Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.3 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹33.1 L+₹21,368.60 (0.65%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹36.6 L+₹3.7 L (11.3%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹52.3 L+₹19.5 L (59.3%)Rejected-Finance 1A BASEMENT 30 31 RAJA HOUSE NEHERU PLACE NEW DELHI | NEW DELHI | NEW DELHI | DELHI | L4 | Rejected-Finance Being L4 |
Tender Value
₹30.1 L
EMD Value
₹60,100
Closing Date
24 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER (MIS) MHOW
Garrison Engineer (Maint) Infantry School , Mhow - 453441
PROVISION OF 3 PH POWER SUPPLY TO BLDG NO CB 01 AND 02 AND IMPROVEMENT OF LT DISTRIBUTION SYSTEM AT SANGRILA TRIMURTI CHAUK TO SOMNATH HALL ICTW TO SIGNAL EXCHANGE AT INF SCHOOL UNDER GE MIS MHOW
2023_MES_625341_1
8611/GE(MIS)/MHOW
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
INFANTRY SCHOOL MHOW
All as per Tender document
7 documents required · 7 mandatory
₹500
Garrison Engineer (Maint) Inf School
₹60,100
Yes
19 Dec 2023
27 Oct 2023
27 Nov 2023
27 Oct 2023
24 Nov 2023
10 Nov 2023
Amount
Dismantling / Taking down ACSR conductors of any type & size from existing LT pole ,taking aside by disconnecting all electrical connection complete all as specified and directed
Dismantling / Taking down cross arms of mild steel channel or angle section etc complete all as specified and directed
Dismantling insulatotrs of any type and size from existing LT pole complete all as specified
Taking out unserviceable LT service connection cable of size up to 3.5 core x 35 sqmm complete all as specified and directed.
Taking out old unserviceable LT cable of size 3.5 core , 50 sqmm up to 120 sqmm complete all as specified and directed.
S&F XLPE insulated and PVC armoured heavy duty electric cables with aluminum conductor, 1100 volt grade in trenches / through pipes /ducts or on poles / walls jointing to over head conductor, LT panels, main switch with suitable size aluminum lugs and testing complete all as specified for the following sizes:- Note : Earth work excavation shall be measured and paid seperately under respective item
185 Sqmm 3.5 core
120 Sqmm 3.5 core
95 Sqmm 3.5 core
50 Sqmm 3.5 core
35 Sqmm 3.5core
10 Sqmm 4 core
Excavating in trenches, in any type of soil not exceeding 1.5m wide and not exceeding 1.5m in depth for laying cable, pole foundation etc complete all as specified.
Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete.
Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete.
M&L for sand cushioning with fine dry unwashed sand in trenches for protection of cables complete. Note :- Thickness shall be measured after punning
M&L for old size sub class ‘B’ bricks, laid in trenches as a cable covers complete.
S&F in repair galvanised iron pipe 80mm bore "light grade" in trenches, under floors, roads, along poles for protection of cable including all necessary fittings and sealing ends complete all as specified
S&F in repair galvanised iron pipe 40mm bore "light grade" in trenches, under floors, roads, along poles for protection of cable including all necessary fittings and sealing ends complete all as specified
Supply and errecting factory made CPRI approved LT Panel board of size 600mmx600mmx300mm ,outdoor type mounted on PCC 1:2:4 type B1 foundation , made out of mild steel CRCA sheet 3.15 mm thick , fabricated with suitable size mild steel angle iron frame and all steel surface painted with two coats of grey colour synthetic enamel paint over a coat of red oxide zinc chrome primer by using spraying machine including preparation of surface, civil work as required at site for fixing panel board , internal wiring with copper cable of suitable size, connecting including indication lamp LED type for each phase , inbuilt industrial type locking arrangments , front openable, necessary arrangments for fixing with suitable size clamps,nuts, bolts wahers,danger notice board , feeder marked,testing and commissioning complete all as specified and directed by Engineer-in-Charge.
S&F cable path indicator of size 200 mm x 150 mm x 3 mm thick made with mild steel sheet including leg spot welding with angle iron of size 40mm x 40mm x 5 mm thick, 750 mm long embedded in PCC 1:2:4 type B1 using 20mm graded granite stone aggregate including providing one coat of synthetic enamlled black paint over a coat of red oxide primer and sign writing with white paint showing size of cable HT /LT complete all as specified and directed .
M&L for cutting the existing bituminouse road surface of any description ,not exceeding 45cm width for passing of UG Cable in road crossing and making good the disturbed road surface to match with the existing complete all as specified and directed
Supply, installation, testing and commissioning of out door type LT panel board of suitable size to accommodate the following accessories ,made out of 3.15mm thick CRCA sheet , factory made CPRI approved ,cubical type,with slanting top at leaset 10 Cm projection all around, fedder pillar type,fabricated with 50x50x6mm angle iron frame work with independent door for each feeder,busbar chamber cable tray on both side fully compartmentlized design, double door type, commen openable hinged door from rear side, floor mounting type, busbars made of aluminium duly insulated with heat retardent fire proof (HRFR) heat shrinkable sleeves of relevant colours,bus bar properly supported /mounted on epoxy insulators ,all live parts and joints insulated with (HRFR) shrouds, conforming to IS, including provision for connecting suitable earth strips including painting with one coat of anti corrosive paint and finally epoxy polyester powder coating of tint grey shade (RAL-7032), Confirming to IP 54 protection and confirming relavent IS, comprising the adequate arrangement to supply & fix the following accessories,including connecting cable glands and cable lugs,fixing of earth lead to earth terminal of panel including necessary earth work excavation , PCC foundation complete all as specified and directed by Engineer-in-Charge. Note:- Quoted rate shall be inclusive for all accessories as specied here in after (LT Panel No.1&2)
Incoming (a) Aluminium bus bar - 400 Amps rating - 03 Nos for phases and 150 Amp rating - 01 No. for neutral
(b) MCCB 4 pole 250 Amps, 415 volt, 36 KA - 01 No ( incoming) ( Make - Legrand ,L & T/ABB/Schenider)
(e) ON/OFF LED type indication lamp with toggle switch - Set of 03
Out going:- (a) MCCB 3 pole 160 Amp, 415 volt, 25 KA - 01 Nos (Make - Legrand ,HPL,Havells or equivalent)
(b) MCCB 3 pole 100 Amp, 415 volt, 25 KA - 02 Nos (Make - Legrand ,HPL,Havells or equivalent)
(c) MCCB 3 pole 63 Amp, 415 volt, 16 KA - 02 Nos
(d) MCB TPN 40 Amp, 415 volt, - 2 Nos
All as per item No 17.00, above but comprising of following accessories and items :-( LT Panel No 03, to 06)
Incoming (a) Aluminium bus bar - 250 Amps rating - 03 Nos. for phases and 100 Amp rating - 01 No. for neutral
(b) MCCB 4 pole 200 Amps, 415 volt, 36 KA ( Make - Legrand ,L & T/ABB/Schenider)- 01 No.( incoming)
(e) ON/OFF LED type indication lamp with toggle switch - Set of 03
Out going:- (a) MCCB 4 pole 100 Amp, 415 volt, 16 KA - 02 Nos ( Make - Legrand ,L & T/ABB/Schenider)
(b) MCCB 4 pole 63 Amp, 415 volt, 16 KA - 02 Nos ( Make - Legrand ,L & T/ABB/Schenider)
(c) MCB TPN 40 Amp, 415 volt, - 2 Nos ( Make - Legrand ,L & T/ABB/Schenider)
All as per item No 17.00, above but comprising of following accessories and items :-( LT Panel No 07)
Incoming (a) Aluminium bus bar - 250 Amps rating - 03 Nos. for phases and 150 Amp rating - 01 No. for neutral
(b) MCCB 3 pole 160 Amps, 415 volt, 25 KA - 01 No ( incoming) ( Make - Legrand ,L & T/ABB/Schenider)
(e) ON/OFF LED type indication lamp with toggle switch - Set of 03
Out going:- (a) MCCB 3 pole 100 Amp, 415 volt, 16 KA - 02 Nos ( Make - Legrand ,L & T/ABB/Schenider)
(b) MCCB 3 pole 63 Amp, 415 volt, 16 KA - 01 Nos ( Make - Legrand ,L & T/ABB/Schenider)
(c) MCB TPN 40 Amp, 415 volt, - 01 Nos ( Make - Legrand ,L & T/ABB/Schenider)
S&F in repairs moulding compound street light junction box of size 250 mm x 250 mm x 160mm complete with shock and rust proof, termite resistant, tamper proof , front openable type including suitable provision for three phase, four wire cable (size upto 25 Sqmm 4 Core) incomming & outgoing loop -in loop connection and including one no.of MCB SP 6 Amp and non metallic clamps , GI nut bolts and washers of suitable size and fixed on pole / wall complete all as specified . Make : Sintex Cat part No GSJB 2525 or other equivalent in Hensel/ABB.
S&F in repairs two core pvc insulated and sheathed cable with multistranded aluminium condutor of size 2.5 sqmm x two core and drawn into existing GI pipe/ PVC Pipe, bracket and connect to street light fittings complete all as specified and directed .( Make:- Polycab/ RR/ Finolex/Gloster).
Supply, installation testing , commissioning and replacement of street light control box as a pole mountable enclosure conforms to IP-64 suitable for 440/230V, AC, 50 Hz, consisting of light sensitive control system, power contactor for load switching, MCB and terminal suitable for 3 phase, 5 KW load blocks all as specified .Make: Swadeep Nature Swith model No 02EC5kW3P or other equivalent in CG/L&T/phillips
S&F in repairs PVC tube 20mm bore medium grade, ISI marked for laying of sub-main wire /cable on Street Light Poles and on wall including necessary fixing arrangments like PVC band, clamps , nut ,bolts etc.complete all as specifird
M&L for earthing complete with GI earth plate electrode of size 60cm X 60cm X 6mm thick buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using GI strip of size 32mmx6mm by means of bolts, nuts, check nuts and washers made of galvanised iron and protected by light grade 50mm dia GI pipe connected to main switch board or main control board and GI pipe 20mm dia light grade for watering including funnel, wire mesh, RCC cover slab 50mm thick with 8mm dia reinforcement 100mm c/c and PCC chamber pit with cement concrete 1:2:4 type B1 including excavation and earth work, disposal of surplus soil to a distance not exceeding 50 metre complete all as specified and shown on plate No 5 of SSR Part-I 2009.
Note: (a) Quoted rate shall be inclusive for protection pipe, GI water pipe, wire mesh, funnel, excavation, RCC pit cover, test point, 25mm x 4mm GI strip from top of earth plate upto 7.5 metre above ground level
Supply ,fabrication, installation and testing of LT Panel out door type factory made CPRI Approved, water and vermin proof protection of size not less than 1500 mm x 1200 mm x 800 mm (over all dimension) made out of 3.00 mm thick CRCA sheet dully supported with mild steel angle iron of size 50 x 50 x 6 mm vertical frame and legs with mild steel flat iron 25 x 5 mm in horizontal sides of the frame with front and back side openable ,single hinged door / shutter with locking arrengement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces including providing PCC 1:3:6 type C2 foundation of suitable size and connections of all outgoing / incomming cable inclusive of necessary excavation and earthwork as required including the following fitment accessories complete all as specified and as directed. . NOTE:- Quoted rate shall be inclsive for earthwork excavation and foundation concrete as required for fixing panel
INCOMMING
(a) Copper strip busbar of 630 amps rated capaacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends = 04 Nos
(b) 4 pole MCCB 400 Amps with rotary handle, adjustable thermal magnetic release type 415 Volts, Ics = 100% Icu, breaking capacity 35 KA including all fixing accessories with both ends spreader links - 01 No.
(c) LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts, AC -01 set (set of three) Make :- Legrand/L&T/Schneider/ ABB.
OUTGOING
(f) 4 Pole MCCB 250 Amps with rotary handle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links -01 Nos
(g) 4 Pole MCCB 160 Amps with rotary handle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links -03 Nos
(h) 4 Pole MCCB 63 Amps with rotary handle, adjustable thermal magnetic release type, 4 poles, 415 Volts, including all fixing accessories with both ends spreader links -02 Nos
(j) Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm x 150 mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of JB for LT -01 No.
Auto Traders
Ms Kailash Chandra Babulal
MONA GENERATOR SEVICES PVT. LTD.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .