Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.3 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹47.4 L+₹3.1 L (7.07%)Rejected-AOC | L2 | Rejected-AOC Not L1 | |
| 3 | L3₹48.3 L+₹4.1 L (9.15%)Rejected-AOC MB NO 180 MG ROAD JUNGLIGHAT PORT BLAIR 744 103 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L3 | Rejected-AOC Not L1 | |
| 4 | L4₹48.9 L+₹4.6 L (10.4%)Rejected-AOC AUSTINABAD CHINTAMBAR COLONY PORT BLAIR SOUTH ANDAMAN 744 103 | PORT BLAIR | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744103 | L4 | Rejected-AOC Not L1 | |
| 5 | L5₹49.0 L+₹4.7 L (10.6%)Rejected-AOC | L5 | Rejected-AOC Not L1 |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
14 Aug 2021, 6:00 pmClosed
GE Brichgunj
GE Brichgunj Port Blair
PROVISION OF BATHROOM BLOCK AND WASHING POINT WITH WASHING PLAT FORM NEAR BUILDING NUMBER P-496 AND P-497 MT AREA OF 710 FIELD COMPANY AND PROVN OF RAIN WATER HARVESTING TO SHED AT BDE CAMP BLDG NO P-164A AND P-164B AT BRICHGUNJ MILITARY STATION PORT
2021_MES_462404_1
GE8144A
Open Tender
Civil Works
Item Rate
180 days
Brichgunj
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE Brichgunj
₹84,000
Yes
27 Sept 2021
24 Jul 2021
16 Aug 2021
24 Jul 2021
14 Aug 2021
7 Aug 2021
24 Jul 2021 - 6 Aug 2021
Amount
Surface dressing n.exc 15cm deep and getting out in soft / loose soil all as specified and directed
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft / loose soil all as specified and directed
Excavation in trenches n. exc. 1.5 m wide and not exceeding 1.5 m in depth, for foundation / laying of cables / pipe lines etc or for shafts, walls, cesspits, manholes, pier holes, etc getting out in soft/loose soil, complete all as specified and as directed.
Excavation over areas exc. 1.5m deep and n.exc 3.0m deep getting out in soft/ dense soil
Excavation over areas n.exc. 1.5m deep and getting out in soft /loose soil.
Excavation over areas exc. 1.5m deep and n. exc 3.00m and getting out in soft /loose soil.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type soil complete all as specified and as directed.
Removing excavated material (soil) not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
Supply and filling pulverized stone dust to the full width of trenches for protection of cables including spreading and punning down including watering consolidation complete all as specified and directed. Note: Thickness of stone dust will be paid after cushioning after punning.
Material and labour brick bats Filling using sub class B bricks complete all as specified and directed.
Material and labour for Filling 40mm graded stone aggregate as complete all as specified and directed.
Material and labour Moorum / red bajri filling in bed or filling in sides of trenches laid in layers n.exc. 15cm thick spread, levelled and rammed including watering complete all as specified and directed.
Material and labour Hard Core of gauge n.exc. 63mm deposited spread and levelled in layers n.exc. 15 cm thick watered and rolled/ rammed to a true surfce.
Material and labour PCC 1:4:8 type D-2 using 40 mm graded stone aggregate in 100mm thick as in sub base complete all as specified and directed.
Material and labour for 40 mm thick cement concrete 1:2:4, Type B-1 using 20 mm graded aggregate as in floor even & fair finishes complete all as specified and directed.
Material and labour for PCC 1:3:6 Type C1 using 20mm graded aggregate of 75mm thick as in Plinth Protection complete all as specified and directed. .
Material and labour PCC 1:2:4 Type B1 using 20mm graded stone aggregate as in surface channel / benching incl cost of use and waste of clean sawn wooden form work all as specified
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mi-ted/stoped ends etc
Material and labour Plain cement concrete 1:4:8 Type D2 using 40mm graded stone aggregate as in foundation filling
Material and labour Plain cement concrete 1:3:6 Type C2 using 40mm graded stone aggregate as in foundation filling
Material and labour Precast Cement Concrete Block Masonry with Solid Block, exc 10cm in width in Type C-1, 1:3:6 (using 20mm graded stone aggregate) set in CM (1:6) all as specified.
Material and labour PCC 1:5:10 Type E2 using 40mm graded stone aggregate as in foundation/mass concrete, filling etc, complete.
Forming construction joint 30mm wide deepX10mm wide filled with sealing compound Grade'A'
Material and labour for precast man holes cover slab with 1:2:4 Type B1 using 20mm graded stone aggregate set in CM 1:4 incl cost of use and waste of clean sawn wooden form work but excl cost of reinforcement all as specified
Material and labour for RCC M -30 Design Mix as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete all as specified and directed
Material and labour for RCC M -30 Design Mix as in columns, pillars, piers, posts and struts as specified and directed
Material and labour for RCC M -30 Design Mix as in beams, cantilevers, bressummers, lintels over 1.5m span as specified and directed
Material and labour for RCC M -30 Design Mix as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and directed
Material and labour cement concrete (design mix) M-30 for Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses
Material and labour foe Use and waste of form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for Fair finished surfaces.
Use and waste of form work to sides of pillars, posts, struts, piers, columns and stanchions
Use and waste of Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses etc.; vertical or to batter curved for rough finish surface of concrete.
Use and waste of form work to sides and sofit of Beams for Fair finished surfaces.
Use and waste of form work to sides and soffit of Roof Slab & Chajja etc for Fair finished surfaces.
Use and waste of Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide for fair finish surface of concrete.
Material and labour TMT bars 10 mm dia and over cut to length bent to shape required and binding with mild steel wire annealed not less than 0.9 mm dia
Material and labour TMT bars 6 mm to 8mm dia cut to length bent to shape required and binding with mild steel wire annealed not less than 0.9 mm dia
All as per item No 37 here in before but 5mm dia and over up to and including 10mm dia as in stirrups, spacers, binders and the like complete all as specified & directed
Material and labour Rendering 10mm thick on concrete surfaces in CM (1:6) finished even & smooth without using extra cement complete all as specified & directed
Material and labour Rendering 10mm thick on concrete surfaces such as sofit of slab, chajja etc in CM (1:3) finished even & smooth without using extra cement complete all as specified & directed
Material and labour for 15mm thick external rendering in two layers of 5mm thick in CM (1:4) mixed with water proofing compound (water proofing compound shall be @3% weight of cement) over and including a coat of 10mm thick in CM (1:6) over brick or concrete surfaces finished even and fair. Note: Supply only WPC will be measured and paid separately
Material and labour Rendering 15mm thick on concrete surfaces such as sofit of slab, chajja etc in CM (1:3) finished even & smooth without using extra cement including using 2% of WPC complete all as specified & directed
Supply only water proofing compound (Powder) conforming to IS-2645 1975.
Material and labour Rendering 10mm thick cement mortar on concrete surfaces in CM 1:3 finished even and smooth w/o using extra cement including using waterproofing compound with coat of epoxy.
Preparation of newly plastered surface and applying two coats of OBD on walls all as specified and directed.
Preparation of newly plastered Ceiling surfaces and applying two coats white wash complete all as specified & directed
Material and labour Preparation of Newly plastered surfaces of Wall and applying two coats of exterior emulsion antifungal paint all as specified and directed.
Material and Labour for water proofing treatment with the following specifications complete all as specified and as per manufacturer’s instructions:- (i) Rendering 10mm thick in CM 1:4 on concrete surfaces mixed with water proofing compound @ 3% by weight of cement as leveling course (ii) Apply a coat of hot blown bitumen 85/25 @ 1.20 kg/sqm over a coat of bituminous primer @ 0.3 ltr per sqm. (iii) Laying APP membrane (STP Aquashield or equivalent) weighing not less than 3.5Kg/sqm, reinforced with polyster non woven fabric (weighing not less than 150 gms/sqm) with 100mm over laps both longitudinally and transversally and overlaps shall be sealed by torch, membrane shall be taken to the parapet through fillet and shall be tucked in inside after a height of 300 mm. (iv) Apply one coat of hot blown bitumen 85/25 @ 1.2 kg/sqm over the membrane. Note:- Water proofing compound shall be measured and paid separately)
Material and labour Coloured Non-Skid Ceramic tiles 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.06 Square metre but not exceeding 0.11 Square metre in floor etc, set and jointed in neat cement slurry and pointed in coloured cement to match as in floor over 20mm thick screed bed in CM (1:6) complete all as specified & directed.
Material and labour Glazed Ceramic Coloured tiles 300 x200x 7mm thick as in Dado/Skirting/Steps etc set and jointed in neat cement slurry and pointed in coloured cement to match all as specified and directed.
Supply and fix Aluminium anodised (minimum anodisation is 15 microns) Door / window / Ventilator/partition frames and shutters (02 Nos glazed & gauzed), side hung type, without sash bars, standard aluminium grills, necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, handles, locking arrangements etc., complete with standard aluminium sections, complete all as specified and as directed by Engineer-in-charge.(Aluminium section shall be of make Jindal/Hindalco/ Indalco). (Note:- Weight of various Aluminium sections handles and locking arrangements shall only be considered for measurement for payment. However cost of rubber packing given in the item shall be deemed to be included in the rate quoted. Glass panels, prelaminated particle boards, aluminium wire cloth as applicable will be measured and paid separately as supplied only).
Supply and fix Solid PVC door frame of size 50mmx47mm made out of 5mm wooden grain printed PVC sheet, edges will be painted to match with printed sheet, reinforced with MS square tube & fixing in opening.
Supply and fix Factory made solid panel PVC door shutter 30mm thick (stiles) consisting of frame made out of MS Tubes for top & bottom rails, MS frame shall be covered with heat moulded wooden grain printed PVC sheet and 5mm thick x 15mm wide PVC sheet beading used inside stiles & rails and decorative PVC beading of 10mmx10mm used instead of exposed portion of PVC sheet beading.
Supply and fix 100 Butt hinges extruded aluminium alloy, anodised. With galvanised mild steel hinge pin , anodised and fixed type B-21
Supply and fix 200mm Aluminium anodised barrel tower bolts of extruded sections.
Supply and fix 150mm Extruded aluminium alloy handles, fabricated type, anodised.
Supply and fix 1mm thick Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 all as specified and directed
Supply and fix mild steel Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges large hasps and staples; chains; handmade sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 all as specified and directed
Supply and fix Mild steel Bolts Exceeding 12mm n. exceeding 20mm dia, purpose made with Hexagonal or Square head one end and screwed the other, or Screw both ends, each screwed end to be fitted with Washers and one hexagonal or Square nut, Exceeding 30 cm long all as specified and directed.
Material and labour For preparing steel/ Iron surfaces of any description exc 10cm Width or Girth and applying two coats of synthetic enamel paint over one coat of Redoxide primer complete all specified and directed.
Supply and fix 15mm Bore Stop Valves / Angle Cock Fancy Type Chromium plated cast copper alloy screwed down high pressure with crutch or butterfly handles screwed both ends.
Supply and fix 2 Way Bib Cock Double handle with flange 15 mm bore cast copper alloy Chromium plated with wall flang, screwed down, screwed for pipes. (Make:- Prayag Cat No -8312 or Equivalent)
Supply and fix Hand Shower (Health Faucet) 1 Meter Long Flexible Tube & Hook. (Make:- Jaquar Cat No ALD CHR -585)
Supply and fix looking mirror Bevelled Edge 600mmx450mm mounted on 6mm thick AC building board or commercial ply wood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed by the Engineer -in- charge..
Supply and fix Gun Metal Gate valves 20 mm dia with iron wheel head screwed both ends for iron pipes complete all as specified & directed.
Supply and fix Chromium Plated Steel Grating of 100mm size complete all as specified & directed .
Supply and fix Vitreous China Wash down water closet pan pedestal pattern (EWC) white in colour with and incl plastic water seat and cover white closed pattern with flat bottom and cover and MS chromium plated hinging device incl connection to outgoing pipe and flushing pipe with connecting Accessories complete all as specified & directed by Engineer-in-charge.
Supply and fix PVC low level flushing cistern 10 litres capacity with inlet ball valve, float and handles including brackets all as specified & directed by Engineer-in-charge.
Supply and fix Vitreous China Wash hand basin, white flat back size 550x400 mm including brackets(including Pillar Tap 15 mm bore Chromium plated cast copper alloy with capstan heads, 32 mm waste coupling brass chromium plated suitable for wash hand basins, with long screwed shanks and fly nuts & PVC waste pipe) all as specified & directed by Engineer-in-charge.
Supply and fix PVC flexible connections 15 mm dia 450 mm long with brass check nuts .
Supply and fix 100 mm CI Floor trap with grating incl jointing to waste pipe fixed in cement concrete type B1 (1:2:4).
Supply and fix 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to walls heights up to3.5M or laid in floor.
Supply and fix 200 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to walls heights up to 20M.
S & laying for RCC hume pipe 150 mm bore, class NP2, laid and jointed complete with collars complete all as specified and directed.
Supplying and laying of CPVC pipes of following sizes SDR 11 & Plain CPVC SDR 11 fittings in walls and ceilings or in floors complete all as specified.
Supplying and laying of CPVC pipes of following sizes SDR 11 & Plain CPVC SDR 11 fittings in trenches / surface complete all as specified.
Supply install &commissioning of vehicle washing plant of Discharge minimum 26.3 LPM, minimum delivery per gun 11.5 LPM, two number of guns, one number of plunger, operating pressure 22 kgf/cm2, motor power min of 3 HP ,350 RPM including suitable capacity of DOL Starter all as specified and as directed. Make :ATS ELGI or equalent
Supply and fix CPVC ball valves of following size
Material and labour for cutting of existing main water line of dia 80/100 mm and inserting suitable size Tee for taking out water line of dia 40/50 mm to the proposed site including lead joints if required all as specified and as directed by Engineer -in- Charge. Note : Quoted Rate deemed to be inclusive of rate of GI pipe line of dia 50/40 mm of length upto 2m & its accessories if required at site for taking out connection complete.
Supply and fix Rotational moulded polyethylene water storage tanks of following capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I
(a) 500 Litres
(a) 1000 Litres
Supply and fix Ball brass valves of following size, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed
Material and labour For Point wiring complete with proper colour coding using, 1100 Volts grade, 1.5 Sqmm, PVC insulated FRLS, unsheathed wire with multi stranded copper conductor confirming to IS-694, Part II, ISI marked and including PVC non-metallic rigid conduit with ISI marked with all accessories concealed in wall/celling/floor/roof etc, sunk pressed steel not less than 2 mm thick, 50 mm deep terminal boxes with 3mm thick ISI marked plastic laminated sheet top cover fastened with chromium plated brass screws including 1.5 Sqmm, PVC insulated, FRLS, unsheathed, 1100 Volts Multistranded copper conductor green colour as continuous earth wire connected to common earth dolly all as specified and directed for One light/E/fan point controlled by one switch.
All as per item No 82 here in before One 3 pin switch socket outlet point 5 amps on independent board.
All as per item at sl No.82 here in before but with copper conductor cable for one 3 pin socket outlet, 15 amps independent, with cable 4 Sqmm size and 4 Sqmm earth continuity conductor, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix, Switch piano, flush button, single pole, ISI marked, one way 5 Amps 240 volts.
Supply and fix switch socket outlet 3 & 2 pin (mult pin) 5 amps flush/box type, complete all as specified and as dircted by Engineer-in-Charge
Supply and fix switch socket outlet, 2 in 1, 3 pin 15 and 5 amps, controlled by one switch flush/box type complete all as specified and as directed by Engineer-in-Charge.
Material and labour for ceiling rose surface Bakelite 65 x 50mm 3 terminal complete all as specified and directed.
Supply and fixing energy efficient LED Smart bright batten 22 watt fitting 4ft in length nano diffuser technology to ensure minimum loss in light transmitted, long life of over 30000 hours including lamp and connecting with twin core sheathed cable from fitting to ceiling rose all as specified and as directed.
Supply and fixing energy efficient LED Smart bright batten 10 watt fitting 2ft in length nano diffuser technology to ensure minimum loss in light transmitted, long life of over 25000 hours including lamp and connecting with twin core sheathed cable from fitting to ceiling rose all as specified and as directed.
Supply and fix Street light New generation energy saving & environmental friendly long life versatile pressure dia cast aluminium IP65 road way luminaire with high power LEDs 25w as light and electronic driver complete all as per with necessary brackets (made out of 25 mm bore GI light grade pipe approx. 0.6 M long) nuts, bolts etc to be fixed as on walls complete as directed.
Supply and fix exhaust fan suitable for on working of AC 230 V ,50 Hz 300 mm sweep 1400 RPM, with heavy duty motor ,incl louvers complete all as specified
Supply and fix metal enclosure distribution board SPN, 4 way 240 volts, with 200 amps rated bus bar, with IP 42 protection and double door, suitable for mounting MCBs, including taking down old MCB/DB, complete all as specified and as directed by Engineer-in-Charge incoming & Outgoing connections from the DB shall be provided with proper lugs/thimbles etc...
Supply and fix MCB single pole 240 volts, 0.5 to 32 amps complete all as specified and as directed by Engineer-in-Charge
Supply and fix MCB SPN, 240 volts, 6 to 32 amps C series complete all as specified and as directed by Engineer-in-Charge
Material and labour Earthing with 600x600x6.3mm galvanised steel earth plate electrode buried vertically in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the plate at a depth of not less than 1.5m below ground level, connected to and including G.I. wire 4mm dia by means of bolts, nuts all as shown in electrical Plate No.3 connected to earthing test point all as specified or indicated including testing on completion.
Material and labour Earthing with galvanised steel earth plate electrode 60 cm x 60 cm x6 mm hick, buried directly in ground (earth pit not less than 2.25 metre below normal ground level) with top edge of earth plate not less than 1.5 metre below normal ground level connected to main earth lead GI strip 32x6 mm and connected by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of MES Schedule Part I 1991, GI earh lead protected by GI pipe 40 mm dia light grade, providing and connected to earth test point with & including necessary excavation & earth works in any type of soil, returning filling, disposal of surplus soil to 50 metre, filing with mixture of charcoal and common salt upto 15 cm above top edge of earth plate, pit of PCC 1:2:4 with precast cover of RCC 1:2:4, watering arrangement with GI funnel, 20 mm dia GI medium grade watering pipe, earth test point, commissioning & testing complete. (Note: Main earth lead beyond 7.5 metre measured and paid for separately.)
Supply and lay un-reinforced precast concrete cable cover , class , LV , Type 1 flat size 250 x 150 x 40 mm laid dry in trenches over underground cables, embossed with "ELECTRIC" on the top surface complete all as specified and as directed
Supply and Lay Steel tubes medium grade 40 mm outer dia of ISI Marked as per IS-1239 part-I 2004 galvanised with all fittings and fixed complete to wall and ceilings, on pole or laid in floor or in trenches etc complete all as specified and directed
Supply and Lay Steel tubes medium grade of 25 mm dia with ISI Marked as per IS-1239 part-I 2004 galvanised with all fittings and fixed complete to wall and ceilings, on pole or laid in floor or in trenches etc. complete all as specified and directed
Supply and lay cable XLPE Insulated screened, PVC bedded, galvanized steel strip or wire armored, electric power cables 4 core 10 Sqmm 1100 Volts grade with stranded aluminium conductors all as per IS -7098(Part-1 1977) and Part 2- 1985 in trench / wall / floor as specified by Eng-In-Charge
Supply and lay cable XLPE Insulated screened, PVC bedded, unarmored, electric power cables 4 core 6 Sqmm1100 Volts grade with stranded copper conductors all as per IS in trench / wall / floor all as specified by Eng-In-Charge
Supply, fix, install and testing of high speed Monobloc pump set suitable for 415 V, 3 phase, 18M minimum head ,7.5 LPS minimum foundation as per manufacturer recommendations with suitable rated Starter complete all as specified and as directed by Engineer-in- Charge. Make :Kirloskar Note:- 1. Suction &delivery pipe shall be GI of suitable dia (length appr 6m each ) as per size suction/delivery end of the pump including connected fittings like tappers/reducer/bends etc required to connect the lines to pumpset, rate for the same deemed to be included in the quoted rate 2.Rate deemed to be inclusive of motor cover .
Material and labour for CI foot valve conforming to IS:4038, of size 50mm dia complete all as specified and as directed
Supply and fix Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of following dia all as specified and as directed
(a) 40 mm dia
(b) 25 mm dia
Supply and fix pole junction box sheet moulded compound (SMC) type with hinged door and locking arrangement of siz 300x200x105 mm internal for accommodating One Nos TPN MCB 32 Amps 10 KA, 4 nos bus bar of capacity 32 Amps with DIN rail including nuts and bolts and connecting up complete & necessary arrangement for holding sintex box on ground all as specified and directed. Note : Rate deemed to be inclusive of any civil works like PCC required at site to hold the box on ground and TPN MCB 32 A
Supply and fix Outdoor type LT sheet metal enclosure of suitable size for accommodating two Nos DOL starter including necessary arrangement for holding box on ground all as specified and directed. Note: Rate deemed to be inclusive of any civil works like PCC required at site to hold the box on ground & necessary arrangement for fixing starters inside enclosure.
Supply and fix TPN distribution board factory made double door flush type as per IS 8623 made from sheet metal duly powder coated for single phase outgoing and three phase incomer, with 100 Amps rated bus bar, 415 V, 4 way flush with wall complete with all accessories all as specified and directed by Engineer-in-Charge.
Supply and fixing ,connecting and testing MCB three pole (MCB TP) 440 volts, of capacity 40 Amps, 10 kA C curve complete all as specified and directed.
Supply and fixing, connecting and testing MCB three pole and neutral (MCB TPN) 440 volts, of capacity 40 Amps, 10 KA in the existing/proposed LT panel/DB all as specified and as directed by Engineer-In-Charge. Note : Rate deemed to be included of any alteration works required to fit the MCB in the panel/DB
Supply and fix pole junction box sheet moulded compound (SMC) type with hinged door and locking arrangement of siz 140x140x100mm internal comprising of 4 nos bus bar of capacity 63 Amps one No. earthing terminal including nuts and bolts and connecting up complete MS clamps fabricated from 25x3mm MS flat iron , space & provision for fitting TPN DB including necessary arrangement including foundation for holding sintex box on ground all as specified and directed.
Supply and lay steel tubes light grade 40mm outer dia of ISI marked as per IS-1239 part-I 2004 galvanised with all fitting and fixed complete to wall and ceiling, on pole or laid in floor or in trenches etc for protection of underground cables complete all as specified and directed.
Priya construction
Kathir Marketing Services
SUMAN
RADHA GOVIND CONSTRUCTION
S.K.ENTERPRISES
DISHA ENTERPRISES
DAS AND SONS CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .