizer of 5 KVA capacity for automatic operation, single phase naturally air cooled, indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% for 2 Ton AC, complete all as specified and directed.
Supply and fixing Voltage stabilizer of 5 KVA capacity for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% for 1.5 Ton AC, complete all as specified and directed.
ROAD, PATH AND CULVERT
Material and labour for 150 mm thick (compacted thickness) GSB of grading I as per morth specifications, surface formed, rolled and consolidated to required gradient and camber using earth compacator of 8 to 15 tonne capacity, complete all as specified and directed.
Material and labour for wet mixed macadam 150 mm thick (compacted thickness) in two layers of 7.5 cm thick each with coarse aggregate of specified grade as per morth specifications, spread, rolled and consolidated to required gradient and camber using power roller of 8 to 15 tonne capacity, complete all as specified and directed. (Note: Mix will be prepared in WMM mixing plant of suitable capacity as specified.)
Material and labour for 150 mm thick (compacted thickness) Dry Lean Concrete with 7 days compressive strength of 10 N/Sqmm, using minimum cement content of 240 kg/cum and crushed stone aggregate of grading as per Morth specifications, including necessary steel form work and spreading, rolling and consolidating to required gradient and camber complete all as specified and directed.
Material and labour for 200 mm thick (minimum) PQC work in pavement/ hardstanding, of flexural strength of 45 kg/sqcm in field, using 400 kg of cement per cubic metre, including necessary form work, bullnosing, rounding off edges, finishing by mechanical brooming/belting, curing etc complete all as specified and directed.
Material and labour for laying 400 micron HDPE polythene film including all necessary cutting, with overlaps not less than 300 mm length/widthwise, including application of tack coat of bitumen of grade VG-10 @ 2.5 Kg/10 Sqm, complete all as specified and directed.
Material and labour for forming construction joints 25 mm deep x 8mm in PQC slab, preparing & cleaning of sides, bottom and edges, cleaning the surface of the joints with wire & coir brushes and finally removing & cleaning dust etc with compressed air to make it free from all foreign particles, priming the surface with primer and filling with polyurethane joint sealing compound using mechnical means to a minimum depth of 12 mm ( minimum depth above the backup rod) and leaving 3mm on top, including one coat of primer and providing approved quality closed cell polythene back up rod/back up sheet of required size & shape, applying masking tape on edges to prevent accidental slippage on solvent on top surface and to give a neat finish to sealent and removing the masking tape after sealent is applied as required, complete all as per manufracturer's instrucions, including removal of loose & foreign materials outside MoD land, complete all as specified and directed.
Material and labour for forming contraction/ dummy joints of width 8 mm & depth 67 mm (1/3rd of depth of slab) in PQC slab using mechanically operated diamond tip concrete cutter, preparing & cleaning of sides, bottom and edges, cleaning the surface of the joints with wire & coir brushes and finally removing & cleaning dust etc with compressed air to make it free from all foreign particles, priming the surface with primer and top 25x8mm filling with polyurethane joint sealing compound using mechnical means to a minimum depth of 12 mm ( minimum depth above the backup rod) and leaving 3mm on top, including one coat of primer and providing approved quality closed cell polythene back up rod/back up sheet of required size & shape, applying masking tape on edges to prevent accidental slippage on solvent on top surface and to give a neat finish to sealent and removing the masking tape after sealent is applied as required, complete all as per manufracturer's instrucions, including removal of loose & foreign materials outside MoD land, complete all as specified and directed.
Material and labour for forming 25 mm thick Expansion joints to full depth in PQC slab, preparing & cleaning of sides, bottom and edges of adjoining slabs, cleaning the surface of the joints with wire & coir brushes and finally removing & cleaning dust etc with compressed air to make it free from all foreign particles, filled with compressible synthetic filler board and top 30mm primed with primer and filling with polyurethane joint sealing compound using mechnical means to a minimum depth of 10mm ( minimum depth above the backup rod), including one coat of primer and providing approved quality closed cell polythene back up rod/back up sheet of required size & shape over compressible synthetic filler board in position, applying masking tape on edges to prevent accidental slippage on solvent on top surface and to give a neat finish to sealent and removing the masking tape after sealent is applied as required, complete all as per manufracturer's instructions, including removal of loose & foreign materials outside MoD land, complete all as specified and directed.
Material and labour for painting 2 mm thick thermoplast fluorescent paint, colour white or golden yellow or any other approved shade, confirming to BS standard 3262, with 20% glass beads (inter mixed), applied hot with automatic (commercial) machine drive in strips after preparation of surfaces as per manufacturer's instructions & according to the specifications laid down by IRC * MOST (Ministary of surface Transport) specifications 2001 (4th revesion), making lines, broken lines/dashes, arrows etc, on road and other like surfaces exceeding 10 cm but not exceeding 20 cm in width or girth, complete all as specifed and directed.
EXTERNAL ELECTRIFICATION
Supply and fixing thunderstroke protector 60 ESE, which shall be an active lightning conductor designed to conform to the French Standard NFC 17 102:2011 ΔT: 60 us for ESE lightning conductor, capable to maintain local electrostatic field that develops naturally around the system as a thunderstorm begins to gather. In the event of descending lightning, an inbuilt triggering device should generate high tension pulls at the conductor tip, causing a 'Corona effect'. It should be tested in international/national testing laboratory duly accredited by ILAC/IEC/ENAC/ EZU to ensure the genuine testing , CPRI Tested and the quality of the product/ the serial number shall be displayed on the ESE lightning arrester duly supported with the " certificate of OEM". Protection radius shall be 79 meter at level 1 and 107 meter at level 4, complete all as specifed and directed. Make- REMEDIES or Equivalent. Note:- The item shall be in Warranty period of 10 years from the date of certified completion of work.
Supply and fixing supporting mast of GI pipe Light Grade 50 mm dia for thunderstroke protector of required length with all necessary MS/GI fittings for mounting arrangement for the down conductor including bakalite insulator, complete all as specifed and directed. Make- REMEDIES or Equivalent.
Supply and fixing self - powered non resttable lightning event counter (6 digits) mounted on down conductor in IP 65 enclosure with minimum sensitivity 1 KA for 8/20 up pulse, complete all as specifed and directed. Make- REMEDIES or Equivalent.
Supply and fixing DOWN CONDUCTOR 70 Sqmm PVC insulated single core copper cable, complete all as specifed and directed.
Material and labour for RESPL-CBR 173 maintenace free earthing consisting of copper bonded ground rod 17.2 mm dia, length 3000 mm (250 microns), manufactured by an electrolytic process of 99.99% pure electrolytic copper coating on low carbon, high tensile steel rod, along with Earth rod clamp, earth resistance improvement compound - 25 kg (containing mixture of Graphite, Activated carbon, sulphate, silica, alumina, iron oxide, graphite, activated carbon, etc), backfill compound shall be ROHS and thernal stability tested and result shall be less or equal to 1 ohm complete all as specifed and directed. Make: REMEDIES , INDIA or Equivalent.
Supply and fixing Test Link poly-carbonated box complete all as specifed and directed.
Material and labour for earth continuity conductor or main earthing lead 25 mm x 3 mm GI strip for interconnection of earthing rod, fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required complete all as specified and directed.
Supply and fixing Polymer round earth pit cover (Large size ) Make- REMEDIES or Equivalent.
Material and Labour for loadine MCCB Encloures Four Pole suitable for MCCB 160 A of 25 KA incomer, complete all as specified and directed. Make: Cat part No: IHEFFP of Havells or Equivalent from the makes mentioned in Appx 'B'
Material and Labour for 4 pole MCCB 250 Amp, 50 Hz, 415 V with rupturing capacity 35 KA, complete all as specified and directed. Make: Cat part No:IHLFN40250 # of Havells or Equivalent from the makes mentioned in Appx 'B'
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including provison of HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure, complete all as specified and directed.
INTERNAL ELECTRIFICATION
Supply and installation, commissioning and testing Ploycarbonate ASTA approved OEM made main LT Panel. The 4 way VTPN DB shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES and shall be UV resistance in accordance with IEC 61439-1, clause 10.2.4 DB, anti-acid, anti corrosive, glow wire test 9602 degree centigrade in accordance with 60695-2-11 (flame retardant and self-extinguishing), mechanical load shall be IK08 (5 Joule). The gasket shall be internally embedded and made of polyurethane. MCBs shall be connected on copper bus bar with main incomer, complete all as specified and directed. Make: Hensel/Rittal/Emitter/Schneider. (a) INCOMER: 160 Amp, 4 pole MCCB, 16 KA - 01 No. (b) OUTGOINGS: MCB 63 Amp, 415 V, 4 Pole TPN - 03 Nos. MCB 16 Amp, 415 V, 4 Pole TPN - 02 Nos. MCB 32 Amp, 415 V, 4 Pole TPN - 01 No. MCB 16 Amp, 220 V, 2 Pole DP - 01 No. MCB 10 Amp, 220 V , 2 Pole DP - 01 No.
Supply and installation, commissioning and testing Ploycarbonate ASTA approved OEM made main LT Panel. The 4 way VTPN DB shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES and shall be UV resistance in accordance with IEC 61439-1, clause 10.2.4 DB, anti-acid, anti corrosive, glow wire test 9602 degree centigrade in accordance with 60695-2-11 (flame retardant and self-extinguishing), mechanical load shall be IK08 (5 Joule). The gasket shall be internally embedded and made of polyurethane. MCBs shall be connected on copper bus bar with main incomer, complete all as specified and directed. Make: Hensel/Rittal/Emitter/Schneider. (a) INCOMER: 63 Amp, 4 Pole MCCB, 10 KA-01 No. (b) OUTGOING: MCB 63 Amp, 415 V, 4 pole TPN - 01 Nos. MCB 25 amp, 415 V 4 pole TPN - 02 Nos MCB 32 Amp, 220 V, 2 pole DP- 01 No, MCB 6 Amp, 220 V, 2 pole DP- 01 No, MCB 6 Amp, 220 V , 2 pole DP- 01 No , MCB 32 Amp, 415 V, 4 pole TPN-01 No, MCB 16 Amp, 220 V, 2 pole DP-01 No
Supply and installation, commissioning and testing Ploycarbonate ASTA approved OEM made main LT Panel. The 4 way VTPN DB shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES and shall be UV resistance in accordance with IEC 61439-1, clause 10.2.4 DB, anti-acid, anti corrosive, glow wire test 9602 degree centigrade in accordance with 60695-2-11 (flame retardant and self-extinguishing), mechanical load shall be IK08 (5 Joule). The gasket shall be internally embedded and made of polyurethane. MCBs shall be connected on copper bus bar with main incomer, complete all as specified and directed. Make: Hensel/Rittal/Emitter/Schneider. INCOMER: 63 Amp, MCCB 4 pole, 10KA-01 No, OUTGOING : MCB6-32 Amp, 220 V, 2 pole SPN-04 Nos.
Material and Labour for flame proof, zone I & II, Gas Group II A/ II B, weather proof point wiring for one light point controlled by one switch using approved colour coding as per IS with zero halogen flame retardent (HFFR) smoke free non toxic, non corrosive PVC insulated unsheated flexible copper conductor cable 1.5 Sqmm (nominal area) single core, 1100 volts grade in and including (ERW) stove enamelled conduit, heavy duty, ISI marked, duly welded, flame proof weather proof junction box, tee, bends, inspection bends etc all as required, including PVC insulated unsheated flexible copper conductor cable 1.5 Sqmm (nominal area) single core 1100 volts grade as earth continuity conductor complete all as specified and directed.
Supply and fixing flame proof, weather proof, zone I & II, Gas Group II A/ II B, exhaust fan of size 305 mm, single phase, having1440 rpm speed, complete all as specified and directed.
J and K constructions company
R D Bansal
M/s Sahib and Company
AAR KAY BEE ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .