| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹23.5 LAdmitted-Finance 5574 A KANSHI RAM MARKET NEW CHANDRAWAL KAMLA NAGAR DELHI 07 | -32.58% | ₹23.5 L | L1 | Admitted-Finance |
| 2 | L2₹23.9 L+₹35,950.12 (1.53%)Admitted-Finance 0 0 0 ABABAKPUR KANPUR NAGAR UTTAR PRADESH 209203 UDYAM UP 43 0068644 | KANPUR NAGAR | UTTAR PRADESH | 209203 | -31.55% | ₹23.9 L+₹35,950.12 (1.53%) | L2 | Admitted-Finance |
| 3 | L3₹26.6 L+₹3.0 L (12.9%)Admitted-Finance | -23.90% | ₹26.6 L+₹3.0 L (12.9%) | L3 | Admitted-Finance |
| 4 | L4₹28.1 L+₹4.6 L (19.4%)Admitted-Finance | -19.50% | ₹28.1 L+₹4.6 L (19.4%) | L4 | Admitted-Finance |
| 5 | L5₹28.6 L+₹5.0 L (21.4%)Admitted-Finance C 6 9 YAMUNA VIHAR DELHI 53 | NEW DELHI | DELHI | 110001 | -18.18% | ₹28.6 L+₹5.0 L (21.4%) | L5 | Admitted-Finance |
Tender Value
₹34.9 L
EMD Value
₹69,900
Closing Date
18 Apr 2026, 1:00 pmClosed
Executive Engineer (Elect)-I
OFFICE OF THE Ex. ENGINEER (ELECT)-I, SHAHDARA (N) ZONE, KeshavChowk, Delhi-110053
Comprehensive AMC (Annual Maintenance Contract) for repair and Maintenance of Permanents storm/mixed water pumping sets of EEE-I , SHD North Zone in MCD.
2026_MCD_274563_1
EE(E)-I/Sh.N/MCD/26-27/TC-3/1
Open Tender
Electrical Works
Percentage
365 days
As per NIT
Please refer Tender documents.
7 documents required · 7 mandatory
₹590
₹69,900
12 May 2026
11 Apr 2026
18 Apr 2026
11 Apr 2026
18 Apr 2026
11 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Comprehensive AMC of the following dia/Model of Electric pump sets for attending and rectifying the mechanical defects /complaints i/c routine maintenance along with all accessories e.g overhauling of diesel engine , repairing of radiator and pump, repairing of shaft , shaft sleeve, Pump bearing , impeller, NRV , Sluice valve , i/c dismantling transportation, installation , testing and commissioning after repair by necessary tools and tackles etc as required installation in mix/storm water pumping station. 38 BHP( SHM 150/26 N). | 5 | Each | 94,000 | ₹4,70,000 |
| 2 | Comprehensive AMC of the following dia/Model of Electric pump sets for attending and rectifying the mechanical defects /complaints i/c routine maintenance along with all accessories e.g overhauling of diesel engine , repairing of radiator and pump, repairing of shaft , shaft sleeve, Pump bearing , impeller, NRV , Sluice valve , i/c dismantling transportation, installation , testing and commissioning after repair by necessary tools and tackles etc as required installation in mix/storm water pumping station. 50 BHP( SHM 200/32 N). | 2 | Each | 1,05,000 | ₹2,10,000 |
| 3 | Comprehensive AMC of the following dia/Model of Electric pump sets for attending and rectifying the electrical mechanical defects /complaints i/c routine maintenance along with all accessories e.g rewinding of motor , repairing pf pumps repairing of shaft , shaft sleeve, bearing , impeller, motor bearing, NRV , Sluice valve , Starter , main switch, cable i/c dismantling transportation, installation , testing and commissioning after repair by necessary tools and tackles etc as required installation in mix/storm water pumping station. 25 HP( SHM 150/26 N). | 6 | Each | 50,000 | ₹3,00,000 |
| 4 | Comprehensive AMC of the following dia/Model of Electric pump sets for attending and rectifying the electrical mechanical defects /complaints i/c routine maintenance along with all accessories e.g rewinding of motor , repairing pf pumps repairing of shaft , shaft sleeve, bearing , impeller, motor bearing, NRV , Sluice valve , Starter , main switch, cable i/c dismantling transportation, installation , testing and commissioning after repair by necessary tools and tackles etc as required installation in mix/storm water pumping station. 30 HP( SHM 150/26). | 1 | Each | 51,047 | ₹51,047 |
| 5 | Comprehensive AMC of the following dia/Model of Electric pump sets for attending and rectifying the electrical mechanical defects /complaints i/c routine maintenance along with all accessories e.g rewinding of motor , repairing pf pumps repairing of shaft , shaft sleeve, bearing , impeller, motor bearing, NRV , Sluice valve , Starter , main switch, cable i/c dismantling transportation, installation , testing and commissioning after repair by necessary tools and tackles etc as required installation in mix/storm water pumping station. 40 HP( SHM 150/26 N). | 13 | Each | 54,888 | ₹7,13,544 |
| 6 | Comprehensive AMC of the following dia/Model of Electric pump sets for attending and rectifying the electrical mechanical defects /complaints i/c routine maintenance along with all accessories e.g rewinding of motor , repairing pf pumps repairing of shaft , shaft sleeve, bearing , impeller, motor bearing, NRV , Sluice valve , Starter , main switch, cable i/c dismantling transportation, installation , testing and commissioning after repair by necessary tools and tackles etc as required installation in mix/storm water pumping station. 75 HP( SHM 200/32). | 8 | Each | 90,084 | ₹7,20,672 |
| 7 | Comprehensive AMC of the following dia/Model of Electric pump sets for attending and rectifying the electrical mechanical defects /complaints i/c routine maintenance along with all accessories e.g rewinding of motor , repairing pf pumps repairing of shaft , shaft sleeve, bearing , impeller, motor bearing, NRV , Sluice valve , Starter , main switch, cable i/c dismantling transportation, installation , testing and commissioning after repair by necessary tools and tackles etc as required installation in mix/storm water pumping station. 100 HP( MF 35/35). | 4 | Each | 1,42,560 | ₹5,70,240 |
| 8 | Comprehensive AMC of the following dia/Model of Electric pump sets for attending and rectifying the electrical mechanical defects /complaints i/c routine maintenance along with all accessories e.g rewinding of motor , repairing pf pumps repairing of shaft , shaft sleeve, bearing , impeller, motor bearing, NRV , Sluice valve , Starter , main switch, cable i/c dismantling transportation, installation , testing and commissioning after repair by necessary tools and tackles etc as required installation in mix/storm water pumping station. 150 HP( MP 35/35). | 3 | Each | 1,51,600 | ₹4,54,800 |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.23 MB
ConditionsCAMC.pdf
Tender Documents • 0.45 MB
GCC2024.pdf
Tender Documents • 9.36 MB
Circular_1.pdf
Tender Documents • 2.39 MB
BOQ_320531.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .