Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.4 LAccepted-AOC | L1 | Accepted-AOC Acceptance of tender | |
| 2 | L2₹34.2 L+₹1.4 L (4.22%)Rejected-Finance | L2 | Rejected-Finance being not L1 | |
| 3 | Rejected-Technical | - | Rejected-Technical Rejected due to non-uploading of tender fee |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
16 Nov 2022, 6:00 pmClosed
CWE Lucknow
HQ CWE Lucknow, 229 MG Road, Lucknow Cantt, Lucknow-226002
REDEVELOPMENT OF BORE WELL AND REPAIR REPLACEMENT TO OLD/UNSV/CORREDED COLUMN PIPE UNSV SUBMERSIBLE CABLE NRV SLUICE VALVE VALVE PIT CHAMBER AND CERTAIN MISC WORK AT LUCKNOW CANTT UNDER GE E/M LUCKNOW
2022_MES_540961_4
CWE/LKO/EM/T-52 OF 2022-23
Open Tender
Civil Works - Others
Item Rate
180 days
Lucknow
All contractors enlisted with MES in class D and above and category (a)(ii)
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹60,000
Yes
12 Dec 2022
28 Oct 2022
18 Nov 2022
28 Oct 2022
16 Nov 2022
4 Nov 2022
28 Oct 2022 - 4 Nov 2022
Amount
Redeveloping borewelll by compressed air with minimum pressure of 10Kg/Sq cm to 30 Kg / Sq cm and minimum 450 CFM all as specified in IS 11189-1985, para 4.3 and directed at site. Note : (i) Compressor, pump, pipe and other allied items shall be arranged by the contractor and nothing extra shall be admissible on this account.
Redeveloping borewell by over pumping for borewell complete after development by compressor and water shall be used only after receipt of satisfactory test result as per IS, all as specified and directed. Note : Over pumping will be carried out by pumping the water at higher capacity i.e. not less than 50% above the yield of bore well. Cost of arranging pump and compressor is deemed to be included in the unit rate quoted.
M&L Pea gravel of 2 mm to 4 mm size of approved quality as ordered to pack around the casing/slotted pipes in bore well in angular space between well assembly and bore hole wall should be over minimum 15-18 cm and thoroughly washed before sorrounding in the well and treated, with suitable amount of sodium hexa-metaphosphate for 24 hrs before developing by compressed air complete all as specified and directed.
Chemical and bacteriological testing of WATER, sample collecting from re-devoloped borewell & testing carried out from authorized Govt laboratory to ensure potability of water complete along with certified report all as specified and directed.
M&L Plain cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete all as specified and directed.
M&L Plain cement concrete (1:3:6) type C-1 using 20mm graded stone aggregate as in foundation filling and mass concrete all as specified and directed.
M&L for MS black column pipe, 3 mtr long heavy duty, 100mm bore wall thickness 5.4mm, both end flanged with heavy duty MS flanged not less than 16mm screwed and welded inside and outside. The flange end making surface shall be made smooth including welding of 04 strip of 5.0mm thick 25mm wide and 50mm long covering pipe and both end flanged having 08 Nos predrilled hole not less than 16mm including rubber gasket, nut bolts and washer. Pipe should be duly painted with anti corrosive paint complete all as specified and directed.
M & L in repair for flange pipe joints with 3mm thick rubber gasket (packing ring) incl provision of suitable size bolts, nuts and washers etc. 150mm bore pipe complete all as specified and directed
M & L in repair for flange pipe joints with 3mm thick rubber gasket (packing ring) incl provision of suitable size bolts, nuts and washers etc. 100mm bore pipe complete all as specified and directed
S & F in repairs cast iron specials ISI marked for pressure water mains upto 150mm bore spigot and socket Tee pieces, single or double brunch connection or collar etc. complete all as specified and directed. Note : Excavation and earth work shall be measured and paid for separately.
S&F sluice valve 150mm bore both ends flanged class PN 1.6 with brass spindle and 01 No hand wheel including making new flanged joint with 3mm thick rubber gasket (Packing ring) with necessary bolt, nuts and washer of suitable size complete all as specified and directed.
S & F Non Return valve (NRV) both end flanged 150mm dia ISI marked without bypass arrangement incl jointing material such as nut, bolts andwasher commissioning and testing complete all as specified and directed
Disconnection of submersible pump set of any size from existing water supply system by mechanical & electrical. Taking out /Uplifting the unserviceable/ Serviceable pump set from deep borewell by disconnecting from lowering pipe line of any size with manual or suitable electric driven chain pully upto 240 ft depth. Relowering the submersble pump set in same borewell and re-connection of complete all as specified and directed. Note:- i) All type of T/P required to complete the job will be arranged by contractor. (ii) Job will be done round -o-clock continued as per site requirement as directed by AGE. (iii) Delay in job will be charged on the basis of Rs. 500/- per hour. (iv) Items required for motor connection such as PVC insulation tape, valcanised rubber / puncture tube etc will be provided by the contarctor to complete the work and rate as deemed to be quoted in unit rate no extra payment will be made to the contractor.
M&L for construction of valve chamber 1050×1050×1050mm internal dimensions, 3mm thick MS sheet cover with 2 Nos MS hinges welded to angle iron frame of 40mm×40mm ×6mm thick with lifting hook and locking arrangement with brass pad lock of 65mm dia with triplicate keys complete with necessary earth work, brick work in CM (1:6), 230 mm thick, PCC bed (1:4:8) type D2 150mm thick, cement plastering, finishing 15mm thick in CM (1:4) and applying a coat of black bituminous paint to the steel surfaces complete all as specified and directed.
S & F in repair submersible cable PVC insulated and PVC sheathed copper conductor 16 Sqmm, 3 core, 1100 volts grade flat cable conforming to IS-694 1977 complete with necessary electric connection complete all as specified and directed
S & F in repair submersible cable PVC insulated and PVC sheathed copper conductor 10 Sqmm, 3 core, 1100 volts grade flat cable conforming to IS-694 1977 complete with necessary electric connection complete all as specified and directed
M & L Yield testing in repair for the bore well by continuously pumping for 16 hours to determine safe pumping yield with the help of ORIFICE method complete all as specified and directed (Yield test report to be submitted and kept for record)
Demolition of PCC of any type all as specified and directed by Enge-in-Charge
Shailza Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .