| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.2 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹29.0 L+₹11,871 (0.41%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹32.1 L+₹3.3 L (11.4%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹32.5 L+₹3.7 L (12.7%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹32.9 L+₹4.0 L (14.0%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
12 Mar 2022, 6:00 pmClosed
GE (AF) Srianagar
Garrison Engineer (AF) Srinagar Air Force Station Srinagar-190007
CERTAIN REPAIR / MAINTENANCE OF B/R, E/M WORKS, CLEANING / REPAIR OF SEWAGE SYSTEM AND CAMOUFLAGING PAINTING AT BB CANTT AND AOR OF GE(AF) SRINAGAR
2022_MES_505716_1
GE (AF) SGR-03/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE (AF) SRINAGAR
As per Tender Documents
10 documents required · 10 mandatory
₹500
GE (AF) SRINAGAR
₹90,000
Yes
28 Jun 2022
4 Feb 2022
14 Mar 2022
4 Feb 2022
12 Mar 2022
18 Feb 2022
Amount
Dismantling of Plain or corrugated steel sheeting any gauge, thickness, including Nainital or similar pattern roof coverings including ridges, hips, valleys and flashings etc complete all as specified and as directed by Engineer-in-Charge.
S&F Galvanised, corrugated mild steel sheeting 0.63 mm thick with two corrugations side lap, fixed with hooks L type or J type or cranked hook bolts , in roofs, walls etc with grade of zinc coating 275, Complete.
All as per item No 02 but except Sheets using sheet retrived vide item No 01 above
S & F Plain, galvanised, mild steel sheeting, 0.63 mm thick in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275, Complete.
M&L for Preparation of new zinc (or galvanised) steel and iron roof surfaces of any description over 10 cm width or girth to receive painting, by coating with mordant solution including washing and cleaning, etc and applying two coat of synthetic enamel paint over one coat red oxide primer complete all as specified and directed by Engineer-in-Charge
Demolition of floor, hearth or wall tiling or stone slab laid, bedded & pointed in any mortar including demolition of cement mortar bedding or backing coat, including rubbish off the premises, all as specified..
M&L for granite (of any type) work (table rubbed and polished) 20 mm thick as in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite laid over screed bed in cm 1:4, complete.
M&L 15 mm thick screed or bedding layer in cement mortar (1:4) for laying floor finishes, complete all as specified.
M&L for 10 mm thick rendring / backing coat in cement mortar (1:4) to receive wall tiles, complete all as specified.
M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, laid over screed bed.
M&L for coloured glazed ceramic tiles in vertical surfaces of size 450 x 300 x 6-7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match, complete all as specified.
Demolition of cement concrete (unreinforced) in ground floor and in paving n exc 15 cm thickness (below or above ground level), complete all as specified.
M& L for 75 mm thick Cement concrete type C2, 1:3:6 (using 40 mm graded stone aggregate) in hard standing / pavings / plinth protections, finished even and smooth without using extra cement, Complete.
M&L for 75 mm thick cement concrete 1:4:8, type D-2,(using 40 mm graded stone aggregate) as in Sub base for path / flooring complete all as specified and as directed.
Demolition of Brickwork or stone/boulder masonry, build in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles complete.
M&L for stone masonary Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in CM 1:6
All as per item No 16 above but except stone, using old stone retrived from item No 16 above.
M&L for Brick work with sub class 'B' bricks straight or curved on plan exc 6 m mean radius with old size bricks built in cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceble wooden panneling / boarding complete with frame work.
M&L for Wooden panelling of second class softwood 12 mm thick with tongue and groove joint fixed in any position over and including wooden framework in second class softwood with plain fillets square or sectional area exc 13 Sqcm and n exc 25 Sqcm at n exc 90 cm centre to centre in both direction and including two or more coat of french polishing on all the exposed surfaces wooden panelling including taking down existing electrical fittings and re-fixing the same, complete.
Taking down cement plaster of any description on brick or stone masonary wall , etc including racking out joints, hacking for key, scrubbing down with water etc, all as specified.
M&L for Rendering 15 mm thick in CM 1:4 on stone masonary wall surface and finishing even and smooth without using extra cement complete
M&L for Rendering 15 mm thick in cement and sand mortar 1:4 on brick work or cement concrete surfaces of walls including finishing the surface even and smooth with using extra cement and mixing only integral water proofing compound as per manufacturer instruction complete all as specified and as directed by Engineer-in-Charge. Note:- WPC will be measured and paid seperately.
Supply only integral water proofing compound.
M&L for applying 2 mm thick cement base wall care putty on plastered surface of wall, and making the surafce even & smooth for reciving distemper / paint of any descreption all as specified & directed.
M&L for preparation of new plastered surfaces of wall and applying two coats of oil bound distemper over one coat of primer all as specified and directed. Note:- Cement base wall care putty where ever directed will be applied and will be measured & paid seperatly
Taking up or down steel tubing and connections, 15 mm bore fixed on walls, floors or ceiling etc complete all as specified and as directed by Engineer-in-Charge.
S&F 15 mm bore tubes, 'medium grade', galvanised, with all fitting; ( such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs, unions etc) and fixed to wall / ceiling with clips, wall hooks, wooden plugs or laid in floors including screwing and waste and for forged bends on piping as required, complete all as specified.
Taking up or down steel tubing and connections, 20 mm bore fixed on walls, floors or ceiling etc complete all as specified and as directed by Engineer-in-Charge.
S&F 20 mm bore tubes, 'medium grade', galvanised, with all fitting; ( such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs, unions etc) and fixed to wall / ceiling with clips, wall hooks, wooden plugs or laid in floors including screwing and waste and for forged bends on piping as required, complete all as specified.
M&L for Lagging to pipes 20 mm bore used in external water supply or plumbing all around with 25 mm thick bonded mineral wool pre-formed ‘SNAP ON’ pipe sections of density 144 Kg /Cum conforming to IS 9842 provided with chicken mesh wire netting 25 gauge 20 mm mesh complete including taking down of old lagging all as specified and directed by Engineer-in-Charge
Supply and fix in repairs white vitreous china squatting pan ‘ORISSA’ pattern of size 580 mm x 440 mm white with integral foot rests with ‘P’ or ‘S’ trap, front or back inlet including all connection and provision of lime concrete base complete all as specified and as directed..
S&F in repairs white Vitreous china wash down water closet (pedestal pattern) with fixing bolt, Plastic water closet seat cover, white, closed pattern with flat bottom, and cover with aluminised hinging device, brass chromium plated Jet shower with one meter long flexible pipe including all connection complete.
S&F in repair PVC low level flushing cistern, valveless, syphonic action type, double push botton, 10 litres capacity with inlet, ball valve float and handle with and including brackets & PVC bend pipe 32 mm dia of required length and making connection complete complete all as specified.
Supply and fix in repair white vitreous China wash hand basin (Flat back) of size 630 x 450 mm fixed on and including new brackets complete including, 32 mm size brass chromium plated waste coupling, chain and plug and porcelain stopper, etc complete.
S&F in repair brass chromium plated Jet Spray of Standard size for EWC alongwith CP connection and all fittings as fixed, complete all as specified and directed by Engineer-in-Charge.
S&F in repair PVC connections 15 mm size with PTMT nuts of length 450 mm complete.
S&F in repair PVC waste pipe flexible for WHB of 32 mm size complete.
S&F in repairs for 15 mm size bib taps fancy type, cast copper alloy chromium plated, with capston head, screwed down, screwed for iron pipe or for brass ferrule and fixed, all as specified.
S & F in repairs 15 mm size wall mixer for mixing hot & cold water, cast copper alloy chromium plated with capstan heads, high pressure, with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed by Engineer-in-Charge.
S & F in repairs 15 mm size central hole basin mixer for mixing hot & cold water, cast copper alloy chromium plated with capstan heads, high pressure, with long screwed shanks and fly nuts, screwed for iron pipe including 450 mm long braided connection pipe complete all as specified and directed by Engineer-in-Charge.
S&F in repair ABS plastic chromium plated Health faucet fixed with spring action and lever along with Flexible hose with brass nut of length 1 m to 1.2 m fitted in the existing water connection in the toilets, Complete all as specified and directed by Engineer-in-Charge.
S&F in repair Glass Shelf of size 500 mm x 125 mm wide with stainless steel wire guard fixed on wall with and including bracket and brass screws and wooden / plastic cleats. Make:- Prayag or equvallent make mention in Appx A.
S & F in repair Corner Glass Shelf of size 300 mm with stainless steel wire guard fixed on wall with and including bracket and brass screws and wooden / plastic cleats. Make:- Prayag or equvallent make mention in Appx A.
S&F in repair Tubular towel rail stainless steel chromium plated 20 mm dia D-type 60 cm long between flanges, including brackets and fixed to walls, complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs, 125 mm dia stainles steel chromium plated grating, fixed in position Complete.
M&L for Complete removal of existing treatment from Plastered surfaces of walls including scraping down smoke soots, moulds, moss and trading oil and greasy spots etc including cornices, pilasters etc and applying two coats of oil bound distemper over one coat of primer complete all as specified and directed by Engineer-in-charge. Note:- Cement base wall care putty where ever directed will be applied and will be measured & paid seperatly
M&L for preparation of old painted wooden surfaces of any description and positions, exc 10cm width or girth and applying one coat of synthetic enamel paint complete.
M & L for preparation of old painted steel surfaces of any description exc 10cm width or girth and applying one coat of synthetic enamel paint in any pattern complete.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads
S&F 3 mm thick sheet glass, ordinary quality and glazing with wooden beads in square or rectangular in section n exc 0.5 sq.m in each pane fixed with beads complete .
S&F in repair galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm fixed with tinned tack or galvanised wire staples or fixed with nails and wooden beads, complete .
Supply & fixed 25 mm thick second class soft wood planed one side & edges tongued and grooved or rebated, fixed wih nail inluding repairs to existing floors in patches, including cutting out, piecing,heading joints etc complete.
S&F 20 mm Stainless steel curtain rod with stainless steel bracket and satinless steel finils, fancy type as approved by GE, as in curtain rods including taking down the old curtains rods complete all as specified and directed by Engineer-In-Charge.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m deep and getting out in any type of soil complete all as specified and directed by Engineer-in-Charge.
Returning filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick using excavated soil complete all as specified and directed by Engineer-in-Charge.
Removal of excavated soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge.
Demolition of Precast cast RCC manhole cover of any descreption set in Cement mortar including removal of debries, complete all as specified and directed.
M&L for cutting & removing 150 mm dia drain pipe from existing manhole and inserting new drain pipe of dia 150 mm, making good disturbed surface & benching with cement concrete 1:2:4 type B-1, complete all as specified & directed.
Demolition and breaking up 150 mm dia bore salt glazed stone were drain pipe including PCC packing under hunching against the sides of pipe bed and complete PCC bedding and removal of debries all specified and directed.
M&L for Concrete bed to 150 mm bore drain pipes including packing under, and haunching against the sides of pipes after they are laid in cement concret 1:3:6 (Nominal mix) type C-2 using 40mm graded stone aggregate and tested, complete all as specified & directed.
M&L for Salt-glazed stoneware drain pipe, grade ‘A’ internal dia of pipe 150 mm, laid in trenches and jointed with cement & sand mortar, complete all as specified & directed.
M&L for PCC 1:4:8 type D 2 using 40mm graded stone aggregate as in foundation, filling, mass concrete complete.
M&L mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia all as specified. Complete.
M&L for Pre cast RCC 1:2:4 type B1 using 20 mm graded stone aggregates as in cover slab for soakage well / manhole and similar works supported on walls and set in cement mortar 1:4 complete. Note:- Reinforcement steel will be measured & paid separately
Cleaning of 100 mm bore underground sewage pipe (Cleaning length n.exc 30 m from manhole to manhole or from manhole to septic tank) including taking off manhole cover and cleaning of manholes of any size and depth and removing waste material / sludge to a distance of n.exc 300 m and burrying in a pit and replacing manhole cover in position after cleaning complete all as specified and directed by Engineer-in-Charge
All as per item No 66 above but 150 mm bore sewage line.
All as per item No 66 above but 200 mm bore sewage line.
Cleaning of blockage WC of pedestal / squatt pattern upto 1st manhole and making the drian pipe of any size full functional by flushing with water to entire satisfaction of engr in charge including cleaning of 1st manhole and removing the waste material / sludge etc to a distance n. exec 300m and burying the same in pits and spreading the area with bleaching powder complete all as specified and directed by engr in charge.
Cleaning of blockage from floor trap of bath room & kitchen etc upto 1st manhole including cleaning of gully / trap and removing the waste material / sludge etc to a distance n. exec 300 m and burying the same in pits and spreading the area with bleaching powder complete all as specified and directed by engr in charge.
Dewatering of septic tank / soakage well of any depth in any position by pumping out and removing outside Military/Defence land by mechanical means (trolley mounted) and burying in pits all as directed including digging of pits in any type of soil and covering pits with earth after absorption of water and including providing and spreading required quantity of bleaching powder around the pit or dispose of waste material as per state protocol including taking down of slab cover and refixing the same CM 1:4 complete all as specified and directed by engineer-in-charge
De-sludging of septic tank of any capacity including connected intercepting chamber, manhole shaft, sludge chamber & filter beds of any description and in any position by pumping out and removing of sludge outside Military/ Defence land by mechanical means (trolly mounted) and burying in pits all as directed including digging of pits in any type of soil and covering pits with earth after filling of sludge and including providing and spearding required qty of bleaching powder or dispose of waste material complete as per state protocol, including taking down of slab cover and placing the same in existing postion complete all as specified and directed by Engineer-in-Charge.
Dismantling of PVC drain pipes, 75/100 mm dia, jointed with rubber ring and taking out from trenches / walls Complete all as specified and directed by Engr-in-charge.
S&F 75 mm outer dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls with clamp complete all as specified and as directed by the Engineer-in-Charge.
S&F 110 mm outer dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls with clamp complete all as specified and as directed by the Engineer-in-Charge.
S&F 75 mm size PVC (SWR) bends of any radius, complete all as specified.
S&F 110 mm size PVC (SWR) bends of any radius, complete all as specified.
S&F 110 mm size PVC bore (SWR) branch piece, single (single Y) equal or unequal, complete all as specified
S&F in repair CI Access door cover for 75 mm bore pipe incl all asseseries complete all as specified and directed by Engineer-in-Charge.
S&F in repair CI Access door cover for 110 mm bore pipe incl all asseseries complete all as specified and directed by Engineer-in-Charge.
M&L for rubbur molded glossy finish Chequered cement concrete tiles of size 30 cm x 30 cm x 25 mm thick, in white cement with pigment, set, jointed in neat cement slurry & pointed in coloured cement, as in floors / path / hardstanding, laid over screed bed complete all as specified and directed.
M&L for preparation of old plastered surfaces of walls including sides and soffits of beams, fascias, parapets etc and applying one coat of cement base paint, colour and tint complete all as specified and directed by Engineer-in-Charge.
M&L for complete removal of existing treatment from old painted surfaces of walls including sides and soffits of beams, fascias, parapets etc and applying two coats of weather proof exterior emulsion paint, over one coat primer colour and tint , complete all as specified and directed by Engineer-in-Charge.
Taking down copper / aluminium point wiring (light,fan,socket & power) complet incl fixtures and fittings such as switches,ceiling rose,pendent holdes,regulators,sockets,light fitting etc and making good disturbed surface of wall, floor etc complete as specified and directed.
Material & Labour for point wiring for one light / Fan point controlled by one, one way switch complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable 1100 volts grade ISI marked drawn and including PVC rigid conduit not less than 20 mm dia, including all accessories like bend, tees, junction boxes etc., 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable as a earth wire connected to common earth dolly, etc and including sunken type pressed steel terminal box of suitable size for modular type switch with cover plate & frame complete. Note - Colour code of cable Phase-Red Neutral- Black and Earth -Green)
All as per item No 85 above but point wiring for one 5 / 6 Amps socket outlet on independent board controlled by one-way switch.
All as per item No 85 above but point wiring for one 5 Amps socket outlet on same board controlled by one-way switch.
All as per item No 85 above but wiring with 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable and 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable as earth wire connected to common earth dolly for 15 Amps multipurpose socket outlet on independent board, controlled with one way switch.
S&F modular one way switch 6 Amp 240 volt marked light / fan suitable for one moduel etc complete as specified and directed.
S&F Modular 6 Amp 5 pin universal socket suitable for two moduel , 250 volts complete all as specified and directed.
S&F modular switch one way 16 Amps 240 volts suitable for one moduel complete as specified and directed.
S&F Modular 6 /16 Amp socket suitable for two moduel , 250 volts complete all as specified and directed.
S&F modular step type two moduel fan regulator suitable for 120 watt 250 volts complete as specified and directed.
M&L for ceiling rose with three terminal as per relevant IS complete as specified and directed
S&F in repair energy efficient LED tube light fitting with built in LED & integral LED driver 18 to 20 watt, channel housing & diffuser of length 1200 mm (approx) with all accessories, fixing arrangement internally pre-wired, fixed in position & connecting complete all as specified and directed by Engg –in-charge.
S&F in repair energy efficient LED tube light fitting with built in LED & integral LED driver 10 watt, channel housing & diffuser of length 600 mm (approx) with all accessories, fixing arrangement internally pre-wired, fixed in position & connecting complete all as specified and directed by Engg –in-charge.
S&F in repair surface mounted round type energy saving ceiling mounted decorative LED 8 watt luminair with opal diffuser for soft light with suitable driver etc complete as specified and directed by Engr-in-charge
S&F Energy saving new generation 10 W LED IP 65 bulkhead luminair with opal diffuser etc complete as specified and directed by Engr-in-charge.
S&F in repair epoxy powder coated or polystrene insulated material sheet metal enclosure factory made (double door) 8 way SPN suitable for MCB DB's 240 Volts with 200 Amps rated busbar, neutral & earthing link bar, flush/surface mounting complete all as specified and directed
S&F MCB single pole ISI marked ISI Marked `C' series working on 240 Volts 50 HZ AC supply for incomming and out going controlling cercuit of capacity 6-32 Amp breaking capacity 10 KA etc all as specified and directed.
S&F MCB single pole and neutral ISI marked `C' series working on 240 volts 50HZ AC supply for incomming & out going controlling system of capaicty 40 Amps 10 KA breaking capacity etc all as specified and directed.
Material & Labour for sub main wiring with 2 run single core multistranded copper conductor cable, of size 6.0 Sqmm, PVC insulated, unsheathed, fire retardant low smoke, drawn through and including heavy duty rigid PVC conduit not less than 20 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 6.0 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling, including taking down old sub main wiring complete. Note: (i) 2 Runs of main cable and one run earth wire with conduit will be measured as one Unit for payment.
Suppy and fix in repair Socket outlet 2 in 1, 3 pin, 5 and 15 A complete all as specified and directed by Engr-in-Charge.
Suppy and fix in repair Socket outlet 2 in 1, 3 pin, 5 A complete all as specified and directed by Engr-in-Charge.
Suppy and fix in repair Switch piano, flush type single pole, one way 5 Amp complete all as specified and directed by Engr-in-Charge.
M/S Ghulam Mohammad Shalla
NAJAR ENTERPRISES
M/S NEW FAROOQ TRADERS
M/S ABDUL REHMAN WANI
M/S M B ENTERPRISES
M/S WANI AND SONS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .