Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹3.2 LAccepted-AOC | L-1 | Accepted-AOC Lowest qualified bidder. Hence being awarded | |
| 2 | L-2₹2.8 L+₹8,541.80 (3.15%)Rejected-AOC BALAJI WARD BALLARPUR 442701 | BALLARPUR | CHANDRAPUR | MAHARASHTRA | 442701 | L-2 | Rejected-AOC Not a qualified L1 bidder | |
| 3 | L-3₹2.9 L+₹18,210.55 (6.72%)Rejected-AOC SHIVNICHOR NANDGAON PODE RAJURA DIST CHANDRAPUR 442905 | RAJURA | CHANDRAPUR | MAHARASHTRA | 442905 | L-3 | Rejected-AOC Not a qualified L1 bidder |
Tender Value
₹2.9 L
EMD Value
₹3,700
Closing Date
5 Feb 2024, 4:30 pmClosed
GNVS shree Harsha
office of Gouri Sub Area, Rajura
Shifting of bore well at CHP at Gouri Pouni A under Gouri Sub Area
2024_WCL_300235_1
wcl-ba3612-civ-19-2023-24
Open Tender
Civil Works - Others
Item Rate
45 days
Gouri Pouni (A) OCM
Please refer Tender documents.
4 documents required · 4 mandatory
₹3,700
Yes
9 Mar 2024
2 Feb 2024
6 Feb 2024
2 Feb 2024
5 Feb 2024
2 Feb 2024
2 Feb 2024 - 4 Feb 2024
Amount
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level.All types of soil 300 mm/dia
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level.Rocky strata including Boulders 300 mm dia
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in charge. 200 mm nominal size dia
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
lifting of under breakdown submerssible pump with motor and 50 mm GI pipe from borewell and transporting the same for repairing purpose as per the instruction of engg in charge
lowering of repaired submerssible pump with motor and 50mm GI pipe with all accessories by transpoting the same upto site as per the instruction of engg in charge
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :50 to 80 mm nominal bore
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming 200 mm nominal size dia
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work50 mm dia nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end)50 mm nominal bore :
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
Supplying & erecting flat flexible 3 core 6 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.
Supplying & erecting automatic control panel for 3 Ph, 415 volt, A.C. Submersible/centrifugal pump set up to 7.5 HP - 10 H.P. consisting of DOL starter having relay range 28-42 AMP,S.P.P., Combined ammeter/voltmeter,phase indicating lamp enclosed in CRCA powder coated Vibration proofenclosure with IP 54 protection. Control Panel should offer single phasing, phasereversal, phase imbalance etc.
Total impact of GST for the purpose of CTC
M A SHEIKH
SANTOSH BHONGARE
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .