Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.8 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹38.1 L+₹32,653.30 (0.86%)Rejected-Finance CHHANI NANAK TEHSIL MANDAL PHALLAIN JAMMU J K 180003 | JAMMU | JAMMU | J K | 180003 | L2 | Rejected-Finance L2 | |
| 3 | L3₹38.3 L+₹55,184.72 (1.46%)Rejected-Finance H NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR 144 022 PUNJAB | JALANDHAR | JALANDHAR | PUNJAB | 144022 | L3 | Rejected-Finance L3 | |
| 4 | L4₹38.8 L+₹1.1 L (2.84%)Rejected-Finance NEAR PARDEEP MEDICAL HALL DEEP NAGAR JALANDHAR CANTT JALANDHAR PUNJAB 144005 | JALANDHAR | PUNJAB | 144005 | L4 | Rejected-Finance L4 | |
| 5 | L5₹40.0 L+₹2.3 L (5.96%)Rejected-Finance INDEX NO E 29 CWE JRC 352 3 GURU NANAK PURA EAST JALANDHAR CITY PIN 144001 | JALANDHAR CITY | JALANDHAR | PUNJAB | 144001 | L5 | Rejected-Finance L5 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
30 May 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (East) Jalandhar Cantt
Garrison Engineer (East) Jalandhar Cantt
REPAIR TO LT ELECTRIC SUPPLY AT OFFRS MD ACCN UNDER GE (EAST) JALANDHAR CANTT
2022_MES_506263_2
GE/JULL/ET-69/2021-22
Open Tender
Civil Works
Item Rate
273 days
Jalandhar Cantt
As per tender documents
8 documents required · 8 mandatory
₹500
Garrison Engineer (East) Jalandhar Cantt
₹90,000
Yes
19 Jul 2022
9 May 2022
6 Jun 2022
9 May 2022
30 May 2022
18 May 2022
Amount
Taking down old unserviceable LT underground cable of any cross sectional area, any type, any make by opening connections and joints including pipes, bricks etc of any description laid in trenches or fixed with walls/ poles, segregated serviceable bricks/ cable cover, cables etc and keep in safe custody for reuse, complete all as specified and directed. Note : Earthwork will be measured and paid under appropriate items
Taking down old unserviceable wall panels/ distribution board complete all as specified and directed.
Supplying, laying, jointing and testing LT underground cable XLPE insulated, PVC Sheathed, galvanized steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 1100 volts grade earthed system of size 35 sqmm 3½ core conforming to IS laid in trenches, in floor, in duct, through pipes or along the pole complete all as specified and directed.
Laying only in trenches/ clamped with wall/ on floor/ in ducts for replacement of LT cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables, 1100 volts grade with stranded aluminium conductor of size 35 sqmm 3.5 core complete all as specified and directed Notes : (a) Earthworks, sand cushioning, etc will be measured and paid under appropriate items. (b) The quoted rate includes the cost of collecting the cables from MES store yard or other site as directed by JE/ Engineer-in-Charge and shifting to work site where required.
All as per item No. 4.00 but 95 sqmm 3.5 core
All as per item No. 4.00 but 150 sqmm 3.5 core
M&L submain wiring with PVC insulated cable copper conductor FRLS four single core 6 Sqmm drawn through PVC rigid non-metallic concealed/ conduit including earth continuity FRLS copper conductor 6 Sqmm PVC insulated with green insulation including taking down complete including making good the disturbed surface as per existing specifications all as specified and directed. Note : Four runs of cable 6 Sqmm, two run of 6 Sqmm with PVC rigid conduit shall be measured as one unit RM.
Excavation in trenches in soft/ loose soil n. exc. 1.50 mtr wide and n. exc. 1.50 mtr in depth for laying of cables and getting out complete all as specified and directed.
Returning filling in, including spreading, levelling, watering and well ramming in layers n.exc. 25 cm thick each layer complete all as specified and directed.
Removal of surplus spoil to a distance n. exc. 50 mtr and depositing where directed at a level n. exc. 1.5 mtr above the starting point complete all as specified and directed.
Material and labour sand for cushioning with 8cm thick layer before laying of cable and 15cm thick layer after laying of cable in trenches complete all as specified and directed.
Supply & laying old size sub class 'B' bricks laid flat in trenches over the cable with the length of brick perpendicular to the direction of cable length, adjacent/ abutting each other complete all as specified and directed.
Laying only cable cover/ brick, laid breadth wise along the length of cable laid in trenches complete all as specified and directed. Note : Serviceable cable cover/ bricks obtained from Item No. 01 here-in-before.
Material and labour for Boring hole under the road/ pavement/ hard standing and inserting HDPE pipe of 100mm at a depth not less than one metre below ground level complete all as specified & directed. Note: HDPE pipe 100mm shall be included and paid in quoted rate
Supply and fixing powder coated sheet metal enclosure indoor type of size 1200mm x 1000mm x 225mm minimum made out of 2mm thick CRCA sheet having independent compartments-04 Nos suitable for three phase smart energy meters of size as approved by Engr-in-Charge and MCB’s provided with front hinged shutters with locking arrangements and clear glass to visualize the meter reading without opening the compartment with sufficient working space in compartment; duly prewired with single core PVC insulated and sheathed FRLS stranded copper conductor wire of suitable size from bus bar to all meter compartments duly crimped with copper thimbles, duly powder coated having sufficient number of cut outs with cable glands for suitable size of LT XLPE/ PVC cable entry at bottom complete all as specified and directed and consisting with the following:- (a) Bus bar for 3 phase 4 wire system of 4 x 250 Amps rated insulated copper strip mounted on resin cast insulators in independent compartment having front open able shutter - One Set.B27 (b) MCCB, four pole, 415 volts, 125 Amps, 16 KA with adjustable over current and short circuit, inbuilt in stantaneous protection, ICS=ICU=100% including spreader links on both sides-One No.
Supply and fixing TPN DB made out of sheet steel enclosure with copper bus bar, double door with IP 43 protection, epoxy coated/ powder coated inside and outside TPN, 4 way with blanking strip/dummy plates complete as cat part No. 507670 of legrand/ cat part No A9HTND04 of schneider/ cat part No 8GB32202RC04 of SIEMENS as specified and directed
Material and labour for TPN MCB, 240 Volts, 50 Hz, having rupturing capacity 10 KA, of rating 32 Amps complete as Dx3 range of legrand/ betagard 5SL series of siemens/acti 9 range of schneider, complete all as specified and directed.
Supply and fixing MCB SP 6-32 Amps complete as Dx3 range of legrand/ betagard 5SL series of siemens/acti 9 range of schneider, 10 KA, B-curve complete all as specified and directed.
Material and labour for GI protection pipe light grade 50mm dia bore for protection of cables complete all as specified and directed.
Material and labour in replacement earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of the plate at a depth not less than 1.5 metre below normal ground level, connected with and including GI wire 4mm in and including GI pipe 15mm bore light grade as protection pipe (from top of earth plate up to the test point) by means of GI bolts, nuts, check nuts and washers of GI and thimbles, earth plate surrounded by packed layers of charcoal dust and common salt 15cm thick, all around including top and bottom and watering pipe 20mm bore of GI pipe light grade with funnel and wire mesh, PCC chamber of size 300 x 300 x 300mm (top of chamber minimum 15 cm above the normal ground level with MS iron frame on top made of 30x30x3 mm MS angle iron duty painted (1:3:6) using 20mm graded stone aggregate and 50mm thick RCC cover in (1:2:4) type B-1 using 20mm graded crushed stone aggregate with 1 Nos MS handles of 8mm dia including necessary excavation/ earth work in any type of soil/rock and as shown in Electrical plate No. 3 of SSR Part-I (2009) testing on completion complete all as specified and directed. Note: If result is not achieved satisfactory, contractor will have to do re-earthing at his own cost. Nothing shall be paid extra on this account.
KULDEEP SINGH
UNITED ENGINEERING CORPORATION
GULSHAN SINGH GHAI AND SON
Northern cable fault locatoers
RAVI KUMAR
Bains Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .