Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹17.9 LAdmitted-Finance | L1 | Admitted-Finance | ||
| 2 | L2₹18.3 L+₹43,960.19 (2.46%)Admitted-Finance 272 VIKAS KUNJ VIKAS PURI NEW DELHI 110018 | WEST | DELHI | 110018 | L2 | Admitted-Finance | ||
| 3 | L3₹20.0 L+₹2.1 L (11.7%)Admitted-Finance 21 10 SHOP NO 1 SECTOR 3 MAHABINI DELHI 110085 | NORTH WEST | DELHI | 110085 | L3 | Admitted-Finance | ||
| 4 | L4₹20.1 L+₹2.2 L (12.5%)Admitted-Finance NONE | L4 | Admitted-Finance |
Tender Value
₹22.7 L
EMD Value
₹45,320
Closing Date
17 Feb 2026, 3:00 pmClosed
EE(E)
North Electrical Division, PWD, Dr. BSA Hospital, Sector -6, Rohini, Delhi - 110085
Maintenance Electrical consumption charges of street lighting on PWD Roads under North Electrical Division. SH Replacement of defective street lights from Mukarba Chowk to Wazirabad and other allied electrical work
2026_PWD_286608_1
103/NED/PWD/M-352/2025-26
Open Tender
Electrical Works
Percentage
45 days
as per nit
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹45,320
Yes
17 Feb 2026
10 Feb 2026
17 Feb 2026
10 Feb 2026
17 Feb 2026
10 Feb 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66, IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per
ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
a) 200 watt | 200 | Each | 4,689 | ₹9,37,800 |
| 2 | SITC of Single Section GI Octagonal Pole of 12 mtr. height made from 4mm thick HT Steel plate, having minimum bottom dia of 200 mm. & top dia of 100 mm. complete with window with hinged cover at a height of 2.5 mtrs. from the base for cable termination block etc. and galvanized base plate of minimum size 320mm X 320mm X 20 mm thick on existing cement concrete pedestal as required. i/c supplying and fixing of the following in the window box provided for cable termination i/c making connection with suitable size aluminium lugs and testing commissioning etc. as reqd.:-
a) Supplying and fixing 6 mm thick laminated mounted sheet inside the window mounted on and i/c providing and welding 3 nos. G.I strips 4mm thick of suitable length and having suitable size tapped holes - 10nos. as reqd.
b) Supplying and fixing of 63 Amp terminal block suitable for 25sq.mm conductor -4 nos. & shorting links – 5nos. on DIN channel i/c pdg. and fixing DIN channel of suitable length – 2 nos. on the existing laminated sheet.
c) Supplying and fixing 6 Amp, SPMCB, ‘C’ Characteristics Curve - 2 No. Earth stud-2Nos. welded at suitable height 2 nos. washers, springs washers & nuts.
d) Cable support clamp suitable for 4 Nos of 4x25sqmm cable.
e) The foundation bolts shall have check nuts and nuts shall be welded with the bolts. The nut-bolts shall be covered with cement concrete of ratio 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) upto a height of 30 cm above foundation. | 6 | Job | 32,743 | ₹1,96,458 |
| 3 | Fabrication, Designing, Supplying & Fixing of hot dip Galvanized arm bracket of suitable length single/double over hang with suitable size bolt etc. as reqd. (design approved by Engineer-in-charge). | 20 | Kg | 125 | ₹2,500 |
| 4 | Supplying and fixing 4 Nos. 24 mm(minimum) dia X 750 mm (minimum) long GI foundation bolts (EN8 grade) with nuts, washer including 2 Nos. template of 4 mm. thick size 320 X 320 mm. with 4 Nos. 28 mm. dia holes, to match with PCD of Pole base plate as reqd | 6 | Job | 2,687 | ₹16,122 |
| 5 | Providing and laying in position 1:2:4 reinforced cement concrete foundation of size 750 mm.(L) X 750 mm. wide and 1800 mm. deep i/c excavation of earth, providing cutting, bending and placing in position, Steel reinforcement of cold twisted bars of 12 mm. dia- 1960mm long (approx)- 8 Nos. and reinforcement ring of cold twisted bar of 8mm dia - 2900mm (approx) - 13nos. (with 150mm spacing) for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete as required with positioning of foundation bolts (as per above item) and providing 90 mm. (O.D) DWC, HDPE Pipe minimum 1 meter for cable entry & exit as required or Size as per pole manufacturer foundation design. (For 12 mtrs. pole) | 6 | Job | 13,497 | ₹80,982 |
| 6 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
a) Upto 35 sq. mm | 300 | Mtr | 47 | ₹14,100 |
| 7 | Laying of XLPE insulated PVC sheathed aluminium conductor 1.1 KV grade armoured cable conforming to IS 7908 (Part - I) as amended up to date of following sizes in over head at a height of upto 12 mtrs on busy road between street light poles with the help of Hydra etc as required.
Upto 35 sq.mm overhead with 10 SWG GI wire tied with suitable size MS clamp | 600 | Mtr | 180 | ₹1,08,000 |
| 8 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
a) 63 mm dia (OD-63 mm & ID-51 mm nominal) | 300 | Mtr | 289 | ₹86,700 |
| 9 | Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
a) 200 watt | 15 | Each | 4,550 | ₹68,250 |
| 10 | Supplying of one number PVC insulated and PVC sheathed / XLPE sheathed aluminium Conductor armoured power cable of 1.1 kV grade of following size etc complete as reqd.
a) 4 x 25 sqmm | 100 | Mtr | 615 | ₹61,500 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.13 MB
BOQ_379451.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .